Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

ESPC ESA Case Study: Energy Affordability at the National Institute of Standards and Technology

The U.S. Department of Commerce (DOC) National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland, installed a 5 MW-DC photovoltaic (PV) system under an energy savings performance contract energy sales agreement (ESPC ESA). The project was implemented using the U.S. Department of Energy (DOE) ESPC ENABLE contract vehicle. This project provides an example of the benefits of using an ESPC ESA to reduce project costs and provide the best value to the government, allowing the system owner to monetize tax incentives such as the federal investment tax credit (ITC) and Modified Accelerated Cost Recovery System (MACRS), and use or sell the solar renewable energy certificates (SRECs).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

7 Steps to Selecting a Solar Provider

This fact sheet highlights seven best practices to help business owners across sectors select a commercial solar provider. This step-by-step guide includes resources and tips for installing an on-site solar photovoltaic (PV) system, including defining project goals, developing and issuing a request for proposal (RFP), shortlisting providers, etc.

Solar, Solar PV, Commercial, Renewable Energy, Ren↗

Greenhouse gas emissions embodied in the U.S. solar photovoltaic supply chain

Abstract Solar photovoltaic (PV) electricity is considered to be an important source of electricity generation in the quest for net-zero carbon emissions. However, the growth of solar electricity is creating both increased material demands and increased greenhouse gas (GHG) emissions from silicon and PV manufacturing (also referred to as embodied GHG emissions of solar electricity). Here we analyze the silicon and solar PV supply chain for the United States (U.S.) market and find that the embodied GHG emissions of solar PV panel materials (such as silicon), manufacture, logistics, and installation in the U.S. given the current supply chain are 36 g CO 2 e kWh −1 of solar electricity generated. Eighty-five percent of the embodied GHG emissions are from PV panel production processes in China and other Asia–Pacific countries. Moving the silicon and PV manufacturing to the U.S. would reduce the embodied GHG emissions of solar electricity by 16% from its current level, primarily because of the lower GHG emission intensity of the U.S. electrical grid and the lower GHG emissions for aluminum electrolysis in North America. Future scenario analysis shows that by 2030, with the U.S. PV domestic supply chain and its decarbonized grid electricity and aluminum production, as well as improving PV conversion efficiency, the embodied GHG emissions of solar electricity in the U.S. will be reduced to 21 g CO 2 e kWh −1 .

14 SOLAR ENERGY↗

Knowledge-Based Hazardous Waste Determinations for Solar Photovoltaic (PV) Modules: A Foundational Study

This report explores using "generator knowledge" to determine whether a solar photovoltaic (PV) module must be managed as hazardous waste prior to recycling or landfilling. Generator knowledge is a legal term and existing regulatory pathway for making a hazardous waste determination that has been used by other industries but is a relatively unknown option to the PV industry. In the United States, a hazardous waste determination often acts as a pre-requisite to recycle or landfill a PV module. The results of the hazardous waste determination dictate whether the PV module must be managed as hazardous waste or nonhazardous solid waste. Managing a PV module as hazardous waste requires compliance with stringent U.S. federal and state hazardous waste law. In addition to increased management costs, which can be ten times higher, legal liability for PV modules regulated as hazardous waste is also heightened with both civil and criminal penalties for noncompliance which includes making an inaccurate or faulty hazardous waste determination. The most common reason a PV module would be regulated as hazardous is if it contains a regulated metal in an amount that equals or exceeds the toxicity characteristic limits. To determine whether a PV module exhibits a hazardous characteristic, the regulated person/entity must "apply knowledge...in light of the materials and processes used." In the absence of adequate knowledge to determine whether the PV module is hazardous, it must be tested using Test Method 1311 Toxicity Characteristic Leaching Procedure (TCLP) or an equivalent EPA-approved method. Although TCLP is the predominant method used to today to make a hazardous waste determination for PV modules, evidence from this study concludes it is not practical to TCLP test every PV module even in a single utility-scale installation, and a scalable solution is needed. This study finds that knowledge-based hazardous waste determinations may allow a regulated person/entity to make a hazardous waste determination for more than one PV module at one time - making this regulatory pathway a potential scalable solution. Through legal analysis and interviews with 44 experts, the authors explore what it means to make an accurate knowledge-based hazardous determination for PV modules considering sources and forms of information as well as potential limitations. The work aims to provide a foundation for building consensus on whether knowledge-based hazardous determinations are a viable, scalable industry approach for solar.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Equilibrium thermal characteristics of a building integrated photovoltaic tiled roof

Photovoltaic (PV) modules attain high temperatures when exposed to a combination of high radiation levels and elevated ambient temperatures. The temperature rise can be particularly problematic for fully building integrated PV (BIPV) roof tile systems if back ventilation is restricted. PV laminates could suffer yield degradation and accelerated aging in these conditions. This paper presents a laboratory based experimental investigation undertaken to determine the potential for high temperature operation in such a BIPV installation. This is achieved by ascertaining the dependence of the PV roof tile temperature on incident radiation and ambient temperature. A theory based correction was developed to account for the unrealistic sky temperature of the solar simulator used in the experiments. The particular PV roof tiles used are warranted up to an operational temperature of 85 C, anything above this temperature will void the warranty because of potential damage to the integrity of the encapsulation. As a guide for installers, a map of southern Europe has been generated indicating locations where excessive module temperatures might be expected and thus where installation is inadvisable. (author)

14 SOLAR ENERGY↗

Modeling and Analysis of Clean Energy and Storage Technologies (CRADA Final Report, Project 1)

The goal of this project is to provide Southern Company Services, Inc. ("Participant") with custom scripts that can be used to create an average PV energy production profile, calculate lifetime energy value, calculate capacity value, and calculate the resultant financial metrics considering those value streams. Secondly, a fuel-cell model will be added to the public version of System Advisor Model (SAM). This standalone technology will incorporate PV and battery storage, allowing the participant to model the interaction of these three technologies. By adding this capability to a public version of SAM, a broad audience will be able to consider the system performance and financial benefits of installing a fuel cell as a baseline generator with PV. Thirdly, automated dispatch algorithms will be developed and added to SAM. These algorithms will enable Southern Company to dispatch a DC-connected front-of-the-meter battery system while considering price signals and PV clipping behavior. By adding these capabilities to a public version of SAM, users will be able to consider more complex and realistic ways of dispatching a battery system.

14 SOLAR ENERGY↗

The Future of Renewable Energy Generation: Photovoltaic Materials

There are myriad ways to harness solar energy, including, but not limited to: solar thermal, solar fuels, and photovoltaics (PV). Across the portfolio of solar energy technologies, PV is unique in that collected photons are directly converted to electricity. Traditionally, the dominant materials in PV are also the dominant semiconductor and optoelectronic materials. The cost of solar energy from PV is a product of a complex combination of non-material related factors, known as soft costs, e.g., permitting, zoning, and of balance-of-systems (BOS) costs, like inverters or other components needed to utilize cells and modules. While the soft costs are due to administrative/regulatory concerns, BOS costs are driven by details of cell/module fabrication, mounting, power electronics, and other concerns, which touch on a range of basic material science issues. There is some overlap of BOS and soft cost, as a lighter weight solar panel can reduce installations costs, as an example. At the PV-system level, the materials considerations span both electronic and structural components. The focus of this paper is the solar cell, which is the minimum operational unit device that converts light into electricity.

30 DIRECT ENERGY CONVERSION↗

Chapter 8: A 'Global' View on Bifacial Gain: Dependence on Geographic Location and Environmental Conditions

The simulation results presented in this chapter demonstrate how bifacial PV systems can bring a performance gain all around the globe, resolving a certain misbelief that they may only form a niche market restricted to specific locations or installations. Global predictions, based on irradiance, indicate bifacial gains in the order of 50% of the natural albedo for equator-facing systems with optimized tilt angle. In locations with low clearness index, the bifacial gain can even be higher. At system level the bifacial gain will be reduced by 20% to 50% relative to a free-standing panel, due to increased self-shading and to limitation of the diffuse irradiance on the rear by adjacent sheds. Even though the rear side irradiance of a bifacial module is inherently inhomogeneous, due to self-shading and external mounting structures, our simulations have shown that the RSD of the total irradiance does not exceed 5%, even at very high albedo, and will usually be much smaller. The simulation methods applied in this chapter and their ongoing integration into commercially available software tools, like PVsyst, will give system designers and installers more visibility on the configuration layout of a bifacial PV plant at their specific location, the associated bifacial gain and the effect on their return on investment.

14 SOLAR ENERGY↗

A New Remote Communications Link to Reduce Residential PV Solar Costs

Monitoring of PV/DER site production is expensive to install and unreliable. Among third party systems providers, lost communications links are a growing concern. Nearly 20% of links are failing, provisioning is complex, recovery is expensive, production data is lost, and access is fragmented. FleetLink is a new concept in DER system communications, purpose built for lowering the cost of maintaining active contact with residential end user sites and ensuring that production data is reliably available to third party systems providers. Systems providers require accurate, secure system monitoring and reporting of production data and system faults while driving down overall costs to compete effectively. This plug and play, independently operating communications solution lowers the cost of fleet contact from typically .08 dollars-$.12/W down to .02 dollars -.03/W including installation and maintenance expenses. FleetLink establishes a breakthrough in simplicity that facilitates rapid expansion of residential solar by reducing initial capital outlay and lowering installation labor time and skill levels. The solution also facilitates higher DER installation growth rates by driving down maintenance costs and eliminating communications trouble calls. This is accomplished by the FleetLink’s unique network technology that enables dynamic network configuration for fast changes, and active, self-healing DER site contact for uptime assurance. Using an open source network framework with proprietary, application specific enhancements, FleetLink independently manages connectivity, security, recovery, grid control communications, and fleet expansion while presenting a compliant SunSpec interface to the third party operations centers. The net system cost savings of at least .05 dollars/W supports the SunShot cost goals and the flexibility and scalability of the solution accelerates the velocity and ubiquitous adoption of solar.

14 SOLAR ENERGY↗

Photovoltaic Manufacturing Consortium (PVMC) – Enabling America’s Solar Revolution

The U.S. Photovoltaic Manufacturing Consortium (US-PVMC) is an industry-led consortium which was created with the mission to accelerate the research, development, manufacturing, field testing, commercialization, and deployment of next-generation solar photovoltaic technologies. Formed as part of the U.S. Department of Energy's (DOE) SunShot initiative, and headquartered in New York State, PVMC is managed by the State University of New York Polytechnic Institute (SUNY Poly) at the Colleges of Nanoscale Science and Engineering. PVMC is a hybrid of industry-led consortium and manufacturing development facility, with capabilities for collaborative and proprietary industry engagement. Through its technology development programs, advanced manufacturing development facilities, system demonstrations, and reliability and testing capabilities, PVMC has demonstrated itself to be a recognized proving ground for innovative solar technologies and system designs. PVMC comprises multiple locations, with the core manufacturing and deployment support activities conducted at the Solar Energy Development Center (SEDC), and the core Si wafering and metrology technologies being headed out of the University of Central Florida. The SEDC provides a pilot line for proof-of-concept prototyping, offering critical opportunities to demonstrate emerging concepts in PV manufacturing, such as evaluations of innovative materials, system components, and PV system designs. The facility, located in Halfmoon NY, encompasses 40,000 square feet of dedicated PV development space. The infrastructure and capabilities housed at PVMC includes PV system level testing at the Prototype Demonstration Facility (PDF), manufacturing scale cell & module fabrication at the Manufacturing Development Facility (MDF), cell and module testing, reliability equipment on its PV pilot line, all integrated with a PV performance database and analytical characterizations for PVMC and its partners test and commercial arrays. Additional development and deployment support are also housed at the SEDC, such as cost modeling and cost model based development activities for PV and thin film modules, components, and system level designs for reduced LCOE through lower installation hardware costs, labor reductions, soft costs and reduced operations and maintenance costs. The progression of the consortium activities started with infrastructure and capabilities build out focused on CIGS thin film photovoltaics, with a particular focus on flexible cell and module production. As marketplace changes and partners objectives shifted, the consortium shifted heavily towards deployment and market pull activities including Balance of System, cost modeling, and installation cost reduction efforts along with impacts to performance and DER operational costs. The consortium consisted of a wide array of PV supply chain companies from equipment and component suppliers through national developers and installers with a particular focus on commercial scale deployments (typically 25 to 2MW installations). With DOE funding ending after the fifth budget period, the advantages and disadvantages of such a consortium is detailed along with potential avenues for self-sustainability is reviewed.

14 SOLAR ENERGY↗

Conceptual Design and Rationale for a New Agrivoltaics Concept: Pastured-Raised Rabbits and Solar Farming

Land-use conflicts created by the growth of solar photovoltaics (PV) can be mitigated by applying the concept of agrivoltaics, that is, the co-development of land for both PV and agricultural purposes, to commercial-scale solar installations. In this study, we present a conceptual design for a novel agrivoltaic system based on pasture-fed rabbit farming and provide the technical, environmental and economic analyses to demonstrate the viability of the concept. Included in our analysis are the economic advantages to the PV operator of grazing rabbits at a density sufficient to control vegetative growth, thus reducing the economic and environmental costs of mowing; the dual-revenue stream from the sale of both rabbits and electricity, contrasted with estimates of the capital-investment costs for rabbits co-located with, and also independent of, PV; and the economic value to the rabbit farmer of higher colony-growth rates (made possible by the shading and predator protection provided by the PV arrays and of reduced fencing costs, which are the largest capital cost, by being able to leverage the PV systems for rabbit fencing. We also provide an environmental analysis that suggests that rabbit-PV farming is a pathway to a measurable reduction in agriculturally-generated greenhouse-gas emissions. Here, our calculations indicate that the co-location of solar and rabbit farms is a viable form of agrivoltaics, increasing overall site revenue by 2.5%-24.0% above projected electricity revenue depending on location and rental/ownership of rabbits, while providing a high-value agricultural product that, on a per weight basis, has significantly less environmental impact than cattle.

14 SOLAR ENERGY↗

Disaggregating Customer-Level Behind-the-Meter PV Generation Using Smart Meter Data and Solar Exemplars

Customer-level rooftop photovoltaic (PV) has been widely integrated into distribution systems. In most cases, PVs are installed behind-the-meter (BTM), and only the net demand is recorded. Therefore, the native demand and PV generation are unknown to utilities. Separating native demand and solar generation from net demand is critical for improving grid-edge observability. In this paper, a novel approach is proposed for disaggregating customer-level BTM PV generation using low-resolution but widely available hourly smart meter data. The proposed approach exploits the strong correlation between monthly nocturnal and diurnal native demands and the high similarity among PV generation profiles. First, a joint probability density function (PDF) of monthly nocturnal and diurnal native demands is constructed for customers without PVs, using Gaussian mixture modeling (GMM). Deviation from the constructed PDF is utilized to probabilistically assess the monthly solar generation of customers with PVs. Then, to identify hourly BTM solar generation for these customers, their estimated monthly solar generation is decomposed into an hourly timescale; to do this, we have proposed a maximum likelihood estimation (MLE)-based technique that utilizes hourly typical solar exemplars. Leveraging the strong monthly native demand correlation and high PV generation similarity enhances our approach's robustness against the volatility of customers’ hourly load and enables highly-accurate disaggregation. Furthermore, the proposed approach has been verified using real native demand and PV generation data.

14 SOLAR ENERGY↗

NREL Benchmarks the Installed Cost of Residential Solar Photovoltaics with Energy Storage for the First Time

Fact sheet summarizing technical report TP-7A40-67474. New National Renewable Energy Laboratory research fills a gap in the existing knowledge about barriers to PV-plus-storage systems by providing detailed component- and system-level installed cost benchmarks for systems in the first quarter of 2016. The report is meant to help technology manufacturers, installers, and other stakeholders identify cost-reduction opportunities and inform decision makers about regulatory, policy, and market characteristics that impede PV-plus-storage deployment.

14 SOLAR ENERGY↗

Initial Results from the Floating Potential Measurement Unit aboard the International Space Station

The Floating Potential Measurement Unit (FPMU) is a multi-probe package designed to measure the floating potential of the 1nternational Space Station (ISS) as well as the density and temperature of the local ionospheric plasma environment. The role oj the FPMU is to provide direct measurements of ISS spacecraft charging as continuing construction leads to dramatic changes in ISS size and configuration. FPMU data are used for refinement and validation of the ISS spacecraft charging models used to evaluate the severity and frequency of occurrence of ISS charging hazards. The FPMU data and the models are also used to evaluate the effectiveness of proposed hazard controls. The FPMU consists of four probes: a floating potential probe, two Langmuir probes. and a plasma impedance probe. These probes measure the floating potential of the ISS, plasma density, and electron temperature. Redundant measurements using different probes support data validation by inter-probe comparisons. The FPMU was installed by ISS crewmembers, during an ExtraVehicular Activity, on the starboard (Sl) truss of the ISS in early August 2006, when the ISS incorporated only one 160V US photovoltaic (PV) array module. The first data campaign began a few hours after installation and continued for over five days. Additional data campaigns were completed in 2007 after a second 160V US PV array module was added to the ISS. This paper discusses the general performance characteristics of the FPMU as integrated on ISS, the functional performance of each probe, the charging behavior of the ISS before and after the addition of a second 160V US PV array module, and initial results from model comparisons.

Wright, Kenneth H., Jr.↗

Case Study: The Tower Companies' Commercial Office Solar PV

This case study describes how the Tower Companies selected and successfully executed onsite solar photovoltaic installations at its commercial office properties and highlights the resulting increase in asset value.

solar, solar PV, photovoltaic, onsite solar, comme↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Model Development of Degradation of PV Modules Backsheet with Locating Place of Module

Performance of a photovoltaic (PV) module is related to the micro-environment around the module. The position of photovoltaic modules in an array row have a large effect on the yellowing and gloss of PV module backsheet exposed in Dfa climatic zone (Gaithersburg, MD) with a polyethylene naphthalate (PEN) outer layer. Stress/Response models of yellowing and gloss-losing as function of location parameters of module, including the shed, row, measurement position in a same module and the distance of module location to the row center, are under development. The module installation height had the greatest influence on degradation of PEN PV backsheet in the Dfa climatic zone. The module backsheets at the end of an array have higher degradation rate (edge effect). The edge effect decreases with increasing of module installation heights.

14 SOLAR ENERGY↗