Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Cross Section”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Demonstration of non-destructive and isotope-sensitive material analysis using a short-pulsed laser-driven epi-thermal neutron source

Neutrons are a valuable tool for non-destructive material investigation as their interaction cross sections with matter are isotope sensitive and can be used complementary to x-rays. So far, most neutron applications have been limited to large-scale facilities such as nuclear research reactors, spallation sources, and accelerator-driven neutron sources. Here we show the design and optimization of a laser-driven neutron source in the epi-thermal and thermal energy range, which is used for non-invasive material analysis. Neutron resonance spectroscopy, neutron radiography, and neutron resonance imaging with moderated neutrons are demonstrated for investigating samples in terms of isotope composition and thickness. The experimental results encourage applications in non-destructive and isotope-sensitive material analysis and pave the way for compact laser-driven neutron sources with high application potential.

36 MATERIALS SCIENCE↗

A Cold Moderator For Sub-Thermal Neutron Flux Enhancement at the RPI-LINAC

The importance of high-quality thermal neutron scattering kernels coupled with a lack of accurate sub-thermal total cross section data prompted researchers at Rensselaer Polytechnic Institute (RPI) to design a cold moderation system to enhance sub-thermal neutron flux (defined as flux below 5 meV), for nuclear data measurements at the RPI Gaerttner LINAC facility. Using a series of neutronic and heat transfer simulations obtained with MCNP and COMSOL, an optimized final design was produced. The final design exceeded current target sub-thermal neutron producing capabilities by a factor of 8 in the sub-thermal region and is easily configurable with existing neutron producing targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

J/ψ Near-Threshold Photoproduction off the Proton and Neutron with CLAS12

In recent years, J/? photoproduction in the near-threshold region has seen a renewed theoretical interest due to the wealth of information it has to offer. Near-threshold J/? photopro-duction proceeds through the exchange of gluons in the t-channel and is expected to provide unique insight about the nucleon gluonic gravitational form factors (GFFs). Previous studies at the Thomas Jefferson National Accelerator Facility (JLab) in Virginia, USA, have already measured the total and differential cross section of J/? near-threshold photoproduction on the free proton. This thesis presents the first measurements of J/? near-threshold photoproduction on the bound proton and bound neutron in a deuteron target. The CEBAF Large Acceptance Spectrometer at 12 GeV (CLAS12) based at JLab?s Hall B uses a 11 GeV electron beam impinging on a fixed liquid deuteron target. J/? is then produced via the exchange of a quasi-real photon and decays to a lepton pair which is detected along-side the recoil nucleon by CLAS12. Analysis procedures and in particular machine learning based techniques were developed in order to correctly identify final state particles and select J/? photoproduction events. The total and differential cross section of J/? near-threshold photoproduction on the bound proton and bound neutron were then measured from the detected J/? photoproduction events. The measurements of the cross sections on the bound proton and bound neutron agree well within their statistical uncertainty. This is consistent with the assumed two-gluon exchange production mechanism which is isospin invariant. Overall a first measurement of the J/? near-threshold photoproduction cross sections on the bound proton and bound neutron was achieved. A better understanding of the mechanical properties of the nucleon, such as pressure and mass distributions, can be obtained by relating J/? production to the nucleon GFFs. This opens the way for exciting new insights into the internal structure of the nucleon, and in particular of the nucleon?s gluonic content. An upcoming overhaul of the CLAS12 reconstruction will increase the reconstruction efficiency and the statis- tical precision of the preliminary measurements described in this thesis, with an expected gain in statistics of at least 50%. Future upgrades at JLab will allow to test some of the theoretical assumptions made in relating J/? near-threshold photoproduction to the nucleon GFFs

Tyson, Richard↗

Nuclear data for reactor production of 131 Ba and 133 Ba

The newest radioisotope for brachytherapy treatment of prostate cancer is 131 Cs (t 1/2 = 9.69 d, 100% EC). Generated via electron capture decay of 131 Ba (t 1/2 = 11.6 d, 100% EC), 131 Cs has been used in brachytherapy for prostate cancer since 2004. The 131 Ba parent is produced through neutron capture of enriched 130 Ba in a nuclear reactor. For large-scale production of 131 Ba, an accurate knowledge of production and burnup cross sections of 131 Ba are essential. Here, we report two group cross sections (thermal and resonance integrals) for 130 Ba and 131 Ba and a new measure of the half-life of 131 Ba. Targets consisting of milligram quantities of enriched 130Ba (~35%) were irradiated in Oak Ridge National Laboratory's High Flux Isotope Reactor at thermal and resonance neutron fluxes of (1.9–2.1) × 10 15 and (5.8–7.0) × 10 13 neutrons·cm -2 s -1 , respectively, for durations ranging from 3 to 26 days. In addition, cadmium covered samples of 130 Ba were irradiated for 1 hour at 12.6% full reactor power (10.7 MW). The yield of 131 Ba approaches a saturation value of ~60 GBq (~1.6 Ci) per mg of 130 Ba for 20 days irradiation at a thermal neutron flux of 1.8 × 10 15 n·s -1 ·cm -2 , with a thermal/epithermal ratio of ~30. Under the above experimental conditions, the two group cross sections of 130 Ba are 6.9 ± 0.5 b (thermal, σ 0 ) and 173 ± 7 b (resonance, I 0 ). These values represent the sum of cross sections to metastable and ground states of 131 Ba. For 131 Ba, the empirically measured thermal cross section is 200 ± 50 b assuming an I 0 /σ 0 of 10. This cross section is reported for the first time. Further, the half-life of 131 Ba was remeasured to be 11.657 ± 0.008 d. Lastly, this study also resulted in the co-production of 133 Ba (t 1/2 = 10.52 y, 100% EC). The experimental yield of 133 Ba is ~370 MBq (~10 mCi) per mg of 132 Ba (thin target) for one cycle irradiation in the High Flux Isotope Reactor, and measured two-group 132 Ba cross sections are 7.2 ± 0.2 b and 39.9 ± 1.3 b. These values also represent the sum of cross sections to metastable and ground states of 133 Ba.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transfer reactions in 206 $\mathrm{Pb}$ + 118 $\mathrm{Sn}$: From quasielastic to deep-inelastic processes

Here, we measured multinucleon transfer reactions for the 206 Pb+ 118 Sn system at E lab =1200 MeV by employing the large solid angle magnetic spectrometer PRISMA. Differential and total cross sections and Q-value distributions have been obtained for a variety of neutron and proton pick-up and stripping channels. The Q-value distributions show how the quasi-elastic and deep inelastic processes depend on the mass and charge of the transfer products. The corresponding cross sections have been compared with calculations performed with the GRAZING code. An overall good agreement is found for most of the few nucleon transfer channels. The underestimation of the data for channels involving a large number of transferred nucleons indicates that more complicated processes populate the given isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quasi-differential neutron induced neutron emissions from 235 U, and 239 Pu

Uncertainty in nuclear reaction cross sections, angular distributions, and other nuclear data directly impact how well simulations of nuclear systems represent physical observations. Here, to determine how well the nuclear data in ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0 evaluations describe the physical behaviour of 235 U, and 239 Pu when subjected to a neutron flux, the neutron emission spectrum was measured for carbon, 93.0% 235 U, and 93.9% 239 Pu samples, and compared against detailed MCNP6 simulations. The measurements were performed at the Los Alamos Neutron Science Center using a quasi-differential method previously developed at Rensselaer Polytechnic Institute. The measurement spanned 0.82–20 MeV and 30–150 degrees. The measurements show there are a significant number of discrepancies between library predictions of the neutron yield and physical observation. A few of the main discrepancies found are described in this paper. Based on these results a new evaluation utilizing these results for carbon, 235 U, and 239 Pu is recommended.

235U↗

Deuteration Effects on the Physical and Optoelectronic Properties of Donor–Acceptor Conjugated Polymers

The significant differences in scattering cross sections between deuterium and protium are unique to neutron scattering techniques and have been a long-standing area of interest within the neutron scattering community. Researchers have explored selective deuteration to manipulate scattering contrast in soft matter systems, leading to the widespread use of deuterium labeling in materials development. As deuteration changes the atomic mass, it alters physical properties such as molecular volume, polarizability, and polarity, which in turn may affect noncovalent interactions and crystal ordering. Despite previous studies, there remains a limited understanding of how deuteration impacts donor–acceptor (DA) conjugated polymers. To address this, we synthesized deuterated DPP polymers and systematically investigated the effects of side-chain deuteration on their thermal stability, crystal packing, morphology, and optoelectronic properties. We found that deuteration increased the melting and crystallization temperatures of DPP polymers, although it did not significantly alter their morphology, molecular packing, or charge mobility. These properties were assessed by using atomic force microscopy (AFM), X-ray scattering, and thin-film transistor device measurements, respectively, for DPP polymers. Our work shows that deuterium labeling could be a powerful method for controlling scattering length density, enabling neutrons to study the structure and dynamics of conjugated polymers without impacting their electronic performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exclusive dimuon production in ultraperipheral Pb+Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV with ATLAS

Exclusive dimuon production in ultraperipheral collisions (UPC), resulting from photon-photon interactions in the strong electromagnetic fields of colliding high-energy lead nuclei, PbPb(γγ) → μ + μ - (Pb (*) Pb (*) ), is studied using $\mathcal{L}$ int = 0.48 nb -1 of $\sqrt{s_{NN}}$ = 5.02 TeV lead-lead collision data at the LHC with the ATLAS detector. Dimuon pairs are measured in the fiducial region p T,μ >4 GeV, |η μ |<2.4, invariant mass m μμ >10 GeV, and p T,μμ <2 GeV. The primary background from single-dissociative processes is extracted from the data using a template fitting technique. Differential cross sections are presented as a function of m μμ , absolute pair rapidity (|y μμ |), scattering angle in the dimuon rest frame (| cos $\mathscr{O}$$^{*}_{μμ}$|), and the colliding photon energies. The total cross section of the UPC γγ → μ + μ - process in the fiducial volume is measured to be $σ^{μμ}_{fid}$ = 34.1 ± 0.3(stat.) ± 0.7(syst.) μb. Generally good agreement is found with calculations from STARlight, which incorporate the leading-order Breit-Wheeler process with no final-state effects, albeit differences between the measurements and theoretical expectations are observed. In particular, the measured cross sections at larger |y μμ | are found to be about 10–20% larger in data than in the calculations, suggesting the presence of larger fluxes of photons in the initial state. Modification of the dimuon cross sections in the presence of forward and/or backward neutron production is also studied and is found to be associated with a harder incoming photon spectrum, consistent with expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment

The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c 2 . The most stringent limit is set for spin-independent scattering at 36 GeV/c 2 , rejecting cross sections above 9.2×10 –48 cm 2 at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nanoscale Consequences of Irradiation Investigated by RAD-AFM (Final Report)

To assess the feasibility of measuring material property changes induced by ion irradiation one pristine and three legacy HT-9 samples were sectioned and polished. The polish protocol was first optimized using a pristine unirradiated HT-9 sample before polishing the ion irradiated samples as the spot size was small and repeated polishing could remove the ion irradiated region entirely. AFM tapping mode was used to assess the surface quality after each polish. AFM based hardness mapping was optimized for new diamond tips specifically for use with the HT-9 samples to compensate for differences in grain size, precipitates, and heterogeneity of hardness relative to past samples. In addition, a hardness calibration protocol was developed using NIST copper, nickel, and steel reference materials. Co-located SEM-EDS and AFM analysis was used to verify the ion irradiated edge using the silver/tungsten coating as a fiducial mark. Once benchmarked, the hardness across the ion irradiated cross section, a comparison of bulk hardness according to neutron irradiation, and the hardness of the ion irradiated surface edge was measured.

36 MATERIALS SCIENCE↗

Verification of EvaluateFLux Utility Program

The EvaluateFlux program is a post-processing utility program for DIF3D, specifically DIF3D-VARIANT which handles Cartesian and hexagonal geometries. The EvaluateFlux program was developed to allow users to obtain flux and power traverses through the geometry domain, and its initial purpose was to facilitate foil analysis by evaluating the flux solution from DIF3D-VARIANT and combining it with foil cross section data. The EvaluateFlux program can calculate the neutron flux, as well as the reaction rates, at any user provided evaluation point. It does this by identifying the spatial mesh associated with the evaluation point and then evaluates the polynomial based neutron flux moments stored in the NHFLUX file at that point. The output of EvaluateFlux varies depending on the input setup. The maximum output includes the neutron flux and microscopic and macroscopic reaction rates at each evaluation point. The purpose of this work is to verify the outputs of EvaluateFlux. Simple models that have hand calculatable results are first defined and used to verify the EvaluateFlux outputs. More complex cases are then added where a duplicate program of EvaluateFlux that uses PrintTables outputs of the binary files is used to verify the EvaluateFlux outputs. In those complex cases, hand calculations of selected evaluation points were also displayed to confirm the software verification. For all the tests done, the hand calculations agreed well with those calculated by EvaluateFlux. For the larger complex problems, the duplicate program that can process hundreds of evaluation points was able to identify that zero points within some meshes have large errors. This aspect was attributed to the truncation error on the input provided to the duplicate program and is not a concern for the accuracy of the EvaluateFlux software.

97 MATHEMATICS AND COMPUTING↗

Verification of the EvaluateFlux Utility Program

The EvaluateFlux program is a post-processing utility program for DIF3D, specifically DIF3D-VARIANT which handles Cartesian and hexagonal geometries. The EvaluateFlux program was developed to allow users to obtain flux and power traverses through the geometry domain, and its initial purpose was to facilitate foil analysis by evaluating the flux solution from DIF3D-VARIANT and combining it with foil cross section data. The EvaluateFlux program can calculate the neutron flux, as well as the reaction rates, at any user provided evaluation point. It does this by identifying the spatial mesh associated with the evaluation point and then evaluates the polynomial based neutron flux moments stored in the NHFLUX file at that point. The output of EvaluateFlux varies depending on the input setup. The maximum output includes the neutron flux and microscopic and macroscopic reaction rates at each evaluation point. The purpose of this work is to verify the outputs of EvaluateFlux. Simple models that have hand calculatable results are first defined and used to verify the EvaluateFlux outputs. More complex cases are then added where a duplicate program of EvaluateFlux that uses PrintTables outputs of the binary files is used to verify the EvaluateFlux outputs. In those complex cases, hand calculations of selected evaluation points were also displayed to confirm the software verification. For all the tests done, the hand calculations agreed well with those calculated by EvaluateFlux. For the larger complex problems, the duplicate program that can process hundreds of evaluation points was able to identify that zero points within some meshes have large errors. This aspect was attributed to the truncation error on the input provided to the duplicate program and is not a concern for the accuracy of the EvaluateFlux software.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nonelastic nuclear reactions and accompanying gamma radiation

Several aspects of nonelastic nuclear reactions which proceed through the formation of a compound nucleus are dealt with. The full statistical model and the partial statistical model are described and computer programs based on these models are presented along with operating instructions and input and output for sample problems. A theoretical development of the expression for the reaction cross section for the hybrid case which involves a combination of the continuum aspects of the full statistical model with the discrete level aspects of the partial statistical model is presented. Cross sections for level excitation and gamma production by neutron inelastic scattering from the nuclei Al-27, Fe-56, Si-28, and Pb-208 are calculated and compared with avaliable experimental data.

Snow, R.↗

Nuclear fission fragment excitation of electronic transition laser media

Specific characteristics of the media including density, excitation rates, wavelength, kinetics, fissile material, scale size, and medium uniformity are assessed. The use of epithermal neutrons, homogeneously mixed fissile material, and special high cross section nuclear isotopes to optimize coupling of the energy to the medium are shown to be important considerations maximizing the scale size, energy deposition, and medium uniformity. It is demonstrated that e-beam excitation can be used to simulate nuclear pumping conditions to facilitate the search for candidate media.

Lorents, D. C.↗

Structure of the Neutron with Quasi-Elastic Scattering from 3H and 3HE

The magnetic form factor characterizes the magnetic distribution inside the neutron and knowledge of it is essential for the understanding of the neutron structure. The E12-11-112 experiment aimed to measure the neutron magnetic form factor (GnM) from the 3H/3He cross sections ratio, in the Q2 range of 0.5 - 3 GeV2. Quasi-elastic (QE) electron scattering was used to probe nucleons on the nucleus of the mirror 3H and 3He nuclei, in Hall A at the Thomas Jefferson National Accelerator Facility (JLab). The use of the mirror nuclei ratio is a novel extraction that cancels several systematic uncertainties from the cross section effects in the ratio. The motivation of this measurement is the disagreement between the precision measurements among the Q2 range of 0.5 - 1 GeV2 in the worldwide data. A total of five Q2 points were taken between this region and four more were taken with a Q2>1 GeV2 in order to estimate the accuracy of the method. Ideally, the 3H/3He ratio should be enough to calculate the magnetic form factor, but due to nuclear effects, there will be a correction of up to 8 % depending on the Q2 value that has to be evaluated before the form factor extraction. The cross sections were measured with a point-to-point uncertainty of 3 - 4.5 %, and the ratios were also evaluated with an uncertainty of 1.5 - 3 %. Therefore, the preliminary studies of the Gn M are summarized, and from the present analysis, it can be concluded that the precision of the measurement in the region of interest will be of the order of 1.5%.

Santiesteban, Sandra↗

Estimating List-Mode Data Sensitivities to Nuclear Data with MCNP6

Nuclear data are a vital component of predictive simulations used in applications like experiment design, stockpile stewardship, nuclear nonproliferation/safeguards, health physics, and criticality safety. A singular simulation requires the coalescence of different areas of nuclear data such as cross sections, angular distributions, and energy distributions of emitted neutrons for different materials and energy ranges. Improving nuclear data and thus reducing the uncertainty in simulated parameters could enable smaller, better-informed safety factors and ultimately reduce operational and procedural costs. There is a constant effort to garner a better understanding of the physical quantities represented by nuclear data through experiments. Integral experiment benchmarks use simulated and measured results to validate current nuclear data values. In the past, benchmarks primarily focused on the effective multiplication factor (k eff ); however, this limited scope has caused compensating errors and areas of nuclear data that lack validation. Compensating errors are inaccuracies in nuclear data that are obfuscated by cancellation when observing integrated values such as k eff . Diverse integral benchmark experiments that look for quantities of interest other than k eff and include multiple responses minimize the possibility of compensating errors and provides validation to areas of nuclear data previously lacking experimental validation. Benchmark experiments can be optimized during the design process to be highly dependent on specific areas of nuclear data. The dependence of a response in an experiment to a specific area/type of nuclear data is defined as sensitivity. A larger sensitivity means that nuclear data uncertainties will play a larger role in the response(s) resulting in larger bias. Currently, the sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®1 ) transport code are limited to responses of k eff and tallied values (e.g., flux, surface current). As a part of the EUCLID project, this work explores estimating list-mode nuclear data sensitivities that can be used to design experiments aimed to constrain and reduce compensating errors in nuclear data by focusing on responses other than k eff . Tallied values are ideal quantities that are estimated with detectors during experiments. List-mode data (a list of neutron collection times) are the direct output of detector systems in subcritical neutron noise experiments. Expanding MCNP sensitivity capabilities to include the sensitivity of responses estimated from list-mode data, such as the prompt neutron decay constant (α) and multiplicity estimates (S and D), enables more direct comparison of simulated and measured experimental quantities. Additionally, deterministic tools such as SENSMG are capable of obtaining sensitivities to a wide variety of responses; however, these tools cannot handle complex geometries due to the assumptions made in discretizing the phase-space variables of the Boltzman transport equation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗

Proton Distribution Radii of 16–24 O: Signatures of New Shell Closures and Neutron Skin

The root mean square radii of the proton density distribution in 16–24 O derived from measurements of charge changing cross sections with a carbon target at ~900A MeV together with the matter radii portray thick neutron skin for 22–24 O despite 22,24 O being doubly magic. Imprints of the shell closures at N=14 and 16 are reflected in local minima of their proton radii that provide evidence for the tensor interaction causing them. The radii agree with ab initio calculations employing the chiral NNLO sat interaction, though skin thickness predictions are challenged. Furthermore, shell model predictions agree well with the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗