Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Atomic and ionic hydrogen flux probe for quantitative in-situ monitoring of hydrogen recycling

A new combination diagnostic as a hydrogen recycling monitor in harsh conditions is proposed. Combining permeation membrane probe with a Langmuir probe provides a possibility to measure both atomic and ionic hydrogen fluxes to plasma facing components. A brief overview of permeation probes is given. The range of measurable H fluxes is from 10 16 to more than 10 20 H m –2 s –1 . Time response of the permeation probe is ~ 0.1–0.5 s. A method to address disadvantages of permeation probes is proposed. This includes an introduction of a preparation chamber for Ar-plasma cleaning of the membrane and absolute calibration with a visible spectroscopy. The hydrogen recombination coefficient, evaluated in such calibration, is k u = 5.9 × 10 –30 m 4 s –1 , which agrees well with previous research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transport of tungsten to collector probes in DIII-D

Collector probes have long been used to measure impurity fluxes in the scrape off layer (SOL) of tokamaks. In this study, collector probes were inserted in the main SOL of DIII-D during the tungsten Metal Rings Campaign, and the W deposits on the probes were analyzed ex situ using Rutherford backscattering spectrometry analysis to obtain radial profiles of W deposition. A simple picture is hypothesized for how the W transports through the SOL from the target to the two sides of the probe, based on a long-theorized impurity accumulation at the crown (i.e. the top) of the plasma. The patterns observed in the deposition profiles along the probes support the hypothesized picture; however, 3D modeling and further experimental studies are needed to support more definitive conclusions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Patterned probes for high precision 4D-STEM bragg measurements

Nanoscale strain mapping by four-dimensional scanning transmission electron microscopy (4D-STEM) relies on determining the precise locations of Bragg-scattered electrons in a sequence of diffraction patterns, a task which is complicated by dynamical scattering, inelastic scattering, and shot noise. These features hinder accurate automated computational detection and position measurement of the diffracted disks, limiting the precision of measurements of local deformation. Here, we investigate the use of patterned probes to improve the precision of strain mapping. We imprint a "bullseye" pattern onto the probe, by using a binary mask in the probe-forming aperture, to improve the robustness of the peak finding algorithm to intensity modulations inside the diffracted disks. We show that this imprinting leads to substantially improved strain-mapping precision at the expense of a slight decrease in spatial resolution. In experiments on an unstrained silicon reference sample, we observe an improvement in strain measurement precision from 2.7% of the reciprocal lattice vectors with standard probes to 0.3% using bullseye probes for a thin sample, and an improvement from 4.7% to 0.8% for a thick sample. Additionally, we use multislice simulations to explore how sample thickness and electron dose limit the attainable accuracy and precision for 4D-STEM strain measurements.

47 OTHER INSTRUMENTATION↗

Direct Surface and Droplet Microsampling for Electrospray Ionization Mass Spectrometry Analysis with an Integrated Dual-Probe Microfluidic Chip

Ambient mass spectrometry (MS) has revolutionized the way of MS analysis and broadened its application in various fields. This paper describes the use of microfluidic techniques to simplify the setup and improve the functions of ambient MS by integrating the sampling probe, electrospray emitter probe, and online mixer on a single glass microchip. Two types of sampling probes, including a parallel-channel probe and a U-shaped channel probe, were designed for dryspot and liquid-phase droplet samples, respectively. We demonstrated that the microfabrication techniques not only enhanced the capability of ambient MS methods in analysis of dry-spot samples on various surfaces, but also enabled new applications in the analysis of nanoliter-scale chemical reactions in an array of droplets. The versatility of the microchip-based ambient MS method was demonstrated in multiple different applications including evaluation of residual pesticide on fruit surfaces, sensitive analysis of low-ionizable analytes using postsampling derivatization, and high-throughput screening of Ugi-type multicomponent reactions.

Huang, Cong-Min↗

X-ray and Optical Circular Dichroism as Local and Global Ultrafast Chiral Probes of [12]Helicene Racemization

Optical circular dichroism (OCD) is a well-established technique for probing molecular chirality typically in the UV-visible window. Although molecular chirality is usually related to a chiral center, it can alternatively describe a global structure. The electronic transitions are then delocalized and OCD is said to probe the global chirality. Recent advances controlling the polarization and spatial structure of X-ray beams have led to novel spectroscopic techniques such as X-ray circular dichroism (XCD), which can exploit the localized nature of the X-ray electronic transitions. XCD is thus sensitive to local structures and the relevant chirality probed with it can be referred as local. Here, we use the racemization mechanism of the [12]Helicene as a model to assess the capabilities of OCD and XCD as probes of global and local chiralities. In conclusion, our simulations suggest that XCD is a reliable spectroscopic technique for probing the local chirality of molecules, suggesting the further development of this experimental technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing many-body dynamics in a two-dimensional dipolar spin ensemble

Abstract The most direct approach for characterizing the quantum dynamics of a strongly interacting system is to measure the time evolution of its full many-body state. Despite the conceptual simplicity of this approach, it quickly becomes intractable as the system size grows. An alternate approach is to think of the many-body dynamics as generating noise, which can be measured by the decoherence of a probe qubit. Here we investigate what the decoherence dynamics of such a probe tells us about the many-body system. In particular, we utilize optically addressable probe spins to experimentally characterize both static and dynamical properties of strongly interacting magnetic dipoles. Our experimental platform consists of two types of spin defects in nitrogen delta-doped diamond: nitrogen-vacancy colour centres, which we use as probe spins, and a many-body ensemble of substitutional nitrogen impurities. We demonstrate that the many-body system’s dimensionality, dynamics and disorder are naturally encoded in the probe spins’ decoherence profile. Furthermore, we obtain direct control over the spectral properties of the many-body system, with potential applications in quantum sensing and simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel femtosecond-gated, high-resolution, frequency-shifted shearing interferometry technique for probing pre-plasma expansion in ultra-intense laser experiments

Ultra-intense laser-matter interaction experiments (>10{sup 18} W/cm{sup 2}) with dense targets are highly sensitive to the effect of laser “noise” (in the form of pre-pulses) preceding the main ultra-intense pulse. These system-dependent pre-pulses in the nanosecond and/or picosecond regimes are often intense enough to modify the target significantly by ionizing and forming a plasma layer in front of the target before the arrival of the main pulse. Time resolved interferometry offers a robust way to characterize the expanding plasma during this period. We have developed a novel pump-probe interferometry system for an ultra-intense laser experiment that uses two short-pulse amplifiers synchronized by one ultra-fast seed oscillator to achieve 40-fs time resolution over hundreds of nanoseconds, using a variable delay line and other techniques. The first of these amplifiers acts as the pump and delivers maximal energy to the interaction region. The second amplifier is frequency shifted and then frequency doubled to generate the femtosecond probe pulse. After passing through the laser-target interaction region, the probe pulse is split and recombined in a laterally sheared Michelson interferometer. Importantly, the frequency shift in the probe allows strong plasma self-emission at the second harmonic of the pump to be filtered out, allowing plasma expansion near the critical surface and elsewhere to be clearly visible in the interferograms. To aid in the reconstruction of phase dependent imagery from fringe shifts, three separate 120° phase-shifted (temporally sheared) interferograms are acquired for each probe delay. Three-phase reconstructions of the electron densities are then inferred by Abel inversion. This interferometric system delivers precise measurements of pre-plasma expansion that can identify the condition of the target at the moment that the ultra-intense pulse arrives. Such measurements are indispensable for correlating laser pre-pulse measurements with instantaneous plasma profiles and for enabling realistic Particle-in-Cell simulations of the ultra-intense laser-matter interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The phase transition in VO 2 probed using x-ray, visible and infrared radiations

Vanadium dioxide (VO 2 ) is a model system that has been used to understand closely occurring multiband electronic (Mott) and structural (Peierls) transitions for over half a century due to continued scientific and technological interests. Among the many techniques used to study VO 2 , the most frequently used involve electromagnetic radiation as a probe. Understanding of the distinct physical information provided by different probing radiations is incomplete, mostly owing to the complicated nature of the phase transitions. Here, we use transmission of spatially averaged infrared (λ = 1.5 μm) and visible (λ = 500 nm) radiations followed by spectroscopy and nanoscale imaging using x-rays (λ = 2.25–2.38 nm) to probe the same VO 2 sample while controlling the ambient temperature across its hysteretic phase transitions and monitoring its electrical resistance. We directly observed nanoscale puddles of distinct electronic and structural compositions during the transition. The two main results are that, during both heating and cooling, the transition of infrared and visible transmission occurs at significantly lower temperatures than the Mott transition, and the electronic (Mott) transition occurs before the structural (Peierls) transition in temperature. We use our data to provide insights into possible microphysical origins of the different transition characteristics. We highlight that it is important to understand these effects because small changes in the nature of the probe can yield quantitatively, and even qualitatively, different results when applied to a non-trivial multiband phase transition. Our results guide more judicious use of probe type and interpretation of the resulting data.

36 MATERIALS SCIENCE↗

Coherence specific signal detection via chiral pump-probe spectroscopy

We examine transient circular dichroism (TRCD) spectroscopy as a technique to investigate signatures of exciton coherence dynamics under the influence of structured vibrational environments. We consider a pump-probe configuration with a linearly polarized pump and a circularly polarized probe, with a variable angle θ between the two directions of propagation. In our theoretical formalism the signal is decomposed in chiral and achiral doorway and window functions. Using this formalism, we show that the chiral doorway component, which beats during the population time, can be isolated by comparing signals with different values of θ. As in the majority of time-resolved pump-probe spectroscopy, the overall TRCD response shows signatures of both excited and ground state dynamics. However, we demonstrate that the chiral doorway function has only a weak ground state contribution, which can generally be neglected if an impulsive pump pulse is used. These findings suggest that the pump-probe configuration of optical TRCD in the impulsive limit has the potential to unambiguously probe quantum coherence beating in the excited state. We present numerical results for theoretical signals in an example dimer system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A multi-channel capacitive probe for electrostatic fluctuation measurement in the Madison Symmetric Torus reversed field pinch

A 40-channel capacitive probe has been developed to measure the electrostatic fluctuations associated with the tearing modes deep into Madison Symmetric Torus (MST) reversed field pinch plasma. The capacitive probe measures the ac component of the plasma potential via the voltage induced on stainless steel electrodes capacitively coupled with the plasma through a thin annular layer of boron nitride (BN) dielectric (also serves as the particle shield). When bombarded by the plasma electrons, BN provides a sufficiently large secondary electron emission for the induced voltage to be very close to the plasma potential. The probe consists of four stalks each with ten cylindrical capacitors that are radially separated by 1.5 cm. The four stalks are arranged on a 1.3 cm square grid so that at each radial position, there are four electrodes forming a square grid. Every two adjacent radial sets of four electrodes form a cube. The fluctuating electric field can be calculated by the gradient of the plasma potential fluctuations at the eight corners of the cube. The probe can be inserted up to 15 cm (r/a = 0.7) into the plasma. Furthermore, the capacitive probe has a frequency bandwidth from 13 Hz to 100 kHz, amplifier-circuit limit, sufficient for studying the tearing modes (5-30 kHz) in the MST reversed-field pinch.

47 OTHER INSTRUMENTATION↗

Plasma density perturbation caused by probes at low gas pressure

An analysis of plasma parameter perturbations caused by a spherical probe immersed into a spherical plasma is presented in this paper for arbitrary collisionality and arbitrary ratios of probe to plasma dimensions. The plasma was modeled by the fluid plasma equations with ion inertia and nonlinear ion friction force that dominate plasma transport at low gas pressures. Significant depletion of the plasma density around the probe surface has been found. The area of plasma depletion coincides with the sensing area of different kinds of magnetic and microwave probes and will therefore lead to errors in data inferred from measurements with such probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature Sensitivity Study of Eddy Current and Digital Gauge Probes for Nuclear Fuel Rod Oxide Measurement

Temperature Sensitivity Study of Eddy Current and Digital Gauge Probes for Nuclear Fuel Rod Oxide Measurement Faith R. Beck, Department of Mechanical Engineering, Penn State University, State College, PA R. Paul Lind and James A. Smith, Idaho National Laboratory, Idaho Falls, ID Novel fuels are part of the nationwide effort to reduce the enrichment of Uranium for energy production. Performance of such fuels is determined by irradiating their surfaces. To test irradiated samples, the machinery must operate remotely. The plate checker used in this experiment at Idaho National Lab (INL) performs non-destructive testing on fuel rod and plate geometries with two different types of sensors: eddy current and digital thickness gauges. The sensors measure oxide growth and total sample thickness on research fuels, respectively. Sensor measurement accuracy is crucial because even 10 microns of error is significant when determining the viability of an experimental fuel. One parameter known to affect the eddy current and thickness gauge sensors is temperature. Since both sensor accuracies depend on the ambient temperature of the system, the plate checker has been characterized for these sensitivities. The eddy current probes were tested previously in a non-radioactive environment and are noted to have sensitivity to temperature. The manufacturer of the digital gauge probes has noted a rather large coefficient of thermal expansion for their linear scale. It should also be noted that the accuracy of the digital gauge probes are specified at 20°C, which is approximately 7°C cooler than the average hot-cell temperature. In this work, the effect of temperature on the eddy current and digital gauge probes is studied, and thickness measurements are given as empirical functions of temperature. Acknowledgement: This work was supported by the INL and the DOE office of NNSA (National Nuclear Safety Administration).

36 MATERIALS SCIENCE↗

A new B-dot probe circuit for magnetic diagnostics of radio frequency discharges

Accurate magnetic measurements in radio frequency capacitively coupled plasmas (CCP) are challenging due to the presence of inherently strong electric fields and relatively weak magnetic fields. In this work, a new B-dot probe circuit is presented, comprising two variable capacitors in a tunable series resonance circuit, with a center-tapped, step-up transformer. The output characteristics of the probe are predicted using two distinct equivalent circuit models, one for the differential mode and the other for the common mode. A Helmholtz coil and a Faraday cup are used for experimental validation of the predicted probe output. By tuning the two variable capacitors in the circuit, the magnetic probe can achieve improved signal-to-noise ratio by amplifying the inductive signal, while suppressing capacitive coupling interference. Finally, using the newly designed probe, magnetic measurements in typical CCP are presented.

47 OTHER INSTRUMENTATION↗

Driven probe particle dynamics in a bubble and pattern forming system

We numerically examine the dynamics of a probe particle driven at a constant force through an assembly of particles with competing long-range repulsion and short-range attraction that forms a bubble or stripe state. In the bubble regime, we identify several distinct types of motion, including an elastic or pinned regime where the probe particle remains inside a bubble and drags all other bubbles with it. There is also a plastic bubble phase where the bubble in which the probe particle is trapped is able to move past the adjacent bubbles. At larger drives, there is a breakthrough regime where the probe particle jumps from bubble to bubble and, in some cases, can induce correlated rotations or plastic rearrangements of the particles within the bubbles. At the highest drives, the probe particle moves sufficiently rapidly that the background particles undergo only small distortions. The distinctive dynamic flow states and the transitions between them are accompanied by signatures in the effective drag on the driven particle, jumps in the velocity–force curves, and changes in the time-dependent velocity fluctuations. We map the dynamic phase diagram for this system for varied interaction lengths, bubble sizes, and densities.

36 MATERIALS SCIENCE↗

A tetrahedral probe constellation approach for measuring canonical momentum in self-organized laboratory plasma

To examine momentum redistribution processes and study generalized helicities during plasma relaxation in Madison Symmetric Torus, MST, reversed field pinch plasma, a new probe is being tested to measure the full 3D plasma ion flow and magnetic field vectors at four spatial locations arranged in a tetrahedral shape reminiscent of a satellite measurement constellation. These measurements permit calculation of ∇ x $\vec{u}$ and canonical momentum, where $\vec{u}$ is the plasma ion flow vector. The probe consists of four probe heads arranged in a tetrahedral pattern, with an overall probe diameter of ∼31.75 mm. The probe head diameter is ∼1.0 cm, which is of the order of the ion Larmor radius. Each head has four molybdenum electrodes, also arranged in tetrahedral geometry, which are biased relative to a common return electrode, using four power supplies (one for each head), to measure the local ion flow. Additionally, each head has three orthogonal magnetic pickup coils within it to measure equilibrium and fluctuating magnetic fields.

Physics - Plasma physics↗

Probing the galaxy–halo connection with total satellite luminosity

ABSTRACT We demonstrate how the total luminosity in satellite galaxies is a powerful probe of dark matter haloes around central galaxies. The method cross-correlates central galaxies in spectroscopic galaxy samples with fainter galaxies detected in photometric surveys. Using models, we show that the total galaxy luminosity, Lsat, scales linearly with host halo mass, making Lsat an excellent proxy for Mh. Lsat is also sensitive to the formation time of the halo. We demonstrate that probes of galaxy large-scale environment can break this degeneracy. Although this is an indirect probe of the halo, it yields a high signal-to-noise ratio measurement for galaxies expected to occupy haloes at <1012 M⊙, where other methods suffer from larger errors. In this paper, we focus on observational and theoretical systematics in the Lsat method. We test the robustness of our method of finding central galaxies and our methods of estimating the number of background galaxies. We implement this method on galaxies in the Sloan Digital Sky Survey (SDSS) data, with satellites identified in fainter imaging data. We find excellent agreement between our theoretical predictions and the observational measurements. Finally, we compare our Lsat measurements to weak lensing estimates of Mh for red and blue subsamples. In the stellar mass range where the measurements overlap, we find consistent results, where red galaxies live in larger haloes. However, the Lsat approach allows us to probe significantly lower mass galaxies. At these masses, the Lsat values are equivalent. This example shows the potential of Lsat as a probe of dark haloes.

79 ASTRONOMY AND ASTROPHYSICS↗

Magneto-optical spectroscopy based on pump-probe strobe light

Here, we demonstrate a pump-probe strobe light spectroscopy for sensitive detection of magneto-optical dynamics in the context of hybrid magnonics. The technique uses a combinatorial microwave-optical pump-probe scheme, leveraging both the high-energy resolution of microwaves and high-efficiency detection using optical photons. In contrast with conventional stroboscopy using continuous-wave light, we apply microwave and optical pulses with varying pulse widths, and demonstrate magneto-optical detection of magnetization dynamics in Y 3 Fe 5 O 12 films. The detected magneto-optical signals depend strongly on the characteristics of both the microwave and the optical pulses, as well as their relative time delays. We show that good magneto-optical sensitivity and coherent stroboscopic character are maintained, even at a microwave pump pulse of 1.5 ns and an optical probe pulse of 80 ps, under a 7 MHz clock rate, corresponding to a pump-probe footprint of approximately 1% in one detection cycle. Our results show that time-dependent strobe light measurement of magnetization dynamics can be achieved in the gigahertz frequency range under a pump-probe detection scheme.

36 MATERIALS SCIENCE↗

Scalable Proximity-Based Methods for Large-Scale Analysis of Atom Probe Data

Powered by recent advances in data acquisition technologies, today's state-of-the-art atom probe microscopes yield data sets with sizes ranging from a few million atoms to billions of atoms. Analysis of these atomic data sets within rea-sonable turnaround times is a pressing data analysis challenge for material scientists currently equipped with software systems that do not scale to these massive data sets. Here, we present the shared memory component of a larger ongoing effort to develop a multi-feature data analysis framework capable of analyzing atom probe data of all sizes and scales from desktop multicore machines to large-scale high-performance computing platforms with hybrid (shared and distributed memory) architectures. Our focus here is on a broad class of popular atom probe data analysis methods that rely on core time-consuming k-NN queries. We present a scalable, heuristic algorithm for k-NN queries using three-dimensional range trees. To demonstrate its efficacy, the k-NN algorithm is integrated with two use cases of atom probe data analysis methods and the resulting analysis times are shown to speedup by over 20X on a 32-core Cray XC40 node using workloads up to 8 million atoms, which is already beyond the at-scale capabilities of existing atom probe software. Using this k-NN algorithm, we also introduce a novel parameter estimation method for a class of cluster finding methods, called friends-of-friends (FoF) methods, to completely bypass their expensive pre-processing steps. In each case, we validate the results on a variety of control data sets.

Lu, Hao↗