Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Elimination of ghosting artifacts from wavelength-shifting fiber neutron detectors

Misassignment of neutron position (ghosting) produces artifacts, which have been observed in wavelength-shifting (WLS) fiber detectors developed for time-of-flight (TOF) neutron powder diffraction. In position-sensitive detectors (PSDs) with WLS fiber encoding, thermal and cold neutrons interact with a monolithic 6LiF/ZnS:Ag scintillator screen, and scintillation photons are generated and transported through the crossed fibers to photomultipliers (PMTs). The neutron position is determined by photon counts in PMTs within a preset time window. Ghosting occurs when neutrons hit the group boundaries of two neighboring PMTs for x-position multiplexing, which is modeled as resulting from a long travel length (about 3-5 mm) of a small number of scintillation photons. This model is supported by the change observed in aperture images when the threshold number for photon-pulses was adjusted for a neutron event determination. When the threshold number of photon-pulses was set above 10 for each PMT, the ghost peaks in the aperture images and TOF spectra of powder diffraction were strongly suppressed or completely eliminated, and the intrinsic background levels of the WLS detectors were significantly reduced. Our result indicates that WLS fiber detector is a promising alternative for 3He PSDs for neutron scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact stilbene crystal neutron spectrometer for EAST D-D plasma neutron diagnostics

A new compact stilbene crystal neutron spectrometer has been investigated and applied in the neutron emission spectroscopy on the EAST tokamak. A new components analysis method is presented to study the anisotropic light output in the stilbene crystal detector. A Geant4 code was developed to simulate the neutron responses in the spectrometer. Based on both the optimal light output function and the fitted pulse height resolution function, a reliable neutron response matrix was obtained by Geant4 simulations and validated by 2.5 MeV and 14 MeV neutron measurements at a 4.5 MV Van de Graaff accelerator. The spectrometer was used to diagnose the ion temperature in plasma discharges with lower hybrid wave injection and ion cyclotron resonance heating on the EAST tokamak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron capture measurement on {sup 173}Lu at LANSCE with DANCE detector

The (n,{gamma}) cross section on the unstable {sup 173}Lu(t{sub 1/2} = 1.37y) has been measured from thermal energy up to 200 eV at Los Alamos Neutron Science Center (LANSCE) with The Detector for Advanced Neutron Capture Experiements (DANCE). The main aim of this study is to validate and optimize reaction models for unstable nucleus. A preliminary capture yield will be presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the BINS superheated drop detector spectrometer to the {sup 9}Be(p,xn) neutron energy spectrum determination

In the framework of TRASCO-BNCT project, a Bubble Interactive Neutron Spectrometer (BINS) device was applied to the characterization of the angle-and energy-differential neutron spectra generated by the {sup 9}Be(p,xn)reaction. The BINS spectrometer uses two superheated emulsion detectors, sequentially operated at different temperatures and thus provides a series of six sharp threshold responses, covering the 0.1-10 MeV neutron energy range. Spectrum unfolding of the data was performed by means of MAXED code. The obtained angle, energy-differential spectra were compared with those measured with a Bonner sphere spectrometer, a silicon telescope spectrometer and literature data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and modeling of muon-induced neutrons in LSM in application for direct dark matter searches

Due to a very low event rate expected in direct dark matter search experiments, a good understanding of every background component is crucial. Muon-induced neutrons constitute a prominent background, since neutrons lead to nuclear recoils and thus can mimic a potential dark matter signal. EDELWEISS is a Ge-bolometer experiment searching for WIMP dark matter. It is located in the Laboratoire Souterrain de Modane (LSM, France). We have measured muon-induced neutrons by means of a neutron counter based on Gd-loaded liquid scintillator. Studies of muon-induced neutrons are presented and include development of the appropriate MC model based on Geant4 and analysis of a 1000-days measurement campaign in LSM. We find a good agreement between measured rates of muon-induced neutrons and those predicted by the developed model with full event topology. The impact of the neutron background on current EDELWEISS data-taking as well as for next generation experiments such as EURECA is briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the muon-induced neutron yield in liquid scintillator and stainless steel at LNGS with the LVD experiment

We describe the measurement of the muon-induced neutron yield in liquid scintillator and stainless steel (SS) at the Gran Sasso National Laboratory (LNGS), with the LVD experiment. The Large Volume Detector (LVD) is located in Hall A of the LNGS and is made of 1000 t of liquid scintillator and 1000 t of SS. Using an independent measurement to evaluate the background and with the support of a full Monte Carlo simulation based on Geant4, we measured a neutron yield of (2.9±0.6)×10{sup −4} and (1.5±0.3)×10{sup −3} in liquid scintillator and in stainless steel, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The autofocusing system of the IMAT neutron camera

In this paper, we present the autofocusing system of the imaging instrument to be used on IMAT, a new neutron-imaging facility under construction at the ISIS (UK) target station 2. We have compared 16 different autofocus algorithms to select the one with the best performance. The algorithms have been evaluated by using both a qualitative analysis and a quantitative one. An overall score has been computed and the “contrast based” algorithm has been selected for the autofocusing system. The adopted setup together with the described autofocusing system makes the camera a user-friendly imaging device allowing the optimization of beam time use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance study of polycrystalline CVD diamond detectors for fast neutron monitoring

Diamond detectors using polycrystalline CVD diamond substrates of thickness 300μm and 100μm were fabricated for fast neutron monitoring application.. The characterization of detectors was carried out using various tests such as leakage current, capacitance and alpha particle response. The performance of detectors was evaluated for fast neutrons at different neutron yields. The results presented in this work demonstrate that the diamond detectors will be suitable for monitoring fast neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plastic fiber scintillator response to fast neutrons

The Neutron Imaging System at NIF uses an array of plastic scintillator fibers in conjunction with a time-gated imaging system to form an image of the neutron emission from the imploded capsule. By gating on neutrons that have scattered from the 14.1 MeV DT energy to lower energy ranges, an image of the dense, cold fuel around the hotspot is also obtained. An unmoderated spallation neutron beamline at the Weapons Neutron Research facility at Los Alamos was used in conjunction with a time-gated imaging system to measure the yield of a scintillating fiber array over several energy bands ranging from 1 to 15 MeV. The results and comparison to simulation are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Forward fitting of experimental data from a NE213 neutron detector installed with the magnetic proton recoil upgraded spectrometer at JET

In this paper, we present the results obtained from the data analysis of neutron spectra measured with a NE213 liquid scintillator at JET. We calculated the neutron response matrix of the instrument combining MCNPX simulations, a generic proton light output function measured with another detector and the fit of data from ohmic pulses. For the analysis, we selected a set of pulses with neutral beam injection heating (NBI) only and we applied a forward fitting procedure of modeled spectral components to extract the fraction of thermal neutron emission. The results showed the same trend of the ones obtained with the dedicated spectrometer TOFOR, even though the values from the NE213 analysis were systematically higher. This discrepancy is probably due to the different lines of sight of the two spectrometers (tangential for the NE213, vertical for TOFOR). The uncertainties on the thermal fraction estimates were from 4 to 7 times higher than the ones from the TOFOR analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Bayesian method to estimate the neutron response matrix of a single crystal CVD diamond detector

Detectors made from artificial chemical vapor deposition (CVD) single crystal diamond are very promising candidates for applications where high resolution neutron spectrometry in very high neutron fluxes is required, for example in fusion research. We propose a Bayesian method to estimate the neutron response function of the detector for a continuous range of neutron energies (in our case, 10 MeV ≤ E{sub n} ≤ 16 MeV) based on a few measurements with quasi-monoenergetic neutrons. This method is needed because a complete set of measurements is not available and the alternative approach of using responses based on Monte Carlo calculations is not feasible. Our approach uses Bayesian signal-background separation techniques and radial basis function interpolation methods. We present the analysis of data measured at the PTB accelerator facility PIAF. The method is quite general and it can be applied to other particle detectors with similar characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cherenkov neutron detector for fusion reaction and runaway electron diagnostics

A Cherenkov-type neutron detector was newly developed and neutron measurement experiments were performed at Korea Superconducting Tokamak Advanced Research. It was shown that the Cherenkov neutron detector can monitor the time-resolved neutron flux from deuterium-fueled fusion plasmas. Owing to the high temporal resolution of the detector, fast behaviors of runaway electrons, such as the neutron spikes, could be observed clearly. It is expected that the Cherenkov neutron detector could be utilized to provide useful information on runaway electrons as well as fusion reaction rate in fusion plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photocurrent response of B{sub 12}As{sub 2} crystals to blue light, and its temperature- dependent electrical characterizations

With the global shortage of {sup 3}He gas, researchers worldwide are looking for alternative materials for detecting neutrons. Among the candidate materials, semiconductors are attractive because of their light weight and ease in handling. Currently, we are looking into the suitability of boron arsenide (B{sub 12}As{sub 2}) for this specific application. As the first step in evaluating the material qualitatively, the photo-response of B{sub 12}As{sub 2} bulk crystals to light with different wavelengths was examined. The crystals showed photocurrent response to a band of 407- and 470- nm blue light. The maximum measured photoresponsivity and the photocurrent density at 0.7 V for 470 nm blue light at room temperature were 0.25 A ⋅ W{sup −1} and 2.47 mA ⋅ cm{sup −2}, respectively. In addition to photo current measurements, the electrical properties as a function of temperature (range: 50-320 K) were measured. Reliable data were obtained for the low-temperature I-V characteristics, the temperature dependence of dark current and its density, and the resistivity variations with temperature in B{sub 12}As{sub 2} bulk crystals. The experiments showed an exponential dependence on temperature for the dark current, current density, and resistivity; these three electrical parameters, respectively, had a variation of a few nA to μA, 1-100 μA ⋅ cm{sup −2} and 7.6x10{sup 5}-7.7x10{sup 3} Ω ⋅ cm, for temperature increasing from 50 K to 320 K. The results from this study reported the first photoresponse and demonstrated that B{sub 12}As{sub 2} is a potential candidate for thermal-neutron detectors.

36 MATERIALS SCIENCE↗

Investigation of light ion fusion reactions with plasma discharges

The scaling of reaction yields in light ion fusion to low reaction energies is important for our understanding of stellar fuel chains and the development of future energy technologies. Experiments become progressively more challenging at lower reaction energies due to the exponential drop of fusion cross sections below the Coulomb barrier. We report on experiments where deuterium-deuterium (D-D) fusion reactions are studied in a pulsed plasma in the glow discharge regime using a benchtop apparatus. We model plasma conditions using particle-in-cell codes. Advantages of this approach are relatively high peak ion currents and current densities (0.1 to several A/cm 2 ) that can be applied to metal wire cathodes for several days. We detect neutrons from D-D reactions with scintillator-based detectors. For palladium targets, we find neutron yields as a function of cathode voltage that are over 100 times higher than yields expected for bare nuclei fusion at ion energies below 2 keV (center of mass frame). A possible explanation is a correction to the ion energy due to an electron screening potential of 1000 ± 250 eV, which increases the probability for tunneling through the repulsive Coulomb barrier. Finally, our compact, robust setup enables parametric studies of this effect at relatively low reaction energies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

Structural characterization of highly alloyed (Al,Gd)N thin films

Highly alloyed (Al,Gd)N is of potential interest in a variety of applications, including neutron detection and in devices such as non-volatile memory. Gd has been shown to have very low equilibrium solubility in AlN at room temperature; however, non-equilibrium deposition techniques such as sputtering are able to deposit thin films, which incorporate large amounts of Gd. Here, we characterize a highly-alloyed (Al,Gd)N combinatorial thin film grown by RF sputtering on a GaN substrate, looking for any evidence of chemical or phase segregation or structural disorder in the films. Compositions with between 13% and 32% Gd (on a cation basis) were studied. No evidence was found for chemical or phase segregation in any studied composition. Higher degrees of Gd incorporation led to greater structural disorder in the film and a tendency toward amorphization; however, electron diffraction shows that the film does not become fully amorphous at any of the studied compositions, instead retaining textured local order even at 32% Gd. Electron energy loss spectra suggest that the material retains a locally wurtzite-like tetrahedral bonding environment at all studied compositions.

36 MATERIALS SCIENCE↗

Bayesian inference of anisotropic 2D small-angle scattering from sparse measurement

Here, we present a Bayesian inference framework for reconstructing anisotropic two-dimensional small-angle scattering (2D SAS) patterns from sparse, noisy, or partially missing data. The method combines a symmetry-aware angular basis with radial Gaussian process priors to enable accurate, training-free interpolation and denoising. Computational benchmarks demonstrate reliable recovery of both isotropic and high-order anisotropic features under severe data reduction. Experimental validations on stretched polymers, sheared wormlike micelles, and carbon fibers show improved fidelity and resolution compared to raw measurements, achieving comparable accuracy with up to 50-fold fewer detected neutrons. This approach enables quantitative structural analysis under low-flux, time-limited, or single-shot conditions, extending the applicability of 2D SAS techniques to compact neutron sources and mechanically driven soft matter systems undergoing transient structural changes.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗