Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PATHOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

RTO Technical Publications: A Quarterly Listing

This is a listing of recent unclassified RTO technical publications processed by the NASA Center for AeroSpace Information covering the period from July 1, 2005 to September 30, 2005; and available in the NASA Aeronautics and Space Database. Contents include: Aeroelastic Deformation: Adaptation of Wind Tunnel Measurement Concepts to Full-Scale Vehicle Flight Testing; Actively Controlling Buffet-Induced Excitations; Modelling and Simulation to Address NATO's New and Existing Military Requirements; Latency in Visionic Systems: Test Methods and Requirements; Personal Hearing Protection including Active Noise Reduction; Virtual Laboratory Enabling Collaborative Research in Applied Vehicle Technologies; A Method to Analyze Tail Buffet Loads of Aircraft; Particle Image Velocimetry Measurements to Evaluate the Effectiveness of Deck-Edge Columnar Vortex Generators on Aircraft Carriers; Introduction to Flight Test Engineering, Volume 14; Pathological Aspects and Associated Biodynamics in Aircraft Accident Investigation;

Source record↗

Controlling Reflections from Mesh Refinement Interfaces in Numerical Relativity

A leading approach to improving the accuracy on numerical relativity simulations of black hole systems is through fixed or adaptive mesh refinement techniques. We describe a generic numerical error which manifests as slowly converging, artificial reflections from refinement boundaries in a broad class of mesh-refinement implementations, potentially limiting the effectiveness of mesh- refinement techniques for some numerical relativity applications. We elucidate this numerical effect by presenting a model problem which exhibits the phenomenon, but which is simple enough that its numerical error can be understood analytically. Our analysis shows that the effect is caused by variations in finite differencing error generated across low and high resolution regions, and that its slow convergence is caused by the presence of dramatic speed differences among propagation modes typical of 3+1 relativity. Lastly, we resolve the problem, presenting a class of finite-differencing stencil modifications which eliminate this pathology in both our model problem and in numerical relativity examples.

Baker, John G.↗

Effects of Walking Speed and Visual-Target Distance on Toe Trajectory During Swing Phase

After spaceflight, astronauts experience disturbances in their ability to walk and maintain postural stability (Bloomberg, et al., 1997). One of the post-flight neurovestibular assessments requires that the astronaut walk on a treadmill at 1.8 m/sec (4.0 mph), while performing a visual acuity test, set at two different distances ( far and near ). For the first few days after landing, some crewmembers can not maintain the required pace, so a lower speed may be used. The slower velocity must be considered in the kinematic analysis, because Andriacchi, et al. (1977) showed that in clinical populations, changes in gait parameters may be attributable more to slower gait speed than pathology. Studying toe trajectory gives a global view of control of the leg, since it involves coordination of muscles and joints in both the swing and stance legs (Karst, et al., 1999). Winter (1992) and Murray, et al. (1984) reported that toe clearance during overground walking increased slightly as speed increased, but not significantly. Also, toe vertical peaks in both early and late swing phase did increase significantly with increasing speed. During conventional testing of overground locomotion, subjects are usually asked to fix their gaze on the end of the walkway a far target. But target (i.e., visual fixation) distance has been shown to affect head and trunk motion during treadmill walking (Bloomberg, et al., 1992; Peters, et al., in review). Since the head and trunk can not maintain stable gaze without proper coordination with the lower body (Mulavara & Bloomberg, 2003), it would stand to reason that lower body kinematics may be altered as well when target distance is modified. The purpose of this study was to determine changes in toe vertical trajectory during treadmill walking due to changes in walking speed and target distance.

Miller, Chris↗

High Frequency QRS ECG Accurately Detects Cardiomyopathy

High frequency (HF, 150-250 Hz) analysis over the entire QRS interval of the ECG is more sensitive than conventional ECG for detecting myocardial ischemia. However, the accuracy of HF QRS ECG for detecting cardiomyopathy is unknown. We obtained simultaneous resting conventional and HF QRS 12-lead ECGs in 66 patients with cardiomyopathy (EF = 23.2 plus or minus 6.l%, mean plus or minus SD) and in 66 age- and gender-matched healthy controls using PC-based ECG software recently developed at NASA. The single most accurate ECG parameter for detecting cardiomyopathy was an HF QRS morphological score that takes into consideration the total number and severity of reduced amplitude zones (RAZs) present plus the clustering of RAZs together in contiguous leads. This RAZ score had an area under the receiver operator curve (ROC) of 0.91, and was 88% sensitive, 82% specific and 85% accurate for identifying cardiomyopathy at optimum score cut-off of 140 points. Although conventional ECG parameters such as the QRS and QTc intervals were also significantly longer in patients than controls (P less than 0.001, BBBs excluded), these conventional parameters were less accurate (area under the ROC = 0.77 and 0.77, respectively) than HF QRS morphological parameters for identifying underlying cardiomyopathy. The total amplitude of the HF QRS complexes, as measured by summed root mean square voltages (RMSVs), also differed between patients and controls (33.8 plus or minus 11.5 vs. 41.5 plus or minus 13.6 mV, respectively, P less than 0.003), but this parameter was even less accurate in distinguishing the two groups (area under ROC = 0.67) than the HF QRS morphologic and conventional ECG parameters. Diagnostic accuracy was optimal (86%) when the RAZ score from the HF QRS ECG and the QTc interval from the conventional ECG were used simultaneously with cut-offs of greater than or equal to 40 points and greater than or equal to 445 ms, respectively. In conclusion 12-lead HF QRS ECG employing RAZ scoring is a simple, accurate and inexpensive screening technique for cardiomyopathy. Although HF QRS ECG is highly sensitive for cardiomyopathy, its specificity may be compromised in patients with cardiac pathologies other than cardiomyopathy, such as uncomplicated coronary artery disease or multiple coronary disease risk factors. Further studies are required to determine whether HF QRS might be useful for monitoring cardiomyopathy severity or the efficacy of therapy in a longitudinal fashion.

Schlegel, Todd T.↗

Three-Dimensional Human Bronchial-Tracheal Epithelial Tissue-Like Assemblies (TLAs) as Hosts for Severe Acute Respiratory Syndrome (SARS)-CoV Infection

A three-dimensional (3-D) tissue-like assembly (TLA) of human bronchial-tracheal mesenchymal (HBTC) cells with an overlay of human bronchial epithelial (BEAS-2B) cells was constructed using a NASA Bioreactor to survey the infectivity of SARS-CoV. This TLA was inoculated with a low passage number Urbani strain of SARS-CoV. At selected intervals over a 10-day period, media and cell aliquots of the 3-D TLA were harvested for viral titer assay and for light and electron microscopy examination. All viral titer assays were negative in both BEAS-2B two-dimensional monolayer and TLA. Light microscopy immunohistochemistry demonstrated antigen-antibody reactivity with anti-SARS-CoV polyclonal antibody to spike and nuclear proteins on cell membranes and cytoplasm. Coronavirus Group 2 cross-reactivity was demonstrated by positive reaction to anti-FIPV 1 and anti-FIPV 1 and 2 antibodies. TLA examination by transmission electron microscopy indicated increasing cytoplasmic vacuolation with numerous electron-dense bodies measuring 45 to 270 nm from days 4 through 10. There was no evidence of membrane blebbing, membrane duplication, or fragmentation of organelles in the TLAs. However, progressive disruption of endoplasmic reticulum was observed throughout the cells. Antibody response to SARS-CoV specific spike and nucleocapsid glycoproteins, cross-reactivity with FIPV antibodies, and the cytoplasmic pathology suggests this HBTE TLA model is permissive to SARS-CoV infection.

Suderman, M. T.↗

Anti-radiation vaccine: Immunologically-based Prophylaxis of Acute Toxic Radiation Syndromes Associated with Long-term Space Flight

Protecting crew from ionizing radiation is a key life sciences problem for long-duration space missions. The three major sources/types of radiation are found in space: galactic cosmic rays, trapped Van Allen belt radiation, and solar particle events. All present varying degrees of hazard to crews; however, exposure to high doses of any of these types of radiation ultimately induce both acute and long-term biological effects. High doses of space radiation can lead to the development of toxicity associated with the acute radiation syndrome (ARS) which could have significant mission impact, and even render the crew incapable of performing flight duties. The creation of efficient radiation protection technologies is considered an important target in space radiobiology, immunology, biochemistry and pharmacology. Two major mechanisms of cellular, organelle, and molecular destruction as a result of radiation exposure have been identified: 1) damage induced directly by incident radiation on the macromolecules they encounter and 2) radiolysis of water and generation of secondary free radicals and reactive oxygen species (ROS), which induce chemical bond breakage, molecular substitutions, and damage to biological molecules and membranes. Free-radical scavengers and antioxidants, which neutralize the damaging activities of ROS, are effective in reducing the impact of small to moderate doses of radiation. In the case of high doses of radiation, antioxidants alone may be inadequate as a radioprotective therapy. However, it remains a valuable component of a more holistic strategy of prophylaxis and therapy. High doses of radiation directly damage biological molecules and modify chemical bond, resulting in the main pathological processes that drive the development of acute radiation syndromes (ARS). Which of two types of radiation-induced cellular lethality that ultimately develops, apoptosis or necrosis, depends on the spectrum of incident radiation, dose, dose rate, and functional conditions of impacted cells/organisms. The administration of an experimental anti-radiation vaccine may provide an immunologically based, adjunct method of prevention or prophylaxis against clinical ARS. The administration of experimental anti-radiation serum (ARS) and the use of the blood dialysis methods, such as immune plasma-sorption, may assist in the clearance of radiation-specific toxins and may enhance established strategies for the mitigation of the biological effects leading to ARS, and should be evaluated for use on exploration-class space missions.

Popov, Dmitri↗

The Lunar Environment: Determining the Health Effects of Exposure to Moon Dusts

The Earth s moon presents a hostile environment in which to live and work. There is no atmosphere to protect its surface from the ravages of solar wind and micrometeorite impacts. As a result, the moon s surface is covered with a thin layer of fine, charged, reactive dust capable of entering habitats and vehicle compartments, where it can result in crewmember health problems. During the Apollo missions, lunar dusts were introduced into the crew vehicle, resulting in direct exposure and occasional reports of respiratory, dermal and ocular irritation. In order to study the toxicological effects of lunar dust, NASA formed the Lunar Airborne Dust Toxicity Advisory Group (LADTAG). This interdisciplinary group is comprised of leading experts in space toxicology, lunar geology, space medicine and biomedical research. LADTAG has demonstrated that lunar soil contains several types of reactive dusts, including an extremely fine respirable component. These dusts have highly reactive surfaces in the lunar environment; the grains contain surface coatings which are generated by vapor phases formed by hypervelocity impact of micrometeorites. This unique class of dusts has surface properties that are unlike any Earth based analog. These distinctive properties are why lunar dusts are of great toxicological interest. Understanding how these reactive components behave "biochemically" in a moisture-rich pulmonary environment will aid in determining how toxic these particles are to humans. The data obtained from toxicological examination of lunar dusts will determine the human risk criteria for lunar dust exposure and produce a lunar health standard. LADTAG s analysis of lunar dusts and lunar dust simulants will include detailed lunar particle characterizations, determining the properties of particle activation, reactivation of lunar dust, the process of dust passivation and discerning the pathology of lunar dust exposure via inhalation, intratracheal instillation, cell culture exposure, dermal exposure and ocular exposure. The resulting health standard will be time-based and will vary by the duration and type of exposure. It may also be necessary to set multiple standards for different types of lunar dust, as well as for dust in its activated form vs. aged & passivated dust. This standard, set to protect the health of our robust astronaut crews, will not only impact NASA medical operations, but engineering designs as well. The data from our multidisciplinary research are vital in developing remediation devices and environmental monitors. Ultimately, the engineering and safety groups will design and develop countermeasures for space vehicles, suits, rovers and habitats that will be sustained within the limits of the health standard.

Khan-Mayberry, Noreen↗

PillCam(TradeMark), a Noninvasive Endoscopic Device for the Measurement of Gastrointestinal Motility Changes

Introduction: Bioavailability and effectiveness of drugs given by mouth are governed in part by gastrointestinal (GI) motility and function. Microgravity has been shown to decrease GI motility as indicated by a 3 fold increase in gastrointestinal transit time (GITT). The PillCam(TradeMark), an endoscopic camera embedded in a capsule, is a novel noninvasive and unobtrusive device that is used for the diagnosis of GI pathology. The purpose of this study is to evaluate the usefulness of PillCam(TradeMark) as an alternative to the Lactulose Breath Hydrogen Test (LBHT) for estimating GI motility. The sensitivity and applicability of this device for detection and estimation of the effect of promethazine, a deterrent, and caffeine, a prokinetic, on GI motility were also examined. Method: In this semi-randomized cross-over design study, six male and six female subjects were administered the following 4 treatments: PillCam(TradeMark) alone, PillCam(TradeMark)+Lactulose (10g), PillCam(TradeMark)+caffeine (200mg), and PillCam(TradeMark)+Promethazine (50mg). Results: GITT ranged between 1:24 and 7:52 hr:min. Lactulose did not alter GITT. A significant increase in GITT was noticed after administration of PMZ when compared to values from PillCam(TradeMark) treatment alone or PillCam(TradeMark)+Lactulose treatment. No difference in GITT after caffeine treatment was noticed. While there were no gender related differences in GITT after administration of PillCam(TradeMark) or with lactulose, a significant difference (p<.05) between genders was observed after promethazine administration with mean GITT higher in males (5:50 hr:min) than females (4:15 hr:min). Conclusion: The PillCam(TradeMark) capsule is applicable for the determination of GITT using time stamped GI images. It can be successfully used for the assessment of drug induced changes in GI motility and therefore, may be applicable for microgravity and analog environment studies on GI motility and function.

Vaksman, Zahman↗

Toxicity of Carbon Nanotubes and Its Implications for Occupational and Environmental Health

Carbon nanotubes (CNTs), which possess desirable electrical and mechanical properties, potentially have wide industrial applications. CNTs exist in two forms, single-wall (SW) and multi-wall (MW). There has been great concern that if CNTs enter the work environment as suspended respirable particulate matter (PM), they could pose an inhalation hazard. The results of recent rodent studies have collectively shown that CNTs can produce inflammation, epithelioid granulomas, fibrosis, and biochemical changes in the lungs. Studies in mice given equal amounts of test dusts showed that CNTs were more toxic than quartz and produced lesions that became progressively more pronounced. These results have led us to recommend that respirable CNT dust be considered a serious occupational health hazard, and that exposure limits be established in the expectation of expanded industrial applications. CNTs, which are totally insoluble and fibrous, would be expected to be more biopersistent than mineral fibers. Biopersistence is the key factor determining the long-term toxicity of mineral fibers and certainly of CNTs too. We have postulated that the electrical and fibrous properties of CNTs also play important roles in the toxicity of CNTs in the lungs. Recently, MWCNTs have been found in ultrafine PM aggregates in combustion streams of methane, propane, and natural-gas flames of typical stoves; indoor and outdoor fine (< 2.5 micron) PM samples were reported to contain significant fractions of MWCNTs. Environmental fine PM is mainly formed from combustion of fuels, and fine PM has been reported to be a major contributor to the induction of cardiopulmonary diseases by pollutants. Given that manufactured SWCNTs and/or MWCNTs have elicited pathological changes in the lungs and heart, we have postulated that exposure to combustion-generated MWCNTs in fine PM in the air may play a significant role in air pollution-related cardiopulmonary diseases. Therefore, CNTs from manufacturing and combustion sources in the environment could have adverse effects on human health.

Lam, Chiu-wing↗

Cardiac Repolarization Abnormalities and Potential Evidence for Loss of Cardiac Sodium Currents on ECGs of Patients with Chagas' Heart Disease

Some individuals with Chagas disease develop right precordial lead ST segment elevation in response to an ajmaline challenge test, and the prevalence of right bundle branch block (RBBB) is also high in Chagas disease. Because these same electrocardiographic abnormalities occur in the Brugada syndrome, which involves genetically defective cardiac sodium channels, acquired damage to cardiac sodium channels may also occur in Chagas disease. We studied several conventional and advanced resting 12-lead/derived Frank-lead ECG parameters in 34 patients with Chagas -related heart disease (mean age 39 14 years) and in 34 age-/gender-matched healthy controls. All ECG recordings were of 5-10 min duration, obtained in the supine position using high fidelity hardware/software (CardioSoft, Houston, TX). Even after excluding those Chagas patients who had resting BBBs, tachycardia and/or pathologic arrhythmia (n=8), significant differences remained in multiple conventional and advanced ECG parameters between the Chagas and control groups (n=26/group), especially in their respective QT interval variability indices, maximal spatial QRS-T angles and low frequency HRV powers (p=0.0006, p=0.0015 and p=0.0314 respectively). In relation to the issue of potential damage to cardiac sodium channels, the Chagas patients had: 1) greater than or equal to twice the incidence of resting ST segment elevation in leads V1-V3 (n=10/26 vs. n=5/26) and of both leftward (n=5/26 versus n=0/26) and rightward (n=7/26 versus n=3/26) QRS axis deviation than controls; 2) significantly increased filtered (40-250 Hz) QRS interval durations (92.1 8.5 versus 85.3 plus or minus 9.0 ms, p=0.022) versus controls; and 3) significantly decreased QT and especially JT interval durations versus controls (QT interval: 387.5 plus or minus 26.4 versus 408.9 plus or minus 34.6 ms, p=0.013; JT interval: 290.5 plus or minus 26.3 versus 314.8 plus or minus 31.3 ms; p=0.0029). Heart rates and Bazett-corrected QTc/JTc intervals were not significantly different between groups. Patients with Chagas heart disease have increased cardiac repolarization abnormalities, especially by advanced ECG. Moreover, as a group, they have decreased uncorrected JT and QT interval durations and increased filtered QRS interval durations (versus age/gender-matched controls), all suggesting a potential loss of cardiac sodium channel function that might be mediated, in part, by cardiac autonomic damage. Overall findings support Brugada et al's recent hypothesis that the pathway leading to sudden death may often be similar in Chagas' disease and Brugada syndrome i.e., damage to the sodium channel (infectious/immunologic/autonomic in Chagas' genetic in Brugada) with consequent loss of sodium currents may facilitate a phase II-reentry based arrhythmic substrate for ventricular fibrillation in both conditions. In general, JT interval-related results have been underreported in the Chagas literature.

Schlegel, T. T.↗

Propellant Analysis and Distillation Unit Design

The NASA White Sands Test Facility (WSTF) routinely operates hypergolic propulsion systems. Some of the onsite activities include performing long duration studies on the operational life of these systems. A few of them have been in use for over twenty years. During this span of time contamination has built up in the propellant and some of the distribution infrastructure. This study investigated the nature of this contamination, the pathology of its generation, and developed a process for removal of the contamination that was cost efficient with minimal waste generation.

Barragan, Michelle H.↗

Mechanical Properties of Cells

Many physiologic and pathologic processes alter the biomechanical properties of the tissue they affect, and these changes may be manifest at the single cell level. The normal and abnormal mechanical properties of a given cell type can be established with the aid of an atomic force microscope (AFM), nonetheless, consistency in the area of the tip has been a mayor limitation of using the AFM for quantitative measurements of mechanical properties. This project attempts to overcome this limitation by using materials with a known elastic modulus, which resembles the one of the cell, to create force-deformation curves to calculate the area of indentation by means of Hooke s Law (sigma = E(epsilon)), which states that stress (sigma) is proportional to the strain (epsilon) where the constant of proportionality, E, is called the Young s modulus, also referred as the elastic modulus. Hook s Law can be rearranged to find the area of indentation (Area= Force/ E(epsilon)), where the indentation force is defined by the means of the added mass spring calibration method.

Bradley, Robert↗

Exploring Hypersonic, Unstructured-Grid Issues through Structured Grids

Pure-tetrahedral unstructured grids have been shown to produce asymmetric heat transfer rates for symmetric problems. Meanwhile, two-dimensional structured grids produce symmetric solutions and as documented here, introducing a spanwise degree of freedom to these structured grids also yields symmetric solutions. The effects of grid skewness and other perturbations of structured-grids are investigated to uncover possible mechanisms behind the unstructured-grid solution asymmetries. By using controlled experiments around a known, good solution, the effects of particular grid pathologies are uncovered. These structured-grid experiments reveal that similar solution degradation occurs as for unstructured grids, especially for heat transfer rates. Non-smooth grids within the boundary layer is also shown to produce large local errors in heat flux but do not affect surface pressures.

Mazaheri, Ali R.↗

Microscopic Observation of Self-Propagation of Calcifying Nanoparticles (Nanobacteria)

Biologists typically define living organisms as carbon and water-based cellular forms with :self-replication" as the fundamental trait of the life process. However, this standard dictionary definition of life does not help scientists to categorize self-replicators like viruses, prions, proteons and artificial life. CNP also named nanobacteria were discovered in early 1990s as about 100 nanometer-sized bacteria-like particles with unique apatite mineral-shells around them, and found to be associated with pathological-calcification related diseases. Although CNP have been isolated and cultured from mammalian blood and diseased calcified tissues, and their biomineralizing properties well established, their biological nature and self-replicating capability have always been severely challenged. The terms "self-replication", "self-assembly" or "self-propagation" have been widely used for all systems including nanomachines, crystals, computer viruses and memes. In a simple taxonomy, all biological and non-biological "self replicators", have been classified into "living" or "nonliving" based on the properties of the systems and the amount of support they require to self-replicate. To enhance our understanding about self-replicating nature of CNP, we have investigated their growth in specific culture conditions using conventional inverted light microscope and BioStation IM, Nikon s latest time-lapse imaging system. Their morphological structure was examined using scanning (SEM) and transmission (TEM) electron microscopy. This present study, in conjunction with previous findings of metabolic activity, antibiotic sensitivity, antibody specificity, morphological aspects and infectivity, all concomitantly validate CNP as living self-replicators.

Mathew, Grace↗

Advanced Electrocardiographic Predictors of Sudden Death in Familial Dysautonomia

To identify accurate predictors for the risk of sudden death in patients with familial dysautonomia (FD). Ten-minute resting high-fidelity 12-lead ECGs were obtained from 14 FD patients and 14 age/gender-matched healthy subjects. Multiple conventional and advanced ECG parameters were studied for their ability to predict sudden death in FD over a subsequent 4.5-year period, including multiple indices of linear and non-linear heart rate variability (HRV); QT variability; waveform complexity; high frequency QRS; and derived Frank-lead parameters. Four of the 14 FD patients died suddenly during the follow-up period, usually with concomitant pulmonary disorder. The presence of low vagally-mediated HRV was the ECG finding most predictive of sudden death. Concomitant left ventricular hypertrophy and other ECG abnormalities such as increased QTc and JTc intervals, spatial QRS-T angles, T-wave complexity, and QT variability were also present in FD patients, suggesting that structural heart disease is fairly common in FD. Although excessive or unopposed cardiac vagal (relative to sympathetic) activity has been postulated as a contributor to sudden death in FD, the presence of low vagally-mediated HRV was paradoxically the best predictor of sudden death. However, we suggest that low vagally-mediated HRV be construed not as a direct cause of sudden death in FD, but rather as an effect of concurrent pathological processes, especially hypoxia due to pulmonary disorders and sleep apnea, that themselves increase the risk of sudden death in FD and simultaneously diminish HRV. We speculate that adenosine may play a role in sudden death in FD, possibly independently of vagal activity, and that adenosine inhibitors such as theophylline might therefore be useful as prophylaxis in this disorder.

Solaimanzadeh, I.↗

Wire Crimp Termination Verification Using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp termination and wire is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. Various crimp junction pathologies such as undercrimping, missing wire strands, incomplete wire insertion, partial insulation removal, and incorrect wire gauge are ultrasonically tested, and their results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently (as evidenced with destructive testing) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. Finally, an approach for application to multipin indenter type crimps will be discussed.

Perey, Daniel F.↗

Wire Crimp Connectors Verification using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to quantitatively assess wire crimp connections is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp connector and wire is shown to correlate with the results of a destructive pull test, which previously has been used to assess crimp wire junction quality. Various crimp junction pathologies (missing wire strands, incorrect wire gauge, incomplete wire insertion in connector) are ultrasonically tested, and their results are correlated with pull tests. Results show that the ultrasonic measurement technique consistently (as evidenced with pull-testing data) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying the technique while wire crimps are installed is also presented.

Cramer, K. Elliott↗

Realtime Multichannel System for Beat to Beat QT Interval Variability

The measurement of beat-to-beat QT interval variability (QTV) shows clinical promise for identifying several types of cardiac pathology. However, until now, there has been no device capable of displaying, in real time on a beattobeat basis, changes in QTV in all 12 conventional leads in a continuously monitored patient. While several software programs have been designed to analyze QTV, heretofore, such programs have all involved only a few channels (at most) and/or have required laborious user interaction or offline calculations and postprocessing, limiting their clinical utility. This paper describes a PC-based ECG software program that in real time, acquires, analyzes and displays QTV and also PQ interval variability (PQV) in each of the eight independent channels that constitute the 12lead conventional ECG. The system also processes certain related signals that are derived from singular value decomposition and that help to reduce the overall effects of noise on the realtime QTV and PQV results.

Starc, Vito↗