Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Measured Performance of a Low Temperature Air Source Heat Pump

A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor 'boosted heat pump' technology. The Low Temperature Heat Pumpsystem operates with four increasing levels of capacity (heat output) as the outdoor temperature drops. The system was shown to select capacity correctly, supplying the appropriate amount of heat to the house across the full range of outdoor temperatures. The system's Coefficient of Performance (Seasonal COP, or SCOP) over two entire winters was calculated, based on measured data, to be 3.29over the first winter and 2.68 over the second winter. A second seasonal efficiency calculation by a different method yielded a SCOP of 2.78 for the first winter and 2.83 for the second winter. This second seasonal efficiency calculation was determined by comparing measured heat pump energy use to the in situ energy use with resistance heat alone. This method is the ratio of the slopes of thedaily energy use load lines.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study for the ARRA-funded Ground Source Heat Pump (GSHP) Demonstration at Wilders Grove Solid Waste Service Center in Raleigh, NC

High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a distributed GSHP system for providing all the space conditioning, outdoor air ventilation, and 100% domestic hot water to the Wilders Grove Solid Waste Service Center of City of Raleigh, North Carolina. This case study is based on the analysis of measured performance data, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning and outdoor air ventilation as the demonstrated GSHP system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GSHP system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation and improving the operational efficiency of the demonstrated GSHP system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of concentrator photovoltaic solar cell performance through photonic engineering

The goal of this program was to incorporate two new and innovative design concepts into the design and production of CPV cells that have near zero added cost, yet significantly increase the operational efficiency of CPV modules. The program focused developing luminescent coupling effects and radiative cooling layers to increase efficiency and suppress CPV module power losses due to spectral variations and heating. The major results of the program were: 1) The optics of three commercial refractive (Fresnel) concentrators were characterized and prevent application of radiative cooling concepts due to strong mid-IR absorption (4-12µm) required to effectively radiate blackbody radiation from the cells and provide cooling. Investigation of alternative materials for the concentrator lenses produced only undesirable options—materials with reasonable mid-IR transmission for cooling only had about 30-40 visible transmission, thus reducing incident sunlight by >50%. While our investigation was somewhat limited, our work suggests that the only viable concentrator system that can incorporate radiative cooling utilizes reflective optics. 2) With limited ability to test high concentration CPV cells (requires outdoor testing), we acquired both semi-crystalline and crystalline Si cells and tested them in our outdoor facility and demonstrated 4°C cooling using a simple silica layer coating on the cells. 3) Characterizing Si cells in the IR associated with radiative cooling, we observed very significant near-IR absorption that increases the cell operating temperature by a similar amount, 4-5°C. By appropriate surface layer design, one can produce a layer that is highly reflective in the near-IR (1.5-4µm) and highly emissive in the mid-IR (5-15µm), thus reducing cell operational temperature by 10°C and increasing efficiency by ~1% absolute. The radiative cooling effect in c-Si solar cells might be further improved by providing a higher thermal conductive elastomer for securing the cover glass on top of the AR-coating. Since it was never imagined that the front surface would provide any cooling for solar cells, thermal conductivity of this elastomer was never a design consideration, but, improving the conductivity could decrease cell temperature by another 3-4°C. The combined effect could be an ~1.5% absolute increase in cell and module efficiency, a very significant improvement. 4) Developed a numerical model to explore dependence of luminescent coupling efficiency over a broad range of operating conditions. We developed a novel method and facility to experimentally measure the luminescent coupling that can be used to confirm the dependence of luminescent coupling on multi-junction cell design parameters.

14 SOLAR ENERGY↗

Development of a Green Parabolic Trough Collector

This report describes in detail a research project that assesses the potential of a parabolic trough solar collector with a lumber construction to meet ambitious performance, cost, and durability goals. Instead of exploring lumber as a general question for solar collectors, the project focuses on the design optimization, laboratory testing, outdoor testing, and economic modeling of a particular scale of parabolic trough, namely, the 6m aperture and 12m long module that has become the standard in the utility-scale power plant market. As will be appreciated in the report, it is also a scale that matches well the capabilities of lumber as a structural material and the commonly available cross sections. The design and its analysis extend far beyond traditional considerations for wooden structures in the built environment, and includes a computationally efficient coupled structural-optical simulation and the empirical characterization of joint stiffness at small deformations. Laboratory testing is used to characterize cyclic joint behavior, accelerated weathering, and to validate the simulation used as the basis for building a full-scale prototype. The construction and outdoor testing of this prototype is described. A total installed cost model of the collector is presented and the impact of the cost is seen in the context of a full plant techno-economic model. The results of this model in combination with the experience with the first prototype suggest that with improvements to the design and assembly process, this collector type has the potential to lower the levelized cost of heat for industrial solar steam plants used for process heating or cogeneration.

14 SOLAR ENERGY↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dual-Zone Solar Control Indoor Shade: Demonstration at the Ronald V. Dellums Federal Building and U.S. Courthouse, 1301 Clay Street, Oakland, California and the Lawrence Berkeley National Laboratory Advanced Windows Testbed, Berkeley, California

Standard window shades are used to control sunlight, glare, window heat gains, and daylight. The challenge with conventional shades is that once the shades are lowered to reduce discomfort, daylight is reduced, which, in turn, increases the need for electric lighting. View is also obstructed, reducing the occupants’ connection to the outdoors. The strategy of subdividing the window wall and admitting daylight from above and controlling sunlight and view through the lower aperture can yield significant energy and peak demand savings over conventional shading systems, and improve the daylight quality of the indoor environment. This study evaluated a dual zone solar control (DZSC) shade with an upper, automated, horizontal, venetian blind with concave-up, matte white slats and a lower, manually operated, roller shade made of a transparent, reflective film. The automatic controls were designed to adjust the upper slat angle to maximize daylight to the room interior. The lower shade, when lowered, provided an unobstructed view to the outdoors. For the qualitative analysis, the DZSC shades were installed on windows in the southeast half of one floor in the Ronald V. Dellums Federal Building and U.S. Courthouse or hereafter referred to as the Oakland Federal Building (OFB) in Oakland, California. The position of the DZSC shades were observed and recorded periodically. Surveys were issued to occupants in the private offices and open plan workstations affected by the shades. For the quantitative analysis, the DZSC shades were installed in the south-facing windows of thermally isolated, fully instrumented, test chambers in the Advanced Windows Testbed at the Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California. Measurements of window heat loads, daylight illuminance and environmental conditions related to visual and thermal comfort were collected over a six-month, solstice-to-solstice period. The performance of the DZSC shade was compared to fabric roller shades and venetian blinds since these are the two most common types of shades used in both commercial and Federal buildings. Several DZSC design permutations were evaluated: 1) manual or automated control of the upper louver system (“man” or “auto”) and 2) tinted or silvered reflective film for the lower shade (“Gray-Gray (GG)” or “Gray-Silver (GS)”1). The automated, reflective shade (auto-GS) reduced dimmable fluorescent lighting energy use by 51% and window cooling load by 13-15% compared to a conventional fabric roller shade with dual-pane, spectrally selective, low-e windows during the summer period (winter period was not measured). Qualitative analysis revealed that the auto-GS shade was preferred by 80% of the survey respondents compared to the existing vertical fabric blinds with single-pane, tinted windows in the occupied building. Survey results indicated that visual discomfort was reduced and thermal discomfort was also reduced during warm or hot weather. Occupants expressed greater satisfaction with the unobstructed view. Installation and commissioning of the DZSC shades was fairly straightforward with some minor problems due to inadequate installation instructions and improper wiring. A few occupants expressed dissatisfaction with the automatic controls for the upper louvers due to visual discomfort, erroneous control, and motor noise.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Atmospheric CO 2 Capture and Membrane Delivery (Final Report)

Motivation: A major bottleneck for growing microalgae as a sustainable alternative to fossil carbon in economically producing fuels and chemical products is the cost of delivering CO 2 in sufficient concentrations for it not to limit growth. This project sought to develop and integrate two innovative technologies for capturing and concentrating CO 2 from air and delivering it to microalgae with high efficiency into an Atmospheric CO 2 Enrichment and Delivery (ACED) system. The CO 2 capture technology is based on moisture swing sorption (MSS), where specialized resin materials selectively capture CO 2 when dry and release it when wet into a confined space where the concentration can be increased up to 500-fold. The CO 2 -delivery technology is based on membrane carbonation (MC), which uses hollow fiber membranes that allow CO 2 to diffuse into the algae-containing liquid without forming bubbles, achieving nearly 100% delivery efficiency. Work completed: 1. Subsystem design, construction, and characterization [Months 1-6]. ACED integration requirements were defined; prototype MSS and MC sub-systems were constructed to conform to these requirements and characterized independently. 2. Subsystem optimization and evaluation [Months 7-12]. An iterative process of operating and upgrading each subsystem at lab scale, leading to compatibility at full integration. 3. System Integration with open raceway, testing, and modeling [Months 13-24]. Operation and testing of the integrated ACED system in an open raceway pond and modeling. Broader impacts: The ACED research program added to our understanding of 1) MC technology’s (i.e., hollow fiber membranes) utility for transferring pure CO 2 and CO 2 gas mixtures into microlagal cultures in laboratory and outdoor environments, 2) the first-of-a-kind MSS technology to capture CO 2 from ambient outdoor air, and 3) methods for storing captured CO 2 in carbonate/bicarbonate brines from which the CO 2 can be retrieved at high concentration (> 90%). Near-term commercial opportunities were outlined for the MC technology for small scale algae cultivation with high CO 2 costs (> $100/ton) and larger scale operators with continued development. This will help reduce costs for producing sustainable fuels and products and reduce cost for microalgal research for developing new applications. Research areas were identified for MSS technology to achieve cost competitive CO 2 produced from ambient air ($100/ton) as a means for closing the carbon cycle to make products from atmospheric CO 2 instead of fossil fuels and remove CO 2 from air to mitigate climate change.

09 BIOMASS FUELS↗

Evaluation of High Rotor Pole Switched Reluctance Motors to Control Condenser Fans in a Commercial Refrigeration System

A high rotor pole switched reluctance motor (HRSRM) designed by Software Motor Corporation was evaluated for use as a condenser fan motor due to its reported high motor efficiency over a broad range of speeds and added advanced control potential. The project was split into two phases; the first of which was to determine the direct energy savings due to the increased motor efficiency, the second was to leverage the additional benefits of the energy efficiency measure (EEM) to create additional energy savings. This report only discusses results from the first phase of the project. Nine 1.5hp HRSRMs were installed parallel to the same number of legacy induction motors of a supermarket commercial refrigeration system located in Lakeside, Colorado. At this site, the 1.5 hp legacy motors had historically adjusted condenser fan speed from 200-870 rpm based on outdoor air temperature and compressor discharge pressure. This type of control is known as variable head pressure control (VHPC). These nine new motors were given a signal from the legacy variable frequency drive (VFD) to match the motor speed of the legacy motors. Determination of the energy savings of the EEM was performed over a two-month period, at which time a correlation between legacy and EEM power consumption was developed based on motor speed. Annual data that had been collected from 2016-2017 (before the two-month test period) was then leveraged to predict the annual energy savings of the EEM for a complete retrofit using both VHPC and constant fan speed control. Table 1 displays the quantitative results. The EEM saved 27% of total energy consumption of the condenser fan motors for constant fan speed control, while the energy savings increased to 32% when using VHPC. This was due to the improved motor efficiency of the HRSR motor at low speeds. While the constant speed fan control kept the motors running at 870 rpm, VHPC adjusted fan speed between 200-870rpm based on the outdoor air temperature and the compressor discharge pressure. These savings are assuming a direct replacement with no additional controls. Retrofitting a constant speed fan control system with HRSRMs and switching to VHPC would provide significant energy savings looking at the condenser alone. Additional considerations of the EEM were noted during the project as well. The HRSRM system made it possible to identify and remotely shutdown an individual motor when a piece of foam locked the fan and thereby the motor. With the traditional system, a locked rotor could have caused motor damage unless a breaker or fuse was activated. Furthermore, due to vibration complaints from the installation technicians, the ramp-up time of the HRSRM had to be increased to a minute. After implementing this change no complaints for excessive vibration were recorded.

15 GEOTHERMAL ENERGY↗

Developing an Efficient Cyanobacteria Sugar Production Platform

The purpose of the CRADA between Sandia National Laboratories (Sandia), Lawrence Berkeley National Laboratory (LBNL), and HelioBioSys, Inc. (HBS) was to generate a resilient cyanobacterial community for the purpose of low cost polysaccharide production from outdoor cultivation. Sandia conducted algae culturing at benchscale and in pilot scale open raceways at the Algae Testbed facility in the Sandia-California (SNL-CA) Open Campus in Livermore with monitoring of changes in the cyanobaceterial community structure based on variation in growth conditions. LBNL provided capabilities for separating sugars that are excreted from the cyanobacterial cells on-site in Livermore, and performed bench scale conversion testing at the LBNL Advanced Biofuels Process Development Unit (ABPDU). The combination of pilot scale algae culturing at Sandia and conversion testing at the state-of-the-art ABPDU facility provided HelioBioSys, Inc. with initial data for de-risking deployment of outdoor production.

Davis, Ryan↗

Backsheets: Correlation of Long-Term Field Reliability with Accelerated Laboratory Testing

Our objective is to develop for backsheets a predictive tests and a model based on point-in-time data from analytical techniques and datastreams that are applicable to both outdoor and indoor PV module backsheet studies and are supplemented with meteorology data, climatic and brand/model, and other accessible information. The predictive tests and models will specify indoor and outdoor exposure and evaluation data acquisition criteria, variable selection, and temporal duration and variation so as to be able to predict backsheet performance in various climatic zones. This backsheet performance prediction is based on defined backsheet failures in the field, and is quantified by tracking backsheet degradation in the field so as to determine degradation rates.

14 SOLAR ENERGY↗

Regional Shelter Analysis: Inhalation Exposure Methodology

During normal operations, buildings can protect their occupants from outdoor hazards, including airborne pollutants. Purposeful sheltering increases this protection. A longterm international research effort has advanced our knowledge of building protection physics. However, an operationally efficient, regional-scale methodology to account for US building protection effects is not available. Such a method is necessary because (a) the overwhelming majority of the US population is indoors at any given time and (b) a regional-level building protection methodology could better estimate populations truly at risk in emergencies, support improved decision-making (shelter vs. evacuation decisions), help guide resources towards those most at risk, and improve population level dose-response relationships, which are often derived by estimating ambient (outdoor) exposures and then tuning dose-response relationship parameters to best match the distribution of illness reports.

54 ENVIRONMENTAL SCIENCES↗

Comparing wall performance predicted from hygrothermal simulations to wall performance measured from environmental chamber experiments

To effectively mitigate prevailing perceptions of potential moisture risks in high-R wall assemblies, a comprehensive moisture durability assessment that incorporates BA team field evaluations, lab tests and simulations has been completed over the last couple years. In FY18, three stick-built walls were succumbed to typical Chicago weather in ORNL’s Heat, Air and Moisture chamber. The measured temperature, relative humidity and moisture content within these walls were compared to WUFI hygrothermal simulation results. In FY19, similar experiments and comparison to WUFI results were completed with two walls, a Structural Insulated Panel (SIP) based wall and a Concrete Masonry Unit (CMU) based wall. The following tasks were completed for these two walls: 1. Measure air permeance of each individual wall using ASTM E283 Standard Test Method. 2.Test walls in diffusion scenario as only moisture transport mechanism and compare measured transient temperature and relative humidity of select wall components to WUFI model results. Chicago summer and weather will be investigated. 3. Test walls in wetting event scenario and compare measured transient temperature and relative humidity of select wall components with Chicago summer weather to WUFI model results. 4. Test walls in diffusion/advection scenario. In addition to controlling outdoor chamber to match real outdoor weather, a pressure differential across the wall will be varied. Measured transient temperature and relative humidity of select wall components will be compared to WUFI model results. 5. Test walls in diffusion/advection with solar heating of cladding. In addition to the variables above, IR lamps will be used to heat the cladding on a diurnal cycle. Measured transient OSB MC and temperature will be compared to WUFI model results. This report documents the experimental method, results and comparison of the measured experimental hygrothermal performance of the two walls to simulations results.

42 ENGINEERING↗

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Realization of Algae Potential (REAP)

The goal of the REAP R&D program was to advance the DOE goal of demonstrating 5,000 gallons per acre per year by 2022 by developing an integrated process for producing at least 3,500 gallons of bio-fuel intermediate per acre per year. The work plan called for developing a transformation system for Chlorella with which constructs would be developed that demonstrated a 40% increase productivity by attenuating the light harvest antennae and that provided 300% increase in lipid content. In addition, REAP would cultivate thermophilic acidophiles and would explore crop rotation strategies. The extremophile R&D hedged the risk surrounding metabolic engineering and also explored mixotrophic strains that could provide productivity boosts on organic substrates. Cultivation was to be carried out in horizontal photobioreactors developed by Algenol, one of the REAP corporate partners. The horizontal Algeonol PBRs were made from inexpensive plastic film and had low mixing energy requirements. Progress was made toward a transformation system for Chlorella sorokiniana 1412, but much more time and effort were required than anticipated. As a result, antenna mutants and strains with enhanced lipid accumulation were not available for outdoor testing. Thus, the hypothesis that reducing light attenuation can enhance the net productivity remains untested. Further, Chlorella sorokiniana was found to be more susceptible to predation and infection when grown at NMSU. Later experiments at ASU have been more successful, but culture stability for C. sorokiniana remains a concern. A C. sorokiniana (UTEX 1230) proline-overproducing strain (P5CS) was constructed that provided higher thermo-tolerance and salinity tolerance in laboratory tests. Algenol horizontal photobioreactors were hampered by mixing problems and vertical versions had mixing and biofouling issues. Outdoor, flat-panel, air-lift systems at ASU provided excellent productivity for extremophiles and Chlorella alike. Galdieria sulphuraria mixotrophy enabled volumetric productivities of 1.0 g/L/day at 0.5 meter spacing and an aerial productivity of 82 g/m²/day in July. Mixing energy requirements were too high to achieve target GHG emissions. Over the course of the REAP experiment, sequential hydrothermal liquefaction (SEQHTL) and direct hydrothermal liquefaction (DHTL) experiments have been performed under a number of conditions. The total areal yield is 2300 gal/ac/yr under for the DHTL yields. This value falls to 1800 gal/ac/yr for the SEQHTL yields.

09 BIOMASS FUELS↗

DISCOVR: Development of Integrated Screening, Cultivar Optimization, and Verification Research

The DISCOVR consortium has developed and is applying an integrated platform and workflow for standardized, deep characterization of highly productive and resilient microalgae strains. New strains are screened using three consecutive tiers in a conceptual down-selection funnel to arrive at the most promising strains. At tier I, strains are screened on gradient incubators to determine their temperature and salinity tolerance range, and to evaluate their resistance to infectious agents (e.g., chytrids). At tier II, the strains’ winter and summer season biomass productivities are quantified in Laboratory Environmental Algae Pond Simulator (LEAPS) photobioreactors, and biomass composition is determined under N-replete and N-deplete conditions. At tier III, the best winter and summer season strains are evaluated in indoor crash ponds to determine their resilience to induced infections, and strains are tested in outdoor raceway ponds to confirm high biomass productivity and culture stability. The top strains are then evaluated in seasonal SOT outdoor pond culture trials at AzCATI, the dedicated Department of Energy SOT (State of Technology) testbed. Additional research is carried out on evaluating growth promoting molecules, reducing the impact of oxygen inhibition, optimizing pond operational conditions, measuring compositional shift dynamics, developing integrated pest management strategies, analysing culture health using 96 well-plate tools, implementing spectroradiometric monitoring and using machine learning to predict culture crashes.

Huesemann, Michael H↗

Specifying Calibration of Environmental Sensors

The emergence of the Internet of Things is resulting in an increased ability of devices and systems to share data and is generating increasing interest in integrating sensors into a variety of devices deployed in the built environment. The value of such data is a function of how the data can be used. Data-producing devices and systems that enable valuable use-cases in turn can be seen as more valuable. Lighting systems are particularly interesting platforms for integrated sensors. Both indoor and outdoor lighting devices are becoming more connected, and their location is often ideally suited for hosting environmental sensors that can characterize the properties of indoor or outdoor spaces in ways that support a wide variety of use cases, from improving air quality to supporting fault diagnostics and prediction. The value of environmental-sensor-driven use-cases and the lighting systems that house them is dependent to some degree on sensor accuracy. Environmental sensors utilize a wide variety of sensing techniques or technologies and have varying accuracy. More-accurate, laboratory-grade products or reference standards are often used to characterize, refine, calibrate, adjust, and monitor devices that are deployed, or are intended to be deployed, in physical spaces of interest. Sensors or reference standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user and use-case requirements. This paper provides guidance for evaluating the performance of environmental sensors so as to ensure that they meet user or use-case needs. It describes best practices that have been developed for a) calibrating sensors to ensure some known level of accuracy, and b) determining whether calibration-laboratory accreditation meets user or use-case needs. Excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently have sensors calibrated or who have new or changing needs for sensor calibration, rationale is provided for why a specification might be used to request calibration services that meet specific needs. Commercially available calibration-service providers that are accredited for environmental-sensor calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of environmental-sensor test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

42 ENGINEERING↗

PACT Data Management Plan (V.1.0)

The Perovskite PV Accelerator for Commercial Technology (PACT) is an independent validation center for the evaluation of perovskite PV technologies and their bankability. The center is led by Sandia National Laboratories and the National Renewable Energy Laboratory (NREL) and includes as part of its team Los Alamos National Laboratory (LANL), CFV Labs, Black and Veatch (B&V), and the Electric Power Research Institute (EPRI). The goals of the center are to: Develop and improve indoor and outdoor performance characterization methods, Develop and validate accelerated qualification testing for early failures (5-10 years), Research degradation and failure modes, Validate outdoor performance, and Provide bankability services to US perovskite PV (PSC) industry. The importance of data and data management to the success and outcomes of the PACT center is paramount. This report describes how data will be managed and protected by PACT and identifies important data management principles that will guide our approach.

14 SOLAR ENERGY↗