Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Programmable devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Development of an alternating integrator for magnetic measurements for experimental advanced superconducting tokamak

A high-performance integrator is one of the key electronic devices for reliably controlling plasma in the experimental advanced superconducting tokamak for long pulse operation. We once designed an integrator system of real-time drift compensation, which has a low integration drift. However, it is not feasible for really continuous operations due to capacitive leakage error and nonlinearity error. To solve the above-mentioned problems, this paper presents a new alternating integrator. In the new integrator, the integrator system of real-time drift compensation is adopted as one integral cell while two such integral cells work alternately. To achieve the alternate function, a Field Programmable Gate Array built in the digitizer is utilized. The performance test shows that the developed integrator with the integration time constant of 20 ms has a low integration drift (<15 mV) for 1000 s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single Event Effects in FPGA Devices 2015-2016

This presentation provides an overview of single event effects in FPGA devices 2015-2016 including commercial Xilinx V5 heavy ion accelerated testing, Xilinx Kintex-7 heavy ion accelerated testing. Mitigation study, and investigation of various types of triple modular redundancy (TMR) for commercial SRAM based FPGAs.

Single Event Upset (SEU) Testing↗

Nanoscale Ferroelectric Programming of van der Waals Heterostructures

We demonstrate an approach to creating nanoscale potentials in van der Waals layers integrated with a buried programmable ferroelectric layer. Using ultra-low-voltage electron beam lithography (ULV-EBL), we can program the ferroelectric polarization in Al 1–x B x N (AlBN) thin films, generating structures with sizes as small as 35 nm. We demonstrate the ferroelectric field effect with a graphene/vdW stack on AlBN by creating a p–n junction. This resist-free, high-resolution, contactless patterning method offers a new pathway to integrate ferroelectric films with a wide range of two-dimensional layers including transition-metal dichalcogenides (TMD), enabling arbitrary programming and top-down creation of multifunctional devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strain-concentration for fast, compact photonic modulation and non-volatile memory

A critical figure of merit (FoM) for electro-optic (EO) modulators is the transmission change per voltage, d T / d V . Conventional approaches in wave-guided modulators maximize d T / d V via a high EO coefficient or longer light-material interaction lengths but are ultimately limited by material losses and nonlinearities. Optical and RF resonances improve d T / d V at the cost of spectral non-uniformity, especially for high- Q optical cavity resonances. Here, we introduce an EO modulator based on piezo-strain-concentration of a photonic crystal cavity to address both trade-offs: (i) it eliminates the trade-off between d T / d V and waveguide loss—i.e., enhancement of the resonance tuning efficiency d v c / d V for the fixed EO coefficient, waveguide length, and cavity Q —and (ii) at high DC strains it exhibits a non-volatile (NV) cavity tuning Δ v c ,NV for passive memory and programming of multiple devices into resonance despite fabrication variations. The device is fabricated on a scalable silicon nitride-on-aluminum nitride platform. We measure d v c / d V =177±1MHz/V, corresponding to Δ v c =40±0.32GHz for a voltage spanning ±120V with an energy consumption of δ U /Δ v c =0.17nW/GHz. The modulation bandwidth is flat up to ω BW,3dB /2 π =3.2±0.07MHz for broadband DC-AC and 142±17MHz for resonant operation near a 2.8 GHz mechanical resonance. Optical extinction up to 25 dB is obtained via Fano-type interference. Strain-induced beam-buckling modes are programmable under a “read-write” protocol with a continuous, repeatable tuning range of 5±0.25GHz, allowing for storage and retrieval, which we quantify with mutual information of 2.4 bits and a maximum non-volatile excursion of 8 GHz. Using a full piezo-optical finite-element-model (FEM) we identify key design principles for optimizing strain-based modulators and chart a path towards achieving performance comparable to lithium niobate-based modulators and the study of high strain physics on-chip.

Wen, Y. Henry (ORCID:0009000685423628)↗

Entropy Analysis of FPGA Interconnect and Switch Matrices for Physical Unclonable Functions

Random variations in microelectronic circuit structures represent the source of entropy for physical unclonable functions (PUFs). In this paper, we investigate delay variations that occur through the routing network and switch matrices of a field-programmable gate array (FPGA). The delay variations are isolated from other components of the programmable logic, e.g., look-up tables (LUTs), flip-flops (FFs), etc., using a feature of Xilinx FPGAs called dynamic partial reconfiguration (DPR). A set of partial designs is created to fix the placement of a time-to-digital converter (TDC) and supporting infrastructure to enable the path delays through the target interconnect and switch matrices to be extracted by subtracting out common-mode delay components. Delay variations are analyzed in the different levels of routing resources available within FPGAs, i.e., local routing and across-chip routing. Data are collected from a set of Xilinx Zynq 7010 devices, and a statistical analysis of within-die variations in delay through a set of the randomly-generated and hand-crafted interconnects is presented.

97 MATHEMATICS AND COMPUTING↗

Novel Advancements in Internet-Based Real Time Data Technologies

AZ Technology has been working with MSFC Ground Systems Department to find ways to make it easier for remote experimenters (RPI's) to monitor their International Space Station (ISS) payloads in real-time from anywhere using standard/familiar devices. AZ Technology was awarded an SBIR Phase I grant to research the technologies behind and advancements of distributing live ISS data across the Internet. That research resulted in a product called "EZStream" which is in use on several ISS-related projects. Although the initial implementation is geared toward ISS, the architecture and lessons learned are applicable to other space-related programs. This paper presents the high-level architecture and components that make up EZStream. A combination of commercial-off-the-shelf (COTS) and custom components were used and their interaction will be discussed. The server is powered by Apache's Jakarta-Tomcat web server/servlet engine. User accounts are maintained in a My SQL database. Both Tomcat and MySQL are Open Source products. When used for ISS, EZStream pulls the live data directly from NASA's Telescience Resource Kit (TReK) API. TReK parses the ISS data stream into individual measurement parameters and performs on-the- fly engineering unit conversion and range checking before passing the data to EZStream for distribution. TReK is provided by NASA at no charge to ISS experimenters. By using a combination of well established Open Source, NASA-supplied. and AZ Technology-developed components, operations using EZStream are robust and economical. Security over the Internet is a major concern on most space programs. This paper describes how EZStream provides for secure connection to and transmission of space- related data over the public Internet. Display pages that show sensitive data can be placed under access control by EZStream. Users are required to login before being allowed to pull up those web pages. To enhance security, the EZStream client/server data transmissions can be encrypted to preclude interception. EZStream was developed to make use of a host of standard platforms and protocols. Each are discussed in detail in this paper. The I3ZStream server is written as Java Servlets. This allows different platforms (i.e. Windows, Unix, Linux . Mac) to host the server portion. The EZStream client component is written in two different flavors: JavaBean and ActiveX. The JavaBean component is used to develop Java Applet displays. The ActiveX component is used for developing ActiveX-based displays. Remote user devices will be covered including web browsers on PC#s and scaled-down displays for PDA's and smart cell phones. As mentioned. the interaction between EZStream (web/data server) and TReK (data source) will be covered as related to ISS. EZStream is being enhanced to receive and parse binary data stream directly. This makes EZStream beneficial to both the ISS International Partners and non-NASA applications (i.e. factory floor monitoring). The options for developing client-side display web pages will be addressed along with the development of tools to allow creation of display web pages by non-programmers.

Myers, Gerry↗

XML Translator for Interface Descriptions

A computer program defines an XML schema for specifying the interface to a generic FPGA from the perspective of software that will interact with the device. This XML interface description is then translated into header files for C, Verilog, and VHDL. User interface definition input is checked via both the provided XML schema and the translator module to ensure consistency and accuracy. Currently, programming used on both sides of an interface is inconsistent. This makes it hard to find and fix errors. By using a common schema, both sides are forced to use the same structure by using the same framework and toolset. This makes for easy identification of problems, which leads to the ability to formulate a solution. The toolset contains constants that allow a programmer to use each register, and to access each field in the register. Once programming is complete, the translator is run as part of the make process, which ensures that whenever an interface is changed, all of the code that uses the header files describing it is recompiled.

Boroson, Elizabeth R.↗

Mesoporous Thin Film Architectures: Addressing Material Demands through Molecular Self-Assembly

Mesoporous thin films spark interest across a wide range of disciplines due to their tunable nanostructures, large internal surface areas, and strong compatibility with planar optical, electronic, and microfluidic devices. While attention in the porous materials community has shifted toward macroporous or disordered nanoporous systems, a resurgence in mesoporous thin film research is underway, driven by new molecular self-assembly methods, advanced materials chemistry, and improved characterization techniques. The integration of high-χN block copolymer design, kinetically persistent micelle templating, and postdeposition processing protocols now allows control over structural parameters such as pore size, wall thickness, porosity, and connectivity. These advances have overcome many of the thermodynamic and processing constraints that previously limited widespread adoption. Rather than serving only as high-surface-area supports, mesoporous thin films are engineered as active interfaces where responsive chemistries and nanoscale confinement act in tandem. Embedding switchable ligands, thermoresponsive polymers, redox mediators, or ion-selective groups directly within the pore walls enables real-time control over transport, optical, and electrochemical properties. These capabilities open up new directions in adaptive coatings, gated membranes, and fast-response biosensors. To further expand their functional scope, mesoporous films are integrated into hierarchical and multicomponent architectures. Techniques such as triblock terpolymer templating, crack-directed assembly, and nanoimprint lithography allow for control over spatial organization on the micron and submicron scale and pore system orientation. This enables programmable anisotropy, enhanced molecular diffusion, and wavelength-selective photonic behavior, essential for next-generation sensing, catalysis, and energy applications. Such structural and functional complexity requires equally sophisticated characterization. Multimodal and in situ techniques can track material dynamics under operational conditions. Recent progress includes extended-range ellipsometric porosimetry (EP) for hierarchical architectures, vacuum EP for interface energetics, time-resolved EP for diffusion kinetics, and correlative AFM-SAXS mapping. The introduction of advanced neutron-based spectroscopies, particularly quasielastic neutron scattering (QENS), promises to provide real-time access to ion transport dynamics and segmental motion under nanoscale confinement, offering a path toward deeper mechanistic understanding of structure-performance correlations in mesoporous systems. This Account reflects the technical advances made and the interdisciplinary collaborations that have shaped our collective vision. The particular dimensions of mesopores enable us to subtly tune interactions at the molecular, interfacial, and mesoscopic levels that permit us to harness nanoconfinement. What emerges is a versatile, modular platform capable of chemical gating, energy transduction, and sensing with a level of tunability unmatched by other porous materials. We highlight critical challenges including the need for more robust large-area processing, a deeper understanding of dynamic behavior under cycling, and better integration with device-level architectures. Our strategies support the transition of mesoporous thin films into active high-performance components in next-generation energy, environmental, and biomedical systems.

oxides↗

High-speed, multi-channel detector readout electronics for fast radiation detectors

In this project, we are developing a high speed digital spectrometer that a) captures detector waveforms at rates up to 500 MSPS b) has upgraded event data acquisition with additional data buffers for zero dead time operation c) moves energy calculations to the FPGA to increase spectrometer throughput in fast scintillator applications d) uses a streamlined architecture and high speed data interface for even faster readout to the host PC These features are in addition to the standard functions in our existing spectrometers such as digitization, programmable trigger and energy filters, pileup inspection, data acquisition with energy and time stamps, MCA histograms, and run statistics. In Phase I, we upgraded one of our existing spectrometer designs to demonstrate the key principle of fast waveform capture using a 500 MSPS, 12 bit ADC and a Xilinx Virtex-4 FPGA. This upgraded spectrometer, named P500, performed well in initial tests of energy resolution, pulse shape analysis, and timing measurements, thus achieving item (a) above. In Phase II, we are revising the P500 to build a commercial prototype with the improvements listed in items (b)-(d). As described in the previous report, two devices were built to pursue this goal, named the Pixie-500 and the Pixie-500 Express. The Pixie-500 has only minor improvements from the Phase I prototype and is intended as an early commercial product (its production and part of its development were funded outside the SBIR). It also allows testing of the ADC performance in real applications.The Pixie-500 Express (or Pixie-500e) includes all of the improvements (b)-(d). At the end of Phase II of the project, we have tested and debugged the hardware, firmware and software of the Pixie-500 Express prototype boards delivered 12/3/2010. This proved substantially more complex than anticipated. At the time of writing, all hardware bugs have been fixed, the PCI Express interface is working, the SDRAM has been successfully tested and the SHARC DSP has been booted with preliminary code. All new ICs and circuitry on the prototype are working properly, however some of the planned firmware and software functions have not yet been completely implemented and debugged. Overall, due to the unanticipated complexity of the PCI Express interface, some aspects of the project could not be completed with the time and funds available in Phase II. These aspects will be completed in self-funded Phase III.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of the EUROfusion Tokamak Exploitation programme in support of ITER and DEMO

Within the 9th European Framework programme, since 2021 EUROfusion is operating five tokamaks under the auspices of a single Task Force called ‘Tokamak Exploitation’. The goal is to benefit from the complementary capabilities of each machine in a coordinated way and help in developing a scientific output scalable to future largre machines. The programme of this Task Force ensures that ASDEX Upgrade, MAST-U, TCV, WEST and JET (since 2022) work together to achieve the objectives of Missions 1 and 2 of the EUROfusion Roadmap: i) demonstrate plasma scenarios that increase the success margin of ITER and satisfy the requirements of DEMO and, ii) demonstrate an integrated approach that can handle the large power leaving ITER and DEMO plasmas. The Tokamak Exploitation task force has therefore organized experiments on these two missions with the goal to strengthen the physics and operational basis for the ITER baseline scenario and for exploiting the recent plasma exhaust enhancements in all four devices (PEX: Plasma EXhaust) for exploring the solution for handling heat and particle exhaust in ITER and develop the conceptual solutions for DEMO. The ITER Baseline scenario has been developed in a similar way in ASDEX Upgrade, TCV and JET. Key risks for ITER such as disruptions and run-aways have been also investigated in TCV, ASDEX Upgrade and JET. Experiments have explored successfully different divertor configurations (standard, super-X, snowflakes) in MAST-U and TCV and studied tungsten melting in WEST and ASDEX Upgrade. The input from the smaller devices to JET has also been proven successful to set-up novel control schemes on disruption avoidance and detachment.

ASDEX upgrade↗

Contrast Measurements of the Microshutter Arrays for the NIRspec

We have been developing programmable microshutter arrays for the Near Infrared Spectrometer (NIRSpec) on the James Webb Space telescope (JWST). These arrays are an enabling technology that allows to turn NIRSpec into a powerful multi-object spectrometer and tremendously increase its efficiency. The arrays are essentially 2D programmable masks that are designed to operate at cryogenic temperatures of JWST. The primary optical characteristic of the microshutter array is a contrast, that is defined as a ratio of the transmitted light intensity through open shutters to the intensity of the transmitted light through the closed shutters. To eliminate the noise and confusion from other sources in the field of view and therefore to improve the detection limit, the contrast provided by the microshutter array should be very high, with the goal of 10,000. The test system that we have developed specifically for the purpose of the high contrast characterization of the microshutter array devices has been used to test several microshutter arrays. It is capable of measuring contrast values of up to 10^5 and therefore can reliably measure contrast values of the arrays that satisfy the requirements. The arrays have been characterized for the contrast ratio and its behavior with temperature and other array operating parameters. The arrays that we have tested meet or exceed the NiRSpec requirements.

Kutyrev, Alexander↗

SU-E-T-163: Characterization of a Novel High Resolution 1D Silicon Monolithic Array for Small Field Commissioning and Quality Assurance

Purpose: To study the suitability of a novel 1D silicon monolithic array for dosimetry of small radiation fields and for QA of high dose gradient treatment modalities (IMRT and SBRT). Methods: A 1D array composed of 4 monolithic silicon modules of 64 mm length and 1 mm pixel pitch was developed by IBA Dosimetry. Measurements were carried out for 6MV and 15MV photons on two commercial different linacs (TrueBeam and Clinac iX, Varian Medical Systems, Palo Alto, CA) and for a CyberKnife G4 (Accuray Inc., Sunnyvale, CA). The 1D array was used to measure output factors (OF), profiles and off axis correction factors (OACF) for the Iris CyberKnife variable collimator (5–60 mm). In addition, dose profiles (at the isocenter plane) were measured for multiple IMRT and SBRT treatment plans and compared with those obtained using EDR2radiographic film (Carestream Health, Rochester NY), a commercial 2D diode array and with the dose distribution calculated using a commercial TPS (Eclipse, Varian Medical Systems, Palo Alto, CA). Results: Due to the small pixel pitch of the detector, IMRT and SBRT plan profiles deviate from film measurements by less than 2%. Similarly, the 1D array exhibits better performance than the 2D diode array due to the larger (7 mm) pitch of that device. Iris collimator OFs measured using the 1D silicon array are in good agreement with the commissioning values obtained using a commercial stereotactic diode as well as with published data. Maximum deviations are < 3% for the smallest field (5 and 7.5mm) and below 1% for all other dimensions. Conclusion: We have demonstrated good performances of the array for commissioning of small photon fields and in patient QA, compared with diodes and film typically used in these clinical applications. The technology compares favorably with existing commercial solutions The presenting author is founded by a Marie Curie Early Initial Training Network Fellowship of the European Communitys Seventh Framework Programme under contract number (PITN-GA-2011-289198-ARDENT). The research activity is hosted by IBA Dosimetry, Gmbh.

60 APPLIED LIFE SCIENCES↗

Evaluation of a Programmable Voltage-Controlled MEMS Oscillator, Type SiT3701, Over a Wide Temperature Range

Semiconductor chips based on MEMS (Micro-Electro-Mechanical Systems) technology, such as sensors, transducers, and actuators, are becoming widely used in today s electronics due to their high performance, low power consumption, tolerance to shock and vibration, and immunity to electro-static discharge. In addition, the MEMS fabrication process allows for the miniaturization of individual chips as well as the integration of various electronic circuits into one module, such as system-on-a-chip. These measures would simplify overall system design, reduce parts count and interface, improve reliability, and reduce cost; and they would meet requirements of systems destined for use in space exploration missions. In this work, the performance of a recently-developed MEMS voltage-controlled oscillator was evaluated under a wide temperature range. Operation of this new commercial-off-the-shelf (COTS) device was also assessed under thermal cycling to address some operational conditions of the space environment

Patterson, Richard↗

On Polymorphic Circuits and Their Design Using Evolutionary Algorithms

This paper introduces the concept of polymorphic electronics (polytronics) - referring to electronics with superimposed built-in functionality. A function change does not require switches/reconfiguration as in traditional approaches. Instead the change comes from modifications in the characteristics of devices involved in the circuit, in response to controls such as temperature, power supply voltage (VDD), control signals, light, etc. The paper illustrates polytronic circuits in which the control is done by temperature, morphing signals, and VDD respectively. Polytronic circuits are obtained by evolutionary design/evolvable hardware techniques. These techniques are ideal for the polytronics design, a new area that lacks design guidelines, know-how,- yet the requirements/objectives are easy to specify and test. The circuits are evolved/synthesized in two different modes. The first mode explores an unstructured space, in which transistors can be interconnected freely in any arrangement (in simulations only). The second mode uses a Field Programmable Transistor Array (FPTA) model, and the circuit topology is sought as a mapping onto a programmable architecture (these experiments are performed both in simulations and on FPTA chips). The experiments demonstrated the synthesis. of polytronic circuits by evolution. The capacity of storing/hiding "extra" functions provides for watermark/invisible functionality, thus polytronics may find uses in intelligence/security applications.

Stoica, Adrian↗

Lessons Learned in Over a Decade of Technical Support for U.S. Nuclear Cyber Security Programmes

Pacific Northwest National Laboratory’s (PNNL) nuclear cyber security team has been providing technical support to the U.S. Nuclear Regulatory Commission (NRC) since 2002. This team has provided cyber security technical experties in conducting cyber security inspections, developing of regulatory rules and guidance, reviewing facility cyber security plans, developing inspection guidance, and developing and teaching NRC inspectors how to conduct cyber security assessments. The extensive experience the PNNL team has gathered has allowed them to compile a lenghty list of recommendations on how to improve cyber security programs and conduct assessments. A selected set of recommendations are presented, including the need to: integrate an array of defenisve strategies into a facility’s cyber security program, coordinate physical and cyber security activities, train phycial security forces to resist a cyber-enabled physical attack, improve estimates of the consequences of a cyber attack, properly resource cyber security assessments, appropropriately account for insider threats, routinely monitor security devices for potential attacks, supplement compliance-based requirements with risk-based decision making, and introduce the concept of resilience into cyber security programs.

Glantz, Clifford S.↗

Creating tuneable microwave media from a two-dimensional lattice of re-entrant posts

The potential capabilities of resonators based on two dimensional arrays of re-entrant posts is demonstrated. Such posts may be regarded as magnetically coupled lumped element microwave harmonic oscillators, arranged in a 2D lattices structure, which is enclosed in a 3D cavity. By arranging these elements in certain 2D patterns, we demonstrate how to achieve certain requirements with respect to field localisation and device spectra. Special attention is paid to symmetries of the lattices, mechanical tuning, design of areas of high localisation of magnetic energy; this in turn creates unique discrete mode spectra. We demonstrate analogies between systems designed on the proposed platform and well known physical phenomena such as polarisation, frustration, and Whispering Gallery Modes. The mechanical tunability of the cavity with multiple posts is analysed, and its consequences to optomechanical applications is calculated. One particular application to quantum memory is demonstrated with a cavity design consisting of separate resonators analogous to discrete Fabry–Pérot resonators. Finally, we propose a generalised approach to a microwave system design based on the concept of Programmable Cavity Arrays.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic-Scale Manipulation and In Situ Characterization with Scanning Tunneling Microscopy

Scanning tunneling microscope (STM) has presented a revolutionary methodology to nanoscience and nanotechnology. It enables imaging of the topography of surfaces, mapping the distribution of electronic density of states, and manipulating individual atoms and molecules, all at atomic resolutions. In particular, atom manipulation capability has evolved from fabricating individual nanostructures toward the scalable production of the atomic-sized devices bottom-up. The combination of precision synthesis and in situ characterization has enabled direct visualization of many quantum phenomena and fast proof-of-principle testing of quantum device functions with immediate feedback to guide improved synthesis. Several representative examples are reviewed to demonstrate the recent development of atomic-scale manipulation, focusing on progress that addresses quantum properties by design in several technologically relevant materials systems. Integration of several atomically precisely controlled probes in a multiprobe STM system vastly extends the capability of in situ characterization to a new dimension where the charge and spin transport behaviors can be examined from mesoscopic to atomic length scale. The automation of atomic-scale manipulation and the integration with well-established lithographic processes further push this bottom-up approach to a new level that combines reproducible fabrication, extraordinary programmability, and the ability to produce large-scale arrays of quantum structures.

47 OTHER INSTRUMENTATION↗

Develop On-Demand nanoplasmonic Device Concepts in a Semiconductor Compatible Hybrid System. Final Report

This report summarizes the research activities supported by the U.S. Department of Energy grant DE-SC-0010399. The goal of this project is to is to develop an on-demand nanoplasmonic platform that combines emerging oxide nanoelectronics with a low-loss semiconductor-friendly plasmonic materials. Toward this goal, several unique heterostructures formed between complex oxides and 2D layered materials have been developed. Based on these material systems, a set of atomic force microscope (AFM) based techniques have been developed that can allow long-living and reversible material phase transitions to be manipulated in nanoscale at room temperature. Using such technique and through interface coupling, we can effectively tune the plasmon propagations in unconventional plasmonic materials such as graphene and VO 2 . In addition, we also discovered a plethora of novel interface enabled electro-optic effects, including the spatial modulation of light using 2DEG, a giant programmable photothermoelectric effects at room temperature, a light induced superconducting transition, and a tunable giant third order optical nonlinearities. These major results are outlined in this report, along with lists of project participants and products.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗