Signatures of nonthermal carriers in nonlinear photoluminescence

Ultrafast light emission from plasmonic nanostructures provides a sensitive probe of the energetic electrons generated by intense optical excitation. The way this emission scales with excitation intensity has long been read through the lens of heated electron populations at an elevated temperature, yet this picture cannot reconcile the variety of behaviors seen across different materials and experiments. We argue that transient nonthermal electrons play a far larger role than has been appreciated. We present a unified description that reproduces emission behavior across diverse systems and outline experiments needed to resolve their signatures.

nanoscale materials↗

Accurate and confident prediction of electron beam longitudinal properties using spectral virtual diagnostics

Abstract Longitudinal phase space (LPS) provides a critical information about electron beam dynamics for various scientific applications. For example, it can give insight into the high-brightness X-ray radiation from a free electron laser. Existing diagnostics are invasive, and often times cannot operate at the required resolution. In this work we present a machine learning-based Virtual Diagnostic (VD) tool to accurately predict the LPS for every shot using spectral information collected non-destructively from the radiation of relativistic electron beam. We demonstrate the tool’s accuracy for three different case studies with experimental or simulated data. For each case, we introduce a method to increase the confidence in the VD tool. We anticipate that spectral VD would improve the setup and understanding of experimental configurations at DOE’s user facilities as well as data sorting and analysis. The spectral VD can provide confident knowledge of the longitudinal bunch properties at the next generation of high-repetition rate linear accelerators while reducing the load on data storage, readout and streaming requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

M-STAR: Magnetism second target advanced reflectometer at the Spallation Neutron Source

M-STAR is a next generation polarized neutron reflectometer with advanced capabilities. A new focusing guide concept is optimized for samples with dimensions down to a millimeter range. A proposed hybrid pulse-skipping chopper will enable experiments at constant geometry at one incident angle in a broad range of wavevector transfer Q up to 0.3 A –1 for specular, off-specular, and GISANS measurements. M-STAR will empower nanoscience and spintronics studies routinely on small samples (~2 × 2 mm 2 ) and of atomic-scale thickness using versatile experimental conditions of magnetic and/or electric fields, light, and temperature applied in situ to novel complex device-like nanosystems with multiple buried interfaces. M-STAR will enable improved grazing incidence diffraction measurements, as a surface-sensitive depth-resolved probe of, e.g., the out-of-plane component of atomic magnetic moments in ferromagnetic, antiferromagnetic, and more complex structures as well as in-plane atomic-scale structures inaccessible with contemporary diffractometry and reflectometry. New horizons will be opened by the development of an option to probe near-surface dynamics with inelastic grazing incidence scattering in the time-of-flight mode. These novel options in combination with ideally matched parameters of the second target station will place M-STAR in the world’s leading position for high resolution polarized reflectometry.

47 OTHER INSTRUMENTATION↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Characterization of the upgraded single-line-of-sight time-resolved x-ray imager using short-pulse visible and UV lasers

The single-line-of-sight time-resolved x-ray imager (SLOS-TRXI), a fast-gated x-ray imager used for capturing x-ray self-emission in inertial confinement fusion experiments on OMEGA, has been upgraded and characterized. SLOS-TRXI combines an electron-dilation imager and a hybrid complementary metal–oxide–semiconductor (hCMOS) sensor to capture multiple gated frames on a single line of sight with a temporal resolution of ~40 ps and a spatial resolution of 10 µm. The original hCMOS sensor with four frames was replaced with a newer-generation hCMOS sensor having eight frames. Gate characterizations of both the sensor and the entire SLOS-TRXI diagnostic were performed using ~10-ps FWHM visible (2ω) and UV (4ω) short-pulse lasers, respectively. A stepped echelon was used to generate a train of five UV laser pulses having an interpulse separation of 30 ± 3 ps. Characterization results of the hCMOS gating (2.28 ± 0.02-ns FWHM on average) and a temporal resolution of the upgraded SLOS-TRXI (34 ± 4-ps FWHM on average) are presented. A temporal magnification for the electron-dilation imager between 40 and 60 was inferred from the characterization results. Furthermore, the spatial resolution of the upgraded SLOS-TRXI remains the same in light of this work.

47 OTHER INSTRUMENTATION↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗

A Concept of a Convection–Cloud Chamber to Study Aerosol–Cloud–Drizzle Interactions

Understanding and quantifying the full chain of processes from aerosol activation to drizzle formation, and the associated feedbacks to the aerosol chemical and physical properties, all within a turbulent cloud are some of the toughest challenges in atmospheric chemistry and physics and are keys to the cloud–precipitation puzzle. This paper describes a concept for a new type of research facility consisting of a cloud chamber plus associated instrumentation and computational models, to explore aerosol–cloud interactions and processing, cloud optical properties, entrainment–cloud interactions, and quantitative assessment of drizzle onset. The envisioned design is for a 3 m × 3 m × 9 m chamber, such that the height is sufficient to achieve long lifetimes for aerosol processing and for significant drizzle growth by collision and coalescence. A suite of computational tools for simulating microphysical properties in the chamber provides a digital twin for designing the chamber and a range of example experiments. Theory and test results from novel remote sensing systems for exploring chemical and physical interactions and evolution of aerosols, cloud droplets, and drizzle within turbulent clouds are described. Testing of technology needed for the operation of a large-volume chamber, including aerosol generation methods and novel materials for water vapor boundary conditions, is described. Simulations suggest that spatially uniform turbulence and microphysical properties can be sustained in a steady state, with reasonable aerosol and water vapor fluxes, and that substantial drizzle can be produced through collision and coalescence of cloud droplets. Remaining challenges for more detailed engineering design and a discussion of possible first-light experiments are described.

54 ENVIRONMENTAL SCIENCES↗

Luminescent Materials for the Detection of Economically Critical Metals in Harsh Environments

Renewable energy technologies used for electric vehicles and wind turbines are heavily reliant upon metals, such as rare earth elements, cobalt, lithium, and nickel. Indeed, there are 50 minerals that are currently considered “economically critical” by the 2022 United States Geological Survey. With anticipated global adoption of renewable energy technologies, producing sufficient metals to meet this demand presents a significant challenge, particularly due to the current monopolistic market for many of these metals. The production of metals from unconventional sources, such as coal utilization byproducts, is one of many promising strategies to boost domestic supply. However, sensitive, rapid, and inexpensive characterization technologies are needed to minimize production costs associated with metals prospecting and processing. Photoluminescence-based sensing techniques are particularly intriguing due to their potential for low cost and portability, coupled with high sensitivity and selectivity. This presentation focuses on the development of high-performance sensing materials for a range of critical metals, including metal-organic frameworks capable of sensitizing detection of parts-per-billion concentrations of six different rare earth elements, nanoparticles that can detect down to 600 parts-per-billion levels of cobalt, and thin films that sense aluminum down to 120 parts-per-billion. These materials are highly selective, capable of withstanding low pH conditions, and provide a response within minutes. Importantly, each sensing material is integrated with a custom-built, fully portable fiber-optic spectrometer for potential field deployment, providing significant cost savings over commercial instruments, along with potential advantages such as material regeneration for use across multiple sensing cycles and solvent removal for enhanced emission signal. These results highlight the exciting potential of luminescence platforms as cost-effective alternatives for metals characterization.

Crawford, Scott↗

Initial Feasibility Assessment and Broader Strategy Development for Fiber Integration via Advanced Manufacturing

Structural health monitoring is critical for ensuring the operational safety and cost-competitiveness of the developing advanced reactor designs. The extreme operational envelopes of these advanced architectures, having operating temperatures ranging 400°C–1,000°C and heightened displacement damage doses, render conventional commercially available piezoelectric transducers and resistive strain gauges unviable. Optical fiber sensors present an attractive solution for advanced radiation-hardened instrumentation due to their high thermal stability and distributed sensing capabilities. However, their deployment in embedded applications can be hindered by the severe thermomechanical strain driven by the coefficient of thermal expansion mismatch between fused silica glass and structural metal alloys like stainless steel (e.g., SS316L).

36 MATERIALS SCIENCE↗

Distributed Acoustic Sensing Based on Coherent Microwave Photonics Interferometry

A microwave photonics method has been developed for measuring distributed acoustic signals. This method uses microwave-modulated low coherence light as a probe to interrogate distributed in-fiber interferometers, which are used to measure acoustic-induced strain. By sweeping the microwave frequency at a constant rate, the acoustic signals are encoded into the complex microwave spectrum. The microwave spectrum is transformed into the joint time–frequency domain and further processed to obtain the distributed acoustic signals. The method is first evaluated using an intrinsic Fabry Perot interferometer (IFPI). Acoustic signals of frequency up to 15.6 kHz were detected. The method was further demonstrated using an array of in-fiber weak reflectors and an external Michelson interferometer. Two piezoceramic cylinders (PCCs) driven at frequencies of 1700 Hz and 3430 Hz were used as acoustic sources. The experiment results show that the sensing system can locate multiple acoustic sources. The system resolves 20 nε when the spatial resolution is 5 cm. The recovered acoustic signals match the excitation signals in frequency, amplitude, and phase, indicating an excellent potential for distributed acoustic sensing (DAS).

47 OTHER INSTRUMENTATION↗

Clustering of LRGs in the DECaLS DR8 Footprint: Distance Constraints from Baryon Acoustic Oscillations Using Photometric Redshifts

A photometric redshift sample of luminous red galaxies (LRGs) obtained from the DECam Legacy Survey (DECaLS) is analyzed to probe cosmic distances by exploiting the wedge approach of the two-point correlation function. Although the cosmological information is highly contaminated by the uncertainties existing in the photometric redshifts from the galaxy map, an angular diameter distance can be probed at the perpendicular configuration in which the measured correlation function is minimally contaminated. An ensemble of wedged correlation functions selected up to a given threshold based on having the least contamination was studied in previous work (Sridhar & Song 2019) using simulations, and the extracted cosmological information was unbiased within this threshold. Furthermore, we apply the same methodology for analyzing the LRG sample from DECaLS, which will provide the optical imaging for targeting two-thirds of the Dark Energy Spectroscopic Instrument footprint and measure the angular diameter distances at z = 0.69 and z = 0.87 to be D A (0.697) = (1529 ± 73 Mpe)(r d /r d.fid ) and D A (0.874) = (1674 ± 102 Mpe)(r d /r d.fid ) with a fractional error of 4.77% and 6.09%, respectively. We obtain a value of H 0 = 66.58 ± 5.31 km s -1 Mpc -1 , which supports the H 0 measured by all other baryon acoustic oscillation results and is consistent with the ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards the development of resonantly enhanced laser-based diagnostics for molten salt reactor safeguards

The adoption of Generation IV molten salt reactors (MSRs) depends on the ability to implement compatible monitoring instrumentation to ensure adherence to nuclear safeguards. This task is nontrivial due to the high temperature, reactive, and chemically complex fuel and coolant components contained within these systems. Optical spectroscopy techniques such as laser-induced fluorescence (LIF) and laser-induced breakdown spectroscopy (LIBS) are candidates for monitoring instrumentation. They offer many advantages for continuous monitoring, including the ability to operate at a standoff and compatibility with liquid-phase analytes. We discuss the use of LIF for the detection of Nd, a common fission fragment, within a liquid matrix. Results show that for NdCl3 dissolved in water, the Nd I 492.45 nm resonant transition is detectable without the need to induce a plasma and that the fluorescence emission can be separated in the time domain from the laser scatter signal. Additionally, we present a setup and preliminary results for measurements of solid Nd and U using resonant LIBS. The results demonstrate element-selective measurement capabilities and provide the foundational data necessary to continue the development of laser-based MSR diagnostics. This work also helps address gaps in the literature regarding energy level assignments of Nd.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Second Target Station (STS) Project: PIONEER Technical Report

PIONEER is a time-of-flight single-crystal neutron diffractometer at the Second Target Station (STS), aiming at providing the world-leading capability to measure tiny crystals (~0.001 mm 3 , i.e., X-ray diffraction size), ultra-thin epitaxial films (~10 nm thicknesses), and weak structural transitions and complex magnetism. The instrument will take advantage of STS source characteristics and utilize advancements in neutron optics to largely reduce the sample-volume requirement for single-crystal neutron diffraction. PIONEER will have a high-flux mode with multiple beam size options to improve the signal-to-background ratio in various sample environments. It will also provide a high Q-resolution mode by limiting beam divergence to study periodically modulated structures with characteristic lengths no less than 100 Å. Furthermore, it supports half-polarized neutron diffraction for investigating complex magnetism and local susceptibility. This report first overviews the proposed science case and the derived requirement. And then, the chosen technical solutions and expected performance will be described.

36 MATERIALS SCIENCE↗

Thin film lithium niobate electric field sensors

We present our results for using thin film lithium niobate devices for electric field sensing applications. Micro-ring modulator and Mach–Zehnder modulator-based electric field sensors are demonstrated. Micro-ring resonator sensors can be used for low frequency (up to several GHz) electric field sensing applications and achieve a high sensitivity of 80 mV/(m Hz 1/2 ) with a very compact size of 300 μm, as limited by the intensity and phase noise of the used distributed feedback laser. A measurement bandwidth of 2.5 GHz is measured for these sensors and is limited by the detector bandwidth. Alternatively, Mach–Zehnder modulators allow for perfect phase matching between the radio frequency signals and optical signals, and they can be used for electric field sensing up to several THz. A sensitivity of 2.2 V/(m Hz 1/2 ) was obtained using our Mach–Zehnder electric field sensor with an interaction length of 600 μm. The Mach–Zehnder sensor can sense electric fields with frequencies reaching 0.6 THz based on the calculated results.

47 OTHER INSTRUMENTATION↗

The Galaxy–Halo Connection of DESI Luminous Red Galaxies with Subhalo Abundance Matching

Abstract We use subhalo abundance and age distribution matching to create magnitude-limited mock galaxy catalogs at z ∼ 0.43, 0.52, and 0.63 with z -band and 3.4 μ m W 1-band absolute magnitudes and r − z and r − W 1 colors. From these magnitude-limited mocks, we select mock luminous red galaxy (LRG) samples according to the ( r − z )-based (optical) and ( r − W 1)-based (infrared) selection criteria for the LRG sample of the Dark Energy Spectroscopic Instrument (DESI) survey. Our models reproduce the number densities, luminosity functions, color distributions, and projected clustering of the DESI Legacy Surveys that are the basis for DESI LRG target selection. We predict the halo occupation statistics of both optical and IR DESI LRGs at fixed cosmology and assess the differences between the two LRG samples. We find that IR-based SHAM modeling represents the differences between the optical and IR LRG populations better than using the z band and that age distribution matching overpredicts the clustering of LRGs, implying that galaxy color is uncorrelated with halo age in the LRG regime. Both the optical and IR DESI LRG target selections exclude some of the most luminous galaxies that would appear to be LRGs based on their position on the red sequence in optical color–magnitude space. Both selections also yield populations with a nontrivial LRG–halo connection that does not reach unity for the most massive halos. We find that the IR selection achieves greater completeness (≳90%) than the optical selection across all redshift bins studied.

Berti, Angela M. (ORCID:0000000335826649)↗