Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “P”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Flight Measurements of the Flying Qualities of a Lockheed P-80A Airplane (Army No. 44-85099): Longitudinal-Stability and -Control Characteristics

This report contains the flight-test results of the longitudinal-stability and -control phase of a general flying qualities investigation of the Lockheed P-80A airplane (Army No. 44-85099). The tests were conducted at indicated airspeeds up to 530 miles per hour (0.76 Mach number) at low altitude and up to 350 miles per hour (0.82) Mach number) at high altitude. These tests showed that the flying qualities of the airplane were in accordance with the requirements of the Army Air Forces Stability and Control Specification except for excessive elevator control forces in maneuvering flight and the inadequacy of the longitudinal trimming control at low airspeeds.

Anderson, Seth B.↗

Measurement of Peroxyacetyl Nitrate (PAN), Peroxypropionyl Nitrate (PPN) and Peroxymethacryloyl Nitrate (MPAN) during TRACE-P

In Fall 2000, the PANs gas chromatograph (GC) was improved and prepared for installation on the NASA P-3. A number of experiments were conducted in conjunction with the NCAR NO,, instrument (B. Ridley) to settle some of the fine details of the output of the calibration system for each instrument. In addition, the sampling frequency was improved.

Flocke, Frank↗

New Particle Formation in Anthropogenic Plumes Advecting from Asia Observed During TRACE-P

The characteristics and sources of what are believed to be newly formed 3 to 4 nm particles in anthropogenic plumes advecting from Asian are reported. Airborne measurements were made from March to April 2001 as part of the NASA TRACE-P experiment at latitudes ranging from North of the Philippines to Northern Japan (20 to 45 deg. N). In the more polluted plumes, high concentrations of 3 to 4 nm diameter particles (less than 100/qu cm) were observed both within and along the upper outer edges of plumes that were identified by enhanced carbon monoxide and fine particulate sulfate concentrations. The results from two research flights are investigated in detail. Three to four-nm particle concentrations are generally correlated with gas phase sulfuric acid and found in regions of low surface areas relative to the immediate surroundings or where there are steep transitions to lower surface areas. Sulfuric acid and surface area concentrations in the most polluted plume reached 6 x l0(exp 7) and 750 micro sq m/qu cm, respectively, in regions of particle formation. In contrast to these anthropogenic plumes, few 3 to 4 nm particles were observed in the clean background and few were detected within a volcanic plume where the studies highest H2SO4 concentrations (less than lO(exp 8)/qu cm) were recorded. Enhanced SO2 concentrations in the range of approximately 2 to 7 ppb, in conjunction with other unidentified, possibly coemitted species, appear to be the driving factor for nucleation. (0345, 4801); 0322 Atmospheric Composition and Structure: Constituent sources and sinks; 0345 Atmospheric Composition and Structure: Pollution-urban and regional (0305); 4801 Oceanography: Biological and Chemical: Aerosols (0305).

Weber, R. J.↗

Intercomparisons of Airborne Measurements of Aerosol Ionic Chemical Composition during TRACE-P and ACE-Asia

As part of the two field studies, Transport and Chemical Evolution over the Pacific (TRACE-P), and the Asian Aerosol Characterization Experiment (ACEAsia), the inorganic chemical composition of tropospheric aerosols was measured over the western Pacific from three separate aircraft using various methods. Comparisons are made between the rapid online techniques of the Particle Into Liquid Sampler (PILS) for measurement of a suite of fine particle ionic compounds and a mist chamber (MC/IC) measurement of fine sulfate, and the longer time-integrated filter and multi-orifice impactor (MOI) measurements. Comparisons between identical PILS on two separate aircraft flying in formation showed that they were highly correlated (e.g., sulfate r(sup 2) of 0.95), but were systematically different by 10 +/- 5% (linear regression slope and 95% confidence bounds), and had generally higher concentrations on the aircraft with a low turbulence inlet and shorter inlet-to-instrument transmission tubing. Comparisons of PILS and mist chamber measurements of fine sulfate on two different aircraft during formation flying had an 3 of 0.78 and a relative difference of 39% +/- 5%. MOI ionic data integrated to the PILS upper measurement size of 1.3 pm sampling from separate inlets on the same aircraft showed that for sulfate, PILS and MOI were within 14% +/- 6% and correlated with an r(sup 2) of 0.87. Most ionic compounds were within f 30%, which is in the range of differences reported between PILS and integrated samplers from ground-based comparisons. In many cases, direct intercomparison between the various instruments is difficult due to differences in upper-size detection limits. However, for this study, the results suggest that the fine particle mass composition measured from aircraft agree to within 30-40%.

Ma, Y.↗

Electron-H P-Wave Elastic Scattering

In previous papers [Bhatia and Temkin, Phys. Rev. A 64, 032709-1 (2001), Phys. Rev. A 66, 064702 (2002)], electron-hydrogen and electron-He(+) S-wave scattering phase shifts were calculated using the optical potential approach. This method is now extended to the singlet and triplet electron-H P-wave scattering in the elastic region. Phase shifts are calculated using Hylleraas-type correlation functions with up to 220 terms. Results are rigorous lower bounds to the exact phase shifts and they are compared to phase shifts obtained from previous calculations.

Bhatia, A. K.↗

Dibenzo-p-dioxins in the environment from ceramics and pottery produced from ball clay mined in the United States

Processed ball clay samples used in the production of ceramics and samples of the ceramic products were collected and analyzed for the presence and concentration of the 2,3,7,8-Cl substituted polychlorinated dibenzo-p-dioxins and -furans (PCDDs/PCDFs). The processed ball clay had average PCDD concentrations of 3.2 ng/g toxic equivalents, a congener profile, and isomer distribution consistent with those found previously in raw ball clay. The PCDF concentrations were below the average limit of detection (LOD) of 0.5 pg/g. The final fired ceramic products were found to be free of PCDDs/PCDFs at the LODs. A consideration of the conditions involved in the firing process suggests that the PCDDs, if not destroyed, may be released to the atmosphere and could represent an as yet unidentified source of dioxins to the environment. In addition, the PCDDs in clay dust generated during manufacturing operations may represent a potential occupational exposure.

Aluminum Silicates/chemistry↗

Experiences on p-Version Time-Discontinuous Galerkin's Method for Nonlinear Heat Transfer Analysis and Sensitivity Analysis

The focus of this research is on the development of analysis and sensitivity analysis equations for nonlinear, transient heat transfer problems modeled by p-version, time discontinuous finite element approximation. The resulting matrix equation of the state equation is simply in the form ofA(x)x = c, representing a single step, time marching scheme. The Newton-Raphson's method is used to solve the nonlinear equation. Examples are first provided to demonstrate the accuracy characteristics of the resultant finite element approximation. A direct differentiation approach is then used to compute the thermal sensitivities of a nonlinear heat transfer problem. The report shows that only minimal coding effort is required to enhance the analysis code with the sensitivity analysis capability.

Hou, Gene↗

Determination of 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and -furans at the part per trillion level in United States beef fat using high-resolution gas chromatography/high-resolution mass spectrometry

As part of the U.S. EPA Dioxin Reassessment Program, the 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and furans were measured at part per trillion (ppt) levels in beef fat collected from slaughter facilities in the United States. This is the first statistically designed national survey of these compounds in the U.S. beef supply. Analyte concentrations were determined by high-resolution gas chromatography/high-resolution mass spectrometry, using isotope dilution methodology. Method limits of detection on a whole weight basis were 0.05 ppt for TCDD and 0.10 ppt for TCDF, 0.50 ppt for the pentas (PeCDDs/PeCDFs)/hexas (HxCDDs/HxCDFs)/heptas (HpCDDs/HpCDFs), and 3.00 ppt for the octas (OCDD/OCDF). Method detection and quantitation limits were established on the basis of demonstrated performance criteria utilizing fortified samples rather than by conventional signal-to-noise or variability of response methods. The background subtraction procedures developed for this study minimized the likelihood of false positives and increased the confidence associated with reported values near the detection limits. Mean and median values for each of the 2,3,7,8-Cl-substituted dioxins and furans are reported, along with the supporting information required for their interpretation. The mean toxic equivalence values for the samples are 0.35 ppt (nondetects = 0) and 0.89 ppt (nondetects = 1/2 LOD).

Benzofurans/analysis↗

Evaluation of Gust and Draft Velocities from Flights of P-61C Airplanes within Thunderstorms August 21, 1946 to August 22, 1946 at Orlando, Florida

Tables I and II of this report summarize the gust and draft velocity data for thunderstorm flights 25 and 26 of August 21, 1946 and August 22, 1946, respectively. These dta were evaluated from records of NACA instruments installed in P-61C airplanes and are of the type presented in reference 1 for previous flights. Table III summarizes the readings of a milliammeter which was used in conjunction with other equipment to indicate ambient air temperature during thunderstorm surveys. These data were read from motion-picture records of the instrument and include all cases in which variations in the instrument indications were noted during the present flights.

Tolefson, H. B.↗

Evaluation of Gust and Draft Velocities from Flights of P-61C Airplanes within Thunderstorms. IV - July 19, 1946 to July 20, 1946 at Orlando, Florida: July 19, 1946 to July 20, 1946 at Orlando, Florida - Part 4

Summaries of the gust and draft velocities evaluated from acceleration and airspeed-altitude records taken by NACA instruments installed n P-61c airplanes participating in thunderstorm flights 12 and 13 of July 19, 1946, and July 20, 1946, respectively, are presented in tables I and II herein. These data are of the type presented in reference 1 for previous flights. Inspection of the motion picture records of the pilots' instrument panels for the present flights indicated that the milliameter connected to equipment for measuring ambient air temperature read zero throughout all traverses.

Tolefson, H. B.↗

Evaluation of Gust and Draft Velocities from Flights of P-61c Airplanes within Thunderstorms. III - July 12, 1946 to July 18, 1946 at Orlando, Florida: July 12, 1946 to July 18, 1946 at Orlando, Florida - Part 3

The gust and draft velocities evaluated from acceleration and airspeed-altitude records taken by NACA instruments installed in P-61c airplanes participating in thunderstorm flights 9, 10, and 11 of July 12, 1946, July 17, 1946, and July 18, 1946, respectively, are presented in references 1 and 2 for previous flights. In accordance with a recent discussion with a member of the U.S. Weather Bureau staff, motion-picture records of the pilots' instrument panels for the present flights were inspected to note variations in the readings of a milliammeter used in conjunction with other equipment to indicate ambient air temperature. The inspection indicated that the instrument read zero throughout all traverses.

Tolefson, H. B.↗