Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Radiation hardness and precision timing study of silicon detectors for the CMS High Granularity Calorimeter (HGC)

The high luminosity upgraded LHC or Phase-II is expected to increase the instantaneous luminosity by a factor of 10 beyond the LHC's design value, expecting to deliver 250 fb –1 per year for a further 10 years of operation. Under these conditions the performance degradation due to integrated radiation dose will need to be addressed. The CMS collaboration is planning to upgrade the forward calorimeters. The replacement is called the High Granularity Calorimeter (HGC) and it will be realized as a sampling calorimeter with layers of silicon detectors interleaved. The sensors will be realized as pad detectors with sizes of less that ~1.0 cm 2 and an active thickness between 100 and 300 μm depending on the position, respectively, the expected radiation levels. For an integrated luminosity of 3000 fb –1 , the electromagnetic calorimetry will sustain integrated doses of 1.5 MGy (150 Mrads) and neutron fluences up to 10 16 neq/cm 2 . A radiation tolerance study after neutron irradiation of 300, 200, and 100 μm n-on-p and p-on-n silicon pads irradiated to fluences up to 1.6×10 16 neq/cm 2 is presented. In this work, the properties of these diodes studied before and after irradiation were leakage current, capacitance, charge collection efficiency, annealing effects and timing capability. The results of these measurements validate these sensors as candidates for the HGC system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

European Contributions to Fermilab Accelerator Upgrades and Facilities for the DUNE Experiment

The Proton Improvement Plan (PIP-II) to the FNAL accelerator chain and the Long-Baseline Neutrino Facility (LBNF) will provide the world's most intense neutrino beam to the Deep Underground Neutrino Experiment (DUNE) enabling a wide-ranging physics program. This document outlines the significant contributions made by European national laboratories and institutes towards realizing the first phase of the project with a 1.2 MW neutrino beam. Construction of this first phase is well underway. For DUNE Phase II, this will be closely followed by an upgrade of the beam power to > 2 MW, for which the European groups again have a key role and which will require the continued support of the European community for machine aspects of neutrino physics. Beyond the neutrino beam aspects, LBNF is also responsible for providing unique infrastructure to install and operate the DUNE neutrino detectors at FNAL and at the Sanford Underground Research Facility (SURF). The cryostats for the first two Liquid Argon Time Projection Chamber detector modules at SURF, a contribution of CERN to LBNF, are central to the success of the ongoing execution of DUNE Phase I. Likewise, successful and timely procurement of cryostats for two additional detector modules at SURF will be critical to the success of DUNE Phase II and the overall physics program. The DUNE Collaboration is submitting four main contributions to the 2026 Update of the European Strategy for Particle Physics process. This paper is being submitted to the 'Accelerator technologies' and 'Projects and Large Experiments' streams. Additional inputs related to the DUNE science program, DUNE detector technologies and R&D, and DUNE software and computing, are also being submitted to other streams.

43 PARTICLE ACCELERATORS↗

A new strips tracker for the upgraded ATLAS ITk detector

The ATLAS detector has been created and determined to function in the environment of the present Large Hadron Collider (LHC). At the next-generation tracking detector proposed for the High Luminosity LHC (HL-LHC), the so-called ATLAS Phase-II Upgrade, the fluences and radiation levels will be higher by as much as a factor of ten. The new sub-detectors must thus be faster, of larger area, more segmented and more radiation hard while the amount of inactive material should be minimized and the power supply to the front-end systems should be increased. For those reasons, the current inner tracker of the ATLAS detector will be fully replaced by an all-silicon tracking system that consists of a pixel detector at small radius close to the beam line and a large area strip tracker surrounding it. This report gives an overview of the design of the strip inner tracker (Strip ITk) and summarises the intensive R&D activities performed over the last years by the numerous institutes within the Strips ITk collaboration. These studies are accompanied with a strong prototyping effort to contribute to the optimisation of the Strip ITk's structure and components. This effort culminated recently in the release of the ATLAS Strips ITk Technical Design Report (TDR).

Si microstrip and pad detectors↗

The ABALONE Photosensor Panel Technology for Rare Decay and Rare Particle Detection

Our technology offers superior performance and cost-effectiveness that enables unprecedentedly sensitive next-generation detectors for the discovery of Dark Matter and other elusive phenomena. It addresses other important societal needs including previously nonexistent ultrasensitive medical scanners for early-stage cancer screening and radiation detection for homeland security. Our Phase-1 SBIR Project has provided the proof of concept for a particular embodiment of our detectors, and paved the way for a more detailed R&D effort, to be conducted if Phase-2 SBIR grant were awarded. This effort was supposed to be concerted in close collaboration with our customers/partners from several application areas in the fields of elementary particle and nuclear physics, as well as homeland (nuclear) security.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A sensitive and robust thin-film x-ray detector using 2D layered perovskite diodes

Solid-state radiation detectors, using crystalline semiconductors to convert radiation photons to electrical charges, outperform other technologies with high detectivity and sensitivity. Here, we demonstrate a thin-film x-ray detector comprised with highly crystalline two-dimensional Ruddlesden-Popper phase layered perovskites fabricated in a fully depleted p-i-n architecture. It shows high diode resistivity of 10 12 ohm·cm in reverse-bias regime leading to a high x-ray detecting sensitivity up to 0.276 C Gy air –1 cm –3 . Such high signal is collected by the built-in potential underpinning operation of primary photocurrent device with robust operation. The detectors generate substantial x-ray photon–induced open-circuit voltages that offer an alternative detecting mechanism. Furthermore, our findings suggest a new generation of x-ray detectors based on low-cost layered perovskite thin films for future x-ray imaging technologies.

47 OTHER INSTRUMENTATION↗

The second-order differential phase contrast and its retrieval for imaging with x-ray Talbot interferometry

Purpose: The x-ray differential phase contrast imaging implemented with the Talbot interferometry has recently been reported to be capable of providing tomographic images corresponding to attenuation-contrast, phase-contrast, and dark-field contrast, simultaneously, from a single set of projection data. The authors believe that, along with small-angle x-ray scattering, the second-order phase derivative {Phi}{sup Double-Prime }{sub s}(x) plays a role in the generation of dark-field contrast. In this paper, the authors derive the analytic formulae to characterize the contribution made by the second-order phase derivative to the dark-field contrast (namely, second-order differential phase contrast) and validate them via computer simulation study. By proposing a practical retrieval method, the authors investigate the potential of second-order differential phase contrast imaging for extensive applications. Methods: The theoretical derivation starts at assuming that the refractive index decrement of an object can be decomposed into {delta}={delta}{sub s}+{delta}{sub f}, where {delta}{sub f} corresponds to the object's fine structures and manifests itself in the dark-field contrast via small-angle scattering. Based on the paraxial Fresnel-Kirchhoff theory, the analytic formulae to characterize the contribution made by {delta}{sub s}, which corresponds to the object's smooth structures, to the dark-field contrast are derived. Through computer simulation with specially designed numerical phantoms, an x-ray differential phase contrast imaging system implemented with the Talbot interferometry is utilized to evaluate and validate the derived formulae. The same imaging system is also utilized to evaluate and verify the capability of the proposed method to retrieve the second-order differential phase contrast for imaging, as well as its robustness over the dimension of detector cell and the number of steps in grating shifting. Results: Both analytic formulae and computer simulations show that, in addition to small-angle scattering, the contrast generated by the second-order derivative is magnified substantially by the ratio of detector cell dimension over grating period, which plays a significant role in dark-field imaging implemented with the Talbot interferometry. Conclusions: The analytic formulae derived in this work to characterize the second-order differential phase contrast in the dark-field imaging implemented with the Talbot interferometry are of significance, which may initiate more activities in the research and development of x-ray differential phase contrast imaging for extensive preclinical and eventually clinical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics and Algorithm Enhancements for a Validated MCNP/X Monte Carlo Simulation Tool, Phase VII

Currently the US lacks an end-to-end (i.e., source-to-detector) radiation transport simulation code with predictive capability for the broad range of DHS nuclear material detection applications. For example, gaps in the physics, along with inadequate analysis algorithms, make it difficult for Monte Carlo simulations to provide a comprehensive evaluation, design, and optimization of proposed interrogation systems. With the development and implementation of several key physics and algorithm enhancements, along with needed improvements in evaluated data and benchmark measurements, the MCNP/X Monte Carlo codes will provide designers, operators, and systems analysts with a validated tool for developing state-of-the-art active and passive detection systems. This project is currently in its seventh year (Phase VII). This presentation will review thirty enhancements that have been implemented in MCNPX over the last 3 years and were included in the 2011 release of version 2.7.0. These improvements include 12 physics enhancements, 4 source enhancements, 8 tally enhancements, and 6 other enhancements. Examples and results will be provided for each of these features. The presentation will also discuss the eight enhancements that will be migrated into MCNP6 over the upcoming year.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Forward Drift Chamber for the GlueX experiment

The GlueX experiment will search for exotic mesons produced by 9 GeV linearly polarized photon beam from the 12 GeV CEBAF machine. A hermetic solenoid-based detector system that includes tracking and calorimetry is in the final construction phase. The Forward Drift Chamber consists of 24 circular planar drift chambers of 1 m diameter. Additional cathode strip information is required to achieve efficient pattern recognition in forward direction, resulting in 12,000 readout channels in total. Description and results from the tests of the completed detector will be presented. Challenges related to the specific features of the detector will be discussed. A small modification of the standard geometry allowed us to study the possibility for PID by cluster counting and investigate some gas properties based on single electron detection.

Pentchev, Lubomir↗

Forward Drift Chamber for the GlueX experiment

The GlueX experiment will search for exotic mesons produced by 9 GeV linearly polarized photon beams from the 12GeV CEBAF machine. Hermetic solenoid-based detector system that includes tracking and calorimetry is in the final construction phase. The Forward Drift Chamber consists of 24 circular planar drift chambers of $1~m$ diameter. Additional cathode strip information is required to achieve efficient pattern recognition in forward direction, resulting in 12,000 readout channels in total. Description and results from the tests of the completed detector will be presented. Challenges related to the specific features of the detector will be discussed.

Pentchev, Lubomir↗

Vapor-Phase-Gating-Induced Ultrasensitive Ion Detection in Graphene and Single-Walled Carbon Nanotube Networks

Designing ultrasensitive detectors often requires complex architectures, high-voltage operations, and sophisticated low-noise measurements. Here, it is shown that simple low-bias two-terminal DC-conductance values of graphene and single-walled carbon nanotubes are extremely sensitive to ionized gas molecules. Incident ions form an electrode-free, dielectric- or electrolyte-free, bias-free vapor-phase top-gate that can efficiently modulate carrier densities up to ≈0.6 × 10 13 cm -2 . Surprisingly, the resulting current changes are several orders of magnitude larger than that expected from conventional electrostatic gating, suggesting the possible role of a current-gain inducing mechanism similar to those seen in photodetectors. These miniature detectors demonstrate charge–current amplification factor values exceeding 10 8 A C -1 in vacuum with undiminished responses in open air, and clearly distinguish between positive and negative ions sources. At extremely low rates of ion incidence, detector currents show stepwise changes with time, and calculations suggest that these stepwise changes can result from arrival of individual ions. Lastly, these sensitive ion detectors are used to demonstrate a proof-of-concept low-cost, amplifier-free, light-emitting-diode-based low-power ion-indicator.

36 MATERIALS SCIENCE↗

Interactions between myocardial sympathetic denervation and left ventricular mechanical dyssynchrony: A CZT analysis

Background: A correlation between left ventricular (LV) dyssynchrony (LVD) and impaired myocardial sympathetic tone has been hypothesized. We sought to assess the interactions between regional LV sympathetic innervation, perfusion, and mechanical dyssynchrony. Methods: Eighty-three patients underwent evaluation of LV perfusion and sympathetic innervation on {sup 99m}Tc-tetrofosmin/{sup 123}I-metaiodobenzylguanidine ({sup 123}I-MIBG) imaging. The summed rest score and summed {sup 123}I-MIBG score (SS-MIBG) were computed. The extent of “innervation/perfusion” mismatch was defined as the number of denervated LV segments with relatively preserved perfusion. LVD was evaluated on phase analysis and the wall with latest mechanical activation identified. Results: LVD was revealed in 36 (43%) patients. Patients with LVD had more abnormal values of SRS (21 ± 9 vs 10 ± 8, P < 0.001) and SS-MIBG (29 ± 9 vs 17 ± 11, P < 0.001) than those without LVD. The presence of LVD also clustered with a higher burden of “innervation/perfusion” mismatch (P = 0.019). On per-wall analysis, LV walls with delayed mechanical activation showed a higher burden of “innervation/perfusion” mismatch (2.3 ± 1.4 segments) than normally contracting walls (1.3 ± 1.2 segments; P < 0.001). On multivariate analysis, the extent of “innervation/perfusion” mismatch was the only predictor of delayed mechanical activation (P = 0.029). Conclusions: Patients with LVD show an elevated burden of “innervation/perfusion” mismatch that is concentrated at the level of the most dyssynchronous walls.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The ProtoDUNE-SP LArTPC electronics production, commissioning, and performance

The ProtoDUNE-SP detector is a large-scale prototype of the Single-Phase (SP) Liquid Argon Time Projection Chamber (LArTPC) design proposed for the Deep Underground Neutrino Experiment (DUNE). 15,360 LArTPC wires are instrumented with low electronic noise pre-amplifier and digitization ASICs integrated into Front End Motherboards (FEMBs) operating at cryogenic temperature within the cryostat. The large number of electronics channels and high performance specifications required a large-scale production electronics quality control effort, careful installation into Anode Plane Assemblies (APAs), and rigorous detector commissioning. This successful collaboration-wide effort achieved a working LArTPC electronics channel percentage of 99.7% (15,318 of 15,360 channels in total), whose operating performance exceeded expectations. We summarize the ProtoDUNE-SP cold electronics design and quality control, installation, and commissioning efforts that enabled this excellent electronics performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Kinetic Parameters by Oscillated Experiments

The availability of reliable values of the kinetic parameters (effective delayed neutron fraction {beta} and effective mean neutron generation time {Lambda}) is important for reactor kinetic analyses and for reactivity monitoring when adopting the point kinetic approach. The kinetic parameters may be obtained either by simulations (Monte Carlo or deterministic) of the system or by direct measurements. Several methods have been proposed for the direct experimental determination of the kinetic parameters, e.g. control rod drops and noise analysis approaches, e.g. In this work, the problem of the determination of kinetic parameters in subcritical systems is tackled. The system is subjected to an oscillated source and the value of the ratio {beta}/{Lambda} is related to a measurable quantity when the system response reaches an equilibrium condition. In the analysis presented, a pure frequency is considered: when analyzing more complicated source periodic behaviours, a Fourier analysis can allow to isolate the contributions of individual frequencies. The phase difference between the oscillating source and the system response is adopted as the experimental observable. The method for the interpretation of the measurements is based on the standard point kinetic model. The response of the system is obtained by localized neutron detectors and, therefore, spatial and spectral effects may also affect the results. This drawback needs some further discussion and will be considered in the future work. The phase shift between the source signal and the system response may be analytically retrieved by Laplace transforming the point kinetic equations in the presence of an oscillated source. An explicit formula relates the phase shift to the ratio {beta}/{Lambda} and to the frequency of the source. Based on this relationship, the ratio {beta}/{Lambda} can be determined. To validate the technique, the experimental data are simulated by a numerical code solving the time-dependent diffusion equations for a source-driven system. The work allows to assess the possibility of the technique and its limits of applicability. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of ambient radon progeny decay rates and energy spectra in liquid argon using the MicroBooNE detector

We report measurements of radon progeny in liquid argon within the MicroBooNE time projection chamber (LArTPC). The presence of specific radon daughters in MicroBooNE’s 85 metric tons of active liquid argon bulk is probed with newly developed charge-based low-energy reconstruction tools and analysis techniques to detect correlated Bi 214 − Po 214 radioactive decays. Special datasets taken during periods of active radon doping enable new demonstrations of the calorimetric capabilities of single-phase neutrino LArTPCs for β and α particles with electron-equivalent energies ranging from 0.1 to 3.0 MeV. By applying Bi 214 − Po 214 detection algorithms to data recorded over a 46-day period, no statistically significant presence of radioactive Bi 214 is detected, and a limit on the activity is placed at < 0.35 mBq / kg at the 95% confidence level. This bulk Bi 214 radiopurity limit—the first ever reported for a liquid argon detector incorporating liquid-phase purification—is then further discussed in relation to the targeted upper limit of 1 mBq / kg on bulk Rn 222 activity for the DUNE neutrino detector. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Phase-Contrast Imaging of Submicron Particles in Unstained Lung Tissue

To access the risks and chances of deposition of submicron particles in the gas-exchange area of the lung, a precise three-dimensional (3D)-localization of the sites of deposition is essential--especially because local peaks of deposition are expected in the acinar tree and in individual alveoli. In this study we developed the workflow for such an investigation. We administered 200-nm gold particles to young adult rats by intratracheal instillation. After fixation and paraffin embedding, their lungs were imaged unstained using synchrotron radiation x-ray tomographic microscopy (SRXTM) at the beamline TOMCAT (Swiss Light Source, Villigen, Switzerland) at sample detector distances of 2.5 mm (absorption contrast) and of 52.5 mm (phase contrast). A segmentation based on a global threshold of grey levels was successfully done on absorption-contrast images for the gold and on the phase-contrast images for the tissue. The smallest spots containing gold possessed a size of 1-2 voxels of 370-nm side length. We conclude that a combination of phase and absorption contrast SRXTM imaging is necessary to obtain the correct segmentation of both tissue and gold particles. This method will be used for the 3D localization of deposited particles in the gas-exchange area of the lung.

60 APPLIED LIFE SCIENCES↗

Building Towards Discovery: Preparing for New Physics at the LHC [Final papers]

Particle physics today is at a crossroads. The Standard Model (SM) has survived four decades of experimental scrutiny and spurred multiple landmark discoveries, culminating with the 2012 discovery of the Higgs boson at the Large Hadron Collider (LHC). Yet we know that this model is incomplete. We live in a universe dominated by matter and energy unaccounted for by the SM– and the Higgs boson itself is improbably light. It falls to the current generation of high-energy physicists to go beyond the model and enter a new era of discovery. Andeen is leading a new research group at the University of Texas at Austin (UT-Austin) that is endeavoring to reveal novel physical phenomena through the discovery of new particles with the ATLAS detector at the LHC. A key element of our experience thus far has been collaborating closely with theorists to identify both interesting new physics models. In addition we work closely with electrical engineers in detector development. Our approach is therefore unique in its integration of theory, analysis and instrumentation, and is encapsulated in a three-pronged strategy. First is the essential task of analyzing our rapidly expanding dataset. I am directing my group in searches for vector-like quarks (VLQs). Should they exist, these hypothetical particles would indicate physics scenarios beyond the SM. Experimental constraints suggest VLQs decay preferentially to a third generation quark and a Higgs, W or Z boson. Today at 13 TeV, both multi-lepton (electron and muon) and jet substructure signatures are sensitive to identifying the VLQ decay products. The large Run 2 dataset (collected through 2018) of up to 150 fb -1 will allow us to simultaneously use multi-lepton signatures with jet-substructure in searches for new physics. UT-Austin is well positioned to be a leader in this area. Prof. P. Onyisi’s postdoctoral researchers and graduate students are searching for ttH signatures in three- and four-lepton channels and we benefit from their experience. We are also aided by the availability of the Texas Advanced Computing Center, which provides us with easy access to several high performance computing (HPC) systems. My previous experience in VLQ searches propels the work today. I have published both the first investigation into the single production of top partners (signatures of composite Higgs Models) of any LHC experiment 1 as well as one of the first analyses utilizing jet-substructure techniques to search for the single production of vector-like quarks. 2 Adding to this is my group’s work with the Liquid Argon (LAr) calorimeter, the primary instrument we use in detecting electrons. Second, my group is contributing to the operations of the LAr calorimeter while preparing to install and commission new electronic hardware (the Phase 1 upgrade) to this crucial component of the ATLAS detector. I have played a leading role in the development of a critical, radiation-hard, high-speed Analog-to-Digital Convertor (ADC) that is essential inselecting data collected by the LAr calorimeter. 3 This upgrade will improve the e!ciency with which we can select events in our detector. Postdoctoral researcher N. Nikiforou (based at CERN May 2016 onward) and graduate students (one based at CERN from the start of 2018 onward, with one additional graduate students from summer 2018) are growing our already deep experience in the operation of the LAr calorimeter to prepare for installation and commissioning of the new trigger readout in 2018-2019. My group will then be positioned to be the first to exploit the potential of the improved triggers in our multi-lepton searches for new physics. Third, a suite of preparations for a major detector upgrade, scheduled to be completed in 2024, are underway. My group is building hardware that will improve the electronic readout of the ATLAS detector. I am partnering with a group in the Electrical and Computer Engineering (ECE) Department at UT-Austin (Prof. N. Sun) to employ his work at the cutting edge of ADC research. We will support an ECE grad student for the layout of this design, and collaborate with engineering groups at Nevis Laboratory and the Electrical Engineering Department (Prof. P. Kinget) at Columbia University to integrate our ADC with gain selection circuits. We will provide this critical component of the ASIC at the challenging boundary of the analog and digital signals in the LAr calorimeter readout chain. Furthermore UT-Austin will lead the testing of this device during development and production (approximately 55,000 four-channel chips). This effort compliments my work as the deliverables manager for the LAr front-end ASICs for the US ATLAS HL-LHC project and strengthens the US commitment to that upgrade.In so doing, my group at the UT-Austin will be at the forefront of efforts to probe the structure of the universe to an unmatched degree both at the current LHC and with its future upgrades. Through both the ongoing analysis of data at the ATLAS detector and improvements to the detector itself, an answer to what lies beyond the SM may come within our grasp. My background in instrumentation and analysis allows my group to establish a singular research effort on the ATLAS experiment. In addition to answering fundamental questions about the subatomic world, the technologies developed could advance the broader scientific community and result in valuable spin-offs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of secondary phases in modified vertical bridgman growth czt

CdZnTe or 'CZT' crystals are highly suitable for use as a room temperature based spectrometer for the detection and characterization of gamma radiation. Over the last decade, the methods for growing high quality CZT have improved the quality of the produced crystals however there are material features that can influence the performance of these materials as radiation detectors. For example, various structural heterogeneities within the CZT crystals, such as twinning, pipes, grain boundaries (polycrystallinity), and secondary phases (SP) can have a negative impact on the detector performance. In this study, a CZT material was grown by the modified vertical Bridgman growth (MVB) method with zone leveled growth without excess Te in the melt. Visual observations of material from the growth of this material revealed significant voids and SP. Three samples from this material was analyzed using various analytical techniques to evaluate its electrical properties, purity and detector performance as radiation spectrometers and to determine the morphology, dimension and elemental/structural composition of one of the SP in this material. This material was found to have a high resistivity but poor radiation spectrometer performance. It had SP that were rich in polycrystalline aluminum oxide (Al{sub 2}O{sub 3}), metallic Te and polycrystalline CdZnTe and 15 to 50 {micro}m in diameter. Bulk elemental analyses of sister material from elsewhere in the boule did not contain high levels of Al so there is considerable elemental impurity heterogeneity within the boule from this growth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Timing with the CMS MIP Timing Detector

The Compact Muon Solenoid (CMS) detector at the CERN Large Hadron Collider (LHC) is undergoing an extensive Phase II upgrade program to prepare for the challenging conditions of the High Luminosity LHC (HL-LHC). A new timing layer is designed to measure minimum ionizing particles (MIPs) with a time resolution of 30 ps and hermetic coverage up to a pseudo-rapidity of |η|=3. This MIP Timing Detector (MTD) will consist of a central barrel region based on LYSO:Ce crystals read out with SiPMs and two end-caps instrumented with radiation-tolerant Low Gain Avalanche Detectors (LGADs). The precision time information from the MTD will reduce the effects of the high levels of pile-up expected at the HL-LHC and will bring new and unique capabilities to the CMS detector. The time information assigned to each track will enable the use of 4D-vertexing which will render a 5-fold pile-up reduction thus recovering the current conditions. Precision timing will also enable new time-based isolations and improved b-tagging algorithms. All of this translates into a 20% gain in effective luminosity when looking at di-Higgs boson events decaying to a pair of b-quarks and two photons. We present the current status and ongoing R&D of the MTD, including implications on the physics reach at the HL-LHC and test beam results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗