Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Downlink Receiver Algorithms for Deep Space Optical Communications

The goal of the Deep Space Optical Communications project at the Jet Propulsion Laboratory is to demonstrate laser communication links at ranges out to approximately 3 AU. In this paper, we discuss a downlink receiver concept capable of demodulating optical pulse-position modulated (PPM) waveforms with data rates varying from approximately 50 kbps up to 265 Mbps, using a range of PPM orders, slot widths, and code rates. The receiver operates on recorded timestamps corresponding to the times-of-arrival of photons detected by a photon-counting detector array followed by a commercial time-tagger. Algorithms are presented for slot, symbol, and frame synchronization as well as parameter estimation. Estimates of link performance are evaluated through Monte- Carlo simulation for an optical channel that includes optical losses, detector blocking, signal clock dynamics, and pointing-induced downlink fades. Based upon these simulation results, it is expected that link closure may be achieved with at least 3 dB of margin under a variety of relevant conditions.

Tkacenko, Andre↗

Statistical optical link budget analysis

In this paper, we describe work on extending statistical analysis methods to optical communications links, with a primary focus on intensity modulated, direct detected photon-counting channel utilizing pulse-position-modulation (PPM). We performed analysis on the relationship between bit error rate (BER) requirement, statistical characteristics of the received signal power and noise power, and the coded performance curves. We presented link analysis results with preliminary uncertainty quantifications of signal power and noise power. We used the Consultative Committee for Space Data Systems (CCSDS) Serially Concatenated convolutionally coded Pulse Position Modulation (SCPPM) prototype software [1] to obtain coded performance curves under different operating conditions with varying signal power, background noise power, code rates,and PPM modulation orders. Comparison with traditional, deterministic analysis shows that extra margin needs to be reserved to compensate for the performance losses caused by uncertainties of the link parameters.

Cheung, Kar-Ming↗

High-precision x-ray timing of three millisecond pulsars with NICER: Stability estimates and comparison with radio

The Neutron Star Interior Composition Explorer (NICER) is an X-ray astrophysics payload on the International Space Station. It enables unprecedented high-precision timing of millisecond pulsars (MSPs) without the pulse broadening and delays due to dispersion and scattering within the interstellar medium that plague radio timing. We present initial timing results from a year of data on the MSPs PSR B1937+21 and PSR J0218+4232, and nine months of data on PSR B1821−24. NICER time-of-arrival uncertainties for the three pulsars are consistent with theoretical lower bounds and simulations based on their pulse shape templates and average source and background photon count rates. To estimate timing stability, we use the σz measure, which is based on the average of the cubic coefficients of polynomial fits to subsets of timing residuals. So far we are achieving timing stabilities σz≈3×10−14 for PSR B1937+21 and on the order of 10−12 for PSRs B1821−24 and J0218+4232. Within the span of our NICER data we do not yet see the characteristic break point in the slope of σz; detection of such a break would indicate that further improvement in the cumulative root-mean-square timing residual is limited by timing noise. We see this break point in our comparison radio data sets for PSR B1821−24 and PSR B1937+21 on timescales of >2 yr.

Pulsars↗

The Soft State of the Black Hole Transient Source MAXI J1820+070: Emission from the Edge of the Plunge Region?

The Galactic black hole X-ray binary MAXI J1820+070 had a bright outburst in 2018 when it became the second brightest X-ray source in the sky. It was too bright for X-ray CCD instruments such as XMM–Newton and Chandra, but was well observed by photon counting instruments such as Neutron star Inner Composition Explorer (NICER) and Nuclear Spectroscopic Telescope Array (NuSTAR). We report here on the discovery of an excess emission component during the soft state. It is best modelled with a blackbody spectrum in addition to the regular disc emission, modelled as either diskbb or kerrbb. Its temperature varies from about 0.9 to 1.1 keV, which is about 30–80 per cent higher than the inner disc temperature of diskbb. Its flux varies between 4 and 12 per cent of the disc flux. Simulations of magnetized accretion discs have predicted the possibility of excess emission associated with a non-zero torque at the innermost stable circular orbit (ISCO) about the black hole, which, from other NuSTAR studies, lies at about 5 gravitational radii or about 60 km (for a black hole, mass is 8Msun). In this case, the emitting region at the ISCO has a width varying between 1.3 and 4.6 km and would encompass the start of the plunge region where matter begins to fall freely into the black hole.

A C Fabian↗

Optimal filtering of overlapped pulses in microcalorimeter data

In this study, we present a general algorithm for processing microcalorimeter data with special applicability to data with high photon count rates. Conventional optimal filtering, which has become ubiquitous in microcalorimeter data processing, suffers from its inability to recover overlapped pulses without sacrificing spectral resolution. The technique presented here was developed to address this particular shortcoming and does so without imposing any assumptions beyond those made by the conventional technique. We demonstrate the performance of the algorithm with a dataset that approximately satisfies these assumptions and which is representative of a wide range of microcalorimeter applications. We also apply the technique to a highly non-linear dataset, examining the impact on performance in the limit that these assumptions break down.

Dallas Wulf↗

Radiometric Calibration of A Non-Imaging Airborne Spectrometer To Measure the Greenland Ice Sheet Surface

Methods to radiometrically calibrate a non-imaging airborne visible-to-shortwave infrared (VSWIR) spectrometer to measure the Greenland ice sheet surface are presented. Airborne VSWIR measurement performance for bright Greenland ice and dark bare rock/soil targets is compared against the MODerate resolution atmospheric TRANsmission (MODTRAN ® ) radiative transfer code (version 6.0), and a coincident Landsat 8 Operational Land Imager (OLI) acquisition on 29 July 2015 during an in-flight radiometric calibration experiment. Airborne remote sensing flights were carried out in northwestern Greenland in preparation for the Ice, Cloud, and land Elevation Satellite 2 (ICESat-2) laser altimeter mission. A total of nine science flights were conducted over the Greenland ice sheet, sea ice, and open-ocean water. The campaign's primary purpose was to correlate green laser pulse penetration into snow and ice with spectroscopic-derived surface properties. An experimental airborne instrument configuration that included a nadir-viewing (looking downward at the surface) non-imaging Analytical Spectral Devices (ASD) Inc. spectrometer that measured upwelling VSWIR (0.35 to 2.5 µm) spectral radiance (Wm −2 sr −1 µm −1 ) in the two-color Slope Imaging Multi-polarization Photon-Counting Lidar's (SIMPL) ground instantaneous field of view, and a zenith-viewing (looking upward at the sky) ASD spectrometer that measured VSWIR spectral irradiance (W m −2 nm −1 ) was flown. National Institute of Standards and Technology (NIST) traceable radiometric calibration procedures for laboratory, in-flight, and field environments are described in detail to achieve a targeted VSWIR measurement requirement of within 5 % to support calibration/validation efforts and remote sensing algorithm development. Our MODTRAN predictions for the 29 July flight line over dark and bright targets indicate that the airborne nadir-viewing spectrometer spectral radiance measurement uncertainty was between 0.6 % and 4.7 % for VSWIR wavelengths (0.4 to 2.0 µm) with atmospheric transmittance greater than 80 %. MODTRAN predictions for Landsat 8 OLI relative spectral response functions suggest that OLI is measuring 6 % to 16 % more top-of-atmosphere (TOA) spectral radiance from the Greenland ice sheet surface than was predicted using apparent reflectance spectra from the nadir-viewing spectrometer. While more investigation is required to convert airborne VSWIR spectral radiance into atmospherically corrected airborne surface reflectance, it is expected that airborne science flight data products will contribute to spectroscopic determination of Greenland ice sheet surface optical properties to improve understanding of their potential influence on ICESat-2 measurements.

Christopher J. Crawford↗

Sea Surface Height Anomalies of the Arctic Ocean from Icesat-2: A First Examination and Comparisons with Cryosat-2

Accurately resolving spatio-temporal variations in sea surface height across the polar oceans is key to improving our understanding of ocean circulation variability and change. Here, we examine the first two years (2018-2020) of Arctic Ocean sea surface height anomalies (SSHA) from the photon-counting laser altimeter onboard NASA’s ICE, Cloud, and Land Elevation Satellite-2 (ICESat-2). ICESat-2 SSHA estimates are compared to estimates from ESA’s CryoSat-2 mission, including semi-synchronous along-track measurements from the recent CRYO2ICE orbit alignment campaign. There are documented residual centimeter-scale range biases between the ICESat-2 beams (in release-003 data) and we opted for a single-beam approach in our comparisons. We find good agreement in the along-track estimates (spatial correlation coefficient >0.8 and mean differences <0.03 m) as well as in the gridded monthly SSHA estimates (temporal correlation coefficient of 0.76 and a mean difference of 0.01 m) from the two altimeters, suggesting ICESat-2 adds to the CryoSat-2 SSHA estimates.

ICESat-2↗

ICESat-2 Atmospheric Channel Description, Data Processing and First Results

The Advanced Topographic Laser Altimeter System (ATLAS) was launched aboard the Ice Cloud and land-Elevation Satellite-2 (ICESat-2) satellite in September 2018. ATLAS is a single wavelength (532 nm) lidar system designed to acquire high resolution measurements of the earth's surface while also obtaining atmospheric backscatter from molecules, clouds, and aerosols. Because ATLAS is optimized for altimetry, the atmospheric data acquired is unique in many respects and requires non-standard analysis techniques. For example, the high repetition rate laser limits the vertical extent of the profiles to just 14 km and causes atmospheric scattering from above 15 km to be added to the scattering in the lower 0–14 km profile. In addition, the limited vertical range of the acquired profiles renders it difficult to compute the magnitude of the solar background and hinders the application of standard calibration techniques. Despite these limitations, methods have been developed to successfully produce data products that have value to the atmospheric community for cloud and aerosol research and are currently available at the National Snow and Ice Data Center (NSIDC). In this paper we describe the ICESat-2 atmospheric channel and the methods used to process the ATLAS raw photon count data to obtain calibrated backscatter and higher level products such as layer heights and type, blowing snow, column optical depth and apparent surface reflectance.

Stephen P Palm↗

Investigation Of Prandtl-Ishlinskii Hysteresis Compensation for Deep Space Optical Communications Pointing Control

This paper studies the simulated performance of the Deep Space Optical Communication (DSOC) laser downlink pointing control system that has a pointing requirement at the sub-microradian scale. To achieve the required pointing precision, the DSOC Flight Laser Transceiver (FLT) point-ahead mirror (PAM) employs piezoelectric actuators, which are widely used in precision applications due to their high motion resolution, rapid response, and high output forces. However, a piezoelectric actuator's performance is often limited by nonlinearities in their response, most significantly hysteresis. To study the effect of hysteresis on our simulated pointing performance, an invertible hysteresis model is developed using the Classical Prantdl-Ishlinskii (CPI) method. The simulation includes models of DSOC hardware and electronic system components based on key parameters (bias, frequency response, noise), with the hysteresis modeled in the PAM piezo actuator dynamics. A Proportional-Integral controller provides feedback with measurements from two potential sources: strain gauge sensors or a photon-counting camera. To compensate for hysteresis behavior, a feedforward inverse CPI hysteresis model is implemented in the control system. Two CPI models are built using different sampling methods (uniform sampling and cosine spacing) and controller performance is compared. For the maximum command range of ±400 μrad at 1 mHz, results show that the feedforward combined with feedback control reduces output tracking error by 50% or 58% (to 0.20 or 0.38 μrad) compared to feedback control alone (from 0.40 or 0.90 μrad), corresponding to the uniform-sampled and cosine-sampled CPI models, respectively.

Marinello, Lindsey A.↗

The Roman Space Telescope Coronagraph Technology Demonstration: Current Status and Relevance to Future Missions

The Nancy Grace Roman Space Telescope (formally WFIRST) will be launched in the mid-2020’s with an onboard coronagraph instrument which will serve as a technology demonstrator for exoplanet direct imaging. The Roman Coronagraph will be capable of detecting and characterizing exoplanets and circumstellar disks in visible light at an unprecedented contrast level of ~10-8 or lower. Such a contrast level, which is several magnitudes better than state-of-the-art visible or near-infrared coronagraphs, raises entirely new challenges that will be overcome using a combination of hardware, calibration and data processing. In particular, the Roman Coronagraph will be the first space-based coronagraphic instrument with real-time active wavefront control through the use of large format deformable mirrors, and its EMCCD detector will enable faint signal detection in photon-counting mode. The Roman Coronagraph passed its critical design review successfully in April 2021, and is now well on its path to demonstrate many core technologies at the levels required for future exo-Earth direct imaging missions.

Luchik, T.↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consists of eighty-channel detector plane histograms that accumulate photon counts over time periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey dataset between 14 and 195 keV. Survey data comprises >90% of all BAT data by volume and allows for the tracking of long term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey dataset has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis python package , a wrapper for HEASoftpy, which provides a modern, open-source pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the python code and exemplify its usefulness and accuracy by analyzing survey data from the Crab Pulsar, NGC 2992, and a previously uncataloged MAXI Transient. The BatAnalysis package allows for ∼ 18 years of BAT survey to be used in a systematic way to study a large variety of astrophysical sources.

Tyler Parsotan↗

ICESat-2/ATLAS at 4 Years: Instrument Performance and Projected Life

NASA’s ICESat-2 mission launched in September 2018 carrying a single instrument, the Advanced Topographic Laser Altimeter System (ATLAS). ATLAS uses a high-repetition-rate, low-pulse-energy laser with its output split into six beams and a photon-counting receiver to measure Earth surface elevation with centimeter-level precision, repeating its ground track every 91 days. During more than four years of on-orbit operation, ATLAS has met or exceeded its lifetime and performance requirements. We present performance measurements, trends and projections for several instrument parameter, including transmitted laser pulse energy, receiver sensitivity, the instrument’s impulse response, transmitter/receiver alignment, dead-time behavior, and elevation measurement performance. The laser energy setting was increased in September 2023, for the first time, to maintain ranging performance at its early mission level. The trends in instrument parameters indicate capability to continue on-orbit operation of ATLAS for many years into the future.

Anthony J. Martino↗

Remote Sensing-Driven Hydrodynamic Modeling in Data-Scarce Regions: Integrating ICESat-2, Sentinel-2, SWOT and Re-analysis Models for Coastal Monitoring

Hydrodynamic models in coastal and estuarine systems are typically constrained by sparse bathymetry, boundary, and validation data, especially in regions where field campaigns are costly or impractical. Here we develop and test a fully satellite-driven framework for hydrodynamic modeling in South Africa’s Langebaan Lagoon without using any local in situ measurements. Bathymetry is derived by training multispectral Sentinel-2 reflectance against ICESat-2 ATL24 photon-derived depths using an XGBoost model optimized with Bayesian search. The final satellite-derived bathymetry reproduces independent ATL24 points with RMSE = 0.45 m and R 2 = 0.97. This bathymetry was used in a depth-averaged Delft3D Flexible Mesh model driven at the open boundary by TPXO tidal harmonics and by ERA5 winds. We validate modeled water surface elevation against 16 SWOT low-rate (250 m, unsmoothed) passes in 2023. SWOT–model comparisons yield an overall RMSE of 0.11 m and R 2 = 0.61, with typical point differences <0.10 m (∼7% of the 1.5 m tidal range), and showed consistent spatial gradients in water level from the offshore boundary, through Saldanha Bay, and into the lagoon. At the offshore boundary, TPXO and SWOT sea surface heights agree closely (R 2 = 0.86). A simple phase adjustment of ∼26,min between TPXO and SWOT lowers the RMSE from 0.18,m to 0.11,m, showing that phase offset accounts for some of the discrepancy, with additional errors likely linked to non-tidal signals. Our results demonstrate that combining passive optical, photon-counting LiDAR, radar interferometry, and global tidal/atmospheric models enables robust, transferrable hydrodynamic modeling in data-scarce coastal systems, offering a cost-effective pathway for monitoring.

ICESat-2↗

Automatic method of material identification for computed tomography

A method is provided for isolating and labeling discrete features in a spectral radiographic image recorded as a set of images in different energy channels. The disclosed method involves creating a profile for each of at least some pixels in the spectral radiographic image. The profiles are sequences of pixel values, in which each pixel value is a photon count or a similar radiographic exposure value indicative of the attenuation of a portion of the scanning beam in a respective energy channel. Iterative hierarchical clustering is used to cluster the pixels on the basis of their respective profiles. Labels are assigned to one or more of the resulting clusters. In implementations, each label can be associated with an inferred material composition or with an inference that the material composition is unknown.

Jimenez, Jr., Edward Steven↗

The Role of Quantum Science Concepts in Enhancing Sensing and Imaging Technologies: Applications for Biology: Proceedings of a Workshop

Quantum concepts hold the potential to enable significant advances in sensing and imaging technologies that could be vital to the study of biological systems. The workshop Quantum Science Concepts in Enhancing Sensing and Imaging Technologies: Applications for Biology, held online March 8–10, 2021, was organized to examine the research and development needs to advance biological applications of quantum technology. Hosted by the National Academies of Sciences, Engineering, and Medicine, the event brought together experts working on state-of-the-art, quantum-enabled technologies and scientists who are interested in applying these technologies to biological systems. Through talks, panels, and discussions, the workshop facilitated a better understanding of the current and future biological applications of quantum-enabled technologies in fields such as microbiology, molecular biology, cell biology, plant science, mycology, and many others. The workshop was organized around three main themes. The first, quantum in biology, examined quantum concepts that are hypothesized to be important for life processes and that researchers are working to observe through biological imaging and sensing. The second, quantum for biology, addressed ways to use quantum concepts to enhance technologies for biological imaging and sensing. The third, biology for quantum, offered a wider discussion of how the frontiers of biological imaging and sensing could enable future study using quantum concepts, tools, or technologies. Throughout the workshop, participants identified a wide range of emerging approaches and opportunities at the intersection of quantum physics and biological sensing and imaging. During the workshop, there were some differences in how each speaker defined the term quantum. During one of the panels, Prem Kumar offered thoughts on what phenomena are classical versus quantum, explaining that techniques get progressively more quantum as you move from just having superposition to having superposition with measurement and entanglement. Another explanation from Clarice Aiello delineates the definition into several levels. This includes a base level of “quantum-ness,” which reflects that all matter is made of atoms, and when these particles are isolated they behave based on quantum mechanical principles. A second level is related to quantum coherence, where a single quantum object might be found in a coherent superposition state. A final level, which she described as the quantum-entangled level, involves multiple quantum systems which are entangled among themselves. Overall, the workshop touched on concepts such as superposition, entanglement, and squeezing and their potential implications for communication, computing, and simulation, in addition to the workshop’s main focal area, biological sensing and imaging. At the opening of the workshop, Thorsten Ritz of the University of California, Irvine, identified two questions at the heart of quantum biology: Is the machinery of life quantum mechanical, and can quantum mechanics be used to study the machinery of life in new ways? Participants highlighted systems in which researchers have explored these questions, from the vast array of molecular interactions involved in biological processes such as photosynthesis, to the mechanics involved in cellular functions such as differentiation and aggregation, to the role of oscillating magnetic fields in flight orientation among birds. Sensing and imaging technologies are crucial to biological research; these technologies could both enhance the study of quantum effects and be enhanced by quantum concepts. A critical challenge in biological research is to develop imaging and sensing tools that do not damage or interfere with the often fragile and fleeting systems being studied. Attendees discussed a variety of established and emerging technologies that could enhance noninvasive biological imaging, including single- and two-photon spectroscopy, single-molecule spectroscopy, quantum illumination, ghost imaging, and cryo-electron microscopy. One example came from Marlan Scully who gave a keynote address on the first day of the workshop. Scully emphasized the use of different laser technologies, which exhibit coherence and other quantum properties, in moving toward real-world biological applications, such as the detection of SARS-CoV-2. Both tools and theory will play an important role in advancing quantum biology research and applications. Several participants suggested theorists and experimentalists should work in tandem to understand and model biological processes. While physics often reduces systems to their simplest forms for fundamental insights, participants also noted the value of observing and understanding biological systems in all their “messiness,” capturing both the inner workings of biological systems and the complex interactions that occur within and between organisms. In discussions among participants, several attendees stressed the need to match emerging tools with the right scientific questions. Rather than developing quantum technologies as “a hammer looking for a nail,” participants emphasized a focus on exploring the problems these technologies are best suited to address. For example, it is important to consider the size of the phenomenon being studied, the timescales that are important in answering the scientific question, and other relevant considerations. Every tool along the spectrum from classical to quantum involves its own set of trade-offs. For example, Ted Laurence of the Lawrence Livermore National Laboratory said that quantum measurements, such as single photon counting, fluorescence transitions, and lasers, can take longer to produce the same results as classical measurements. These quantum measurements, however, do not require calibration and can enable new research questions to be answered. Prem Kumar, Northwestern University, noted that, despite their promise, quantum approaches should not be used simply for the sake of using quantum, especially in situations where classical approaches better meet the needs of the researcher. Understanding and applying quantum concepts could enable advances in a wide range of application areas including energy, synthetic biology, medicine, and sustainability. For example, Michelle O’Malley, University of California, Santa Barbara, described how improved noninvasive imaging approaches could help capture the complex interactions and functions involved in the breakdown of organic matter by microbial communities and lead to new technologies for capturing valuable products from plant waste. Several other participants discussed needs in tracking the movement of metabolites and molecules in microbial communities for insights into nutrient cycling in environments such as soil. Margaret Ahmad, Sorbonne University, discussed potential opportunities to leverage the magnetic properties of cryptochromes to advance new treatment approaches for diseases such as COVID-19 and cancer. Looking toward the future development of the field, participants discussed challenges to advancing quantum biology that arise from disciplinary disconnects between physicists and biologists. The siloing of academic research disciplines represents a significant barrier to progress. Disconnects in terminology, motivations and priorities, and structural barriers to collaborative work underscore the need for concerted efforts to bridge these divides. Attendees and speakers offered suggestions for resolving these divergences, establishing a shared language, moving the field forward, and fostering meaningful feedback between disciplines. Overall, participants stressed a need for balance, open communication, collaboration, unity, and clear dialogue on trade-offs between quantum and classical approaches. Keiko Torii, The University of Texas at Austin, said that the best collaborations happen when the project provides mutual advantages that can show off everyone’s talents, each team finds the work interesting, and partners develop a camaraderie to pursue new knowledge. To enable near- and long-term opportunities in this space, participants suggested that exploratory, high-risk funding could improve existing instrumentation to explore quantum enhancement collaboratively. They also emphasized the need for collaboration between quantum physicists and sensing/imaging scientists, which could be advanced through a dedicated quantum biology investigator program. People, even more than technology, will be crucial to the future of quantum biology. Participants explored training, education, and workforce needs to further develop this burgeoning field and cultivate the next generation of scientists. While many programs are still in their nascent stages, participants highlighted examples of approaches and programs being developed at various types of institutions to engage students and professional scientists in quantum biology research. Several participants stressed the need for an inclusive approach, spanning disciplines as well as communities to foster a diverse field fueled by the intellectual contributions of a wide range of people, including historically under-resourced schools and students. To increase awareness and excitement about quantum physics and related areas of biology, attendees suggested capitalizing on the “buzz” around quantum. Several participants emphasized the need to start early, introducing students to quantum concepts and their appealing “weirdness” in K–12 education. Engaging students early—before they become entrenched in traditional disciplinary siloes as typically happens in graduate school—could help to galvanize interest in the area and foster a generation of scientists with the interdisciplinary mindset and skills needed to advance this interdisciplinary field. While these efforts could be advanced at many levels and across multiple sectors, several participants suggested a national quantum biology center could be a valuable hub to coordinate and support quantum biology education and workforce development across academia, industry, and government.

59 BASIC BIOLOGICAL SCIENCES↗

Digital encoding algorithm for pixelated detectors

A detector for imaging and efficiently digitizing a spatial distribution of photon flux includes pixel circuits that compressively encode pixel values generated by integrated analog to digital converters (ADCs). On-pixel digital compression circuits (DCCs) implement compression to increase continuous frame rate by reducing the number of bits per pixel while keeping quantization error below Poisson noise. Several mapping algorithms for photon-counting and charge-integrating detectors and compact digital logic implementations are presented.

Hammer, Michael P.↗

On the Speed-up of Wave-like Dark Matter Searches with Entangled Qubits

Qubit-based sensing platforms offer promising new directions for wave-like dark matter searches. Recent proposals demonstrate that entangled qubits can achieve quadratic scaling of the signal in the number of qubits. In this work we expand on these proposals to analyze the bandwidth and scan rate performance of entangled qubit protocols across different error regimes. We find that the phase-based readout of entangled protocols preserves the search bandwidth independent of qubit number, in contrast to power-based detection schemes, thereby achieving a genuine scan-rate advantage. We derive coherence time and error rate requirements for qubit systems to realize this advantage. Applying our analysis to dark photon searches, we find that entangled states of approximately 100 qubits can become competitive with benchmark photon-counting cavity experiments for masses $\gtrsim 30{-}40~μ{\rm eV}$, provided sufficiently low error rates are achieved. The advantage increases at higher masses where cavity volume scaling becomes less favorable.

Bodas, Arushi [Fermilab; Chicago U.] (ORCID:000000↗

Axion dark matter search with a photonic bandgap cavity haloscope and dielectric tuning rod over 10.25-10.45 GHz

We report the development of a new widely tunable cavity and demonstrate its use in a search for dark matter axions. We achieve unloaded quality factors above $10^{5}$, roughly $25\times$ larger than a bare copper cavity at the same frequency, using concentric sapphire shells to reduce Ohmic losses on the cavity barrel. A rotating sapphire rod tunes our cavity mode over the $10.1-11.7$ GHz range, approximately $16\%$ of its resonant frequency. Using an amplified receiver chain, we demonstrate sensitivity to new axion parameter space by tuning the cavity over the $200$ MHz range between $10.25-10.45$ GHz (42.4 - 43.2, $μ$eV) to constrain the axion-to-photon coupling to $|g_{aγγ}|$$\leq$ 1 $\times$$10^{-12}$${GeV}^{-1}$. This cavity can scan its tuning range about $9$ times faster compared to a bare copper cavity when paired with a photon counting device, laying the groundwork for a definitive search for the QCD axion over $10.1-11.7$ GHz.

Lynn, Morgan [Chicago U.]↗