Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Other,ENG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Interferometers Characterization

Procedure and characterization result for two vibration insensitive phase shifting interferometers will be presented. Typical applications of the vibration insensitive interferometers include the testing of large astronomical primary mirrors with long radii of curvature in a severe vibration environment. The procedure list the steps for characterizing the two interferometers. The characterization compares the two interferometers and compares to its own specification.

Eng, Ron↗

AMSD Test Plan

The overall government plan to verify compliance of AMSD mirror systems to the specifications as given in the contract Statement of Work will be presented. The plan will address test requirements, test hardware, AMSD-XRCF interfacing, government vs contractor responsibilities, tests to be carried out, test conduction, and test data reduction & reporting. Issues regarding input to the plan and schedule of plan milestones will also be addressed.

Hadaway, James↗

MSFC Test Results for Selected Mirrors: Brush-Wellman/Goodrich 0.5 meter Joined-Beryllium Mirror; IABG 0.5 meter C/SiC Mirror; Xinetics 0.5 meter SiC Mirror; and Kodak 0.23 meter SiO2 Mirror

The results of cryo tests performed at the XRCF on the above mirrors will be presented. Each mirror was tested from room-temperature to around 30 K. The first three were tested together on a 3-mirror stand in the large chamber using the PhaseCam interferometer, while the Kodak mirror was tested in the small chamber using the EPI interferometer.

Hadaway, James↗

4D PhaseCam(Trade Mark) Capabilities: Modal Analysis and Multiple-Wavelength Mirror Phasing

The PhaseCam is a dynamic phase shifting interferometer system manufactured by 4D Technology Corporation that is capable of very fast data acquisition. This rapid acquisition extends the capability of conventional interferometry to enable measurement in unstable environments, the generation of phase movies of surface shape and to facilitate modal analysis of structures. The PhaseCam hardware and software have been modified for MSFC to include synchronous modal optical measurement and analysis. These modifications will be discussed and data presented. The dynamic range of a phase shifting measurement is limited by local slope and pixel sampling to lambda/4 wave steps. Two-wavelength techniques can increase the effective measurement wavelength from microns to tens of centimeters and permit the phasing of mirror segments. A two wavelength PhaseCam will be discussed and measurement results presented.

Millerd, James E.↗

Leica Absolute Distance Meter

The principle of operation and measured accuracy of the ADM will be presented. Results of the Acceptance Test will be reported.

Hadaway, James↗

MSFC/Ball Space-Act Test Results of SBMD

The results of two cryo tests of the SBMD that were funded by Ball Aerospace through a Space-Act Agreement with MSFC will be discussed. These tests followed the formal completion of the SBMD program. The PhaseCam interferometer, rather than the Wavescope Shack-Hartmann sensor, was used during these tests.

Hadaway, James↗

AMSD Reaction Structure Cryo Deformation Test Plan

The method developed for measuring both in-plane & out-of-plane cryo deformations of AMSD reaction structures at the XRCF will be presented. For in-plane measurements, a theodolite is used to track the positions of several (up to ten) targets on the reaction structure. For out-of-plane measurements, the Leica ADM is used to measure the change in distance to several (up to ten) corner cubes attached to the reaction structure.

Eng, Ron↗

AMSD Figure Certification Plan

The method planned for the surface figure error measurement of the AMSDs at the XRCF will be discussed. Alignment, surface figure measurement, gravity effects, vibration & temperature environment effects, total error analysis, and data output will be discussed.

Reardon, Pat↗

Interferometer for Testing in Vibration Environments

Temporal phase shifting interferometers require a stable environment during the data acquisition, so that well controlled phase steps can be introduced between successively acquired interferograms. In contrast, single-frame interferometers need to acquire only one interferogram to provide a phase map with very good precision at high spatial resolution. Thus these interferometers are well suited for the interferometric testing of large optics with long radius of curvature for which vibration isolation is difficult, eg. testing astronomical telescope mirrors in a test tower, or testing space optics inside a cryogenic vacuum chamber. This paper describes the Instantaneous Phase Interferometer (IPI) by ADE Phase Shift, together with measurement results at NASA. The IPI consists of a polarization Twyman-Green interferometer operating at 632.8 nm, with single-frame data acquisition based on a spatial carrier technique. The spatial carrier fringes are generated by introducing large amount of tilt between the test beam and the reference beam. The phase information of the optical surface under test is encoded in the straightness of the interference fringes, which can be detected in a single frame with spatial sampling of 1000 x 1000 pixels. Measurements taken at the NASA Marshall Space Flight Cater in support of the characterization of developmental optics for the Next Generation Space Telescope are presented. Such tests consist of a mirror placed inside a cryogenic vacuum chamber, with the IPI placed outside the test chamber without any additional vibration isolation.

Eng, Ron↗

Helium Cryo Testing of a SLMS(TM) (Silicon Lightweight Mirrors) Athermal Optical Assembly

SLMS (TM) a thermal technology has been demonstrated in the small 4-foot helium cryogenic test chamber located at the NASA/MSFC X-Ray Calibration Facility (XRCF). A SLMS (TM) Ultraviolet Demonstrator Mirror (UVDM) produced by Schafer under a NASA/MSFC Phase I SBIR was helium cryo tested both free standing and bonded to a Schafer designed prototype carbon fiber reinforced silicon carbide (Cesic) mount. Surface figure data was obtained with a test measurement system that featured an Instantaneous Phase Interferometer (IPI) by ADE Phase Shift. The test measurement system s minimum resolvable differential figure deformation and possible contributions from test chamber ambient to cryo window deformation are under investigation. The free standing results showed differential figure deformation of 10.4 nm rms from 295K to 27K and 3.9 nm rms after one cryo cycle. The surface figure of the UVDM degraded by lambda/70 rms HeNe once it was bonded to the prototype Cesic mount. The change was due to a small astigmatic aberration in the rototype Cesic mount due to lack of finish machining and not the bonding technique. This effect was seen in SLMST (TM) optical assembly results, which showed differential figure deformation of 46.5 nm rms from 294K to 27K, 42.9 nm rms from 294K to 77K, 28.0 nm rms from 294K to 193K and 6.2 nm rms after one cryo cycle.

Jacoby, Marc T.↗

Data Access Tools And Services At The Goddard Distributed Active Archive Center (GDAAC)

As one of the largest providers of Earth Science data from the Earth Observing System, GDAAC provides the latest data from the Moderate Resolution Imaging Spectroradiometer (MODIS), Atmospheric Infrared Sounder (AIRS), Solar Radiation and Climate Experiment (SORCE) data products via GDAAC's data pool (50TB of disk cache). In order to make this huge volume of data more accessible to the public and science communities, the GDAAC offers multiple data access tools and services: Open Source Project for Network Data Access Protocol (OPeNDAP), Grid Analysis and Display System (GrADS/DODS) (GDS), Live Access Server (LAS), OpenGlS Web Map Server (WMS) and Near Archive Data Mining (NADM). The objective is to assist users in retrieving electronically a smaller, usable portion of data for further analysis. The OPeNDAP server, formerly known as the Distributed Oceanographic Data System (DODS), allows the user to retrieve data without worrying about the data format. OPeNDAP is capable of server-side subsetting of HDF, HDF-EOS, netCDF, JGOFS, ASCII, DSP, FITS and binary data formats. The GrADS/DODS server is capable of serving the same data formats as OPeNDAP. GDS has an additional feature of server-side analysis. Users can analyze the data on the server there by decreasing the computational load on their client's system. The LAS is a flexible server that allows user to graphically visualize data on the fly, to request different file formats and to compare variables from distributed locations. Users of LAS have options to use other available graphics viewers such as IDL, Matlab or GrADS. WMS is based on the OPeNDAP for serving geospatial information. WMS supports OpenGlS protocol to provide data in GIs-friendly formats for analysis and visualization. NADM is another access to the GDAAC's data pool. NADM gives users the capability to use a browser to upload their C, FORTRAN or IDL algorithms, test the algorithms, and mine data in the data pool. With NADM, the GDAAC provides an environment physically close to the data source. NADM will benefit users with mining or offer data reduction algorithms by reducing large volumes of data before transmission over the network to the user.

Pham, Long↗

A New Oxygen Barometer for Solar System Basaltic Glasses Based on Vanadium Valence

The determination of oxidation conditions for basaltic magmas derived by the melting of planetary mantles is critical to our understanding of the nature and evolution of planetary interiors. Yet, these determinations are compromised in terrestrial and especially extraterrestrial basalts by our analytical and computational methods for estimating oxygen fugacity (fO2). For example, mineralogical barometers (1, 2) can be reduced in effectiveness by subsolidus re-equilibration of mineral assemblages, inversion of mineralogical data to melt characteristics, and deviations of the natural mineral compositions from ideal thermodynamic parameters.

Karner, J. M.↗

Lessons Learned During Cryogenic Optical Testing of the Advanced Mirror System Demonstrators (AMSDs)

Optical testing in a cryogenic environment presents a host of challenges above and beyond those encountered during room temperature testing. The Advanced Mirror System Demonstrators (AMSDs) are 1.4 m diameter, ultra light-weight (<20 kg/mA2), off-axis parabolic segments. They are required to have 250 nm PV & 50 nm RMS surface figure error or less at 35 K. An optical testing system, consisting of an Instantaneous Phase Interferometer (PI), a diffractive null corrector (DNC), and an Absolute Distance Meter (ADM), was used to measure the surface figure & radius-of-curvature of these mirrors at the operational temperature within the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The Ah4SD program was designed to improve the technology related to the design, fabrication, & testing of such mirrors in support of NASA s James Webb Space Telescope (JWST). This paper will describe the lessons learned during preparation & cryogenic testing of the AMSDs.

Hadaway, James↗

Lightning Instrumentation at KSC

This report summarizes lightning phenomena with a brief explanation of lightning generation and lightning activity as related to KSC. An analysis of the instrumentation used at launching Pads 39 A&B for measurements of lightning effects is included with alternatives and recommendations to improve the protection system and upgrade the actual instrumentation system. An architecture for a new data collection system to replace the present one is also included. A novel architecture to obtain lightning current information from several sensors using only one high speed recording channel while monitoring all sensors to replace the actual manual lightning current recorders and a novel device for the protection system are described.

Colon, Jose L.↗

Poco Graphite Inc. SuperSiC 0.25m Mirror Cryogenic Test Result

SuperSiC, a low areal density material, developed by POCO Graphite, have been used as mirror substrate for high energy lasers, laser radar systems, surveillance, telescopes, scan mirrors and satellites. SuperSiC has excellent thermal properties and cryogenic stability. It exhibits exceptional polishability for reflective optics with high strength, stiffness, and excellent thermal conductivity. A lightweighted 0.2-diameter polished SuperSic mirror was tested at cryogenic temperature at NASMSFC. Optical test results showed 6nm cry0 deformation from ambient to 30 degrees Kelvin and little to no change in its surface figure due to cry0 cycling.

Eng, Ron↗

Cryogenic Test Results of Hextek Mirror

A 250 mm diameter lightweight borosilicate mirror has been interferometrically tested from room-temperature down to 30 K at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The minor blank was manufactured by Hextek Corporation using a high-temperature gas fusion process and was then polished at MSFC. It is a sandwich-type mirror consisting of a thin face-sheet (approx.1.5 mm thick), a core structure (20 mm thick, approx.43 mm diameter cells, & 0.5-1.2 mm thick walls), and a thin back-sheet (3 mm thick). The mirror has a 2500 mm spherical radius-of- curvature @/lo). The areal density is 14 kg/sq m. The mirror was tested in the 1 m x 2 m chamber using an Instantaneous Phase Interferometer (PI) from ADE Phase Shift Technologies. The mirror was tested twice. The first test measured the change in surface figure from ambient to 30 K and the repeatability of the change. An attempt was then made by QED Technologies to cryo-figure the mirror using magnetorheological finishing. The second test measured the effectiveness of the cryo- figuring. This paper will describe the test goals, the test instrumentation, and the test results for these cryogenic tests.

Hadaway, James↗

Glutamine synthetase immunoreactivity is present in oligodendroglia of various regions of the central nervous system

Glutamine synthetase immunoreactive oligodendrocytes were identified in the cerebral cortex, cerebellum, brain stem, and spinal cord. They were mostly confined to the gray matter, particularly close to neurons and processes. The white matter showed few immunoreactive oligodendroglia. It was suggested that some type of oligodendrocytes, specially those in perineuronal location, might fulfill a functional role more akin to astrocytes than to the normally myelinating oligodendroglia.

Oligodendroglia/enzymology↗

Measurements of Man-Made Spectrum Noise Floor

This report consolidates research carried out at Clemson University and Stanford University where a series of measurements were undertaken to identify the man-made radiation present in four bands used by rather different services, namely, L1 Band (1563.42 1587.42 MHz), the Unified S-Band (2025 2110 MHz), the 2.4 GHz Industrial, Scientific and Medical (ISM) Band (2400 2482.50 MHz), and the 23.6-24.0 GHz Passive Sensing Band. Results show that there were distinctive differences in the measurement data in the frequency bands, which should be expected based on the function/regulation associated with each. The GPS L1 Band had little to none terrestrial man-made sources, but the ISM 2.4 GHz Band had a large number of man-made sources regardless of the site and the time. The Unified S Band showed mixed results depending on the sites. The Passive Sensing Band does not contain appreciable man-made radiation.

FROM↗