Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Practice Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Hydrogen-Bonding Interactions in Hybrid Aqueous/Nonaqueous Electrolytes Enable Low-Cost and Long-Lifespan Sodium-Ion Storage

Although “water-in-salt” electrolytes have opened a new pathway to expand the electrochemical stability window of aqueous electrolytes, the electrode instability and irreversible proton co-insertion caused by aqueous media still hinder the practical application, even when using exotic fluorinated salts. In this study, an accessible hybrid electrolyte class based on common sodium salts is proposed, and crucially an ethanol-rich media is introduced to achieve highly stable Na-ion electrochemistry. Here, ethanol exerts a strong hydrogen-bonding effect on water, simultaneously expanding the electrochemical stability window of the hybridized electrolyte to 2.5 V, restricting degradation activities, reducing transition metal dissolution from the cathode material, and improving electrolyte–electrode wettability. The binary ethanol–water solvent enables the impressive cycling of sodium-ion batteries based on perchlorate, chloride, and acetate electrolyte salts. Notably, a Na 0.44 MnO 2 electrode exhibits both high capacity (81 mAh g –1 ) and a remarkably long cycle life >1000 cycles at 100 mA g –1 (a capacity decay rate per cycle of 0.024%) in a 1 M sodium acetate system. The Na 0.44 MnO 2 /Zn full cells also show excellent cycling stability and rate capability in a wide temperature range. The gained understanding of the hydrogen-bonding interactions in the hybridized electrolyte can provide new battery chemistry guidelines in designing promising candidates for developing low-cost and long-lifespan batteries based on other (Li + , K + , Zn 2+ , Mg 2+ , and Al 3+ ) systems.

25 ENERGY STORAGE↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Upland tidal brackish marsh specific conductivity and salinity measurements, PIE LTER, Plum Island Sound, MA, 2023

This dataset includes raw and corrected specific conductivity, temperature, and calculated salinity measurements collected at 10 cm depth in a Typha angustifolia-dominated tidal brackish wetland at the upper estuary of Plum Island Sound in Newbury, Massachusetts (MA) within the Plum Island Ecosystems Long Term Ecological Research (PIE LTER) site. Measurements were taken to evaluate temporal variation in porewater salinity (a proxy for porewater sulfate concentration) in high frequency to assess soil and plant responses to changes in salinity. Measurements were collected using an Onset HOBO U24-002 Saltwater Conductivity/Salinity data logger deployed in a well. Specific conductivity was corrected using non-linear temperature compensation, and salinity was calculated using the Practical Salinity Scale 1978 via Onset's HOBOware software. Reference conductivity measurements to correct for sensor drift were taken at the start and end of each deployment using a HACH HQ14D Portable Conductivity Meter. Data were then filtered in MATLAB to remove values logged while the sensor was out of the well or during post-deployment equilibration. Detailed metadata, including variable descriptions, sampling methods, QA/QC procedures, and site information, are provided in the files: Typha_ctd_salinity_dd.csv and Typha_MI_ctd_salinity_2023_flmd.csv.

54 ENVIRONMENTAL SCIENCES↗

Upland tidal brackish marsh specific conductivity and salinity measurements, PIE LTER, Plum Island Sound, MA, May-December 2022

This dataset includes raw and corrected specific conductivity, temperature, and calculated salinity measurements collected at 10 cm depth in a Typha angustifolia-dominated tidal brackish wetland at the upper estuary of Plum Island Sound in Newbury, Massachusetts (MA) within the Plum Island Ecosystems Long Term Ecological Research (PIE LTER) site. Measurements were taken to evaluate temporal variation in porewater salinity (a proxy for porewater sulfate concentration) in high frequency to assess soil and plant responses to changes in salinity. Measurements were collected using an Onset HOBO U24-002 Saltwater Conductivity/Salinity data logger deployed in a well. Specific conductivity was corrected using non-linear temperature compensation, and salinity was calculated using the Practical Salinity Scale 1978 via Onset's HOBOware software. Reference conductivity measurements to correct for sensor drift were taken at the start and end of each deployment using a HACH HQ14D Portable Conductivity Meter. Data were then filtered in MATLAB to remove values logged while the sensor was out of the well or during post-deployment equilibration. Detailed metadata, including variable descriptions, sampling methods, QA/QC procedures, and site information, are provided in the files: Typha_ctd_salinity_dd.csv and Typha_MI_ctd_salinity_2023_flmd.csv.

54 ENVIRONMENTAL SCIENCES↗

Heart-sparing radiotherapy in patients with breast cancer: What are the techniques used in the clinical routine?

The aim of this study was to understand the practice of care in German-speaking countries with regard to heart-sparing radiotherapy techniques. Between August 2015 and September 2015, an e-mail/fax-based survey was sent to radiation oncology departments in Germany, Austria, and the German-speaking Switzerland. The questionnaire was divided into 3 chapters: a general chapter on the department, a chapter specific for heart-sparing techniques in patients with breast cancer, and a third chapter on personal beliefs on the topic of heart sparing in patients with breast cancer. A total of 82 radiation oncology departments answered the questionnaire: 16 university clinics and 66 other departments. In general, heart-sparing techniques are being offered by 90.2% of departments for radiation oncology in the German-speaking countries. However, in the clinical routine, 87.7% of institutions use heart-sparing techniques in less than 50% of patients with breast cancer. Heart-sparing techniques are especially provided for patients with left-sided breast cancer (80%), patients after mastectomy (52.5%), and when the mammaria interna lymph drainage vessels are irradiated (41.3%). In 46.3% of departments, there are written internal guidelines for heart sparing in patients with breast cancer. Breathing-adapted radiotherapy is used as the most frequent heart-sparing technique in 64.7% of the institutions, followed by intensity-modulated radiation therapy, which is most frequently used by 22.1%. The only significant difference between university hospitals and other departments was seen for the offering of partial breast irradiation. The most commonly used heart-sparing technique is breathing-adapted radiotherapy, but there is no coherent approach for heart sparing in patients with breast cancer in the German-speaking countries. Overall, all options for cardiac protection/cardiac avoidance have their advantages and disadvantages, with deep inspiration breath-hold radiotherapyhaving the most clear data, which should be the preferred choice when using heart-sparing techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Exploring the Light-induced Dynamics in Solvated Metallogrid Complexes with Femtosecond Pulses Across the Electromagnetic Spectrum

Oligonuclear complexes of d 4 -d 7 transition metal ion centers that undergo spin-switching have long been developed for their practical role in molecular electronics. Recently, they also have appeared as promising photochemical reactants demonstrating improved stability. However, the lack of knowledge about their photophysical properties in the solution phase compared to their mononuclear congeners is currently hampering their inclusion into advanced light-driven reactions. In the present study, the ultrafast photoinduced dynamics in a solvated [2x2] iron(II) metallogrid complex are characterized by combining transient optical, infrared absorption and X-ray emission spectroscopic measurements on the femtosecond timescale. The analysis is supported by DFT calculations. The photocycle can be described in terms of intra-site transitions, where the Fe II in the low-spin (LS) state are independently photoexcited. The Franck-Condon state decays via the formation of a vibrationally-hot high-spin (HS) state that displays coherent behavior within a few picoseconds and thermalizes within tens of picosecond to yield a metastable HS state living for several hundreds of nanoseconds. Additionally, systematic comparison with the closely related mononuclear complex [Fe(terpy) 2 ] 2+ reveals that nuclearity has a profound impact on the photoinduced dynamics. Finally, this work provides guidelines for expanding the integration of oligonuclear complexes into new photoconversion schemes that may be triggered by ultrafast spin-switching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Antiflatulent Dietary Advice on Intrafraction Motion for Prostate Cancer Radiotherapy

Purpose: To evaluate the effect of an antiflatulent dietary advice on the intrafraction prostate motion in patients treated with intensity-modulated radiotherapy (IMRT) for prostate cancer. Methods and Materials: Between February 2002 and December 2009, 977 patients received five-beam IMRT for prostate cancer to a dose of 76 Gy in 35 fractions combined with fiducial markers for position verification. In July 2008, the diet, consisting of dietary guidelines to obtain regular bowel movements and to reduce intestinal gas by avoiding certain foods and air swallowing, was introduced to reduce the prostate motion. The intrafraction prostate movement was determined from the portal images of the first segment of all five beams. Clinically relevant intrafraction motion was defined as {>=}50% of the fractions with an intrafraction motion outside a range of 3 mm. Results: A total of 739 patients were treated without the diet and 105 patients were treated with radiotherapy after introduction of the diet. The median and interquartile range of the average intrafraction motion per patient was 2.53 mm (interquartile range, 2.2-3.0) without the diet and 3.00 mm (interquartile range, 2.4-3.5) with the diet (p < .0001). The percentage of patients with clinically relevant intrafraction motion increased statistically significant from 19.1% without diet to 42.9% with a diet (odds ratio, 3.18; 95% confidence interval, 2.07-4.88; p < .0001). Conclusions: The results of the present study suggest that antiflatulent dietary advice for patients undergoing IMRT for prostate cancer does not reduce the intrafraction movement of the prostate. Therefore, antiflatulent dietary advice is not recommended in clinical practice for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

U.S. Department of Energy Office of Legacy Management Legacy Uranium Mine Site Reclamation - Lessons Learned - 12384

The U.S. Department of Energy (DOE) Office of Legacy Management is responsible for administering the DOE Uranium Leasing Program (ULP) and its 31 uranium lease tracts located in the Uravan Mineral Belt of southwestern Colorado (see Figure 1). In addition to administering the ULP for the last six decades, DOE has also undertaken the significant task of reclaiming a large number of abandoned uranium (legacy) mine sites and associated features located throughout the Uravan Mineral Belt. In 1995, DOE initiated a 3-year reconnaissance program to locate and delineate (through extensive on-the-ground mapping) the legacy mine sites and associated features contained within the historically defined boundaries of its uranium lease tracts. During that same time frame, DOE recognized the lack of regulations pertaining to the reclamation of legacy mine sites and contacted the U.S. Bureau of Land Management (BLM) concerning the reclamation of legacy mine sites. In November 1995, The BLM Colorado State Office formally issued the United States Department of the Interior, Colorado Bureau of Land Management, Closure/Reclamation Guidelines, Abandoned Uranium Mine Sites as a supplement to its Solid Minerals Reclamation Handbook (H-3042-1). Over the next five-and-one-half years, DOE reclaimed the 161 legacy mine sites that had been identified on DOE withdrawn lands. By the late 1990's, the various BLM field offices in southwestern Colorado began to recognize DOE's experience and expertise in reclaiming legacy mine sites. During the ensuing 8 years, BLM funded DOE (through a series of task orders) to perform reclamation activities at 182 BLM mine sites. To date, DOE has reclaimed 372 separate and distinct legacy mine sites. During this process, DOE has learned many lessons and is willing to share those lessons with others in the reclamation industry because there are still many legacy mine sites not yet reclaimed. DOE currently administers 31 lease tracts (11,017 ha) that collectively contain over 220 legacy (abandoned) uranium mine sites. This contrasts to the millions of hectares administered by the BLM, the U.S. Forest Service, and other federal, tribal, and state agencies that contain thousands of such sites. DOE believes that the processes it has used provide a practical and cost-effective approach to abandoned uranium mine-site reclamation. Although the Federal Acquisition Regulations preclude DOE from competing with private industry, DOE is available to assist other governmental and tribal agencies in their reclamation efforts. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Pattern of Use of Hypofractionated Radiation Therapy for Early-Stage Breast Cancer in New South Wales, Australia, 2008 to 2012

Purpose: Increasing phase 3 evidence has been published about the safety and efficacy of hypofractionated radiation therapy, in comparison with standard fractionation, in early-stage, node-negative breast cancer. However, uptake of hypofractionation has not been universal. The aim of this study was to investigate the hypofractionation regimen variations in practice across public radiation oncology facilities in New South Wales (NSW). Methods and Materials: Patients with early breast cancer registered in the NSW Clinical Cancer Registry who received radiation therapy for early-stage breast cancer in a publicly funded radiation therapy department between 2008 and 2012 were identified. Data extracted and analyzed included dose and fractionation type, patient age at first fraction, address (for geocoding), year of diagnosis, year of treatment, laterality, and department of treatment. A logistic regression model was used to identify factors associated with fractionation type. Results: Of the 5880 patients fulfilling the study criteria, 3209 patients (55%) received standard fractionation and 2671 patients (45%) received hypofractionation. Overall, the use of hypofractionation increased from 37% in 2008 to 48% in 2012 (range, 7%-94% across departments). Treatment facility and the radiation oncologist prescribing the treatment were the strongest independent predictors of hypofractionation. Weaker associations were also found for age, tumor site laterality, year of treatment, and distance to facility. Conclusions: Hypofractionated regimens of whole breast radiation therapy have been variably administered in the adjuvant setting in NSW despite the publication of long-term trial results and consensus guidelines. Some factors that predict the use of hypofractionation are not based on guideline recommendations, including lower rates of left-sided treatment and increasing distance from a treatment facility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-201-13: Investigation of Dose Variation Induced by HDR Ir-192 Source Global Shift Within the Varian Ring Applicator Using Monte Carlo Methods

Purpose: The Varian tandem and ring applicators are used to deliver HDR Ir-192 brachytherapy for cervical cancer. The source path within the ring is hard to predict due to the larger interior ring lumen. Some studies showed the source could be several millimeters different from planned positions, while other studies demonstrated minimal dosimetric impact. A global shift can be applied to limit the effect of positioning offsets. The purpose of this study was to assess the necessities of implementing a global source shift using Monte Carlo (MC) simulations. Methods: The MCNP5 radiation transport code was used for all MC simulations. To accommodate TG-186 guidelines and eliminate inter-source attenuation, a BrachyVision plan with 10 dwell positions (0.5cm step sizes) was simulated as the summation of 10 individual sources with equal dwell times for simplification. To simplify the study, the tandem was also excluded from the MC model. Global shifts of ±0.1, ±0.3, ±0.5 cm were then simulated as distal and proximal from the reference positions. Dose was scored in water for all MC simulations and was normalized to 100% at the normalization point 0.5 cm from the cap in the ring plane. For dose comparison, Point A was 2 cm caudal from the buildup cap and 2 cm lateral on either side of the ring axis. With seventy simulations, 108 photon histories gave a statistical uncertainties (k=1) <2% for (0.1 cm)3 voxels. Results: Compared to no global shift, average Point A doses were 0.0%, 0.4%, and 2.2% higher for distal global shifts, and 0.4%, 2.8%, and 5.1% higher for proximal global shifts, respectively. The MC Point A doses differed by < 1% when compared to BrachyVision. Conclusion: Dose variations were not substantial for ±0.3 cm global shifts, which is common in clinical practice.

60 APPLIED LIFE SCIENCES↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report)

Project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. The overarching objective of this program is to improve photovoltaic (PV) module reliability via development of tests and standards. Where reliability problems or risk are discovered, we can design tests to ensure that these liabilities don't affect future generations of products. Customers can use these tests to understand which products are susceptible to certain degradation mechanisms, and manufacturers can use the tests to design unwanted characteristics out of their products. The work under this program identifies PV reliability needs, performs characterization that provides scientific understanding of targeted degradation mechanisms, and translates those data into practical and predictive test protocols and standards. Major accomplishments include: A model for polarization-type potential induced degradation (PID-p) was developed and validated against experimental data. NREL is currently leading a new edition of IEC 62804-1 for PID detection. PID-p can cause large losses in current and voltage for some module designs on cloudy days. Finite element modeling (FEM) and experiment was used to determine when cells crack in a module. It was shown that cells in landscape orientation are much more likely to crack than those on portrait orientation. Shortly thereafter, the first products with portrait-oriented cells were introduced. Studies of how to test for light and elevated temperature degradation (LeTID) culminated with the publication of IEC TS 63342. Software to predict the progression of LeTID was developed, validated, and made publicly available. Field validated tests and international standards for durability of PV module coatings abrasion, backsheets, and encapsulants were developed. Examples are IEC 62788-1-1, IEC 62788-2 ED2, IEC TS 62788-7-2, IEC 62788-7-3 ED1, IEC 63209-2. NREL led the development a high-temperature testing technical specification, and published guidelines that enable installers to determine whether higher-temperature testing is needed, simply based on location and mounting configuration. In a number of our case studies, variations in the bills of materials or workmanship have been associated with variations in reliability. These observations emphasize the importance of quality assurance to reliability. A framework for criticality (i.e. Pareto) analysis was developed and published. The framework helps us and other researchers determine what problems should be addressed for reliability research to have the biggest industry impact. NREL continues to participate actively in international standards development and stakeholder engagement activities, including organizing an annual PV Reliability Workshop. These activities are important for ensuring we address issues that are relevant and timely, and that we convey our results to those who may benefit.

14 SOLAR ENERGY↗

Advancing Fusion with Machine Learning Research Needs Workshop Report

Abstract Machine learning and artificial intelligence (ML/AI) methods have been used successfully in recent years to solve problems in many areas, including image recognition, unsupervised and supervised classification, game-playing, system identification and prediction, and autonomous vehicle control. Data-driven machine learning methods have also been applied to fusion energy research for over 2 decades, including significant advances in the areas of disruption prediction, surrogate model generation, and experimental planning. The advent of powerful and dedicated computers specialized for large-scale parallel computation, as well as advances in statistical inference algorithms, have greatly enhanced the capabilities of these computational approaches to extract scientific knowledge and bridge gaps between theoretical models and practical implementations. Large-scale commercial success of various ML/AI applications in recent years, including robotics, industrial processes, online image recognition, financial system prediction, and autonomous vehicles, have further demonstrated the potential for data-driven methods to produce dramatic transformations in many fields. These advances, along with the urgency of need to bridge key gaps in knowledge for design and operation of reactors such as ITER, have driven planned expansion of efforts in ML/AI within the US government and around the world. The Department of Energy (DOE) Office of Science programs in Fusion Energy Sciences (FES) and Advanced Scientific Computing Research (ASCR) have organized several activities to identify best strategies and approaches for applying ML/AI methods to fusion energy research. This paper describes the results of a joint FES/ASCR DOE-sponsored Research Needs Workshop on Advancing Fusion with Machine Learning, held April 30–May 2, 2019, in Gaithersburg, MD (full report available at https://science.osti.gov/-/media/fes/pdf/workshop-reports/FES_ASCR_Machine_Learning_Report.pdf ). The workshop drew on broad representation from both FES and ASCR scientific communities, and identified seven Priority Research Opportunities (PRO’s) with high potential for advancing fusion energy. In addition to the PRO topics themselves, the workshop identified research guidelines to maximize the effectiveness of ML/AI methods in fusion energy science, which include focusing on uncertainty quantification, methods for quantifying regions of validity of models and algorithms, and applying highly integrated teams of ML/AI mathematicians, computer scientists, and fusion energy scientists with domain expertise in the relevant areas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GLBRC Soil Yearlong Incubation 13C-SIP-Lipidomics

Data package for Lipids represent a dynamic, yet stable pool of microbially-derived soil carbon This data is published under a CC0 license. The authors encourage data reuse and request attribution by referencing the below citations for the data packages and associated manuscript. Please cite as: Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. GLBRC Soil Yearlong Incubation 13C-SIP-Lipidomics. [Data Set] PNNL DataHub. doi: Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. MSV000097435: GLBRC soil yearlong incubation 13C-SIP-Lipidomics [Data Set] MassIVE. doi:10.25345/C57659T3K Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. Lipids represent a dynamic, yet stable pool of microbially-derived soil carbon. In Prep This data package consists of compound-specific 13C SIP-lipidomics data from a yearlong tracer incubation experiment designed to investigate microbial lipid persistence in switchgrass bioenergy crop soils. In order to explore how lipid structure may modulate the persistence of C in soil lipids, we leveraged soils from two sites (Michigan - sandy texture, Wisconsin - silty texture) operated by the U.S. Department of Energy-funded Great Lakes Bioenergy Research Center (GLBRC). These sites had comparable climates, identical management practices, but contrasting soil textures, allowing us to assess the variability of lipid accrual or degradation in soils as well as provide insight regarding the degree to which edaphic properties may regulate the retention of soil lipids. Untargeted lipidomics analyses were performed to identify 13C-labeled lipids in the soil microbiome after long-term incubation. Soils were supplemented with 100 micrograms glucose per gram dry soil (99 atom % 13C or natural abundance for paired control) and incubated; samples were collected two months and one year after glucose addition. Lipid extracts (MPLEx) were analyzed by LC-MS/MS and identified using LIQUID. Calculation of isotopic enrichment of lipids was performed by targeted approach using TarMet to quantify lipid isotopologues and IsoCorrectoR to correct for natural abundance isotopes. Contents: Data package contents reported here are the first version and contain downstream analysis files for the raw LC-MS mass spectrometry files (.mzXML) deposited at the MassIVE database repository under accession MSV000097435 (80 experimental runs; 5.85 GB) | MassIVE DOI: 10.25345/C57659T3K. Support files include the additional data download 'Read Me' file containing data descriptor information. Reported data download contents are structured for compliance with project data sharing guidelines, community standards initiatives, and sponsor stakeholder policies supporting FAIR data principles. Data processing software, analysis tools, and data workflows are listed below corresponding to the host repository long-term location. Available Data Downloads (0.3 GB): "GLBRC soil yearlong incubation 13C-SIP-Lipidomics_readme.txt" - 'Read Me' data package content file (txt) "GLBRC_DataPackage_analysis files" - Data processing files (Rmd) and saved intermediate data processing outputs (rds, csv, xlsx) "GLBRC_13C_lipidomics_dataset.xlsx" - processed data in tabular format (xlsx) Linked Software: LIQUID LC-MS Analysis Software | 10.5281/zenodo.6459462 Lipid Mini-On Software Tools | 10.5281/zenodo.1492803 pmartR Omics Statistical Software | 10.5281/zenodo.6108667 xcms (v4.3.3) TarMet (v1.1.1) IsoCorrectoR (1.24.0) Funding Acknowledgments: This research was supported by an Early Career Research Program award funded by the U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research (OBER) Genomic Science program under FWP 68292, FWP 07880 and EMSL Exploratory Research Project 51095. A portion of this work was performed in the William R. Wiley Environmental Molecular Sciences Laboratory, a national scientific user facility sponsored by OBER and located at Pacific Northwest National Laboratory (PNNL). PNNL is a multi-program national laboratory operated by Battelle for the DOE under Contract DE-AC05-76RLO1830.

Rempfert, Kaitlin R [Pacific Northwest National La↗

MO-A-BRC-02: TG167 Report - Detailed Description

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.

60 APPLIED LIFE SCIENCES↗

MO-A-BRC-00: TG167: Clinical Recommendations for Innovative Brachytherapy Devices and Applicators

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.

60 APPLIED LIFE SCIENCES↗

MO-A-BRC-01: TG167 Report - Introduction

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.

60 APPLIED LIFE SCIENCES↗

The Effect of Kr-85 Decay to Rb-85 on Waste Forms - 17105

Krypton-85 (Kr-85) is a volatile radionuclide released during the reprocessing of used nuclear fuel (UNF). Prior to discharge of process off-gas streams to the environment, removal of Kr-85 is required to meet emission regulations. Once removed from the off-gas streams, Kr (containing stable Kr in addition to Kr-85) must be placed in storage until the Kr-85 has decayed to levels such that its potential release would meet regulatory guidelines. The current method of storage is high-pressure metal canisters. Historically, concerns have been expressed that the decay product of Kr-85, Rubidium-85 (Rb-85), could cause corrosion and weakening in the canisters that would ultimately lead to premature failure and release of Kr-85. Alternate methods and materials, such as matrix isolation in a vapor deposited metal and immobilization in zeolites, have been investigated as storage approaches for Kr. However, even these storage methods may become compromised due to the chemical effects of Rb-85 arising from the decay of Kr-85. A review was conducted of the available literature to examine topics relevant to the effects of Rb on the long-term storage of Kr-85, examine the source terms in the context of this concern, and suggest a path forward to resolve outstanding knowledge gaps. In the course of this analysis, several knowledge gaps were identified. Examples include: o The use of solid sorbents to potentially permit more Kr-85-bearing gas to be loaded into canisters, either at the pressures used in the current method or at significantly lower pressures. o A cost-to-benefit analysis is needed to ascertain the practicality of manufacturing waste forms for Kr-85 storage with solid sorbents. o The effects of radiation and chemical transmutation in solid sorbents or matrices for this application are virtually unknown. o Fundamental data are needed on corrosion rates and mechanisms as functions of Rb concentration, storage temperature, etc., for various storage approaches (e.g., as compressed gas or encapsulated in a getter material) and storage container materials. The present analysis focused on the available information regarding storage of Kr-85 in high-pressure containers. It was judged unlikely that such containers would be compromised by corrosion from the Rb decay product, especially if the Kr recovery operations result in a gas composition with very low oxygen content. However, this conclusion should be revisited based on preliminary data gathered from analysis of legacy Kr waste forms. These legacy waste forms are a result of experiments conducted at Idaho National Laboratory over 30 y ago and have been stored for more than three Kr-85 half-lives. Evaluation of these forms indicates significant corrosion, the cause of which has not been conclusively determined. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Single-Shell Tank and Double-Shell Tank Integrity Programs - 16390

Waste at Hanford is stored in 149 single-shell tanks and 28 double-shell tanks. Concerns related to aging radioactive waste storage facilities throughout the DOE complex led to Brookhaven National Laboratory (BNL) developing guidelines for structural integrity programs for tank systems. The committee of experts who developed these guidelines is commonly known as the Tank Structural Integrity Panel (TSIP). The DOE has subsequently adopted these guidelines, and requires site operators to have a program consistent with them. The Double-Shell Tank (DST) integrity is maintained with a variety of activities such as ultrasonic and visual inspections, chemistry controls, corrosion monitoring and structural analyses methods. In October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of 241-AY-102 was leaking. WRPS contracted a panel of experts from industry and academia to provide advice and recommendations for the DST Integrity Program. The panel focused on three concerns: - No Early warning - Determine why the existing DST Integrity Program did not predict a primary tank failure or provide early warning of the pending failure. - Program improvements - Recommend activities to either predict a primary tank failure or increase the probability of early warning. - Forensic recommendations - The panel provided additional recommendations regarding forensic assessment of Tank 241-AY-102 (AY-102) to facilitate a conclusion on why the leak occurred. WRPS has prepared a response to the concerns of the panel coupled with recommendations for project action to strengthen the DST Integrity Program [4]. The purpose of this DST Integrity Improvement Plan is to translate the recommendations to specific project activities that are technically and practically responsive. To improve the understanding of the Single-Shell Tank (SST) integrity, WRPS, the Department of Energy-Office of River Protection tank operations contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009. An expert panel on SST integrity, consisting of various subject matter experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration. In late 2010, seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, also known as the Tri-Party Agreement. The change package identified two phases of work for SST integrity. The initial phase, which was completed in 2015, was focused on efforts to envelope the integrity of the tanks. It was divided into two primary areas of investigation: structural integrity and leak integrity. If necessary, based on the outcome from the initial work, a second phase would be focused on further definition of the integrity of the tanks and liners. The two combined phases are designed to support the formal integrity assessment of the Hanford SSTs in 2018 by an Independent Qualified Registered Professional Engineer. This paper will summarize the current status of the DST and SST Integrity Programs and discuss the ongoing efforts to improve these programs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗