Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Nonlinear interfaces for acceleration-commanded control of spacecraft and manipulators

Nominal command generation in real time for the control of manipulators or of maneuvering spacecraft is hampered by the nonlinearity of the equations of motion. Likewise the real time tracking of a computed nominal trajectory in the presence of disturbances requires the computation of time-varying Jacobians of the motion. An alternative approach is the formulation of acceleration-commanded control laws in appropriately chosen generalized advantageous to design dedicated circuit interfaces to perform the required transformation. It is also possible to guarantee that actuator and sensor saturation limits are not exceeded, by means of feedback-biased circuits that implement automatic overload limitation of acceleration commands. Recent developments following this 'hardware computation' point of view will be discussed.

Dwyer, T. A. W., III↗

An investigation of motion base cueing and G-seat cueing on pilot performance in a simulator

The effect of G-seat cueing (GSC) and motion-base cueing (MBC) on performance of a pursuit-tracking task is studied using the visual motion simulator (VMS) at Langley Research Center. The G-seat, the six-degree-of-freedom synergistic platform motion system, the visual display, the cockpit hardware, and the F-16 aircraft mathematical model are characterized. Each of 8 active F-15 pilots performed the 2-min-43-sec task 10 times for each experimental mode: no cue, GSC, MBC, and GSC + MBC; the results were analyzed statistically in terms of the RMS values of vertical and lateral tracking error. It is shown that lateral error is significantly reduced by either GSC or MBC, and that the combination of cues produces a further, significant decrease. Vertical error is significantly decreased by GSC with or without MBC, whereas MBC effects vary for different pilots. The pattern of these findings is roughly duplicated in measurements of stick force applied for roll and pitch correction.

Mckissick, B. T.↗

Toward Submillimeter Accuracy in the Management of Intrafraction Motion: The Integration of Real-Time Internal Position Monitoring and Multileaf Collimator Target Tracking

Purpose: We report on an integrated system for real-time adaptive radiation delivery to moving tumors. The system combines two promising technologies-three-dimensional internal position monitoring using implanted electromagnetically excitable transponders and corresponding real-time beam adaptation using a dynamic multileaf collimator (DMLC). Methods and Materials: In a multi-institutional academic and industrial collaboration, a research version of the Calypso position monitoring system was integrated with a DMLC-based four-dimensional intensity-modulated radiotherapy delivery system using a Varian 120-leaf multileaf collimator (MLC). Two important determinants of system performance-latency (i.e., elapsed time between target motion and MLC response) and geometric accuracy-were investigated. Latency was quantified by acquiring continuous megavoltage X-ray images of a moving phantom (with embedded transponders) that was tracked in real time by a circular MLC field. The latency value was input into a motion prediction algorithm within the DMLC tracking system. Geometric accuracy was calculated as the root-mean-square positional error between the target and the centroid of the MLC aperture for patient-derived three-dimensional motion trajectories comprising two lung tumor traces and one prostate trace. Results: System latency was determined to be approximately 220 milliseconds. Tracking accuracy was observed to be sub-2 mm for the respiratory motion traces and sub-1 mm for prostate motion. Conclusion: We have developed and characterized a research version of a novel four-dimensional delivery system that integrates nonionizing radiation-based internal position monitoring and accurate real-time DMLC-based beam adaptation. This system represents a significant step toward achieving the eventual goal of geometrically ideal dose delivery to moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2017 Western Passage Tidal Energy Resource Characterization Measurements

These data are from tidal resource characterization measurements collected between April and July 2017 in Western Passage near Eastport, Maine, USA. The dataset contains the following four sub-datasets, each of which is described in more detail in the README.pdf. 1. A bottom-mounted Teledyne RDI Workhorse 600 kHz acoustic Doppler current profiler (ADCP) was deployed at 44.92015 N, 66.98915 W in ~50 m of water from 3 April to 18 July (106 days). Data were recorded in 6-minute increments in the ENU (East, magnetic North, Up) coordinate system with bin-mapping enabled. 2. A bottom-mounted Nortek Signature 500 kHz ADCP was deployed at 44.92192 N, 66.98913 W in ~50 m of water from 4 April to 18 July (105 days). Data were sampled and recorded at 2 Hz and recorded in the ENU (East, magnetic North, Up) coordinate system. 3. Between those stations along a cross-channel transect, a Stable Tidal Turbulence Mooring (STTM) positioned ~10 m above the seabed was deployed for one week during a spring tide. The STTM was outfitted with two Nortek Vector acoustic Doppler velocimeters equipped with inertial motion units (ADVs), a bottom-tracking downward-looking Teledyne RDI Workhorse 600 kHz ADCP to provide motion-corrected flow and turbulence characteristics at high temporal resolution, and an upward-looking Teledyne RDI Sentinel V20 ADCP. The STTM was deployed at 44.92098 N, 66.98922 W from 24-31 May. 4. A vessel-mounted Teledyne RDI Workhorse 300 kHz ADCP collected current data along three transects over two days, 4-5 April. The data processing used DOLfYN version 0.11.2. All hdf5 files (i.e., files ending in `.h5`) contained here can be opened using that version of DOLfYN (e.g., `dat = dolfyn.load('')`). All distances are in meters (e.g., depth, range, MLLW, hab, eta, z_), and all velocities in m/s. See the DOLfYN documentation https://lkilcher.github.io/dolfyn/), and/or the Nortek and Teledyne RDI documentation for additional details. Additional details on the dataset can be found in the README.pdf, including: - Format details of each data file. - How to regenerate the data-processing (using the files in the `wp2017_processing.zip` archive).

16 TIDAL AND WAVE POWER↗

SU-C-BRF-05: Design and Geometric Validation of An Externally and Internally Deformable, Programmable Lung Motion Phantom

Purpose: Most clinically-deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating, tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are rigid-exterior+rigid-interior or rigid-exterior+deformable-interior. Neither class adequately represents the human anatomy, which is deformable internally as well as externally. We describe the construction and experimental validation of a more realistic, externally- and internally-deformable, programmable lung phantom. Methods: The outer shell of a commercially-available lung phantom (RS- 1500, RSD Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A 3-axis platform was programmed with sinusoidal and six patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam ‘diaphragm’ that compressed/decompressed the phantom interior. Experimental characterization comprised of mapping the superior-inferior (SI) and anterior-posterior (AP) trajectories of external and internal radioopaque markers with kV x-ray fluoroscopy and correlating these with optical surface monitoring using the in-room VisionRT system. Results: The phantom correctly reproduced the programmed motion as well as realistic effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.4 mm RMS error for internal as well as external markers. The motion trajectories of internal and external markers as measured by fluoroscopy were found to be highly correlated (R=0.97). Furthermore, motion trajectories of arbitrary points on the deforming phantom surface, as recorded by the VisionRT system also showed a high correlation with respect to the fluoroscopically-measured trajectories of internal markers (R=0.92). Conclusion: We have developed a realistic externally- and internally-deformable lung phantom that will serve as a valuable tool for clinical QA and motion management research. This work was supported through funding from the NIH and VisionRT Ltd. Amit Sawant has research funding from Varian Medical Systems, VisionRT and Elekta.

60 APPLIED LIFE SCIENCES↗

Man-in-the-loop study of filtering in airborne head tracking tasks

A human-factors study is conducted of problems due to vibrations during the use of a helmet-mounted display (HMD) in tracking tasks whose major factors are target motion and head vibration. A method is proposed for improving aiming accuracy in such tracking tasks on the basis of (1) head-motion measurement and (2) the shifting of the reticle in the HMD in ways that inhibit much of the involuntary apparent motion of the reticle, relative to the target, and the nonvoluntary motion of the teleoperated device. The HMD inherently furnishes the visual feedback required by this scheme.

Lifshitz, S.↗

Electromagnetically-tracked free-mass gravitational wave antennas

The response to a gravitational wave of two free masses whose relative motion is monitored with an electromagnetic tracking signal is derived. The results indicate a two-feature signature in one-way data and a three-feature signature in two-way data. The effect is applied to gravitational wave experiments using laser interferometers, spacecraft Doppler tracking, planetary ranging, and pulsar timing analysis. Actual results are presented from spacecraft Doppler experiments and from pulsar timing data analysis, with new upper limits being set on a possible cosmic gravitational wave background via the pulsar data.

Hellings, R. W.↗

Smoothing of respiratory motion traces for motion-compensated radiotherapy

Purpose: The CyberKnife system has been used successfully for several years to radiosurgically treat tumors without the need for stereotactic fixation or sedation of the patient. It has been shown that tumor motion in the lung, liver, and pancreas can be tracked with acceptable accuracy and repeatability. However, highly precise targeting for tumors in the lower abdomen, especially for tumors which exhibit strong motion, remains problematic. Reasons for this are manifold, like the slow tracking system operating at 26.5 Hz, and using the signal from the tracking camera ''as is''. Since the motion recorded with the camera is used to compensate for system latency by prediction and the predicted signal is subsequently used to infer the tumor position from a correlation model based on x-ray imaging of gold fiducials around the tumor, camera noise directly influences the targeting accuracy. The goal of this work is to establish the suitability of a new smoothing method for respiratory motion traces used in motion-compensated radiotherapy. The authors endeavor to show that better prediction--With a lower rms error of the predicted signal--and/or smoother prediction is possible using this method. Methods: The authors evaluated six commercially available tracking systems (NDI Aurora, PolarisClassic, Polaris Vicra, MicronTracker2 H40, FP5000, and accuTrack compact). The authors first tracked markers both stationary and while in motion to establish the systems' noise characteristics. Then the authors applied a smoothing method based on the a trous wavelet decomposition to reduce the devices' noise level. Additionally, the smoothed signal of the moving target and a motion trace from actual human respiratory motion were subjected to prediction using the MULIN and the nLMS{sub 2} algorithms. Results: The authors established that the noise distribution for a static target is Gaussian and that when the probe is moved such as to mimic human respiration, it remains Gaussian with the exception of the FP5000 and the Aurora systems. The authors also showed that the proposed smoothing method can indeed be used to filter noise. The signal's jitter dropped by as much as 95% depending on the tracking system employed. Subsequently, the 3D prediction error (rms) for a prediction horizon of 150 ms on a synthetic signal dropped by up to 37% when using a normalized LMS prediction algorithm (nLMS{sub 2}) and hardly changed when using a MULIN algorithm. When smoothing a real signal obtained in our laboratory, the improvement of prediction was similar: Up to 30% for both the nLMS{sub 2} and the best MULIN algorithm. The authors also found a noticeable increase in smoothness of the predicted signal, the relative jitter dropped by up to 95% on the real signal, and on the simulated signal. Conclusions: In conclusion, the authors can say that preprocessing of marker data is very useful in motion-compensated radiotherapy since the quality of prediction increases. This will result in better performance of the correlation model. As a side effect, since the prediction of a preprocessed signal is also less noisy, the authors expect less robot vibration resulting in better targeting accuracy and less strain on the robot gears.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Models for the Effects of G-seat Cuing on Roll-axis Tracking Performance

Including whole-body motion in a flight simulator improves performance for a variety of tasks requiring a pilot to compensate for the effects of unexpected disturbances. A possible mechanism for this improvement is that whole-body motion provides high derivative vehicle state information whic allows the pilot to generate more lead in responding to the external disturbances. During development of motion simulating algorithms for an advanced g-cuing system it was discovered that an algorithm based on aircraft roll acceleration producted little or no performance improvement. On the other hand, algorithms based on roll position or roll velocity produced performance equivalent to whole-body motion. The analysis and modeling conducted at both the sensory system and manual control performance levels to explain the above results are described.

Levison, W. H.↗

New 'Molecular Movie' Reveals Ultrafast Chemistry in Motion

Scientists for the first time tracked ultrafast structural changes, captured in quadrillionths-of-a-second steps, as ring-shaped gas molecules burst open and unraveled. Ring-shaped molecules are abundant in biochemistry and also form the basis for many drug compounds. The study points the way to a wide range of real-time X-ray studies of gas-based chemical reactions that are vital to biological processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated parking garage system model

A one-twenty-fifth scale model of the key components of an automated parking garage system is described. The design of the model required transferring a vehicle from an entry level, vertically (+Z, -Z), to a storage location at any one of four storage positions (+X, -X, +Y, +Y, -Y) on the storage levels. There are three primary subsystems: (1) a screw jack to provide the vertical motion of the elevator, (2) a cam-driven track-switching device to provide X to Y motion, and (3) a transfer cart to provide horizontal travel and a small amount to vertical motion for transfer to the storage location. Motive power is provided by dc permanent magnet gear motors, one each for the elevator and track switching device and two for the transfer cart drive system (one driving the cart horizontally and the other providing the vertical transfer). The control system, through the use of a microprocessor, provides complete automation through a feedback system which utilizes sensing devices.

Collins, E. R., Jr.↗

Fitness Tracker for Weight Lifting Style Workouts

This document proposes an early, high level design for a fitness tracking system which can automatically log weight lifting style workouts. The system will provide an easy to use interface both physically through the use of several wireless wristband style motion trackers worn on the limbs, and graphically through a smartphone application. Exercise classification will be accomplished by calibration of the user’s specific motions. The system will accurately track a user’s workout, miscounting no more than one repetition in every 20, have sufficient battery life to last several hours, work with existing smartphones and have a cost similar to those of current fitness tracking devices. This document presents the mission background, current state-of-theart, stakeholders and their expectations, the proposed system’s context and concepts, implementation concepts, system requirements, first sublevel function decomposition, possible risks for the system, and a reflection on the design process.

42 ENGINEERING↗

Monitoring of Dust Devil Tracks Around the InSight Landing Site, Mars, and Comparison With In Situ Atmospheric Data

The NASA InSight mission on Mars is a unique opportunity to study atmospheric processes both from orbit and in situ observations. We use post-landing high-resolution satellite images to monitor dust devil activity during the first 8 months of the mission. We perform mapping and semiautomatic detection of newly formed dust devil tracks and analyze their characteristics (sizes, azimuths, distances, and directions of motion).We find a large number of tracks appearing shortly after landing, followed by a significant decrease of activity during late winter, then a progressive increase during early spring. New tracks are characterized by dark linear, to slightly curvilinear, traces ranging from a few to more than 10 m wide. Tracks are oriented in the ambient wind direction, according to measurements made by InSight's meteorological sensors. The systematic analysis of dust devil tracks is useful to have a better understanding of atmospheric and aeolian activity around InSight.

C. Perrin↗

A magnetospheric simulation at the space station

It is proposed that a strong magnet (terrella) be flown at or near the Space Station to create an artificial magnetosphere in a laboratory setting. The relative flow of the ionosphere past the terrella will constitute a plasma wind that will interact with the magnetic field of the terrella to produce a localized magnetosphere. This object could then be extensively studied using diagnostic probes attached to the Space Station, or with free flyers. The space and storage requirements would be minimal, since the experiment would be conducted outside the space station. The total equipment would consist of several terrella (with varying surface conductivities), approximately 3 small magnetometer/plasma diagnostic packages, and several gas canisters for upstream seeding. Power requirements would be approximately 60 watts. Several track mounted tethers, each approximately or 200 m long in length, with track parallel to the orbital motion and 100 m long, are also needed. Astronaut time needed would be minimal in the tethered configuration (approximately 4 man hours/week). A free flying configuration, while not needing the tether track, would require much more human interaction.

Lopez, R. E.↗

A magnetospheric simulation at the Space Station

It is proposed that a strong magnet (terrella) be flown at or near the Space Station to create an artificial magnetosphere in a laboratory setting. The relative flow of the ionosphere past the terrella will constitute a plasma wind that will interact with the magnetic field of the terrella to produce a localized magnetosphere. This object could then be extensively studied using diagnostic probes attached to the Space Station or with free flyers. The space and storage requirements would be minimal, since the experiment would be conducted outside the Space Station. The total equipment would consist of several terrella (with varying surface conductivities), approximately 3 small magnetometer/plasma diagnostic packages, and several gas canisters for upstream seeding. Power requirements would be approximately 60 watts. Several track mounted tethers, each approximately or 200 m long in length, with track parallel to the orbital motion and 100 m long, are also needed. Astronaut time needed would be minimal in the tethered configuration (approximately 4 man hours/week). A free flying configuration, while not needing the tether track, would require much more human interaction.

Lopez, R. E.↗

Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System

Purpose: To investigate the frequency and amplitude of baseline shift or drift (shift/drift) of lung tumors in stereotactic body radiation therapy (SBRT), using a real-time tumor-tracking radiation therapy (RTRT) system. Methods and Materials: Sixty-eight patients with peripheral lung tumors were treated with SBRT using the RTRT system. One of the fiducial markers implanted near the tumor was used for the real-time monitoring of the intrafractional tumor motion every 0.033 seconds by the RTRT system. When baseline shift/drift is determined by the system, the position of the treatment couch is adjusted to compensate for the shift/drift. Therefore, the changes in the couch position correspond to the baseline shift/drift in the tumor motion. The frequency and amount of adjustment to the couch positions in the left-right (LR), cranio-caudal (CC), and antero-posterior (AP) directions have been analyzed for 335 fractions administered to 68 patients. Results: The average change in position of the treatment couch during the treatment time was 0.45 ± 2.23 mm (mean ± standard deviation), −1.65 ± 5.95 mm, and 1.50 ± 2.54 mm in the LR, CC, and AP directions, respectively. Overall the baseline shift/drift occurs toward the cranial and posterior directions. The incidence of baseline shift/drift exceeding 3 mm was 6.0%, 15.5%, 14.0%, and 42.1% for the LR, CC, AP, and for the square-root of sum of 3 directions, respectively, within 10 minutes of the start of treatment, and 23.0%, 37.6%, 32.5%, and 71.6% within 30 minutes. Conclusions: Real-time monitoring and frequent adjustments of the couch position and/or adding appropriate margins are suggested to be essential to compensate for possible underdosages due to baseline shift/drift in SBRT for lung cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved cloud motion wind vector and altitude assignment using VAS

A CO2 cloud tracking technique to determine simultaneous heights and velocities of cloud motion winds is presented. Using animated CO2 channel imagery from VAS (Visible Infrared Spin-Scan Radiometer Atmospheric Sounder), multi-level cloud situations are separated into high, middle and low level cloud motion wind vectors by the CO2 slicing method. The VAS CO2 channel radiometric values are used in the CO2 absorption method to assign quantitative heights to the cloud vectors; cloud top pressures are determined from the ratio of the deviations in cloud produced radiances and the corresponding clear air values for three CO2 channels in a radiative transfer equation formulation. Two case studies are presented that show CO2 cloud-motion wind vectors to be in good agreement with radiosonde wind observations and CO2 cloud heights to be within a 50 mb rms deviation of radiosonde, bispectral and stereo height determinations.

Menzel, W. P.↗

Lateral control system design for VTOL landing on a DD963 in high sea states

The problem of designing lateral control systems for the safe landing of VTOL aircraft on small ships is addressed. A ship model is derived. The issues of estimation and prediction of ship motions are discussed, using optimal linear linear estimation techniques. The roll motion is the most important of the lateral motions, and it is found that it can be predicted for up to 10 seconds in perfect conditions. The automatic landing of the VTOL aircraft is considered, and a lateral controller, defined as a ship motion tracker, is designed, using optimal control techniqes. The tradeoffs between the tracking errors and the control authority are obtained. The important couplings between the lateral motions and controls are demonstrated, and it is shown that the adverse couplings between the sway and the roll motion at the landing pad are significant constraints in the tracking of the lateral ship motions. The robustness of the control system, including the optimal estimator, is studied, using the singular values analysis. Through a robustification procedure, a robust control system is obtained, and the usefulness of the singular values to define stability margins that take into account general types of unstructured modelling errors is demonstrated. The minimal destabilizing perturbations indicated by the singular values analysis are interpreted and related to the multivariable Nyquist diagrams.

Bodson, M.↗