Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA DIAGNOSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Modeling And Measurements Of The Demixing Effect In Arc Plasmas Containing Hydrogen

In this work are presented the results of the measurements of the plasma parameters in the wall-stabilized arc working in several mixtures of argon, hydrogen and sometimes helium, showing the lateral and longitudinal demixing effect. Lateral demixing in Ar+H{sub 2} is compared with the theoretical calculations of the plasma temperatures and molar ratios for Ar+H{sub 2} mixture, and its agreement with even the very simplified model of diffusion in arc plasma. The experiment shows the considerable lateral variations in the hydrogen percentage in the plasmas containing helium and, as well, the visible variations in electron density in such case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a Filtered High Current Pulsed Cathodic Vacuum Arc Plasma Source: Plasma Transport Analysis

Studies of plasma behavior produced by a filtered high current pulsed cathodic vacuum arc system are reported. Titanium plasma is initiated from the cathode by surface flash over triggering at the centre of the cathode disk. The multiple arc spots move outwards due to their mutual repulsion and the arc current pulse is terminated as the arc spots reach the edge of the cathode disk. The plasma moves into a positively biased quarter-torus magnetic filter and is guided towards the substrate position located 150 mm beyond the filter exit. Electron density and plasma current measurements have been employed to analyze the transport of the plasma associated with different cathode currents, and its dependence on confining magnetic field and bias conditions. For a given cathode current, the optimum plasma transport to the substrate requires the right combination of the strength of the confining magnetic field and the magnetic filter positive bias. The optimum values of these two parameters were found to increase with increasing cathode current. Initially the optimum throughput of plasma increases more strongly than the arc current (roughly 1.5 times the increase in the current); however, at high cathode current regimes (2.4 kA) a significant change of the plasma behavior is seen and transport efficiency is reduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of Xenon Plasma Streams Generated by Magnetoplasma Compressor

The paper presents the investigations of parameters of xenon plasma streams generated by magnetoplasma compressor (MPC) of compact geometry with conical-shaped electrodes and pulsed gas supply. Discharge characteristics and dynamics of the plasma streams, generated by MPC in different operation modes are analyzed. First results of Xe plasma radiation measurements in EUV wave range, obtained with AXUV diodes are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast-Neutron Source Based on Plasma-Focus Device

This paper describes investigations of neutrons produced by small plasma focus device PF-6 operating in the Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland. Main parameters of neutron radiation have been measured by scintillation probe, and by activation technique. Current derivative probe has also been applied to measure dI/dt signal. Simultaneously neutron transport calculations have been carried out by Monte Carlo method. Finally, experimental measurements and numerical calculations have allowed concluding that plasma focus devices can be useful pulse neutron sources for different applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Activation Technique and MCNP Calculations for Measurement of Fast Neutron Spatial Distribution at the MJ Plasma Focus Device

In this paper Plasma-Focus (PF) neutron emission properties have been studied using Monte Carlo calculations for neutron and photon transport. A Thermal Neutron Scaling Factor as a function of angular position of silver activation detectors placed around MJ Plasma Focus (PF-1000) device has been calculated. Detector responses calculated for 2.5 MeV neutrons and neutrons produced by Am-Be calibration source have been obtained .The results have shown the detector response dependence on the kind of calibration neutron source and on local geometrical/structural characteristics of the PF-1000 devices. Thus the proper calibration procedure ought to be performed for correct measurement of neutron yield within Plasma-Focus devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation Of Plasma Discharges Within Maja-PF Device Operated With Tungsten Inserts In The Central Electrode

The paper presents results of recent experimental studies with a MAJA-PF plasma-focus facility, as carried out for two different configurations of the end-plate of the central electrode. The main aim was to investigate an influence of the shape and material of the electrode end-plate on the formation and structure of the plasma column as well as to record and identify spectral lines of tungsten. The first version of the end-plate was made of Cu, while the second one had an insert made of a Cu-W alloy. Optical spectra were recorded by means of a Mechelle 900 spectrometer, operated with some delay in relation to a current peculiarity and with exposition times varied from 200 ns to 10 {mu}s. For shots with the Cu electrode spectral lines of deuterium (working gas) and carbon ions were recorded, but tungsten lines were not identified. It was estimated that the electron concentration changed from (8 divide 10)x10{sup 17} cm{sup -3} to about 2x10{sup 17} cm{sup -3} in 5 {mu}s after the current dip. In experiments with the second electrode version, among numerous spectral lines there were identified distinct WI and WII lines. Estimates of the tungsten ion concentration were impossible because of close positions of other lines. Diagrams of changes in the electron density are of importance for applications of DPM streams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of Edge Transport Barrier relaxations using Resonant Magnetic Perturbations

In divertor tokamak plasmas, an Edge Transport Barrier forms during the L-H transition. A poloidal shear flow has been shown to play a crucial role in the barrier sustainement. The H regime, obtained for a critical value of the heating power, is promising for the next generation of tokamak experiments such as ITER. However, an instability known as Edge Localized Mode (ELM) develops as the power is increased further. ELMs are characterized by intermittent bursts in the radial heat flux, therefore causing the transport barrier to relax quasi-periodically. Over the last decade, the possibility of controlling ELMs has become more and more plausible, as recent experiments were carried out on DIII-D using I-coils, on JET using error field correction coils, and on TEXTOR using an ergodic divertor. These experimental studies demonstrate a qualitative control over the ELMs by imposing a magnetostatic perturbation at the plasma edge. However, in order to get any quantitative result, much work has to be done in the understanding of ELM dynamics. In this work, we present results from numerical simulations of Resistive Ballooning Mode (RBM) turbulence reproducing the stabilization of barrier relaxations by a static magnetic perturbation. We focus our study on the edge region around the resonant surface q = 3. We use the TEXTOR tokamak geometry, and plasma parameters close to those used in typical experiments on this machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies of Pulsed Plasma-Ion Streams During Their Free Propagation And Interaction With Carbon-Tungsten Targets In PF-1000 Facility

The paper presents results of recent experimental studies within the PF-1000 plasma-focus facility [1], which were performed during the free propagation of pulsed plasma-ion streams inside the vacuum chamber, and during their interaction with different targets. Optical spectra were recorder by means of a Mechelle registered 900 spectrometer operated with some delays in relation to the discharge current peculiarity (dip) and with exposition varied from 100 ns to 100 {mu}s. The recorded spectral lines were used to estimate the density of the free-propagating plasma stream. The electron concentration, as estimated from the Stark broadening of the D{sub {beta}} line recorded at a distance of z = 30 cm from the electrode ends, changed from about 4x10{sup 17} cm{sup -3} to 2x10{sup 16} cm{sup -3} in about 30 {mu}s. Analogous spectroscopic measurements were carried out in experiments performed with targets made of carbon and sintered tungsten, which were placed at a distance of 15 cm from the electrode outlet, where q = 10{sup 10} W/cm{sup 2}, and at a distance of 30 cm, where q = 10{sup 9} W/cm{sup 2}. Particular attention was paid to investigation of a plasma layer formed in the front of the target. In that case the electron density, as estimated on the basis of carbon-and deuterium-ion lines, changed from about 3x10{sup 18} cm{sup -3} to 3x10{sup 16} cm{sup -3} in 30 {mu}s. For the target made of the sintered tungsten, which was placed at a distance of 30 cm, the recorded optical spectr a showed intense D{sub {alpha}} and D{sub {beta}} lines as well as CII-CIV lines, which covered tungsten (WI and WII) lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Role of The Electron Energy Balance in Plasma Thruster Instabilities

Using the fluid equations of Hall thruster plasma we analyze the influence of the electron energy balance on the stability of ion sound modes. For frequencies lower than {omega}{sub c} = 10{sup 7} s{sup -1} the gains and losses in the source term are approximately equal, thus the temperature can be in principle determined in terms of other dependent variables. This permits to reduce the number of equations. It appears however, that the new system can have complex characteristics in some regions. This in turn implies instability of certain modes with frequencies lower than {omega}{sub c}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatiotemporal dynamics of drift wave turbulence in a helicon discharge

This paper presents results of experimental investigations about the spatiotemporal evolution of turbulent structures in weakly developed turbulence in the linearly magnetized helicon discharge VINETA. On the basis of the dispersion behavior the governing instability has been identified as the drift wave instability. A key quantity of drift waves are the associated parallel currents, which are measured with high sensitive B-probes. The fluctuating parallel currents are correlated with the drift wave density fluctuations. Drift waves are driven into a weakly developed turbulent state, which is characterized by strong intermittency of plasma density fluctuations in the far plasma edge. Spatiotemporal measurements revealed that this intermittency can be ascribed to radially propagating turbulent structures, which form in the region of large radial plasma pressure gradient and propagate radially outwards. The radial propagation speeds are typically 10% of the local ion sound speed. Measurements of the parallel electron dynamics associated with the radially propagating structures strongly suggest that the parallel electron flux contributes significantly to the polarization of turbulent structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A single electrode room-temperature plasma jet device for biomedical applications

A single electrode room-temperature atmospheric pressure plasma plume generated between a high-voltage electrode and the surrounding room air is reported. The plasma plume has a peak current of about 360 mA. This is highest current carried by a room-temperature plasma plume ever reported. The rotational and vibrational temperature of the plasma plume is about 300 and 2950 K, respectively. Emission spectra show that excited species, such as O, OH, N{sub 2}{sup +}, etc., are present in the plasma plume.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Processing of the Signals From Plasma Focus Discharge

Recent experiments of D-D reactions at the PF-1000 device in IPPLM Warsaw made possible to determine more exactly the time and energy distribution of produced neutrons due to ten scintillation detectors placed at distances between 7 and 85 m from the neutron source in both axial directions. In this article the de-noising of neutron signal via wavelet transformation is described. The signals were filtered with using the discrete wavelet transformation. The Mallat multiresolution algorithm was used, which divides the signal using decomposition coefficients and a hard. This method was used for filtration of the neutron signals acquired from D-D fusion reaction at the device PF 1000 in IPPLM Warsaw. We present comparison of detected and reconstructed signals and a temporal evolution of neutron energy distribution for shot No. 6573.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction of Magnetic Field Surfaces of the NOVILLO Tokamak by means of the 3D-MAPTOR Code

A 3-D code has been developed in order to simulate the magnetic field lines in circular cross-section tokamaks. The toroidal magnetic field can be obtained from the individual fields of circular coils arranged around the torus, or alternatively, as a ripple-less field, as well as the vertical field coils, and divertor-like coils. The poloidal field is provided by a given toroidal current density profile. Proposing initial conditions for a magnetic filed line, it is integrated along the toroidal angle coordinate, and the Poincare maps can be obtained at any desired cross section plane along the torus. Following this procedure, the code allows to explore the necessary current values for the existence of magnetic field surfaces, allowing for deviations from axial symmetry, such as ripple effects. Therefore it is a good design instrument, in which different parameters and arrangements of coils can be tested. On the other hand, the current signals from experimental devices can be used in order to reconstruct the behaviour of the magnetic field surfaces, including the q(r) profiles. The reconstruction properties of the code are shown in this work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time scale analysis of ISTTOK probe data

Magnetic and turbulent activity in a tokamak plasma discharge may evolve in a complex trend during the discharge. In the ISTTOK tokamak, characterised by a short 30ms pulse duration, particle confinement of the order 0.3 ms and typical burst-like activity, the analysis of the time scales involved in the plasma activity is even more demanding. In this work, use is made of the Empirical Mode Decomposition (EMD) method as a tool for turbulence and MHD instability analysis obtained with Langmuir and magnetic probes, respectively. The time evolution of the energy content and wavenumber characterisation of fluctuating potential, edge plasma density and perturbed magnetic fields is investigated, with special emphasis on discharges where both limiter and electrode biasing were used to induce local sheared electric fields, thus affecting turbulence and consequently particle confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cherenkov Detector For Measurements Of Fast Electrons In CASTOR-Tokamak

The paper reports on capabilities of an improved version of the Cherenkov detector designed for measurements of fast electrons. The described technique enables the identification of electron beams, the measurements of their temporal characteristics, as well as the estimation of their spatial properties to be performed. Results obtained in the last experimental campaign with the CASTOR facility show good measuring capabilities of such a detection system. The radial distributions of fast-electron streams at different plasma densities, as well as the electron fluency dependences on discharge currents and toroidal magnetic fields are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing a Sine-Coil for Measurement of Plasma Displacements in IR-T1 Tokamak

A method for the measurement of the plasma position in the IR-T1 tokamak in toroidal coordinates is developed. A sine-coil, which is a Rogowski coil with a variable wiring density is designed and fabricated for this purpose. An analytic solution of the Biot-Savart law, which is used to calculate magnetic fields created by toroidal plasma current, is presented. Results of calculations are compared with the experimental data obtained in no-plasma shots with a toroidal current-carrying coil positioned inside the vessel to simulate the plasma movements. The results are shown a good linear behavior of plasma position measurements. The error is less than 2.5% and it is compared with other methods of measurements of the plasma position. This method will be used in the feedback position control system and tests of feedback controller parameters are ongoing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impurity Line Emissions in VUV Region of TCABR Tokamak

Spectral emissions in the vacuum ultraviolet region from 50 nm to 320 nm have been measured on TCABR tokamak using an one meter VUV spectrometer and a MCP coupled to a CCD detector. Among the 98 emissions classified, 37 are from first order diffraction, 29 are from second order, 24 are from third order, 7 from fourth order, and one from fifth order diffraction. Main impurity lines are OII to OVII, CII to CIV, NIII to N V, FVII, besides working gas plasma hydrogen Lyman lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral Line Profile Analysis Using Higher Diffraction Order in Vacuum Ultraviolet Region

Using a one meter VUV spectrometer and a MCP coupled to a CCD detector on TCABR tokamak, ion temperatures from impurity species have been measured and much better spectral resolution was obtained using higher order diffraction lines. Due to very small Doppler effect in the VUV region compared to large instrumental broadening, ion temperatures obtained from first order diffraction present large errors. The use of second, third and fourth order diffraction emissions increases the line broadening and results in lower error temperature measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗