Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Modification of Mach 6 Freestream Flow by Pitot Probe Bow Shock as Measured by Line FLDI and SAFS

Measurements of the flow in front of flat-face Pitot probes in NASA Langley ResearchCenter’s 20-Inch Mach 6 Air Tunnel were made using a 35-point line focused laser differentialinterferometer (FLDI), a two-point FLDI, and a self-aligned focusing schlieren system. Thesesystems were used to make measurements of flow unsteadiness between the bow shock andPitot probe face, while also probing the freestream region just upstream of the bow shock.Shock standoff distances from the non-intrusive measurements match closely with analyticalsolutions using the probe face diameter. Acoustic wave angles and velocities in the freestreamcompare favorably with DNS simulations of a Mach 6 freestream flow, and wave velocities in thepost-shock region slow as they approach the probe face. Peak frequencies in the post-shockregion as measured by FLDI compare favorably to the estimates computed from the shockstandoff distance for most probe diameters. With increasing unit Reynolds number, fluctuationintensities in the post-shock region were attenuated below the intensities of the freestream, witha spectral, spatial, and probe size dependence. Pitot probe power spectral density estimatesare presented from the test campaign, which can be compared with FLDI and SAFS data toevaluate the applicability of the transfer functions derived from computational simulations.

Joshua M Weisberger↗

A Multi‐Probe Automated Classification of Ice Crystal Habits During the IMPACTS Campaign

Although all ice crystals are unique, many can be grouped together by shape or habit, with members of a habit class sharing similar representations of properties such as fall velocity and growth rate. A decision tree algorithm designed to be adaptable to any particle imaging probe, thus enabling the creation of habit size distributions over a size range larger than that of any probe on its own, is used to classify ice crystals imaged by three airborne cloud probes in mid-latitude winter cyclones during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS) field campaign. Crystals are sorted into seven habit classes based on their morphological properties: sphere, column/needle, plate, graupel, dendrite, aggregate, and irregular. Although adaptability was its primary goal, the algorithm was found to be moderately skillful for identifying idealized habit images. Quantitative tests of the algorithm’s adaptability displayed mixed results, as Two-Dimensional Stereo Probe (2DS) classifications showed moderate correlation with Particle Habit Imaging and Polar Scattering Probe (PHIPS) classifications, but only weak correlation with High Volume Precipitation Spectrometer (HVPS) classifications. The algorithm was applied to random sets of images from each probe in a case study of a mesoscale snow band sampled on 7 February 2020. In the case study, qualitative analysis of particle images revealed general agreement on classifications among the probes, supporting the algorithm’s applicability to multiple cloud probes. Most classifications appeared correct upon manual inspection, suggesting that in practical use, the algorithm is reasonably able to classify non-idealized images.

Julian Schima↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

47 OTHER INSTRUMENTATION↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

47 OTHER INSTRUMENTATION↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

47 OTHER INSTRUMENTATION↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

Adams, Jesse D↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrostatic probe disruption of drift waves in magnetized microdischarges

Ultrahigh speed images of ExB discharges are collected during electrostatic probing of magnetized microdischarges. Two azimuthally separated floating micro-Langmuir probes inserted into an axisymmetric microscale magnetically confined plasma are used to characterize azimuthal drift waves. The images reveal features associated with probe intrusion, showing how the electrostatic probes may disrupt the otherwise coherent azimuthal waves. The resulting wave dispersion calculated from the probe signals is consistent with the disruptions seen in the images. These images demonstrate how probe measurements of fluctuations and turbulence, even when probe dimensions are much smaller than characteristic discharge scales, must be interpreted with caution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cross-scale observations of the 2015 St. Patrick's day storm: THEMIS, Van Allen Probes, and TWINS

In this paper, we present cross-scale magnetospheric observations of the 17 March 2015 (St. Patrick's Day) storm, by Time History of Events and Macroscale Interactions during Substorms (THEMIS), Van Allen Probes (Radiation Belt Storm Probes), and Two Wide-angle Imaging Neutral-atom Spectrometers (TWINS), plus upstream ACE/Wind solar wind data. THEMIS crossed the bow shock or magnetopause 22 times and observed the magnetospheric compression that initiated the storm. Empirical models reproduce these boundary locations within 0.7 R E . Van Allen Probes crossed the plasmapause 13 times; test particle simulations reproduce these encounters within 0.5 R E . Before the storm, Van Allen Probes measured quiet double-nose proton spectra in the region of corotating cold plasma. About 15 min after a 0605 UT dayside southward turning, Van Allen Probes captured the onset of inner magnetospheric convection, as a density decrease at the moving corotation-convection boundary (CCB) and a steep increase in ring current (RC) proton flux. During the first several hours of the storm, Van Allen Probes measured highly dynamic ion signatures (numerous injections and multiple spectral peaks). Sustained convection after ~1200 UT initiated a major buildup of the midnight-sector ring current (measured by RBSP A), with much weaker duskside fluxes (measured by RBSP B, THEMIS a and THEMIS d). A close conjunction of THEMIS d, RBSP A, and TWINS 1 at 1631 UT shows good three-way agreement in the shapes of two-peak spectra from the center of the partial RC. A midstorm injection, observed by Van Allen Probes and TWINS at 1740 UT, brought in fresh ions with lower average energies (leading to globally less energetic spectra in precipitating ions) but increased the total pressure. Finally, the cross-scale measurements of 17 March 2015 contain significant spatial, spectral, and temporal structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecular Surface Sampling and Chemical Imaging using Proximal Probe Thermal Desorption/Secondary Ionization Mass Spectrometry

Proximal probe thermal desorption/secondary ionization mass spectrometry was studied and applied to molecular surface sampling and chemical imaging using printed patterns on photopaper as test substrates. With the use of a circular cross section proximal probe with a tip diameter of 50 m and fixed temperature (350 C), the influence of probe-to-surface distance, lane scan spacing, and surface scan speed on signal quality and spatial resolution were studied and optimized. As a compromise between signal amplitude, signal reproducibility, and data acquisition time, a surface scan speed of 100 m/s, probe-to-paper surface distance of 5 m, and lane spacing of 10 m were used for imaging. Under those conditions the proximal probe thermal desorption/secondary ionization mass spectrometry method was able to achieve a spatial resolution of about 50 m as determined by the ability to distinguish surface patterns of known dimensions that were printed on the paper substrate. It is expected that spatial resolution and chemical image quality could be further improved by using probes of smaller cross section size and by incorporating a means to maintain a fixed optimal probe-to-surface distance real time, continuously adapting to the changing topography of the surface during a lane scan.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emerging Electrochemical Techniques for Probing Site Behavior in Single-Atom Electrocatalysts

Single-atom catalysts (SACs) have aroused tremendous interest over the past decade, particularly in the community of energy and environment-related electrocatalysis. A rapidly growing number of recent publications have recognized it as a promising candidate with maximum atomic utilization, distinct activity, and selectivity in comparison to bulk catalysts and nanocatalysts. However, the complexity of localized coordination environments and the dispersion of isolated sites lead to significant difficulties when it comes to gaining insight into the intrinsic behavior of electrocatalytic reactions. Furthermore, the low metal loadings of most SACs make conventional ensemble measurements less likely to be accurate on the subnanoscale. Thus, it remains challenging to probe the activity and properties of individual atomic sites by available commercial instruments and analytical methods. In spite of this, continuing efforts have lately focused on the development of advanced measurement methodologies, which are very useful to the fundamental understanding of SACs. There have recently been a number of in situ/operando techniques applied to SACs, such as electron microscopy, spectroscopy, and other analysis methods, which support relevant functions to identify the active sites and reaction intermediates and to investigate the dynamic behavior of localized structures of the catalytic sites. This Account aims to present recent electrochemical probing techniques which can be used to identify single-atomic catalytic sites within solid supports. First, we describe the basic principles of molecular probe methods for the study and analysis of electrocatalytic site behavior. In particular, the in situ probing technique enabled by surface interrogation scanning electrochemical microscopy (SISECM) can measure the active site density and kinetic rate with high resolution. An alternative electrochemical probing technique is further demonstrated on the basis of single-entity electrochemistry, which allows the unique electrochemical imaging of the size and catalytic rate of single atoms, molecules, and clusters. Next, the merits and limitations of different electrochemical techniques are then discussed, along with perspectives for future prospects. Apart from this, we further showcase the powerful capability of emerging electrochemical probing techniques for determining significant effects and properties of SACs for various electrocatalytic reactions, including oxygen reduction and evolution, hydrogen evolution, and nitrate reduction. Overall, electrochemical techniques with atomic resolution have greatly increased opportunities for observing, measuring, and understanding the surface and interface chemistry during energy conversion. In the future, it is anticipated that the development of electrochemical probing techniques will be advanced with innovative perspectives on the behavior and features of SACs. We hope that this Account can contribute in several ways to promoting the fundamental knowledge and technical progress of emerging electrochemical measurements for studying SACs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Cation–$π$ Interaction Enables a Halo-Tag Fluorogenic Probe for Fast No-Wash Live Cell Imaging and Gel-Free Protein Quantification

The design of fluorogenic probes for a Halo tag is highly desirable but challenging. Previous work achieved this goal by controlling the chemical switch of spirolactones upon the covalent conjugation between the Halo tag and probes or by incorporating a “channel dye” into the substrate binding tunnel of the Halo tag. In this work, we have developed a novel class of Halo-tag fluorogenic probes that are derived from solvatochromic fluorophores. The optimal probe, harboring a benzothiadiazole scaffold, exhibits a 1000-fold fluorescence enhancement upon reaction with the Halo tag. Structural, computational, and biochemical studies reveal that the benzene ring of a tryptophan residue engages in a cation–$π$ interaction with the dimethylamino electron-donating group of the benzothiadiazole fluorophore in its excited state. We further demonstrate using noncanonical fluorinated tryptophan that the cation–$π$ interaction directly contributes to the fluorogenicity of the benzothiadiazole fluorophore. Mechanistically, this interaction could contribute to the fluorogenicity by promoting the excited-state charge separation and inhibiting the twisting motion of the dimethylamino group, both leading to an enhanced fluorogenicity. Finally, we demonstrate the utility of the probe in no-wash direct imaging of Halo-tagged proteins in live cells. In addition, the fluorogenic nature of the probe enables a gel-free quantification of fusion proteins expressed in mammalian cells, an application that was not possible with previously nonfluorogenic Halo-tag probes. The unique mechanism revealed by this work suggests that incorporation of an excited-state cation–$π$ interaction could be a feasible strategy for enhancing the optical performance of fluorophores and fluorogenic sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic Probe Molecule Selection Using Quantum Theory, First-Principles Calculations, and Machine Learning

Probe molecule vibrational spectra have a long history of being used to characterize materials including metals, oxides, metal-organic frameworks, and even human proteins. Furthermore, recent advances in machine learning have enabled computationally generated spectra to aid in detailed characterization of complex surfaces with probe molecules. Despite widespread use of probe molecules, the science of probe molecule selection is underdeveloped. Here, we develop physical concepts, including orbital interaction energy and the energy overlap integral, to explain and predict the ability of probe molecules to discriminate structural descriptors. We resolve the crystal orbital overlap population (COOP) to specific molecular orbitals and quantify their bonding character, which directly influences vibrational frequencies. Using only a single adsorbate calculation from density function theory (DFT), we compute the interaction energy of individual adsorbate molecular orbitals with adsorption site atomic orbitals across many different sites. Combining the molecular orbital resolved COOP and changes in orbital interaction energy enables probe molecule selection for improved discrimination of various sites. We demonstrate these concepts by comparing the predicted effectiveness of carbon monoxide (CO), nitric oxide (NO), and ethylene (C 2 H 4 ) to probe Pt adsorption sites. Finally, using a previously developed machine learning framework, we show that models trained on hundreds of thousand C 2 H 4 spectra, computed from DFT, which regress surface binding-type and generalized coordination number (GCN), outperform those trained using CO and NO spectra. Lastly, a python package, pDOS_overlap, for implementing the electron density based analysis on any combination of adsorbates and materials, is also made available.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development and testing of a novel micro-Raman probe and application of calibration transfer method for the quantitative analysis of microfluidic nitric acid streams

To simplify and improve the safety of reprocessing used nuclear fuel, an initial assessment was made of Raman microscopy applied to microfluidic volumes with a view toward the on-line spectroscopic measurement of highly radioactive solutions. This study compares a microscopic Raman probe (excitation focal point diameter 70 µm) to a larger, well studied probe (excitation focal point diameter 125 µm) used in prior investigations. This was done by chemometrically modeling and predicting concentrations of HNO3 solutions (0 M to 8 M) as they flowed through microfluidic cells based upon spectra from each probe. Spectra recorded for each probe using the same static HNO3 solution set contained in 2 dram glass vials were used as training sets to produce models for the respective probes. Modeling required baseline, normalization and smoothing preprocessing to compensate for a reduced path length between the static glass vial training set (4 cm) and the reduced path length flow cell (1 cm), wide ranging solution concentrations, and the associated non-linear spectral changes, and abrupt and uneven concentration changes of flowing solutions. The micro-Raman probe is able to produce spectra that may be analyzed chemometrically to accurately predict the concentration of flowing HNO3 solutions down to microliter volumes. Based upon RMSECV and RMSEP modeling statistics concentration predictions of the micro-Raman probe are comparable to those obtained for a macro-Raman on identical samples.

microscopic Raman probe, MicroRaman, nitric acid, ↗

High heat flux Langmuir probe array for the DIII-D divertor plates

Two modular arrays of Langmuir probes designed to handle a heat flux of up to 25 MW/m{sup 2} for 10 s exposures have been installed in the lower divertor target plates of the DIII-D tokamak. The 20 pyrolytic graphite probe tips have more than three times higher thermal conductivity and 16 times larger mass than the original DIII-D isotropic graphite probes. The probe tips have a fixed 12.5 deg. surface angle to distribute the heat flux more uniformly than the previous 6 mm diameter domed collectors and a symmetric 'rooftop' design to allow operation with reversed toroidal magnetic field. A large spring-loaded contact area improves heat conduction from each probe tip through a ceramic insulator into a cooled graphite divertor floor tile. The probe tips, brazed to molybdenum foil to ensure good electrical contact, are mounted in a ceramic tray for electrical isolation and reliable cable connections. The new probes are located 1.5 cm radially apart in a staggered arrangement near the entrance to the lower divertor pumping baffle and are linearly spaced 3 cm apart on the shelf above the in-vessel cryopump. Typical target plate profiles of J{sub sat}, T{sub e}, and V{sub f} with 4 mm spatial resolution are shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic field probes for use in radio frequency plasma

An impedance analyzer has been used in the characterization of a magnetic induction probe (B-dot probe) for use in plasma. The role of the impedance analyzer was to determine the frequency response of a B-dot probe up to 100 MHz. The probe was specifically designed to take measurements in rf plasma driven at 13.56 MHz. Probe sensitivity and calibration are considered based on the impedance values obtained when a B-dot probe is swept over a wide frequency range. Effects such as unbalanced loads based on transmission line inductances and termination impedance are shown to be limiting factors on the probes useful frequency range. The use of an impedance analyzer allows these effects to readily be characterized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metastable helium density probe for remote plasmas

Helium metastable atom density was spatially determined by a modified electrostatic probe in a remote plasma. The probe structure was similar to that of a guard ring probe. Opposite polarity voltages were applied to the inner probe and the guard ring to shield both electrons and ions from the vicinity of the inner probe. Therefore, the inner probe current is due to secondary electrons generated by the de-exciting helium metastable atom flux. The photoelectron current was removed by shielding and orienting the probe 90 deg. to the direction of the plasma-generated photon flux. Helium metastable atom density on the order of 10{sup 7} cm{sup -3} was measured. Limitations on the use of this technique are revealed by comparisons with simulated metastable distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗