Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Acoustic modal analysis of a full-scale annular combustor

An acoustic modal decomposition of the measured pressure field in a full scale annular combustor installed in a ducted test rig is described. The modal analysis, utilizing a least squares optimization routine, is facilitated by the assumption of randomly occurring pressure disturbances which generate equal amplitude clockwise and counter-clockwise pressure waves, and the assumption of statistical independence between modes. These assumptions are fully justified by the measured cross spectral phases between the various measurement points. The resultant modal decomposition indicates that higher order modes compose the dominant portion of the combustor pressure spectrum in the range of frequencies of interest in core noise studies. A second major finding is that, over the frequency range of interest, each individual mode which is present exists in virtual isolation over significant portions of the spectrum. Finally, a comparison between the present results and a limited amount of data obtained in an operating turbofan engine with the same combustor is made. The comparison is sufficiently favorable to warrant the conclusion that the structure of the combustor pressure field is preserved between the component facility and the engine. Previously announced in STAR as N83-21896

Karchmer, A. M.↗

Thermal diffusivity of diamond films

A laser pulse technique to measure the thermal diffusivity of diamond films deposited on a silicon substrate is developed. The effective thermal diffusivity of diamond film on silicon was measured by observing the phase and amplitude of the cyclic thermal waves generated by the laser pulses. An analytical model is developed to calculate the effective in-plane (face-parallel) diffusivity of a two layer system. The model is used to reduce the effective thermal diffusivity of the diamond/silicon sample to a value for the thermal diffusivity and conductivity of the diamond film. Phase and amplitude measurements give similar results. The thermal conductivity of the films is found to be better than that of type 1a natural diamond.

Albin, Sacharia↗

Thermal diffusivity of diamond films using a laser pulse technique

Polycrystalline diamond films were deposited using a microwave plasma-enhanced chemical vapor deposition process. A laser pulse technique was developed to measure the thermal diffusivity of diamond films deposited on a silicon substrate. The effective thermal diffusivity of a diamond film on silicon was measured by observing the phase and amplitude of the cyclic thermal waves generated by laser pulses. An analytical model is presented to calculate the effective in-plane (face-parallel) diffusivity of a two-layer system. The model is used to reduce the effective thermal diffusivity of the diamonds/silicon sample to a value for the thermal diffusivity and conductivity of the diamond film. The average effective diffusivity values are 1.47 + or - 0.03 and 1.83 + or - 0.10 yielding thermal diffusivity values of 7.46 + or - 0.90 and 7.33 + or - 0.70 sq cm/s respectively, for the two samples; the calculated thermal con ductivity values are 13.50 and 13.28 W/cmK, which are better than that of type 1a natural diamond. The phase and amplitude measurements give similar results.

Albin, Sacharia↗

Pre-Launch Testing of GPS Receivers for Geodetic Space Missions

The methodology used and the results obtained in the pre-flight testing of the Blackjack Global Positioning System (GPS) space receiver for the Vegetation Canopy Lidar Mission (VCL) and the Ice, Cloud, and Land Elevation Satellite (ICESat) spacecraft is described. Both real and simulated signals were used to: (1) assess the accuracy and coverage of the navigation solutions, (2) assess the accuracy and stability of the 1-PPS timing signal, (3) assess the precision of the carrier phase observable, and (4) measure the cold-start time to first fix. In addition, an anechoic chamber was used to measure the antenna phase centers with millimeter-level precision. While the test results have generally been excellent and are discussed in this paper, emphasis is placed on describing the test methodology. It is anticipated that future geodetic satellite missions using GPS for navigation, timing, and precise orbit determination (POD) can employ the same tests for pre-launch performance assessment of their particular receiver.

Davis, George↗

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

A compact submillimeter wave transmission / reflection measurement system has been demonstrated at 560-635 GHz, with electronic tuning over the entire band. Maximum dynamic range measured at a single frequency is 90 dB (60 dB typical), and phase noise is less than +/- 2(deg). By using a frequency steerable lens at the source output and mixer input, the frequency agility of the system can be used to scan the source and receive beams, resulting in near real-time imaging capability using only a single pixel.

submillimeter wave imaging↗

Measurements of the Five-Dimensional Phase Space Distribution of an Intense Ion Beam

No simulation of intense beam transport has accurately reproduced measurements at the level of beam halo. One potential explanation of this discrepancy is a lack of knowledge of the initial distribution of particles in six-dimensional (6D) phase space. A direct 6D measurement of an ion beam was recently performed at the Spallation Neutron Source (SNS) Beam Test Facility (BTF), revealing nonlinear transverse-longitudinal correlations in the beam core that affect downstream evolution. Unfortunately, direct 6D measurements are limited in resolution and dynamic range; here, we discuss the use of three slits and one screen to measure a 5D projection of the 6D phase space distribution, overcoming these limitations at the cost of one dimension. We examine the measured 5D distribution before and after transport through the BTF and compare to particle-in-cell simulations. We also discuss the possibility of reconstructing the 6D distribution from 5D and 4D projections.

Hoover, Austin↗

Observations of the phase variation of Venus CO2 equivalent widths

Equivalent widths determined from photoelectric scans of Venus CO2 absorption lines measured at phase angles of 5.1 to 170 deg are presented. The data-reduction procedure is described in detail, and phase curves are plotted for three model atmospheres in which CO2 is homogeneously mixed with Mie-scattering particles or inhomogeneously mixed with Henyey-Greenstein particles. All three data sets are found to indicate that the equivalent-width maximum occurs at a phase angle much lower than 100 deg. It is concluded that two scattering layers are not required on Venus to explain the shape of the observed phase curve and that the mixing ratio of scattering particles to CO2 increases with depth at high altitudes.

Barker, E. S.↗

Qualification of a Null Lens Using Image-Based Phase Retrieval

In measuring the figure error of an aspheric optic using a null lens, the wavefront contribution from the null lens must be independently and accurately characterized in order to isolate the optical performance of the aspheric optic alone. Various techniques can be used to characterize such a null lens, including interferometry, profilometry and image-based methods. Only image-based methods, such as phase retrieval, can measure the null-lens wavefront in situ - in single-pass, and at the same conjugates and in the same alignment state in which the null lens will ultimately be used - with no additional optical components. Due to the intended purpose of a Dull lens (e.g., to null a large aspheric wavefront with a near-equal-but-opposite spherical wavefront), characterizing a null-lens wavefront presents several challenges to image-based phase retrieval: Large wavefront slopes and high-dynamic-range data decrease the capture range of phase-retrieval algorithms, increase the requirements on the fidelity of the forward model of the optical system, and make it difficult to extract diagnostic information (e.g., the system F/#) from the image data. In this paper, we present a study of these effects on phase-retrieval algorithms in the context of a null lens used in component development for the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission. Approaches for mitigation are also discussed.

Bolcar, Matthew R.↗

Phase and time-resolved measurements of unsteady heat transfer and pressure in a full-stage rotating turbine

This paper presents detailed phase-resolved heat-flux data obtained on rotor blades and a comparison of simultaneously obtained time-resolved heat-flux and static pressure data obtained on the stationary shroud of a Garrett TFE 731-2 HP full-stage rotating turbine. A shock tube is used to generate a short-duration source of heated and pressurized air and platinum thin-film gages are used to obtain heat-flux measurements. Blade results are presented at several selected blade locations. Shroud surface pressure and heat-flux time histories are presented for comparable locations relative to the blade position.

Dunn, M. G.↗

Modeling Broadband Phase Noise from Extended Targets in a 170 GHz Cloud-Imaging Radar

VIPR (Vapor Inside-cloud Profiling Radar) is a differential absorption radar operating over 155-175 GHz, covering a portion of the lower frequency flank of the 183 GHz water vapor absorption resonance. Transmitting at a ~1.9 mm wavelength, VIPR is highly sensitive to scattering from small particles comprising clouds and precipitation. Variation of VIPR’s cloud and precipitation echo power with frequency is often dominated by water vapor absorption, allowing humidity profiles to be retrieved along the radar’s beam path. One confounding effect in practical measurements is phase noise carried by the radar’s transmit signal, which can result in strong range sidelobes extending from bright targets and obscuring the echo signals of more weakly scattering clouds. Here we show that the magnitude and shape of phase-noise induced clutter from extended, bright cloud signals can be accurately modeled using a combination of empirical measurements of surface-echo phase noise and an analytic model based on the phase-noise sidelobe magnitude from a theoretical point target. This improved understanding of a potential clutter source in millimeter-wave imagine radar can lead to better performance modeling, and it provides motivation to improve the phase noise of very high frequency local oscillators.

Cooper, Ken B.↗

A sub-picosecond digital clock monitoring system

We describe a low-cost system designed to monitor wander in digital clocks with a precision of ≤ 1 ps. With this system we have shown that it is possible to track phase variations at the sub-picosecond level by adding noise to a reference clock. As in many cases where a clock is part of a complex distribution network small changes in temperature and other effects can lead to small changes in the clock's phase. As a further demonstration of the system, we have used it to measure the phase changes induced in optical signals in fibers.

47 OTHER INSTRUMENTATION↗

The measurement system of pulse modulated carrier frequency stability and timing jitter

The definition of pulse modulated carrier frequency stability and timing jitter as well as the configuration and synchronous acquisition measurement method of its measurement system. Frequency stability of the pulse modulated carrier is measured with a discrimination technique. The pulse modulated carrier under testing is mixed with a reference frequency synthesizer. A delay line is used to convert the frequency fluctuation mixed IF signal to the voltage fluctuation. The system has the capability to make the phase noise measurement of two port devices on a pulsed carrier using a phase bridge. The noise voltage mentioned above is applied to the data acquisition and processing unit by PC to realize stability measurement. The data acquisition is in the form of pulse synchronization so that the measurement system accuracy is increased. The pulse width is more than 0.3 microseconds. The phase fluctuation variance, sigma, is less than 0.017. The time interval measuring system with high resolution is used to make interpulse timing and pulse width jitters automatic measurement. The pulse width is less than 0.2 ns. The resolution is 0.1 ns. The system is successfully applied to radar measurement.

Li Cheng-Fu↗

Phase Lag and Coherence Function of X-Ray Emission from Black Hole Candidate XTE J1550-564

We report the results from measuring the phase lag and coherence function of X-ray emission from black hole candidate XTE J1550-564. These temporal X-ray properties have been recognized to be increasingly important in providing important diagnostics of the dynamics of accretion flows around black holes. For XTE J1550-564, we found significant hard lag-the X-ray variability in high-energy bands lags behind that in low-energy bands-associated both with broadband variability and quasi-periodic oscillation (QPO) . However, the situation is more complicated for the QPO: while hard lag was measured for the first harmonic of the signal, the fundamental component showed significant soft lag. Such behavior is remarkably similar to what was observed of microquasar GRS 1915+105. The phase lag evolved during the initial rising phase of the 1998 outburst. The magnitude of both the soft and hard lags of the QPO increases with X-ray flux, while the Fourier spectrum of the broadband lag varies significantly in shape. The coherence function is relatively high and roughly constant at low frequencies and begins to drop almost right after the first harmonic of the QPO. It is near unity at the beginning and decreases rapidly during the rising phase. Also observed is that the more widely separated the two energy bands are, the less the coherence function between the two. It is interesting that the coherence function increases significantly at the frequencies of the QPO and its harmonics. We discuss the implications of the results on the models proposed for black hole candidates.

Cui, Wei↗

Multiscale characterization of phase change materials for building thermal energy storage applications

Phase change materials (PCMs) store and release large amounts of thermal energy because of their high latent energy storage capacity. However, long-term cyclic stability, supercooling and performance-scalability are some of the major challenges for their use in building thermal energy storage (TES) applications. Here, in this study, we present a comprehensive multiscale characterization of two commercially available organic PCMs, Puretemp 18 and Puretemp 23. At the microscale, differential scanning calorimetry (DSC) was used to characterize phase change temperature, specific heat, and latent heat. At the mesoscale, a heat flow meter apparatus (HFMA), following the ASTM C1784 standard, was employed to measure the phase change temperature, specific heat, and latent heat properties. A comparative analysis of latent heat as a function of temperature was conducted by integrating the DSC and HFMA results. At the macroscale, the thermal performance and cyclic stability of the TES system was evaluated using Puretemp 23. The TES system consisted of a finned tube heat exchanger with a storage volume of 0.0189 m 3 (5 gal), which represents a compact, real-world TES solution suitable for building energy storage. The results showed consistent thermal stability of the PCM over 200 cycles, and the supercooling temperature remained within 0.2 °C, which was not detected in smaller-scale characterization methods. Additionally, the macroscale testing methodology of the PCM revealed that the TES is able to charge and discharge stored latent energy within 2 h under a temperature differential of 16.67 °C measured between the inlet water temperature and the phase transition temperature of the PCM. The proposed multiscale PCM characterization method provides a systematic basis for comparing important thermal storage properties while also investigating the scalability, reliability and integration challenges in large scale TES applications.

Latent heat↗

Ka-band MMIC beam steered transmitter array

A 32 GHz six element linear transmitter array which employs MMIC phase shifters and power amplifiers is developed and its performance is evaluated. The MMIC phase shifters contains 14 MESFETs in three digital switched line and one analog loaded line phase shifter, and the MMIC power amplifiers are two stage amplifiers using GaAs MESFETs with 0.25 micron gate lengths and gate widths of 0.1 mm and 0.3 mm. The design of the array is described. The phase shift measurements for the MMIC devices are analyzed. The data reveal that the switched line phase shifters are accurate to within 7 pct; the power amplifier 1 dB compressed output power varied over 0.3 dB; the beamwidth of the array is 7.5 deg; and beam steering is over + or - 8 deg.

Riley, A. L.↗

Accuracy of the Residual Delay Absolute Phase Algorithm

Interferometric synthetic aperture radar (IFSAR) has become a useful technology for producing high-quality topographic maps. These measurements are required to reconstruct the three-dimensional coordinate of a point in an IFSAR image: the range, azimuth and elevation. The first is obtained by timing the return of the radar pulse, the second by measuring the doppler shift, and the last by measuring the phase difference between the signals received at two displaced antennae.

IFSAR interferometric synthetic aperture radar top↗