Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Modular Wide-bandgap String Inverters for Low-cost Medium-voltage Transformerless PV Systems

The proposed technology combines advances in wide-bandgap power electronics with breakthroughs in distributed and decentralized control to produce ultra-low-cost medium-voltage transformerless PV inverters that are composed of stackable lightweight blocks. Taken together, the proposed circuit designs and accompanying control strategies will yield integrated control+circuit (C2) blocks, each comprising a converter and local controller, that can be assembled in a modular fashion to obtain distributed conversion interfaces for next-generation commercial and utility-scale PV systems. We will utilize SiC devices to obtain C2 blocks that can individually operate at a voltage and power in excess of 1 kV and 100 kW, respectively, such that ensembles of series-connected blocks perform direct dc to three-phase ac conversion at medium voltages (e.g., 12 kV–35 kV) and at multi-MW power levels.

42 ENGINEERING↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Visibility-enhanced model-free deep reinforcement learning algorithm for voltage control in realistic distribution systems using smart inverters

Increasing integration of distributed solar photovoltaic (PV) into distribution networks could result in adverse effects on grid operation. Traditional model-based control algorithms require accurate model information that is difficult to acquire and thus are challenging to implement in practice. Here, this paper proposes a surrogate model-enabled grid visibility scheme to empower deep reinforcement learning (DRL) approach for distribution network voltage regulation using PV inverters with minimal system knowledge. In contrast to existing DRL methods, this paper presents and corroborates the adverse impact of missing load information on DRL performance and, based on this finding, proposes a surrogate model methodology to impute load information utilizing observable data. Additionally, a multi-fidelity neural network is utilized to construct the DRL training environment, chosen for its efficient data utilization and enhanced robustness to data uncertainty. The feasibility and effectiveness of the proposed algorithm are assessed by considering DRL testing across varying degrees of observable load information and diverse training environments on a realistic power system.

14 SOLAR ENERGY↗

PV encapsulant formulations and stress test conditions influence dominant degradation mechanisms

Polyethylene-based poly(ethylene-co-vinyl acetate) (EVA), polyolefin elastomer (POE), and thermoplastic polyolefin (TPO) are common polymer candidates for photovoltaic (PV) module encapsulants. The choice of encapsulant must be carefully considered in novel module designs, such as bifacial glass/glass laminates, to limit performance degradation through loss of optical transmittance, mechanical integrity, and corrosion - as well as potential-induced degradation. Encapsulant quality and resilience against environmental stressors are readily influenced by the additives in the encapsulant formulation. Here, we show that, the changes in optical transmittance after UV aging result from the discoloration caused by interactions between additives, and optical scattering from changes in the polymer crystal structure. We observed competing cross-linking and chain scission mechanisms, with their kinetics influenced by the presence of oxygen and elevated temperatures. Increasing chamber temperatures from 55 °C to 85 °C during the UV stress test amplified encapsulant discoloration and promoted polymer cross-linking, causing severe, irreversible damage that remains to be proven field relevant. Damp heat aging was found to be insufficient to produce significant encapsulant degradation; however, combining stress tests sequentially allowed detection of further degradation beyond the limitations of the damp heat test alone. Appropriate degradation screening methods are necessary to uncover potential encapsulant weaknesses.

14 SOLAR ENERGY↗

A Comparison of the Optoelectronic Properties of High-Efficiency Polycrystalline and Epitaxial Cu(In,Ga)Se2 Photovoltaic Films

Over the last several decades, champion photovoltaic (PV) devices using CuInGaSe2 (CIGS) as the absorber material have been achieved using polycrystalline films exclusively. This has led to the assumption that polycrystalline CIGS generally outperform single-crystal CIGS in PV devices. However, recently, very high-quality epitaxial CIGS has been grown on GaAs substrates producing PV device efficiencies of 20.0%. These results have revived the debate on what effects grain boundaries have on PV device efficiencies. In this contribution, we compare the optoelectronic properties of polycrystalline CIGS films with those of high-efficiency epitaxial CIGS films. This comparison reveals that grain boundaries are associated with properties that negatively impact PV device efficiency. Additionally, we find that the grain interiors in polycrystalline films exhibit properties that are similar to the high-performance epitaxial films. Our results suggest that it may be possible to achieve higher device efficiencies with epitaxial CIGS than with polycrystalline films.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Conduct Performance Validation of the Electrodynamic Shield (EDS) Induced Cleaning Under Realistic Environmental Soiling Conditions: CRADA Number CRD-21-17861 (Cooperative Research and Development Final Report)

NREL will work with the Participant to perform accelerated long-term durability and other standard durability tests for prototypes to help demonstrate the reliability of the technology for PV applications. NREL will test commercially relevant-sized prototypes under realistic environmental soiling conditions to correlate dust removal efficacy for improving the PV output under standard solar conditions. Measurements will include voltage-current characterization in solar simulators before and after dust cleaning.

14 SOLAR ENERGY↗

GA-Based Voltage Optimization of Distribution Feeder with High-Penetration of DERs Using Megawatt-Scale Units

In this paper, genetic algorithm (GA)-based voltage optimization of a modified IEEE-34 node distribution feeder with high penetration of distributed energy resources (DERs) is proposed using two megawatt-scale reactive power sources. Traditional voltage support units present in distribution grids are not suitable for DER-rich feeders, while voltage support using small-scale DERs present in the feeder requires considerable communication effort to reach a global solution. In this work, two megawatt-scale units are placed to improve the voltage profile across the IEEE 34-node feeder, which has been modified to include several PV units and an energy storage unit. The megawatt-scale units are optimized using GA for fast and accurate operation. The performance of the proposed scheme is verified using simulation results with a multi-platform setup where the modified IEEE-34 node feeder is modeled in OpenDSS while the GA optimization scheme is programmed in MATLAB.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data Quality-Aware Framework to Reliably Forecast Photovoltaic Generation and Consumer Load for an Improved Resilience of Microgrids

Photovoltaic (PV) power and consumer load forecasting plays a critical role to ensure operational resilience of the electric grid. Most data-driven forecasting algorithms rely heavily on the continuous availability of good quality data for periodic training and validation. When deployed at the grid’s edge, prolonged disruptions to communications during extreme events degrade data quality. Factors such as missing observations, epistemic uncertainties, data drift, and concept drift are manifestations of data quality that impact the generalization of such field-deployed forecasting models. Currently, there exists no mechanism in the literature to dynamically switch between models under varying degrees of data quality as quantified by certain metrics for each factor highlighted above. This paper addresses this shortcoming by conceptually introducing a data qualityaware framework for reliable PV generation and consumer load forecasting. The framework’s design incorporates components of missing values, divergence tests, and continuous monitoring of generalization performance to detect changes in data quality caused by communications disruptions and trigger specific classes of forecasting models grouped under three use cases (UC1- UC3). As a first step towards validating this framework, real data collected from an actual field microgrid system is used to demonstrate the viability of the three use cases. Results show that the performance is the best in UC1 with an unadjusted R-square value of 0.954, followed by 0.939 for UC2 and 0.757 for UC3.

Sundararajan, Aditya↗

Long Term Damage Testing (NREL)

DOE's Regional Test Center program has fielded several strings of PV modules as part of their Long Term Testing program. Some of these modules have been installed since 2016 and have been exposed to severe weather events. A key to developing long lifespans for PV modules (in excess of 30 years) is understanding how damage and defects develop, propagate and progress. Researchers at the NREL Regional Test Center have started developing testing procedures and analysis tools in order to characterize modules in a controlled manner with the goal of understanding how damage spreads under normal operations. Characterization methods include EL and IR imaging, outdoor and indoor IV curves, and long term exposure monitoring. Modules to be evaluated will be chosen based on severity of defect, ability to track changes in defect and space requirements. The samples will be loaded at maximum power using grid-tied inverters or other means. Gathering and reporting on this data may help engineers and scientists design for damage and improve long-term performance.

crack damage↗

bifiPV2020 Bifacial Workshop: A Technology Overview

The virtual bifiPV Workshop was held in July 2020 to provide the solar industry with a forum for sharing and discussing research into bifacial photovoltaic (PV) technology. This report outlines major insights from the workshop to give the reader an overview of the latest developments in bifacial PV technology worldwide, from the lab to the field. Citations are drawn from this workshop unless otherwise noted, with all proceedings available online at bifipvworkshop. com. Presentations for the bifiPV2020 Workshop focused on the following areas: bifacial power plant modeling and simulation, albedo improvements, the development of encapsulants, the durability and reliability of current bifacial technologies, performance comparisons between glass-glass and glass-transparent backsheet configurations, the future of passivated emitter and rear contact (PERC) solar cells, and the growing adoption of n-type solar cells. With 650 GW total PV installed worldwide and 1 TW to come very soon, PERC is now the standard PV cell type produced en masse. However, it is already reaching 23% efficiency, the upper limit for this type of technology. PV modules breaking the 0.5-kW barrier are starting to appear, and the costs of standard PERC technology are already below 0.2 USD/Wp. In 2019, five GW of bifacial PV were installed worldwide. In 2020, the majority of bifacial installations are expected to be located in the United States, China, and Middle East and North Africa (MENA) states. N-type bifacial technologies are becoming increasingly viable and have huge potential to dominate the market in the coming years. With bifacial technology mounted on horizontal single-axis trackers (HSAT), bids below 10 USD/MWh will soon be observed in the MENA region, and later in Chile and the United States. Factory audits and reliability testing can reduce field failures by helping buyers to select producers that follow rigorous quality assurance and quality control processes.

14 SOLAR ENERGY↗

Cracked Solar Cell Performance Depends on Module Temperature

When cells in a crystalline silicon photovoltaic module crack, packaging materials hold the fragments together. Changes in module temperature cause cell fragments to move, allowing cracked metallization to lose and regain contact. We intentionally cracked cells in commercial PV modules and characterized the modules’ temperature-dependent electroluminescence (EL) response. Here we show that (1) metallization makes contact across cracks in a way that is temperature dependent and (2) this contact is not a function of temperature, but is hysteretic. We expect that any electro-optical characterization made at a single temperature will be misleading as to the effects of cracked cells at different temperatures. And we expect that a single temperature sweep cannot fully characterize the temperature dependence of electro-optical performance of modules with cracked cells.

crack↗

PV Validation Hub

The Validation Hub will be a clearinghouse for the transfer of novel algorithms and software from the PV research community to industry. Potential algorithms tested in the Hub could include the estimation of various PV loss factors and the detection of various operational issues. The primary function of the Hub will be for developers to submit executable code which will run on hosted data sets. Developers will receive private reports on the accuracy and performance (e.g., run-time) of the submitted algorithms, and public high level summaries will be hosted. These summaries will indicate the organization who submitted the algorithm (e.g., links to GitHub pages, documentation websites, etc.), high-level accuracy metrics, and standardized performance metrics. These results will be stored in a publicly available database, accessible through the Hub, with the ability for users to sort and filter the results. In short, the Hub will be presented to public users as a collection of interactive leaderboards, organized around specific analysis tasks pertinent to the PV data science community. These tasks include things such as the estimation of various PV loss factors and the detection of various operational issues. We will present progress on the development of this hub, including preliminary results of comparative validation of PV data science algorithms and progress towards building the platform itself.

algorithm↗

Regional Real-Time PV Spinning Reserve Estimator

Curtailed photovoltaic (PV) generation is a zero-marginal-cost spinning reserve that can be used for a number of active power control services. Unlike traditional spinning reserve providers, however, i.e., fossil-fueled generators, which have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate knowledge of the PV PHL is essential. It ensures that enough headroom is reserved by the PV plants to deliver the award services in real time and informs feasible dispatch decisions made by the market operator. To tackle this challenge, a novel reference-control grouping-based PV plant reserve estimation method has been proposed by the National Renewable Energy Laboratory under past projects funded by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office. The estimation method separates inverters within a plant into two groups: a control group and a reference group. While the reference group is reserved to operate at its PHL, the control group can be curtailed to provide the grid services. Real-time outputs from the reference inverters are used to estimate the PHL for the whole plant based on the ratio between capacities of the reference group and of the plant. This work further enhances the methodology by (1) improving the model accuracy through machine learning; (2) automating the reference inverter selection through correlation analysis; (3) considering estimation look-ahead windows; and (4) applying to regional spinning reserve estimation. Significant performance improvement has been observed based on real-world data collected by CAISO, Southern Company, and Terabase Energy. Compared with the original scaling method, the newly proposed machine learning-based approach reduces the estimation errors by 30% and 13% at the plant level and region level, respectively. Results obtained from this project are intended to be used by grid operators, market operators, balancing authorities, and PV plant owners and operators to facilitate PV participation in ancillary service markets. Regulators, policymakers, and system planners can also consider the results of this work in their decision-making processes. In addition to the performance improvement on the existing reference-control based grouping method, we also investigated how the variability of PV generation from a single PV inverter can be used to represent the variability of PV generation at the plant level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Model for Evaluating the Configuration and Dispatch of PV Plus Battery Power Plants

An open-source model was developed to optimize energy storage operation for photovoltaic- (PV-) plus-battery systems with AC-coupled and DC-coupled configurations. It includes the ability to use forecast energy prices to optimize battery charge and discharge on a rolling time horizon. The model allows for exploration of different configurations, including capital costs, inverter performance, dispatch flexibility, and capturing otherwise clipped energy for the DC-coupled system. The model can run 20 full years of hourly data in approximately two seconds, allowing comparison of a large number of configurations. We applied the model in a test case demonstrating reduced inverter clipping for DC-coupled systems and yielded slightly higher overall value than AC-coupled systems, with an approximately 2 percent increase in internal rate of return or benefit/cost ratio. Our results show that at current estimated prices for lithium-ion battery systems, large-scale PV-plus-battery plants are economically viable under the right conditions, with the configuration playing a role in system flexibility and performance. This model provides the ability for project developers, industry professionals, and researchers to use readily available software to quickly evaluate and design these systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Comparative Life Cycle Analysis of Scalable Single-Junction and Tandem Perovskite Solar Cell (PSC) Systems

Efficient, low-cost solar cells based upon perovskites have the potential to transform the US and global energy portfolio and improve energy security if they can be manufactured in an environmentally sustainable manner. However, previous life cycle analyses (LCA) of perovskite solar cells (PSC) used lab recipes to project the environmental impact of industrial PSC production – using materials and processes that may not be representative of industrial productions due to high material waste and complex synthesis – and such studies were limited to a few single-junction technologies. Thus, the goal of this project was threefold: a) to review the most promising for industrial production single-junction and tandem PSC technologies, b) to build life-cycle materials inventories that reflect scalable production of these technologies, and c) to conduct comprehensive life-cycle analysis of these technologies and compare their environmental impact with those of established commercial technologies. In response, this project identified challenges for fabrication transitioning from laboratory to sustainable industrial production, developed life-cycle inventory (LCI) data for scaling to industrial production four promising single-junction and three tandem PSC systems and produced life-cycle-investigations using, as metrics, a complete spectrum of energy, environmental and ecological impact indicators. Special focus was given to the use of lead, silver and indium in PSC. The project used the Life Cycle Assessment (LCA) methodology as standardized by the Society of Environmental Toxicology and Chemistry (SETAC), ISO standards 14040 and 14044, and the International Energy Agency PVPS Task 12 LCA guidelines. LCA allows the calculation of a number of energy and environmental and impact categories, including energy cumulative energy demand (CED), global warming potential (GWP), human toxicity potential (HTP), eco-toxicity potential (ETP), abiotic resource depletion potential (ADP), acidification potential (AP), ozone depletion potential (ODP), photochemical oxidation potential (POP), eutrophication potential (EP). In addition to those, we calculated the Energy Pay-Back Time (EPBT) and the Energy Return On Investment (EROI). We provide LCA impacts for complete perovskite PV systems – including balance of system components – installed at three irradiation levels and considering reference and future potential module efficiencies. Finally, a sensitivity analysis on perovskite lifetime has been performed, considering 10, 20 and 30 years. Contribution analysis of the impacts of each material and layer of PSC shows, that the use of Pb in metalorganic PSC does not result in significant environmental impacts as the major contributions to environmental indicators arise from the use of Ag and encapsulation materials. Solution-based PSC manufacturing was found to be less impactful to the environment than vapor-based fabrication, and roll-to-roll (RtR) printing uses less energy and generates the lowest emissions. PSC produced with RtR manufacturing could reach the same Energy Return on Energy Investment (EROI) as that of crystalline-Si PV within 12 years of life, whereas the most energy demanding spray coating on rigid substrates, would require a 20-yr life to match the EROI of 30-yr lasting silicon PV. This work lays the foundation for sustainability investigations in a comparative context of large-scale production and deployment of PSC. The results of this project have the potential to have a significant impact on the future of PV manufacturing, by providing industry, policy-makers, and academia with insights necessary to choose which, if any, lead-based solar cell life cycles are environmentally sustainable.

14 SOLAR ENERGY↗

Networked Microgrids for Improved Resilient Operation: A Case Study in Adjuntas Puerto Rico

This paper presents a case study of a network microgrid orchestrator designed to allow coordinated operation of microgrids. Through Control Hardware in the Loop (CHIL), the proposed microgrid orchestrator was validated using, as case study two community-owned microgrids in Adjuntas, Puerto Rico. These two microgrids in Adjuntas were designed to provide affordable and reliable access to electricity to 14 businesses located in the town square. In its current design, these two microgrids operate independently from each other. This paper studies how networking them would increase their resiliency metrics while operating as an island. A distributed optimization is implemented in the microgrid orchestrator due to its superior scalability compared to centralized approach as well as to maintain data privacy. Two operational modes are considered in this study to showcase the advantages of networking microgrids: a) normal island, and b) degraded island. CHIL simulations are performed to validate the proposed microgrid orchestrator. CHIL results show meaningful resiliency improvements obtained by networking microgrids during contingencies such as loss of PV generation.

Ferrari Maglia, Max↗

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.

harmonics, power quality, load modeling↗