A review of Sb 2 Se 3 photovoltaic absorber materials and thin-film solar cells

Energy generated from environmentally friendly, cost-effective solar cells is a key aspect for developing a clean renewable-energy economy. Non-toxic and Earth-abundant materials with high absorption coefficient (>10 5 cm -1 ) and optimal bandgap (1-1.5 eV) have received great attention as photovoltaic (PV) absorber layers during the last few decades. Among them, antimony selenide (Sb 2 Se 3 ) has been a promising PV absorber, with steadily increasing power-conversion efficiency (PCE) compared to other emerging compounds. Very recent studies showed that high-quality ZnO:Al/ZnO/CdS/TiO 2 /Sb 2 Se 3 /MoSe 2 /Mo devices with PCE of 9.2% can be fabricated using cost-effective novel compounds. Considering these recent advances, this article provides an overview of the material properties of Sb2Se3 thin films and the recent progress made with Sb 2 Se 3 -based solar cells. Furthermore, analysis of Sb 2 Se 3 -based thin-film solar cells has also shown that the devices have relatively good light management due to their suitable bandgap and high absorption coefficient, whereas carrier management, i.e. collection efficiency of photo-generated carriers, needs significant improvement. Overall, this study provides background knowledge on material properties and device performance and suggests main research directions to overcome the limiting factors of solar cell performance.

14 SOLAR ENERGY↗

Utility-Scale Solar, 2024 Edition: Empirical Trends in Deployment, Technology, Cost, Performance, PPA Pricing, and Value in the United States [Slides]

Berkeley Lab’s “Utility-Scale Solar, 2024 Edition” presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC (PV plants of 5 MWAC or less, including residential rooftop systems, are covered separately in Berkeley Lab’s companion annual report, Tracking the Sun). Key findings from this year’s report include: -18.5 GWAC of new utility-scale PV capacity came online in 2023, bringing cumulative installed capacity to more than 80.2 GWAC across 47 states. Installed costs continued to fall in 2023. Relative to 2022, capacity-weighted averages decreased by 8% to -$\$1.43$/WAC (or $\$1.08$/WDC). Costs, based on a 7.1 GWAC sample of 76 plants completed in 2023, have fallen by 75% (averaging 10% annually) since 2010. Plant-level capacity factors vary widely, from 6% to 36% (on an AC basis), with a sample median of 24%. -Levelized cost of energy (LCOE) of new 2023 projects increased slightly to $\$46$/MWh prior to the application of tax credits but continued to fall to $\$31$/MWh when accounting for federal incentives. PPA prices have largely followed the decline in solar’s LCOE over time, but newly signed longer-term PPA prices have increased since 2021, to an average of $\$35$/MWh (levelized, in 2023 dollars). -Solar’s average energy and capacity value (i.e., ability to offset costs of other power generation sources) across the U.S. was $\$45$/MWh in 2023. Solar’s average market value was lowest in CAISO ($\$27$/MWh), the market with the greatest solar generation share, and highest in ERCOT ($\$67$/MWh). -Newer solar projects had greater market value in 2023 than their generation costs, yielding $\$1.1$ billion in benefits. Projects built in 2022 delivered on average $\$15$/MWh more market value than their costs in 2023. -Solar’s combined value from wholesale electricity markets, public health and climate damage reduction were greater than generation costs and incentives, yielding $\$13.7$ billion in net benefits in 2023. We estimate U.S. health benefits of $\$24$/MWh and reduced global climate damages of $\$101$/MWh. -Adding battery storage is one way to increase the value of solar. Deployment of 52 new PV+battery hybrid plants set a record with 5.3 GW installed in 2023. Our public data file tracks metadata and PPA prices from more than 100 PV+battery hybrid projects that are already online or that have secured offtake arrangements. -Looking ahead, a massive pipeline of at least 1,085 GW of solar capacity dominates the nation’s interconnection queues at the end of 2023. Nearly 571 GW, or 53%, of that total was paired with a battery – in CAISO it was a staggering 98%. Historically only 10% of the requested solar capacity is built. -For more information, and to explore related interactive data visualizations, go to utilityscalesolar.lbl.gov.

14 SOLAR ENERGY↗

The National Climate Database (NCDB): An Unbiased 100-Year Dataset for PV Modeling

In this study, we develop a statistical technique to downscale the future projection of solar irradiance for photovoltaics (PV) energy-related applications. A set of Regional Climate Model (RCM)-based projections obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) are used as inputs to statistical methods to generate high-resolution global horizontal irradiance (GHI) over the contiguous United States (CONUS). The main steps of the statistical downscaling method include (1) regridding RCM output (0.22 degree and daily resolutions) to handle the modeled-observed data sets on a common grid, (2) correcting bias of RCM GHI using satellite-derived observation, and (3) implementing temporal and spatial downscaling to generate GHI at 8-km and hourly resolution. Basically, complex physical processes and interactions between solar radiation and various atmospheric constituents lead solar irradiance to be highly variable and uncertain. Underrepresentation of clouds from the RCM parameterizations is the main source of error and uncertainty in modeling solar irradiance. Thus, we adapt and use the high-quality satellite-derived data from the National Solar Radiation Database (NSRDB) to analyze the bias and error of RCM GHI as well as estimate the statistical parameters for spatial and temporal downscaling. This presentation will summarize the comprehensive analysis conducted to produce and assess the results under two climate scenarios (RCP4.5 and RCP8.5). We will also present a detailed validation demonstrating the strengths of the downscaling method, a summary of the 100-year dataset from 2001-2100, and future extension of this research.

bias correction↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Analysis of Nuclear Fuel Cycle Data

Electricity generated using nuclear power accounted for 18.9% of all electricity consumed in the United States in 2021, putting it in third place behind natural gas (38%) and coal (22%) power plants. Nuclear power plants boast a significantly higher uptime or capacity factor—90% and above—compared to 49.1% for coal fired power plants and 56.6% for natural gas power plants. Renewable energy sources, such as solar photovoltaic (PV) and wind electricity, have lower capacity factors: 24.9% and 36.3%, respectively. In addition, nuclear power is cleaner than both coal and natural gas fired power plants. With the passing of the 2022 Inflation Reduction Act, significant tax credits will be claimed by producers of hydrogen with well-to-gate greenhouse gas (GHG) emissions below 0.45 kg CO 2e /kg H 2 . This has sparked interest in using clean sources of electricity, including nuclear power, to generate H 2 via water electrolysis. As uranium is a primary fuel for modern nuclear power plants, the upstream emissions from nuclear fuel production greatly impact the GHG emissions related to all nuclear power end use. Therefore, it is important to accurately determine the upstream emissions associated with the nuclear fuel cycle of nuclear power production in the United States. In this analysis, the nuclear fuel cycle was separated into distinct steps to allow better understanding of the chemical and energy inputs at each step of the fuel cycle. This also provides details of the GHG emissions at each step in the nuclear fuel cycle. The transportation distance for each step of the fuel cycle was updated to account for the locations of uranium processing facilities along the supply chain of the current U.S. nuclear power plants. Finally, all the updated values were incorporated into Argonne National Laboratory’s Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerated reliability tests of n + and p + poly-Si passivated contacts

We report on the stability of encapsulated, low-pressure chemical vapor-deposited phosphorus (n + poly-Si) doped and boron (p + poly-Si) doped poly-Si/SiO x passivated contacts by exposing the samples to three different accelerated tests: damp heat test, thermal cycling and ultraviolet exposure, adhering closely to the IEC 61215 standard. Outdoor testing was also performed by exposing the samples in the outdoor testing field at the National Renewable Energy Laboratory, and preliminary data accumulated for 1000 h from February to April of 2021 is reported. We studied non-metallized, thermally-metallized, and screen-printed n + and p + poly-Si by monitoring the effective minority carrier lifetime at the implied maximum power point using a Sinton lifetime tester, and recorded photoluminescence images before and after the exposure. Furthermore, the samples were found to be stable under all test conditions, which is encouraging for incorporation of these contacts in next-generation industrial silicon solar cells.

14 SOLAR ENERGY↗

Impact of High Penetration Distributed Energy Resources on the Bulk Electric System

The growth of distributed energy resources (DERs), mostly generation using intermittent renewable energy sources, along with the retirement of central generation (mostly conventional power plants using fossil-fuel-based resources) has implications for the steady-state and dynamic performance of the bulk electric system (BES). Among the DERs connected to the distribution system, photovoltaic (PV) systems are the most prevalent and have been installed at an increasing rate. Until recently, the penetration levels of DERs have not been high enough to create significant impacts on the reliability and security of power system operation. However, in recent years, the penetration levels of DERs have risen to a level that their impacts on the bulk electric system should be considered in a detailed fashion in planning and operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility-Scale Solar, 2023 Edition: Analysis of Empirical Plant-level Data from U.S. Ground-mounted PV, PV+battery, and CSP Plants (exceeding 5 MWAC)

Berkeley Labs "Utility-Scale Solar", 2023 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2022, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, and interconnection queue data.

analysis↗

Development of Low-Cost, Crack-Tolerant Metallization Using Screen Printing

One of the ways to reduce the cost of solar electricity to 3/kWh, thus reaching parity with fossil-fuel-based generation, is to reduce the degradation rate of solar modules and extend their lifetime well beyond 30 years. The extended module lifetime in turn can positively influence the financial model and the bankability of utility-scale PV projects. Today, the highest-riskpriority solar module degradation mechanism is what is known as hot spots, often induced by cell cracks. In order to address this degradation mechanism, we make use of low-cost, multi-walled carbon nanotubes embedded in commercial screen-printable silver pastes. When the carbon nanotubes are properly functionalized and appropriately incorporated into commercial silver pastes, the resulting metal contacts on solar cells, after screen-printing and firing, show exceptional fracture toughness. These composite metal contacts possess increased ductility, electrical gap-bridging capability up to 50 um, and 'self-healing' to regain electrical continuity even after cycles of complete electrical failure under extreme strain.

14 SOLAR ENERGY↗

Deployable aerospace PV array based on amorphous silicon alloys

The development of the first commercial, ultralight, flexible, deployable, PV array for aerospace applications is discussed. It is based on thin-film, amorphous silicon alloy, multijunction, solar cells deposited on a thin metal or polymer by a proprietary, roll-to-roll process. The array generates over 200 W at AM0 and is made of 20 giant cells, each 54 cm x 29 cm (1566 sq cm in area). Each cell is protected with bypass diodes. Fully encapsulated array blanket and the deployment mechanism weigh about 800 and 500 g, respectively. These data yield power per area ratio of over 60 W/sq m specific power of over 250 W/kg (4 kg/kW) for the blanket and 154 W/kg (6.5 kg/kW) for the power system. When stowed, the array is rolled up to a diameter of 7 cm and a length of 1.11 m. It is deployed quickly to its full area of 2.92 m x 1.11 m, for instant power. Potential applications include power for lightweight space vehicles, high altitude balloons, remotely piloted and tethered vehicles. These developments signal the dawning of a new age of lightweight, deployable, low-cost space arrays in the range from tens to tens of thousands of watts for near-term applications and the feasibility of multi-100 kW to MW arrays for future needs.

Hanak, Joseph J.↗

Space Station Freedom advanced photovoltaics and battery technology development planning

Space Station Freedom (SSF) usable electrical power is planned to be built up incrementally during assembly phase to a peak of 75 kW end-of-life (EOL) shortly after Permanently Manned Capability (PMC) is achieved in 1999. This power will be provided by planar silicon (Si) arrays and nickel-hydrogen (NiH2) batteries. The need for power is expected to grow from 75 kW to as much as 150 kW EOL during the evolutionary phase of SSF, with initial increases beginning as early as 2002. Providing this additional power with current technology may not be as cost effective as using advanced technology arrays and batteries expected to develop prior to this evolutionary phase. A six-month study sponsored by NASA Langley Research Center and conducted by Boeing Defense and Space Group was initiated in Aug. 1991. The purpose of the study was to prepare technology development plans for cost effective advanced photovoltaic (PV) and battery technologies with application to SSF growth, SSF upgrade after its arrays and batteries reach the end of their design lives, and other low Earth orbit (LEO) platforms. Study scope was limited to information available in the literature, informal industry contacts, and key representatives from NASA and Boeing involved in PV and battery research and development. Ten battery and 32 PV technologies were examined and their performance estimated for SSF application. Promising technologies were identified based on performance and development risk. Rough order of magnitude cost estimates were prepared for development, fabrication, launch, and operation. Roadmaps were generated describing key issues and development paths for maturing these technologies with focus on SSF application.

Brender, Karen D.↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

Recent Space PV Concentrator Advances: More Robust, Lighter, and Easier to Track

Over the past three years, the authors have collaborated on several significant advances in space photovoltaic concentrator technology, including a far more robust Fresnel lens for sunlight concentration, improved color-mixing features for the lens to minimize chromatic aberration losses for next-generation 4-junction and 6-junction IMM cells, a new approach to suntracking requiring only one axis of rotation even in the presence of large beta angles (e.g., +/- 50 deg), a new waste heat radiator made of graphene, with 80-90% reduction in mass, and a new platform for deployment and support on orbit (SOLAROSA). These patent-pending advances are described in this paper.

concentrators↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Utility-Scale Solar, 2024 Edition: Analysis of Empirical Plant-level Data from U.S. Ground-mounted PV, PV+battery, and CSP Plants (exceeding 5 MWAC)

Berkeley Labs "Utility-Scale Solar", 2024 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2023, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, net value, and interconnection queue data.

analysis↗

Global Techno-Economic Performance of Bifacial and Tracking Photovoltaic Systems

Although most of the current photovoltaic (PV) system installations use monofacial modules with fixed-tilt mounting structures, bifacial modules, trackers, and the combination of them are also getting more attention as potential candidates to further reduce the PV levelized cost of electricity (LCOE). This work is then the first to present a worldwide analysis on the yield potential and cost-effectiveness of PV farms composed of monofacial fixed-tilt and single/dual (1T/2T) tracker installations, as well as their bifacial counterparts. Our approach starts by estimating the irradiance reaching the front and rear surface of the modules for the different system designs (validated based on data from real PV systems and results from the literature) to estimate their energy production (row-row shading is neglected). Subsequently, the overall system cost during their 25-year lifetime is factored in, and LCOE is obtained. The results reveal that bifacial-1T installations increase energy yield by 35% and reach the lowest LCOE for the majority of the world (93.1% of the land area). Although dual axis trackers achieve the highest energy generation — especially for bifacial modules — their cost is still too high, and are therefore not as cost-effective. Sensitivity analyses based on the Monte Carlo and region sensitivity approach are performed to analyze the impact of input assumptions on the calculated LCOE. These reveal that our conclusions are robust in general but exact configuration to choose depends on specific site conditions. This investigation is not only of interest to the scientific community, but also can be used as a guide for PV installation companies and investors to determine the most suitable technology for a particular location.

14 SOLAR ENERGY↗

Utility-Scale Solar, 2022 Edition: Analysis of Empirical Plant-level Data from U.S. Ground-mounted PV, PV+battery, and CSP Plants (exceeding 5 MWAC)

Berkeley Labs "Utility-Scale Solar", 2022 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2021, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, and interconnection queue data.

2022↗

AI-Based EMT Dynamic Model of PV Systems

Several electromagnetic transient (EMT) dynamic modeling methods are available to model systems like photovoltaic (PV) plants, wind power plants, variable-speed drives, among others. The methods include: (a) physics-based models and (b) data-driven models. The physics-based dynamic models may include high-fidelity switched system model and average-value model that both require the control algorithms included in the models. However, manufacturers typically prefer to provide black-box models to avoid disclosing proprietary. One of the solutions to prevent disclosing control algorithms is the use of data-driven dynamic EMT models of PV systems. In this paper, data-driven dynamic EMT model based on artificial intelligence (AI) algorithms are presented. The AI algorithms evaluated include convolutional neural networks, recurrent neural networks, and nonlinear auto-regressive exogenous model. Automation in generating data and training these models is also discussed in this paper. The results generated by the best AI algorithms have been observed to be greater than 95 % accurate.