Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Multiplication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Report on Inventory of Samples from Six Capsules from BOR-60

As part of the University of Michigan Grand Challenge Integrated Research Project, Oak Ridge National Laboratory (ORNL) received a drum containing six capsules from Pacific Northwest National Laboratory in August 2025. Each capsule originated at the University of Michigan and contained approximately 44 disks of various iron-based alloys (T91, HT9, T92, 800H, and others). These capsules were irradiated at several temperatures in the BOR-60 fast reactor for multiple cycles to accumulate high levels of damage. The drum was sent to the Irradiated Materials Examination and Testing (IMET) hot cell facility, a Class III nuclear facility, located in Building 3025E at ORNL. The IMET hot cell facility at ORNL is designed to receive irradiation capsules from the High Flux Isotope Reactor and perform capsule opening, basic optical examination, and mechanical testing on neutron-irradiated materials. Capsules were unloaded from the drum and placed in cell 6 for disassembly in February 2026. A low-speed saw opened each capsule, and a manipulator moved the disks to a dual microscope setup for disk identification, as shown in Figure 1.

36 MATERIALS SCIENCE↗

In Situ Scattering Studies of Crystallization Kinetics in a Phase-Separated Zr–Cu–Fe–Al Bulk Metallic Glass

In this work, thermal stability and the crystallization kinetics of a phase-separated Zr-Cu-Fe-Al bulk metallic glass were investigated using in situ high-energy synchrotron X-ray and neutron diffraction, as well as small-angle synchrotron X-ray scattering. It was revealed that this glass with excellent glass-forming ability possesses a two-step crystallization behavior. The crystalline products and their evolution sequence are more complicated than a homogeneous Zr-Cu-Al glass with average glass-forming ability. The experimental results indicate that a finely distributed nanometer-sized cubic Zr 2 Cu phase forms first and then transforms to a tetragonal Zr 2 Cu phase, while the matrix transforms to an orthorhombic Zr3Fe phase. The strength of the Zr-Cu-Fe-Al composite containing cubic Zr 2 Cu phase and glass matrix increases, and the plasticity also improves compared to the as-cast Zr-Cu-Fe-Al bulk metallic glass. Our results suggest that the formation of multiple and complex crystalline products would be the characteristics of the Zr-Cu-Fe-Al glass with better glass-forming ability. Our study may shed light on the synthesis of bulk-sized glass-nanocrystals composites of high strength and good plasticity.

36 MATERIALS SCIENCE↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application-Specific Implementations: Self-Consistent Analysis, Uncertainty Estimation, Instrumentation Effects

When UF 6 is located on the bottom of a cylindrical container lying flat, the Hage-Cifarelli formalism can be used to reconstruct the multiplication of the UF 6 and the strength of the 234 U (a,n) source, from which the 235 U can be inferred. However, when the UF 6 sticks to the ends or to the sides of the container, the reconstruction is no longer predictive in terms of source strength. The same conclusions were reached, whether one uses 3 He tubes or scintillators to detect the neutrons. Feynman’s point theory underlying the reconstruction would need to be improved to address the differences in source strenghts observed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of Benchmark $k$ eff Sensitivity and Uncertainty for 239 Pu fission in Specific Energy Ranges

Nuclear data at intermediate energies (from 1 to 100s of keV) are evaluated based on scarce differential data and theory unable to capture physics’ expected structure. There is also a lack of integral data. This is a known deficiency and is challenging to address. Calculated effective multiplication factor, k eff , values for intermediate energy experiments are ~25× further from experiment than for fast energies and are often well outside the experimental uncertainties. The goal of the PARADIGM (PARallel Approach of Differential and InteGral Measurements) project is to significantly re duce the uncertainties of intermediate energy nuclear data for 239 Pu. To this end, PARADIGM simultaneously optimizes experiments at both the Los Alamos Neutron Science Center (LANSCE) and National Criticality Experiments Research Center (NCERC). The combined set of data will inform new intermediate-energy nuclear data. By execution of differential and integral experiments, establishment of new theory, and undertaking nuclear data evaluation in parallel, the timeline to deliver improved nuclear data to users will be reduced significantly that is to three years. For the PARADIGM project, it was decided to optimize an integral experiment for two neutron energy ranges, within the full intermediate energy range. The low energy range goes from 1 to 30 keV, while the higher energy range goes from 30 to 600 keV. This work focuses on nuclear data sensitivities and uncertainties for 239 Pu fission for existing experiments in the International Criticality Safety Benchmark Evaluation Project (ICSBEP). When designing new experiments, it is important to understand what benchmarks currently exist. For a more traditional experiment design (in which a specific application model(s) exists), comparisons would be made between the application model(s) and existing benchmarks. For PARADIGM, there is no specific application model, but instead the specific nuclear data reaction and energy ranges of interest can be explored for existing benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Criticality and Magnetic Phases of Ising Shastry–Sutherland Candidate Holmium Tetraboride

Frustrated magnetic systems arising in geometrically constrained lattices represent rich platforms for exploring unconventional phases of matter, including fractional magnetization plateaus, incommensurate orders and complex domain dynamics. However, determining the microscopic spin configurations that stabilize such phases is a key challenge, especially when in-plane and out-of-plane spin components coexist and compete. Here, we combine neutron scattering and magnetic susceptibility experiments with simulations to investigate the emergence of field-induced fractional plateaus and the related criticality in a frustrated magnet holmium tetraboride (HoB 4 ) that represents the family of rare earth tetraborides that crystalize in a Shastry–Sutherland lattice in the ab plane. We focus on the interplay between classical and quantum criticality near phase boundaries, as well as the role of material defects in the stabilization of the ordered phases. We find that simulations using classical annealing can explain certain observed features in the experimental Laue diffraction and the origin of multiple magnetization plateaus. Our results show that defects and out-of-plane interactions play an important role and can guide the route towards resolving microscopic spin textures in highly frustrated magnets.

Frustration↗

Report on Evolution of Inconel 718 Following HFIR Irradiation

The report presents the microstructure and mechanical properties of 3D printed Inconel 718 after irradiation in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) to assess its potential use as a structural material. The structural components near the outlets of several proposed reactor cores will experience significant neutron fluxes and outlet coolant temperatures ranging from the hot standby temperature of 300 °C to nearly 550 °C at the center of the part. These components must support the core in appropriate loading conditions and require structural analysis at relevant temperatures. In FY21, three heat treatments were designed and conducted to simplify the microstructure and to determine how each precipitating phase contributed to the overall strength. In FY21, baseline mechanical properties were measured from uniaxial tensile tests on subsize SS-J2 specimens at room temperature and at elevated temperatures of 300, 450, and 600 °C to serve a comparison to the irradiated properties. Four capsules containing 3D printed Inconel 718 were inserted into HFIR in FY21 for a matrix of two temperatures and two doses. The lower of the two doses was available for characterization in FY22. Multiple heat treatments of Inconel 718 irradiated to nominal conditions of 2 displacements per atom (dpa) at either 300 or 600 °C were strained with uniaxial tensile tests at the Irradiated Material Examination and Testing (IMET) Facility to discern the mechanical properties. Transmission electron microscopy was performed to correlate the observed mechanical properties with nanoscale features. The initially homogenous AM718-HM increased in strength at both irradiation temperatures based on a high density of nanometer-scale radiation-induced cavities at lower temperature and nucleation and growth of γ" precipitates at higher temperatures. The precipitate-hardened AM718-HT2 showed very small differences in strength before and after irradiation: the contribution to strength from γ" precipitates was replaced with dislocation loops. Because the radioactivity of the nickel superalloys from neutron activation limited the scope of the analysis, a feasibility study examined the possibility of an ultra-miniature specimen geometry, colloquially SS-Tiny (SS-T), for mechanical property determination using the nonirradiated Inconel 718. This study found an overestimation of ductility from the SS-T geometry with yield strength and ultimate tensile strength slightly above the SS-J2 geometry: this could be contributed to a reduction in specimen thickness.

36 MATERIALS SCIENCE↗

Multiple Lattice Instabilities and Complex Ground State in Cs 2 Ag Bi Br 6

Metal-halide perovskites (MHPs) are attracting considerable interest for optoelectronic applications, with Cs 2 Ag Bi Br 6 one of the main contenders among lead-free systems. Cs 2 Ag Bi Br 6 crystallizes in a nominally double-perovskite structure, but exhibits a soft lattice with large atomic fluctuations characteristic of MHPs. While crucial to understand electron-phonon and phonon-phonon couplings, the spatiotemporal correlations of these fluctuations remain largely unknown. Here, we reveal these correlations using comprehensive neutron and x-ray scattering measurements on Cs 2 Ag Bi Br 6 single crystals, complemented with first-principles simulations augmented with machine-learned neural-network potentials. We report the discovery of an unexpected complex modulated ground-state structure containing several hundred atoms, arising from a soft-phonon instability of the low-temperature tetragonal phase. Further, our experiments and simulations both reveal extensive correlated two-dimensional fluctuations of Br octahedra at finite temperature, arising from soft optic phonons that are strongly broadened by anhamonicity, reflecting very shallow potential wells. These results provide new insights into the atomic structure and fluctuations in MHPs, critical to understand and control their thermal and optoelectronic properties. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Feasibility Assessment of a Natural-Circulation Salt Irradiation Loop in the Advanced Test Reactor

Molten-salt reactors will likely require some level of irradiation testing as part of their licensing basis. An ideal experiment would consider the integrated effect of neutron flux and fission product generation in addition to circulating flow conditions. The feasibility of a natural-circulation irradiation salt loop in the Advanced Test Reactor (ATR) is assessed here. The flow is induced by the innovative combination of gas gaps and fin gaps along the capsule wall to fine-tune radial heat conductance, and therefore drive an axial temperature gradient across the experiment height. Following multiple design optimizations, a promising configuration has been identified. The 45-kW experiment would generate a 0.15 m/s flow velocity with 6 kg of fuel-bearing salt. This demonstrates the possibility of generating appreciable flow rates within manageable experimental conditions (e.g., total size and heat generation). An initial assessment of species mass tracking inside the experiment was also performed to gain an understanding of radionuclide behavior within the system. Results showed that significant quantities of Xe can be extracted in the off-gas (1.7 kCi) for an 8% bubble removal efficiency rate. Here, these results highlight the potential value of such experiments. Further work will involve detailed engineering drawings and analyses of the loop, as well as more computationally expensive modeling of species mass tracking.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Precision measurement of positron decay modes of Xe-125 in the LUX-ZEPLIN experiment

The radioisotope $^{125}\text{Xe}$ is a short-lived ($T_{1/2}\sim16.9 h$) activation product of the neutron calibrations performed in the LUX-ZEPLIN experiment. Subsequently, $^{125}$Xe decays primarily ($>99\%$) via electron capture, but positron emission has been confirmed by direct measurement to at least the 243 keV level of $^{125}\text{I}$. An additional decay to the 188keV level is expected from triple-coincident measurements of the annihilation and relaxation $γ$ rays, but has not been directly confirmed. By utilizing multiple-scatter event analysis and the pre-activation data to constrain backgrounds, this work reports positron emission with a statistical significance of 5.5$σ$. This corresponds to a total branching ratio of $0.29\pm0.08_{\text{stat.}}\pm0.04_{\text{sys.}}$%, and is the first constraint to the individual branching levels of $^{125}\text{I}$.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Light-nuclei production and search for the QCD critical point

We discuss the potential of light-nuclei measurements in heavy-ion collisions at intermediate energies for the search of the hypothetical QCD critical end-point. A previous proposal based on neutron density fluctuations has brought appealing experimental evidences of a maximum in the ratio of the number of tritons times protons, divided over deuterons square, $\mathcal{O}_{tpd}$. However these results are difficult to reconcile with the state-of-the-art statistical thermal model predictions. Based on the idea that the QCD critical point can lead to a substantial attraction among nucleons, we propose new light-nuclei multiplicity ratios involving 4 He in which the maximum would be more noticeable. We argue that the experimental extraction is feasible by presenting these ratios formed from actual measurements of total and differential yields at low and high collision energies from FOPI and ALICE experiments, respectively. We also illustrate the possible behavior of these ratios at intermediate energies applying a semiclassical method based on flucton paths using the preliminary NA49 and STAR data for $\mathcal{O}_{tpd}$ as input.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncovering hidden bias in neutron diffraction residual strain measurements

When calculating residual strain via neutron or X-ray diffraction, uncertainties propagated from the peak fit are often inadequate to describe the true scatter of measurements about a singular strain state, such as one that should describe a macroscopic continuum. Because diffraction is inherently a selective process, orientation-dependent scatter arises from the sub-sampling of strong microstructure and strain gradients. This paper investigates the appropriateness of propagated uncertainties with reference to their original intention, i.e. noise about a mean value. Thirty-six unique orientations of strain measurements are taken at multiple locations within an additive friction-stir deposition component with fine-scale gradients (∼200 µm) of plastic strain, texture and residual elastic strain. Multiple strain and stress calculation pathways are compared: direct substitution of three measurements into Hooke's law, direct inversion of any six unique orientations into the strain state tensor and thirty-six measurement least-squares estimation. For the last two cases, the appropriateness of the uncertainty interval is statistically evaluated on the basis of a physical constraint: common agreement under the strain transformation law. For this sample, the direct inversion of six measurements retains a conservative estimate of the uncertainty. However, propagated uncertainties in the least-squares solution greatly underestimate the true experimental scatter. A simple pathway to estimate appropriate uncertainty intervals is suggested. These results demonstrate that the interpretation of uncertainty in residual strain is strongly dependent on intrinsic sample-dependent effects, and that oversampling orientations and statistical analysis can give more accurate results with realistic uncertainties.

36 MATERIALS SCIENCE↗

Sawtooth lattice multiferroic BeCr 2 O 4 : Noncollinear magnetic structure and multiple magnetic transitions

Noncollinear magnetic structures and multiple magnetic phase transitions in a sawtooth lattice antiferromagnet consisting of Cr 3+ are experimentally identified in this work, thereby proposing the scenario of magnetism-driven ferroelectricity in a sawtooth lattice. The title compound, BeCr 2 O 4 , displays three magnetic phase transitions at low temperatures—at T N1 ≈ 7.5 K, at T N2 ≈ 25 K, and at T N3 ≈ 26 K—revealed through magnetic susceptibility, specific heat, and neutron diffraction in this work. These magnetic phase transitions are found to be influenced by externally applied magnetic fields. Isothermal magnetization curves at low temperatures below the magnetic transitions indicate the antiferromagnetic nature of BeCr 2 O 4 with two spin-flop-like transitions occurring at H c1 ≈ 29 kOe and H c2 ≈ 47 kOe. Our high-resolution x-ray and neutron diffraction studies, performed on single crystal and powder samples, unambiguously determined the crystal structure as orthorhombic Pbnm. By performing the magnetic superspace group analysis of the neutron diffraction data at low temperatures, the magnetic structure in the temperature range T N3,N2 < T < T N1 is determined to be the polar magnetic space group P21nm. 1' (00g) 0s0s with a cycloidal magnetic propagation vector k 1 = (0, 0, 0.090 (1)) . The magnetic structure in the newly identified phase below T N1 is determined as P21/b.1' [b] (00 g) 00s with the magnetic propagation vector k 2 = (0, 0, 0.908 (1)). Finally, the cycloidal spin structure determined in our work is usually associated with electric polarization, thereby making BeCr 2 O 4 a promising multiferroic belonging to the sparsely populated family of sawtooth lattice antiferromagnets.

36 MATERIALS SCIENCE↗

Determination of Molecular Structure and Dynamics of Molten Salts by Advanced Neutron and X-ray Scattering Measurements and Computer Modeling

The design and development of fully functional Molten-Salt Reactors (MSR) require detailed knowledge of the molten salt properties in order to understand and predict the salt’s behavior. Fundamental properties of interest include molecular structure, speciation, and dynamics (such as diffusion coefficients) of salt components and dissolved corrosion and fission products. Computer modeling is necessary to predict changes in physical and chemical properties due to irradiation, burning of dissolved fuel, and corrosion. The modeling requires experimental data, and advanced neutron and x-ray scattering and spectroscopy provide the most reliable and direct determination of the structure (Pair-Distribution Functions, PDF), and dynamics of ions in the melt. This project dealt with both fluoride and chloride salts. The PDFs have been measured by a combination of neutron and x-ray diffraction. We utilized the techniques of isotope substitutions, a very powerful tool available for neutron-scattering, to extract the details of the liquid structure. Although similar measurements have been done before, modern advanced neutron and x-ray-scattering techniques allow collecting the data at much higher resolution and in a wider range of temperatures. Importantly, we were among the first to study fluoride salts by neutron scattering. The importance of impurities and their effects on salt properties have become apparent recently and so new methods of salt purification were developed. We took advantage of these developments to produce reliable data, which have been used for computer simulations of both clean salts and those with added fission and corrosion products most relevant for MSRs. Ab initio molecular dynamics simulations have been performed to understand the multi-component liquid solution, in particular solubility of impurities and thermodynamic interactions in relation to the ionic-cluster structure of the fluid. We applied machine learning to regress from the simulation and experimental data in order to develop a fast-acting model that can handle molten salt with an arbitrary (≥ 10) number of chemical elements and be able to predict chemical potential as a function of composition and temperature. This project resulted in a number of experimental and computer-simulation publications, a patent application, and numerous conference presentations (American Physical Society, American Chemical Society, and The Electrochemical Society among others). Multiple students and postdocs participated and collaborated on aspects of this project. This project seeded new collaborations between MIT and other institutions, such as the University of Massachusetts Lowell, the University of Illinois Urbana-Champaign, the University of California Berkeley, and Oak Ridge and Los Alamos National Labs. As such, this project has had a broad and lasting impact beyond its original scientific scope.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Inelastic Neutron Spectra of Uranium Tetrafluoride Hydrate, UF 4 (H 2 O) 2.5

Uranium tetrafluoride hydrate (UFH) is formed by immersing anhydrous UF4 under water for 12 h. UFH is therefore clearly a chemical species of environmental concern, as anhydrous UF4 is an intermediate uranium form in the nuclear fuel cycle. We use inelastic neutron scattering (INS) to probe the full vibrational spectra of UFH and its deuterated analogue in an effort to improve the fundamental understanding of its vibrational spectra. Coupled with density functional theory (DFT) calculations, the first for this compound, and full spectral modeling, we generate the complete vibrational spectra of UFH and compare them to prior optical spectroscopic results. In particular, the combination of DFT with INS allows us to identify multiple distinct chemical environments in the water bending and OH stretching regions. Whereas the water molecules directly bound to the U atoms execute OH stretching around 3600 cm –1 , a second class of H-bonded waters vibrate below 3000 cm –1 , an indicator of strong H bonding. In addition, a class of librational water modes are observed between 400 and 900 cm–1, which themselves can be separated in energy according to their chemical environments. Furthermore, measurements presented herein directly assist in the assignment of certain spectral features in the infrared spectrum and will inform future investigations of UFH for environmental or forensics purposes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Record of Decision: H - LEBT Design Modifications

The LAMP Conceptual Design (LCD) is described in the LAMP Conceptual Design Report. The proposed new configuration of the LAMP H - LEBT encompasses multiple changes to the LCD. The new configuration makes use of a single H - source to supply beam to all LANSCE user stations except IPF; this eliminates one of the H - sources in the LCD, and the associated pulsed merger magnet the use of two such sources required. The source current from the sole H - source is gated on a macropulse-by-macropulse basis using techniques demonstrated at SNS (Spallation Neutron Source), specifically, changes to the RF plasma drive power. A pulsed electrode system is used to match the beam into the LEBT transport line, variable on a macropulse-by-macropulse basis to match the source beam current.

43 PARTICLE ACCELERATORS↗