Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting (SC) circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in SC films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu–Shiba–Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

metal/substrate interlayer↗

SU-E-T-567: Neutron Dose Equivalent Evaluation for Pencil Beam Scanning Proton Therapy with Apertures

Purpose: To determine the neutron contamination from the aperture in pencil beam scanning during proton therapy. Methods: A Monte Carlo based proton therapy research platform TOPAS and the UF-series hybrid pediatric phantoms were used to perform this study. First, pencil beam scanning (PBS) treatment pediatric plans with average spot size of 10 mm at iso-center were created and optimized for three patients with and without apertures. Then, the plans were imported into TOPAS. A scripting method was developed to automatically replace the patient CT with a whole body phantom positioned according to the original plan iso-center. The neutron dose equivalent was calculated using organ specific quality factors for two phantoms resembling a 4- and 14-years old patient. Results: The neutron dose equivalent generated by the apertures in PBS is 4–10% of the total neutron dose equivalent for organs near the target, while roughly 40% for organs far from the target. Compared to the neutron dose equivalent caused by PBS without aperture, the results show that the neutron dose equivalent with aperture is reduced in the organs near the target, and moderately increased for those organs located further from the target. This is due to the reduction of the proton dose around the edge of the CTV, which causes fewer neutrons generated in the patient. Conclusion: Clinically, for pediatric patients, one might consider adding an aperture to get a more conformal treatment plan if the spot size is too large. This work shows the somewhat surprising fact that adding an aperture for beam scanning for facilities with large spot sizes reduces instead of increases a potential neutron background in regions near target. Changran Geng is supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087)

61 RADIATION PROTECTION AND DOSIMETRY↗

A path to higher Q0 with large grain niobium cavities

The improvement of the quality factor Q{sub 0} of superconducting radio-frequency (SRF) cavities at medium accelerating gradients ({approx} 20 MV/m) is important in order to reduce the cryogenic losses in continuous wave accelerators for a variety of applications. In recent years, SRF cavities fabricated from ingot niobium have become a viable alternative to standard high-purity fine-grain Nb for the fabrication of high-performing SRF cavities with the possibility of significant cost reduction. Initial studies demonstrated the improvement of Q{sub 0} at medium field in cavities heat treated at 800-1000 C without subsequent chemical etching. To further explore this treatment procedure, a new induction furnace with an all-niobium hot-zone was commissioned. A single-cell 1.5 GHz cavity fabricated from ingot material from CBMM, Brazil, with RRR {approx} 200, was heat treated with the new furnace in the temperature range 600-1200 C for several hours. Residual resistance values 1-5 nano-ohm have been consistently achieved on this cavity as well as Q{sub 0} values above {approx} 2 x 10{sup 11} at 2 K and 100 mT peak surface magnetic field. Q{sub 0}-values of the order of 10{sup 11} have been measured at 1.5 K.

43 PARTICLE ACCELERATORS↗

DISCOVERY OF A 7 mHz X-RAY QUASI-PERIODIC OSCILLATION FROM THE MOST MASSIVE STELLAR-MASS BLACK HOLE IC 10 X-1

We report the discovery with XMM-Newton of an Almost-Equal-To 7 mHz X-ray (0.3-10.0 keV) quasi-periodic oscillation (QPO) from the eclipsing, high-inclination black hole binary IC 10 X-1. The QPO is significant at >4.33{sigma} confidence level and has a fractional amplitude (% rms) and a quality factor, Q {identical_to} {nu}/{Delta}{nu}, of Almost-Equal-To 11 and 4, respectively. The overall X-ray (0.3-10.0 keV) power spectrum in the frequency range 0.0001-0.1 Hz can be described by a power-law with an index of Almost-Equal-To - 2, and a QPO at 7 mHz. At frequencies {approx}>0.02 Hz there is no evidence for significant variability. The fractional amplitude (rms) of the QPO is roughly energy-independent in the energy range of 0.3-1.5 keV. Above 1.5 keV the low signal-to-noise ratio of the data does not allow us to detect the QPO. By directly comparing these properties with the wide range of QPOs currently known from accreting black hole and neutron stars, we suggest that the 7 mHz QPO of IC 10 X-1 may be linked to one of the following three categories of QPOs: (1) the 'heartbeat' mHz QPOs of the black hole sources GRS 1915+105 and IGR J17091-3624, or (2) the 0.6-2.4 Hz 'dipper QPOs' of high-inclination neutron star systems, or (3) the mHz QPOs of Cygnus X-3.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray variability and the inner region in active galactic nuclei

We present theoretical models of X-ray variability attributable to orbital signatures from an accretion disk including emission region size, quasi-periodic oscillations (QPOs), and its quality factor Q, and the emergence of a break frequency in the power spectral density shape. We find a fractional variability amplitude of F{sub var}∝M{sub ∙}{sup −0.4}. We conduct a time series analysis on X-ray light curves (0.3-10 keV) of a sample of active galactic nuclei (AGNs). A statistically significant bend frequency is inferred in 9 of 58 light curves (16%) from 3 AGNs for which the break timescale is consistent with the reported BH spin but not with the reported BH mass. Upper limits of 2.85 × 10{sup 7} M {sub ☉} in NGC 4051, 8.02 × 10{sup 7} M {sub ☉} in MRK 766, and 4.68 × 10{sup 7} M {sub ☉} in MCG-6-30-15 are inferred for maximally spinning BHs. For REJ 1034+396 where a QPO at 3733 s was reported, we obtain an emission region size of (6-6.5) M and a BH spin of a ≲ 0.08. The relativistic inner region of a thin disk, dominated by radiation pressure and electron scattering, is likely to host the orbital features as the simulated Q ranges from 6.3 × 10{sup –2} to 4.25 × 10{sup 6}, containing the observed Q. The derived value of Q ∼ 32 for REJ 1034+396 therefore suggests that the AGN hosts a thin disk.

79 ASTRONOMY AND ASTROPHYSICS↗

An X-band high-impedance relativistic klystron amplifier with an annular explosive cathode

The feasibility of employing an annular beam instead of a solid one in the X-band high-impedance relativistic klystron amplifier (RKA) is investigated in theory and simulation. Small-signal theory analysis indicates that the optimum bunching distance, fundamental current modulation depth, beam-coupling coefficient, and beam-loaded quality factor of annular beams are all larger than the corresponding parameters of solid beams at the same beam voltage and current. An annular beam RKA and a solid beam RKA with almost the same geometric parameters are compared in particle-in-cell simulation. Output microwave power of 100 MW, gain of 50 dB, and power conversion efficiency of 42% are obtained in an annular beam RKA. The annular beam needs a 15% lower uniform guiding magnetic field than the solid beam. Our investigations demonstrate that we are able to use a simple annular explosive cathode immersed in a lower uniform magnetic field instead of a solid thermionic cathode in a complicated partially shielding magnetic field for designing high-impedance RKA, which avoids high temperature requirement, complicated electron-optical system, large area convergence, high current density, and emission uniformity for the solid beam. An equivalent method for the annular beam and the solid beam on bunching features is proposed and agrees with the simulation. The annular beam has the primary advantages over the solid beam that it can employ the immersing uniform magnetic field avoiding the complicated shielding magnetic field system and needs a lower optimum guiding field due to the smaller space charge effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Room temperature detector array technology for the terahertz to far-infrared.

Thermal detection has made extensive progress in the last 40 years, however, the speed and detectivity can still be improved. The advancement of silicon photonic microring resonators has made them intriguing for detection devices due to their small size and high quality factors. Implementing silicon photonic microring or microdisk resonators as a means of a thermal detector gives rise to higher speed and detectivity, as well as lower noise compared to conventional devices with electrical readouts. This LDRD effort explored the design and measurements of silicon photonic microdisk resonators used for thermal detection. The characteristic values, consisting of the thermal time constant ({tau} {approx} 2 ms) and noise equivalent power were measured and found to surpass the performance of the best microbolometers. Furthermore the detectivity was found to be D{sub {lambda}} = 2.47 x 10{sup 8} cm {center_dot} {radical}Hz/W at 10.6 {mu}m which is comparable to commercial detectors. Subsequent design modifications should increase the detectivity by another order of magnitude. Thermal detection in the terahertz (THz) remains underdeveloped, opening a door for new innovative technologies such as metamaterial enhanced detectors. This project also explored the use of metamaterials in conjunction with a cantilever design for detection in the THz region and demonstrated the use of metamaterials as custom thin film absorbers for thermal detection. While much work remains to integrate these technologies into a unified platform, the early stages of research show promising futures for use in thermal detection.

36 MATERIALS SCIENCE↗

Feasibility Studies on a Hexagonal-Lattice Core for a World-Class Cold Neutron Source

Cold neutrons have kinetic energies less than 5 meV and wavelengths greater than 4 Α. They can be transported over tens of meters through super-reflecting neutron guides with minimal losses. Cold neutrons are used to investigate the structure of larger molecular systems such as biological materials, polymers and aggregates, due to their preferential interaction with light elements and general ignorance towards heavy ones. Intense beams of cold neutrons are obtained from slowing down a source of thermal energy neutrons - which may be from either a research reactor or spallation neutron source - through some cryogenic moderator such as liquid hydrogen or deuterium. The present reactor at the NIST Center for Neutron Research (NCNR) - NBSR - is such a cold neutron source (CNS) facility which provides cold neutron beams for over 2,000 scientists performing various experiments annually. Feasibility studies on a replacement reactor for the NBSR are underway at NCNR with the primary purpose of optimized cold neutron production. Low enriched uranium (LEU) fuel is required for the new reactor to conform to nuclear non-proliferation agreements. The low thermal power rate of 20 MW is taken as a priority with a fuel cycle length designated as 30 days. A horizontal split compact core with a large D{sub 2}O reflector tank is currently proposed and studied, with the expectation of achieving much better cold neutron performance than the present NIST reactor (NBSR). A preliminary core design has been completed using MCNP6 modeling and simulation. The physics performance characteristics of the proposed new core indicate that the new design is competitive with the most notable existing advanced cold neutron sources. In previous studies, only rectangular shaped fuel elements were considered because they have similar external dimensions as the NBSR fuel elements. However, from a compact core standpoint, a square lattice is not the most effective geometry for a tight configuration. Moreover, the previous studies also showed that the square lattice of the fuel elements left little room to accommodate vertical insertion blade-type control elements. As a result, all control blades had to reside in the D{sub 2}O reflector, which made the design cumbersome (in that case the control blades must penetrate the reflector tank) and neutronically uneconomical. In this summary, a preliminary feasibility study on a hexagonal core lattice is performed to render an alternative geometry for the new reactor (HEX core) to provide sufficient space for the control elements. The identical LEU fuel (U{sub 3}Si{sub 2}/Al) with U-235 enrichment 19.75% is used in the new design. The maximum thermal power and fuel management scheme remain the same as the previous investigations (three 30-day cycled batches for each batch of three fuel elements). The horizontal split compact core concept is also applied in the hexagonal lattice core design, with the objective of creating maximum thermal flux traps between the split core halves. A detailed description of the model for the hexagonal lattice core is presented in the following section. The HEX core design achieves a number of successes over the previous split-core design. Given that much of the motivation of this work was based on implementation of control blades into a concept which lacked them, it is notable that neutron economy was well-preserved in the process of achieving conservatively effective reactivity control; start-up k{sub eff} was in fact increased by 0.23% and peak thermal flux increased by ∼25%. A useful metric in determining the efficacy of resources towards creating an environment for the production of cold neutrons - dubbed the 'quality factor' (QF) - is the ratio of peak thermal neutron flux in a system to the total thermal power produced. Because HEX core's objectives are very focused in comparison to existing research reactors, it is fitting to pursue a design which out-performs all others in terms of some specific performance metric, namely this QF term. While HFIR remains the greatest cold neutron source in the world, it does so through use of HEU fuel (which will be replaced with LEU in the near future), and suffers a greater level of fast neutron contamination that is expected from the HEX design. The new core design achieves these successes due to the hexagonal lattice fuel arrangement, a 13.5% reduction in cladding mass, and a 13.1% reduction in fuel element volume. In spite of a 5.5% reduction in fuel mass, no compromises in reactor performance were noted. Provided the favorable characteristics shown of the control blade design, refueling intervals longer than the prescribed 30 days may be considered. It can be speculated that with these quantitative benefits, the overall capital and continuous costs of the HEX core design will be less than the previously proposed split-core concept.

07 ISOTOPE AND RADIATION SOURCES↗

Nitrogen-doped 9-cell cavity performance in a test cryomodule for LCLS-II

The superconducting RF linac for Linac Coherent Light Source-II calls for 1.3 GHz 9-cell cavities with an average intrinsic quality factor Q{sub 0} of 2.7 × 10{sup 10} at 2.0 K and 16 MV/m accelerating gradient. Two niobium 9 cell cavities, prepared with nitrogen-doping at Fermilab, were assembled into the Cornell Horizontal Test Cryomodule (HTC) to test cavity performance in a cryomodule that is very similar to a full LCLS-II cryomodule. The cavities met LCLS-II specifications with an average quench field of 17 MV/m and an average Q{sub 0} of 3 × 10{sup 10}. The sensitivity of the cavities' residual resistance to ambient magnetic field was determined to be 0.5 nΩ/mG during fast cool down. In two cool downs, a heater attached to one of the cavity beam tubes was used to induce large horizontal temperature gradients. Here, we report on the results of these first tests of nitrogen-doped cavities in a cryomodule, which provide critical information for the LCLS-II project.

43 PARTICLE ACCELERATORS↗

A Resonant Cavity Approach to Non-Invasive, Pulse-to-Pulse EmittanceMeasurement

We present a resonant cavity approach for non-invasive, pulse-to-pulse, beam emittance measurements of non-circular multi-bunch beams. In a resonant cavity, desired field components can be enhanced up to Q{sub L{lambda}}/{pi}, where Q{sub L{lambda}} is the loaded quality factor of the resonant mode {lambda}, when the cavity resonant mode matches the bunch frequency of a bunch-train beam pulse. In particular, a quad-cavity, with its quadrupole mode (TM{sub 220} for rectangular cavities) at beam operating frequency, rotated 45{sup o} with respect to the beamline, extracts the beam quadrupole moment exclusively, utilizing the symmetry of the cavity and some simple networks to suppress common modes. Six successive beam quadrupole moment measurements, performed at different betatron phases in a linear transport system determine the beam emittance, i.e. the beam size and shape in the beam's phase space, if the beam current and position at these points are known. In the presence of x-y beam coupling, ten measurements are required. One measurement alone provides the rms-beam size of a large aspect ratio beam. The resolution for such a measurement of rms-beam size with the rectangular quad-cavity monitor presented in this article is estimated to be on the order of ten microns. A prototype quad-cavity was fabricated and preliminary beam tests were performed at the Next Linear Collider Test Accelerator (NLCTA) at the Stanford Linear Accelerator Center (SLAC). Results were mainly limited by beam jitter and uncertainty in the beam position measurement at the cavity location. This motivated the development of a position-emittance integrated monitor.

43 PARTICLE ACCELERATORS↗

Ultrabroadband Spacetime Nanoscopy of Terahertz Polaritons in a van der Waals Cavity

Guiding, storing, and processing light at the nanoscale hinges on understanding how polaritons — hybrid quasiparticles of light and matter — propagate and interfere in both space and time. This work introduces a synchrotron-based technique, SYnchrotron SpaceTimE Mapping (SYSTEM), which captures real-time evolution of polariton wave packets with ∼10 nm spatial and sub-100 fs temporal resolution across an ultrabroadband 5–50 THz range. Here, SYSTEM directly visualizes the creation, interference, and decay of multiple high-quality Fabry-Pérot phonon polariton cavity modes in an α-MoO 3 microcavity. These real-space, real-time observations reveal wave-packet dynamics and cavity resonances with record-high quality factors (Q ≈ 100) in the single-digit terahertz regime near 9 THz. SYSTEM thus offers a powerful and broadly applicable platform for probing and engineering ultraslow, deeply subwavelength polaritons, opening new avenues for tailoring light–matter interactions and advancing next-generation THz nanophotonic technologies.

36 MATERIALS SCIENCE↗

MO-F-CAMPUS-T-05: Design of An Innovative Beam Monitor for Particle Therapy for the Simultaneous Measurement of Beam Fluence and Energy

Purpose: Monitoring the prescribed dose in particle therapy is typically carried out by using parallel plate ionization chambers working in transmission mode. The use of gas detectors has several drawbacks: they need to be calibrated daily against standard dosimeters and their dependence on beam quality factors need to be fully characterized and controlled with high accuracy. A detector capable of single particle counting is proposed which would overcome all these limitations. Combined with a gas ionization chamber, it will allow determining the average particle stopping power, thus providing an effective method for the online verification of the selected particle energy and range. Methods: Low-Gain Avalanche Detectors (LGADs) are innovative n-in-p silicon sensors with moderate internal charge multiplication occurring in the strong field generated by an additional p+ doping layer implanted at a depth of a few µm in the bulk of the sensor. The increased signal-to-noise ratio allows designing very thin, few tens of microns, segmented LGADs, called Ultra Fast Silicon Detectors (UFSD), optimized for very fast signal, which would be suitable for charged particle counting at high rates. A prototype UFSD is being designed for this purpose. Results: Different LGAD diodes have been characterized both in laboratory and beam tests, and the results compared both with those obtained with similar diodes without the gain layer and with a program simulating the signal in the sensors. The signal is found to be enhanced in LGADs, while the leakage current and the noise is not affected by the gain. Possible alternative designs and implementations are also presented and discussed. Conclusion: Thanks to their excellent counting capabilities, UFSD detectors are a promising technology for future beam monitor devices in hadron-therapy applications. Studies are ongoing to better understand their properties and optimize the design in view of this application.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structure and ferroelectric studies of (Ba{sub 0.85}Ca{sub 0.15})(Ti{sub 0.9}Zr{sub 0.1})O{sub 3} piezoelectric ceramics

Graphical abstract: - Highlights: • (Ba{sub 0.85}Ca{sub 0.15})(Ti{sub 0.9}Zr{sub 0.1})O{sub 3} (BCTZO) ceramic was synthesized by the ceramic method. • In situ XRD and Raman spectra showed the phase transition of BCTZO around 360 K. • The ceramics showed a tunability of 82% at 40 kV cm{sup −1} electric field. • BCTZO exhibited good quality factor of 111 at microwave frequencies. • Piezoforce microscopy studies indicated the switchability of ferroelectric domains. - Abstract: We have synthesized and studied the structural and ferroelectric properties of lead-free 0.5(Ba{sub 0.7}Ca{sub 0.3})TiO{sub 3}–0.5Ba(Zr{sub 0.2}Ti{sub 0.8})O{sub 3} ceramics in the temperature region of its ferroelectric transition. The synthesized material showed high dielectric constant, low loss and good pyroelectric figure of merit. From the temperature dependent X-ray diffraction measurements, we determined the tricritical point to be in the temperature range of 303–400 K. The dielectric measurements indicate a diffuse ferroelectric phase transition (DPT) around 360 K in agreement with the X-ray measurements. We studied the evolution of Raman spectra with temperature to understand the nature of phase transition in BaTiO{sub 3} (BTO) and the BCTZO. The results indicates that the transition of ferroelectric–paraelectric state is not sharp as in the case of BTO and the polar state persists through the paraelectric state. In general, our study indicates that there are ferroelectric domains of nanometer size beyond the commonly defined transition temperature. The observation of local piezoelectric hysteresis loop indicated the existence of intrinsic ferroelectric property of the ceramic at the nanoscale. The ceramics exhibited electric field tunable dielectric properties with a tunability of 82% at an applied DC field of 40 kV cm{sup −1}, low dielectric loss of 0.001 and room temperature pyroelectric coefficient of 6 × 10{sup −8} C cm{sup −2} K{sup −1} and the detectivity of 1.9 × 10{sup −8} C cm{sup −1} J{sup −1}; larger than those reported for other BaTiO{sub 3}-based materials. Overall, our results indicate that BCTZO ceramics with coexistence of rhombohedral–tetragonal phases is a promising candidate for lead-free ferroelectric applications.

36 MATERIALS SCIENCE↗

Characterizing Fluence as a Function of Areal Density for 1 and 14 MeV Neutrons Transported Through Air

Computing neutron dosimetry involves transporting neutrons [n] from a source to a sink, determining the neutron heating within the sink and multiplying the neutron heating by a quality factor to compute the dose equivalent. The space and energy dependent neutron fluence is a measure of the amount of neutrons crossing a particular surface area, about a particular energy and is given in units of [n/cm{sup 2}]. Microscopic cross sections are given in units of area and vary by isotope and reaction type as a function of energy. The product of the atom density of a particular atom in a specie and the microscopic cross section of a particular reaction results in the macroscopic cross section of a particular reaction, given in units of per length [1/cm] as a function of energy. Summing the macroscopic cross sections of all isotopes, and all collisions resulting in heating, within a volume, results in a total collision heating macroscopic cross section for that volume. The product of the energy and spatial dependent collision heating macroscopic cross section and the energy and spatial dependent fluence, within an energy group, results in a collision heating reaction density for that particular reaction in that energy group. Weighting each energy group's collision heating reactions, with the corresponding energy dependent particle damage per collision heating event (usually biological damage), and then integrating over energy and volume results in the delivered dose. Therefore understanding dose delivery involves examining the spatial and energy (and time) dependent fluence behavior. Because of the coupled energy and space dependence of the heating weighting and macroscopic cross sections, the fluence is not so easily separable in energy and space; however, the energy integrated fluence can be used as a first order approximation of the relative magnitude of reactions as a function of space. Here we examine the first part in the dosimetry calculation process, transporting neutrons from source to sink, as applied to neutron transport in air, examining characteristics of the fluence. Presented here is analysis regarding the nature of the fluence peak between 10 g/cm{sup 2} and 100 g/cm{sup 2} for a typical air transport calculation. Due to the high concentration of nitrogen and oxygen isotopes of these elements, these isotopes tend to dominate the transport. From the analysis presented here, the fluence peak is the result of scatter back and forth across the peak regime, and (n,2n) has a minimal (<4%) contribution. Further evidence of minimal (n,2n) impact in the 10-100 g/cm{sup 2} span includes the 1 MeV fluence peak being so much larger than the 14 MeV peak; where 1 MeV is not above the (n,2n) threshold. Also presented here is the usefulness of using tally tagging with cell flagging to further dissect the nature of the fluence. These technologies allow us to understand the originating volume that makes a contribution to a scoring regime. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Finite element modeling of nanoscale-enabled microinductors for power electronics

Here, this paper focuses on the finite element modeling of toroidal microinductors, employing first-of-its-kind nanocomposite magnetic core material and superparamagnetic iron nanoparticles covalently cross-linked in an epoxy network. Energy loss mechanisms in existing inductor core materials are covered as well as discussions on how this novel core material eliminates them providing a path toward realizing these low form factor devices. Designs for both a 2 μH output and a 500 nH input microinductor are created via the model for a high-performance buck converter. Both modeled inductors have 50 wire turns, less than 1 cm 3 form factors, less than 1 Ω AC resistance, and quality factors, Q’s, of 27 at 1 MHz. In addition, the output microinductor is calculated to have an average output power of 7 W and a power density of 3.9 kW/in 3 by modeling with the 1st generation iron nanocomposite core material.

36 MATERIALS SCIENCE↗

Analysis of MIR-18 results for physical and biological dosimetry: radiation shielding effectiveness in LEO

We compare models of radiation transport and biological response to physical and biological dosimetry results from astronauts on the Mir space station. Transport models are shown to be in good agreement with physical measurements and indicate that the ratio of equivalent dose from the Galactic Cosmic Rays (GCR) to protons is about 3/2:1 and that this ratio will increase for exposures to internal organs. Two biological response models are used to compare to the Mir biodosimetry for chromosome aberration in lymphocyte cells; a track-structure model and the linear-quadratic model with linear energy transfer (LET) dependent weighting coefficients. These models are fit to in vitro data for aberration formation in human lymphocytes by photons and charged particles. Both models are found to be in reasonable agreement with data for aberrations in lymphocytes of Mir crew members: however there are differences between the use of LET dependent weighting factors and track structure models for assigning radiation quality factors. The major difference in the models is the increased effectiveness predicted by the track model for low charge and energy ions with LET near 10 keV/micrometers. The results of our calculations indicate that aluminum shielding, although providing important mitigation of the effects of trapped radiation, provides no protective effect from the galactic cosmic rays (GCR) in low-earth orbit (LEO) using either equivalent dose or the number of chromosome aberrations as a measure until about 100 g/cm 2 of material is used.

Flight Experiment↗

A Data Quality-Aware Framework to Reliably Forecast Photovoltaic Generation and Consumer Load for an Improved Resilience of Microgrids

Photovoltaic (PV) power and consumer load forecasting plays a critical role to ensure operational resilience of the electric grid. Most data-driven forecasting algorithms rely heavily on the continuous availability of good quality data for periodic training and validation. When deployed at the grid’s edge, prolonged disruptions to communications during extreme events degrade data quality. Factors such as missing observations, epistemic uncertainties, data drift, and concept drift are manifestations of data quality that impact the generalization of such field-deployed forecasting models. Currently, there exists no mechanism in the literature to dynamically switch between models under varying degrees of data quality as quantified by certain metrics for each factor highlighted above. This paper addresses this shortcoming by conceptually introducing a data qualityaware framework for reliable PV generation and consumer load forecasting. The framework’s design incorporates components of missing values, divergence tests, and continuous monitoring of generalization performance to detect changes in data quality caused by communications disruptions and trigger specific classes of forecasting models grouped under three use cases (UC1- UC3). As a first step towards validating this framework, real data collected from an actual field microgrid system is used to demonstrate the viability of the three use cases. Results show that the performance is the best in UC1 with an unadjusted R-square value of 0.954, followed by 0.939 for UC2 and 0.757 for UC3.

Sundararajan, Aditya↗