Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Notes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Note: Establishing α-particle radiation damage experiments using the Dalton Cumbrian Facility’s 5 MV tandem pelletron

Evaluating the radiation stability of mineral phases is a vital research challenge when assessing the performance of the materials employed in a Geological Disposal Facility for radioactive waste. This report outlines the setup and methodology for efficiently allowing the determination of the dose dependence of damage to a mineral from a single ion irradiated sample. The technique has been deployed using the Dalton Cumbrian Facility’s 5 MV tandem pelletron to irradiate a suite of minerals with a controlled α-particle ({sup 4}He{sup 2+}) beam. Such minerals are proxies for near-field clay based buffer material surrounding radioactive canisters, as well as the sorbent components of the host rock.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A note on structural and dielectric properties of BiFeO{sub 3}- PbTiO{sub 3} and BiFeO{sub 3}- PbZrO{sub 3} composites

The composites of BiFeO{sub 3}-PbTiO{sub 3} (BF-PT) and BiFeO{sub 3}-PbZrO{sub 3} (BF-PZ) were prepared by mixed oxide method. Room temperature X-ray diffraction data confirms the rhombohedral and tetragonal crystal structure respectively. Dielectric constant of BF-PZ is found to give high value compared to BF-PT and hence, there is an increase value of ac conductivity for the former. Both the composites show negative temperature coefficient of resistance (NTCR) behavior. The activation energies of BF-PT and BF-PZ are found to be 0.35 eV and 0.53 eV respectively. The d{sub 33} coefficients are found to be 2.0 and 2.1 pC/N for BF-PT and BF-PZ respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: A silicon-on-insulator microelectromechanical systems probe scanner for on-chip atomic force microscopy

A new microelectromechanical systems-based 2-degree-of-freedom (DoF) scanner with an integrated cantilever for on-chip atomic force microscopy (AFM) is presented. The silicon cantilever features a layer of piezoelectric material to facilitate its use for tapping mode AFM and enable simultaneous deflection sensing. Electrostatic actuators and electrothermal sensors are used to accurately position the cantilever within the x-y plane. Experimental testing shows that the cantilever is able to be scanned over a 10 μm × 10 μm window and that the cantilever achieves a peak-to-peak deflection greater than 400 nm when excited at its resonance frequency of approximately 62 kHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: A three-dimension active vibration isolator for precision atom gravimeters

An ultra-low frequency active vibration isolator, simultaneously suppressing three-dimensional vibration noise, is demonstrated experimentally. The equivalent natural period of the isolator is 100 s and 12 s for the vertical and horizontal direction, respectively. The vibration noise in the vertical direction is about 50 times reduced during 0.2 and 2 Hz, and 5 times reduced in the other two orthogonal directions in the same frequency range. This isolator is designed for atom gravimeters, especially suitable for the gravimeter whose sensitivity is limited by vibration couplings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Application of CR-39 plastic nuclear track detectors for quality assurance of mixed oxide fuel pellets

A CR-39 plastic nuclear track detector was used for quality assurance of mixed oxide fuel pellets for next-generation nuclear power plants. Plutonium (Pu) spot sizes and concentrations in the pellets are significant parameters for safe use in the plants. We developed an automatic Pu detection system based on dense α-radiation tracks in the CR-39 detectors. This system would greatly improve image processing time and measurement accuracy, and will be a powerful tool for rapid pellet quality assurance screening.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A portable Raman analyzer for microfluidic chips based on a dichroic beam splitter for integration of imaging and signal collection light paths

An integrated and portable Raman analyzer featuring an inverted probe fixed on a motor-driving adjustable optical module was designed for the combination of a microfluidic system. It possesses a micro-imaging function. The inverted configuration is advantageous to locate and focus microfluidic channels. Different from commercial micro-imaging Raman spectrometers using manual switchable light path, this analyzer adopts a dichroic beam splitter for both imaging and signal collection light paths, which avoids movable parts and improves the integration and stability of optics. Combined with surface-enhanced Raman scattering technique, this portable Raman micro-analyzer is promising as a powerful tool for microfluidic analytics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Fiber optic transport probe for Hall measurements under light and magnetic field at low temperatures: Case study of a two dimensional electron gas

A fiber optic based probe is designed and developed for electrical transport measurements in presence of quasi-monochromatic (360–800 nm) light, varying temperature (T = 1.8–300 K), and magnetic field (B = 0–7 T). The probe is tested for the resistivity and Hall measurements performed on a LaAlO{sub 3}–SrTiO{sub 3} heterointerface system with a conducting two dimensional electron gas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A new regulation method of stable operation of high power cathode ion source

The hot cathode ion source will tend to be unstable when operated with high power and long pulse. In order to achieve stable operation, a new regulation method based on the arc power (discharge power) feedback control was designed and tested on the hot cathode ion source test bed with arc discharge and beam extraction. The results show that the new regulation method can achieve stable arc discharge and beam extraction. It verifies the success of feedback control of arc source with arc power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Work function change measurement via improved Anderson method

We propose the modification to the Anderson method of work function change (Δϕ) measurements. In this technique, the kinetic energy of the probing electrons is already low enough for non-destructive investigation of delicate molecular systems. However, in our implementation, all electrodes including filament of the electron gun are polarized positively. As a consequence, electron bombardment of any elements of experimental system is eliminated. Our modification improves cleanliness of the ultra-high vacuum system. As an illustration of the solution capabilities, we present Δϕ of the Ag(100) surface induced by cobalt phthalocyanine layers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector

A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO{sub 3}){sub 4} ⋅ 5H{sub 2}O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: On the wavelength dependence of the intensity calibration factor of extreme ultraviolet spectrometer determined with profile measurement of bremsstrahlung continuum

The absolute calibration factor of extreme ultraviolet spectroscopic instrument which has recently been determined from absolute radiation profile measurement of bremsstrahlung continuum has been investigated by comparing the calculated diffraction efficiency of grating. An overall tendency of the wavelength dependence of the calibration factor from 40 Å to 500 Å can be reproduced by that of the grating efficiency, especially the agreement between the measured calibration factor and the calculated grating efficiency has been found to be fairly good for the wavelength range 200 Å-500 Å.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A single-chamber tool for plasma activation and surface functionalization in microfabrication

We present a simple apparatus for improved surface modification of polydimethylsiloxane (PDMS) microfluidic devices. A single treatment chamber for plasma activation and chemical/physical vapor deposition steps minimizes the time-dependent degradation of surface activation that is inherent in multi-chamber techniques. Contamination and deposition irregularities are also minimized by conducting plasma activation and treatment phases in the same vacuum environment. An inductively coupled plasma driver allows for interchangeable treatment chambers. Atomic force microscopy confirms that silane deposition on PDMS gives much better surface quality than standard deposition methods, which yield a higher local roughness and pronounced irregularities in the surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗