Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

EMP-Resilient Electric Grid Transformer Analysis

The response of a high - voltage (HV) transformer to fast rise time voltages, such as that from a electromagnetic pulse (EMP) can result in interruption of power distribution and possibly system failure. To help identify these potential occurrences, it is necessary to develop a transformer model that not only captures the input/output response of the transformer but also the internal behavior. The model constructed should cover the frequency band of interest while capturing the internal physical and electrical characteristics. This broad-band, high-fidelity model would enable the prediction of unwanted effects through simulation. A proposed modeling scheme for a HV transformer is described in Part 1 of this report. Part 2 of this report details assessments of internal voltage and electrical field holdoff testing of transformer insulation dielectric breakdown, including comparison of low frequency (DC/60 Hz) holdoff to rise times characteristic of lightning (1 s) and EMP E1 transients (10 - 30 ns). This initial project is a path toward establishing electrical grid transformer failure criteria for EMP voltage transients. We developed modeling methods and measured breakdown electrical field statistical distributions for direct current, 60 Hz, lightning and EMP characteristic voltage rise times. Methods of nanosecond-scale capacitive discharge unit high voltage source development, suggestions for derating of 60 Hz insulation maximum electrical fields for EMP nanosecond pulse voltage withstand rating, and potential methods for increasing transformer resilience to such fast rise time pulses are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Framework to Design Consumer-Centric Operational Strategies for Resilience Enhancement

Extreme temperature-related events like heat waves or cold snaps can significantly stress the power distribution grid as electricity demand spikes leading to brownouts or blackouts if not managed properly. In addition, such extreme events can exacerbate inequity, with vulnerable populations (for example, houses with poor insulation, located in non-critical zones, and lack of local resources) at greater risk. There is a growing deployment of distribution systems automation technologies such as advanced metering infrastructure, sensors, and automated control systems to enhance the visibility of the entire distribution grid while meeting resilience objectives. Here, this paper proposes a framework for investigating how automation can improve the distribution system's resilience and ensure customers' health and safety during such extremes. The proposed framework's efficacy will be demonstrated for the Electricity Reliability Council of Texas (ERCOT) during winter storm Uri with varying levels of distribution automation technologies such as feeder isolation using smart switches, remote outage signals using advanced meters, and comfort-aware outage using advanced analytics and communication. Simulation results show that an outage strategy involving advanced grid technology and communication can reduce the occupant exposure to severe cold by 93% and, simultaneously, reduce expected energy not served by 73.2% when compared against feeder isolation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Neutronics Design and Analysis of the Fast Modular Reactor

General Atomics is developing a new 100-MW(thermal) fast modular reactor (FMR) that provides safe, carbon-free electricity and is capable of incremental capacity additions. The modular design allows it to be factory built and assembled onsite to keep the capital cost low, while the use of dry cooling facilitates siting to complement renewables in nearly any location. The FMR uses high-assay low-enriched uranium-dioxide fuel encapsulated by recognized irradiationresistant silicon carbide composite (SiGA®) cladding that is derisked in the current accident-tolerant fuel program. The FMR fuel assembly is a hexagonal fuel bundle of 120 fuel rods. The total length of the fuel assembly is less than 4 m, with an active fuel length of 1.8 m. The fuel assemblies are configured in an annular core that is located and supported by the reactor internals. The coolant material is helium at a normal operating pressure of 7 MPa. The core is surrounded by zirconium silicide (Zr 3 Si 2 ) and graphite reflector blocks. The fuel, coolant, internals, and reflectors are contained within a reactor pressure vessel. Here, the preliminary nuclear design and analysis established the arrangement of the active core and reflector blocks. The nuclear design analyses of the FMR defined the design parameters, such as fuel enrichments, excess reactivity, fueling scheme, fuel cycle, power distribution, and control rod worth. The preliminary conceptual design determined the three-batch fueling scheme with the allowable total power peaking factor of 1.5. The average discharge burnup is 100 GW days per ton of uranium.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing of the Engineering Model Electrical Power Control Unit for the Fluids and Combustion Facility

The John H. Glenn Research Center at Lewis Field (GRC) in Cleveland, OH and the Sundstrand Corporation in Rockford, IL have designed and developed an Engineering Model (EM) Electrical Power Control Unit (EPCU) for the Fluids Combustion Facility, (FCF) experiments to be flown on the International Space Station (ISS). The EPCU will be used as the power interface to the ISS power distribution system for the FCF's space experiments'test and telemetry hardware. Furthermore. it is proposed to be the common power interface for all experiments. The EPCU is a three kilowatt 12OVdc-to-28Vdc converter utilizing three independent Power Converter Units (PCUs), each rated at 1kWe (36Adc @ 28Vdc) which are paralleled and synchronized. Each converter may be fed from one of two ISS power channels. The 28Vdc loads are connected to the EPCU output via 48 solid-state and current-limiting switches, rated at 4Adc each. These switches may be paralleled to supply any given load up to the 108Adc normal operational limit of the paralleled converters. The EPCU was designed in this manner to maximize allocated-power utilization. to shed loads autonomously, to provide fault tolerance. and to provide a flexible power converter and control module to meet various ISS load demands. Tests of the EPCU in the Power Systems Facility testbed at GRC reveal that the overall converted-power efficiency, is approximately 89% with a nominal-input voltage of 12OVdc and a total load in the range of 4O% to 110% rated 28Vdc load. (The PCUs alone have an efficiency of approximately 94.5%). Furthermore, the EM unit passed all flight-qualification level (and beyond) vibration tests, passed ISS EMI (conducted, radiated. and susceptibility) requirements. successfully operated for extended periods in a thermal/vacuum chamber, was integrated with a proto-flight experiment and passed all stability and functional requirements.

Kimnach, Greg L.↗

GDM (Grid Data Models) [SWR-24-31]

Grid Data Models (GDM) is a collection of pydantic data models for power distribution and transmission system components. These data models can be easily serialized and deserialized. GDM provides a standard interface for accessing power system component data with built in validation. See also: https://pypi.org/project/grid-data-models/

Duwadi, Kapil↗

Electrical Substation Configuration Effect on Substation Reliability

It is crucial that the U.S. electrical grid be reliable, due to its critical role in the economy and our national defense/security. Many common tasks and industrial operations rely on proper electrical power distribution. In designing new bus systems or evaluating existing ones, the type of configuration employed affects the level of risk, reliability, maintenance, and cost involved. The present work utilizes Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) to perform a probabilistic risk assessment (PRA)-based sensitivity study on substation reliability in regard to different bus configurations. This study examines single bus, main and transfer, breaker and a half, double bus/double breaker, and ring bus configurations applied to busses with different numbers of lines. The case variances, methods, and rankings presented herein can help guide bus configurations for electrical grid design/analysis in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical Substation Configuration Effect on Substation Reliability

The nation’s electrical grid must be reliable because of its critical role in the economy, defense, and security of the nation. Many common tasks and industrial operations rely on proper electrical power distribution. In the design of new bus systems or evaluation of existing bus systems, the type of bus configuration affects the risk, reliability, maintenance, and cost of the system. This work utilizes Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) to perform a probabilistic risk assessment (PRA) based sensitivity study on the reliability of substations with differing bus configurations. This study examines single bus, main and transfer, breaker and a half, double bus/double breaker, and ring bus configurations applied to busses of varying number of lines. The case variances, methods, and rankings presented can provide a guide for bus configuration for future electrical grid design and analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods for detecting and mitigating cyber attacks on power systems comprising distributed energy resources

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cybersecurity attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid-support functions which can drastically influence power quality, voltage, and the generation-load balance. Investigations of the impact to the power system in scenarios where communications and operations of DER are controlled by an adversary show that each grid-support function exposes the power system to distinct types and magnitudes of risk. The invention provides methods for minimizing the risks to distribution and transmission systems using an engineered control system which detects and mitigates unsafe control commands.

97 MATHEMATICS AND COMPUTING↗

Systems and methods for detecting and mitigating cyber attacks on power systems comprising distributed energy resources

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cybersecurity attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid-support functions which can drastically influence power quality, voltage, and the generation-load balance. Investigations of the impact to the power system in scenarios where communications and operations of DER are controlled by an adversary show that each grid-support function exposes the power system to distinct types and magnitudes of risk. The invention provides methods for minimizing the risks to distribution and transmission systems using an engineered control system which detects and mitigates unsafe control commands.

Johnson, Jay Tillay↗

Intelligent Systems for Power Management and Distribution

The motivation behind an advanced technology program to develop intelligent power management and distribution (PMAD) systems is described. The program concentrates on developing digital control and distributed processing algorithms for PMAD components and systems to improve their size, weight, efficiency, and reliability. Specific areas of research in developing intelligent DC-DC converters and distributed switchgear are described. Results from recent development efforts are presented along with expected future benefits to the overall PMAD system performance.

Button, Robert M.↗

Intelligent Systems for Power Management and Distribution

The motivation behind an advanced technology program to develop intelligent power management and distribution (PMAD) systems is described. The program concentrates on developing digital control and distributed processing algorithms for PMAD components and systems to improve their size, weight, efficiency, and reliability. Specific areas of research in developing intelligent DC-DC converters and distributed switchgear are described. Results from recent development efforts are presented along with expected future benefits to the overall PMAD system performance.

Button, Robert M.↗

Grid Topology Discovery Algorithm Evaluation of Suitability for Utility Deployment (CRADA 606 Final Report)

This work presents the results of a field-informed demonstration aimed at evaluating the practical suitability of a topology discovery algorithm for utility environments. We demonstrated an algorithm that uses a graph-theory-informed state estimation approach for model selection. In collaboration with Survalent and Peninsula Light Co., the algorithm was applied to real feeder models and field measurements from supervisory control and data acquisition (SCADA) and advanced metering infrastructure (AMI) systems to identify the operational topology of a power distribution system. The demonstration assessed the algorithm’s performance under realistic data conditions, including sparse and noisy measurements, and examined its ability to identify the most likely network configurations. The results confirmed that the approach can effectively narrow down feasible topologies, providing operators with improved situational awareness of network status. Key lessons learned emphasize the need for systematic data validation and strategic sensor placement to enhance observability. These insights inform future deployment strategies and guide refinements for broader adoption in utility operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Abstract for CRADA between NETL and Electric Power Research Institute (EPRI) (AGMT-1113)

The National Energy Technology Laboratory (NETL) and EPRI (Participant) will collaborate in the investigation of flashovers in electric power distribution maintenance operations. Live line and barehand maintenance techniques are used on overhead transmission lines around the world. While flashovers during this type of work are rare, several unexplained flashovers have occurred in North America. In each case, available evidence suggests these occurred at steady state (60 Hz) system voltage and at voltage stress levels well below that which is known to cause flashover. Understanding the cause of these flashovers is essential so they can be avoided in the future and enhance line worker safety. Some utilities are considering adding sheds to their live line tools (e.g. hot sticks) as a possible mitigation measure. The effect of adding sheds to the hot sticks was modelled and published by Chalmers University. A strong case can be made for sheds if the model can be validated through laboratory testing. This research is envisioned to be a multiple-year project. The work proposed under this agreement represents the initial research steps which will involve reproducing, verifying, and extending the modeling research previously published by Chalmers University.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AC Power Flow Based DLMP Calculation and Decomposition Method to Smooth Power Fluctuation of Distributed Renewable Energy Sources

As the penetration of renewable energy sources increases, the growing renewable power variability brings ramping issues to power systems. Meanwhile, the development of distributed energy resources (DERs) makes the distribution systems to provide both energy and ancillary services. To incentivise individual resources and customers to alleviate ramping issues on the demand side, a two-stage distribution locational marginal price (DLMP) calculation and decomposition method is developed to formulate the marginal power ramping price for DERs. In the first stage of the proposed method, a distribution system operator market scheduling model based on AC optimal power flow is designed to estimate the optimal operating point of the distribution system. Subsequently, the voltage and power flow constraints are linearised in stage two to calculate DLMP. Finally, based on the Lagrange function and sensitivity factors, DLMP is decomposed to the marginal costs for active/reactive power, voltage management, power loss and power variability. Case studies demonstrate that the proposed model can effectively smooth the power fluctuation and reduce the ramping flexibility requirements of distribution systems.

AC optimal power flow↗

Embedded, Real-Time, and Distributed Traveling Wave Fault Location Method Using Graph Convolutional Neural Networks

This work proposes and develops an implementation of a fault location method to provide a fast and resilient protection scheme for power distribution systems. The method analyzes the transient dynamics of traveling waves (TWs) to generate features using the discrete wavelet transform (DWT), which are then used to train several graph convolutional network (GCN) models. Faults are simulated in the IEEE 34-node system, which is divided into three protection zones (PZs). The goal is to identify the PZ in which the fault occurs. The GCN models create a distributed protection scheme, as all nodes are able to retrieve a prediction. Given that message-passing between nodes occurs both during training and in the execution of the model, the resiliency of such schemes to communication losses was analyzed and demonstrated. One of the models, which only uses voltage measurements, was implemented on a Texas Instruments F28379D development board. The execution times were monitored to assess the speed of the protection scheme. It is shown that the proposed method can be executed in approximately a millisecond, which is comparable to existing TW protection in the transmission system. For experimental purposes, a DWT-based detection method is employed. A design of a setup to playback TWs using two development boards is also addressed.

Jiménez-Aparicio, Miguel (ORCID:000000016864461X)↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SPS silicon reference system

The design analysis of a silicon power conversion system for the solar power satellite (SPS) is summarized. The solar array, consisting of glass encapsulated 50 micrometer silicon solar cells, is described. The general scheme for power distribution to the array/antenna interface is described. Degradation by proton irradiation is considered. The interface between the solar array and the klystron equipped power transmitter is described.

Woodcock, G. R.↗

Mir Cooperative Solar Array Flight Performance Data and Computational Analysis

The Mir Cooperative Solar Array (MCSA) was developed jointly by the United States (US) and Russia to provide approximately 6 kW of photovoltaic power to the Russian space station Mir. The MCSA was launched to Mir in November 1995 and installed on the Kvant-1 module in May 1996. Since the MCSA photovoltaic panel modules (PPMs) are nearly identical to those of the International Space Station (ISS) photovoltaic arrays, MCSA operation offered an opportunity to gather multi-year performance data on this technology prior to its implementation on ISS. Two specially designed test sequences were executed in June and December 1996 to measure MCSA performance. Each test period encompassed 3 orbital revolutions whereby the current produced by the MCSA channels was measured. The temperature of MCSA PPMs was also measured. To better interpret the MCSA flight data, a dedicated FORTRAN computer code was developed to predict the detailed thermal-electrical performance of the MCSA. Flight data compared very favorably with computational performance predictions. This indicated that the MCSA electrical performance was fully meeting pre-flight expectations. There were no measurable indications of unexpected or precipitous MCSA performance degradation due to contamination or other causes after 7 months of operation on orbit. Power delivered to the Mir bus was lower than desired as a consequence of the retrofitted power distribution cabling. The strong correlation of experimental and computational results further bolsters the confidence level of performance codes used in critical ISS electric power forecasting. In this paper, MCSA flight performance tests are described as well as the computational modeling behind the performance predictions.

Kerslake, Thomas W.↗