Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device

Purpose: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). Methods and Materials: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement. Results: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm. Conclusion: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Management of Respiration-Induced Motion With 4-Dimensional Computed Tomography (4DCT) for Pancreas Irradiation

Purpose: The purposes of this study were to quantify respiration-induced organ motions for pancreatic cancer patients and to explore strategies to account for these motions. Methods and Materials: Both 3-dimensional computed tomography (3DCT) and 4-dimensional computed tomography (4DCT) scans were acquired sequentially for 15 pancreatic cancer patients, including 10 randomly selected patients and 5 patients selected from a subgroup of patients with large tumor respiratory motions. 3DCTs were fused with 2 sets of 4DCT data at the end of exhale phase (50%) and the end of inhale phase (0%). The target was delineated on the 50% and 0% phase CT sets, and the organs at risk were drawn on the 3DCT. These contours were populated to the CT sets at other respiratory phases based on deformable image registration. Internal target volumes (ITV) were generated by tracing the target contours of all phases (ITV{sub 10}), 3 phases of 0%, 20% and 50% (ITV{sub 3}), and 2 phases of 0% and 50% (ITV{sub 2}). ITVs generated from phase images were compared using percentage of volume overlap, Dice coefficient, geometric centers, and average surface distance. Results: Volume variations of pancreas, kidneys, and liver as a function of respiratory phases were small (<5%) during respiration. For the 10 randomly selected patients, peak-to-peak amplitudes of liver, left kidney, right kidney, and the target along the superior-inferior (SI) direction were 7.9 ± 3.2 mm, 7.1 ± 3.1 mm, 5.7 ± 3.2 mm, and 5.9 ± 2.8 mm, respectively. The percentage of volume overlap and Dice coefficient were 92% ± 1% and 96% ± 1% between ITV{sub 10} and ITV{sub 2} and 96% ± 1% and 98% ± 1% between ITV{sub 10} and ITV{sub 3}, respectively. The percentage of volume overlap between ITV{sub 10} and ITV{sub 3} was 93.6 ± 1.1 for patients with tumor motion >8 mm. Conclusions: Appropriate motion management strategies are proposed for radiation treatment planning of pancreatic tumors based on magnitudes of tumor respiratory motions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Intrafraction Prostate Motion on Proton Pencil Beam Scanning Delivery: A Quantitative Assessment

Purpose: To assess the dosimetric impact caused by the interplay between intrafraction prostate motion and the intermittent delivery of proton pencil beam scanning (PBS). Methods and Materials: A cohort of 10 prostate patients was treated with PBS using a bilateral single-field uniform dose (SFUD) modality. Bilateral intensity-modulated proton therapy (IMPT) plans were generated for comparison. Because beam-on time in PBS was intermittent, the actual beam-on time was determined from treatment logs. Prostate motion was generalized according to real-time Calypso tracking data from our previously reported prospective photon trial. We investigated potential dose deviations by considering the interplay effect resulting from the worst-case scenario motion and the PBS delivery sequence. Results: For both bilateral-field SFUD and IMPT plans, clinical target volume (CTV) D{sub 99}% coverage was degraded <2% owing to prostate intrafraction motion when averaged over the course of treatment, but was >10% for the worst fraction. The standard deviation of CTV D{sub 99}% distribution was approximately 1.2%. The CTV coverage of individual fields in SFUD plans degraded as time elapsed after the initial alignment, owing to prostate drift. Intensity-modulated proton therapy and SFUD demonstrated comparable results when bilateral opposed fields were used. Single-field SFUD plans that were repainted twice, which could reduce half of the treatment time, resulted in similar CTV coverage as bilateral-field plans. Conclusions: Intrafraction prostate motion affects the actual delivered dose to CTV; however, when averaged over the course of treatment, CTV D{sub 99}% coverage degraded only approximately 2% even for the worst-case scenario. The IMPT plan results are comparable to those of the SFUD plan, and similar coverage can be achieved if treated by SFUD 1 lateral field per day when rescanning the field twice to shorten the treatment time and mitigate intrafraction motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time-Adjusted Internal Target Volume: A Novel Approach Focusing on Heterogeneity of Tumor Motion Based on 4-Dimensional Computed Tomography Imaging for Radiation Therapy Planning of Lung Cancer

Purpose: To consider nonuniform tumor motion within the internal target volume (ITV) by defining time-adjusted ITV (TTV), a volume designed to include heterogeneity of tumor existence on the basis of 4-dimensional computed tomography (4D-CT). Methods and Materials: We evaluated 30 lung cancer patients. Breath-hold CT (BH-CT) and free-breathing 4D-CT scans were acquired for each patient. The tumors were manually delineated using a lung CT window setting (window, 1600 HU; level, −300 HU). Tumor in BH-CT images was defined as gross tumor volume (GTV), and the sum of tumors in 4D-CT images was defined as ITV-4D. The TTV images were generated from the 4D-CT datasets, and the tumor existence probability within ITV-4D was calculated. We calculated the TTV{sub 80} value, which is the percentage of the volume with a tumor existence probability that exceeded 80% on ITV-4D. Several factors that affected the TTV{sub 80} value, such as the ITV-4D/GTV ratio or tumor centroid deviation, were evaluated. Results: Time-adjusted ITV images were acquired for all patients, and tumor respiratory motion heterogeneity was visualized. The median (range) ITV-4D/GTV ratio and median tumor centroid deviation were 1.6 (1.0-4.1) and 6.3 mm (0.1-30.3 mm), respectively. The median TTV{sub 80} value was 43.3% (2.9-98.7%). Strong correlations were observed between the TTV{sub 80} value and the ITV-4D/GTV ratio (R=−0.71) and tumor centroid deviation (R=−0.72). The TTV images revealed the tumor motion pattern features within ITV. Conclusions: The TTV images reflected nonuniform tumor motion, and they revealed the tumor motion pattern features, suggesting that the TTV concept may facilitate various aspects of radiation therapy planning of lung cancer while incorporating respiratory motion in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differential Motion Between Mediastinal Lymph Nodes and Primary Tumor in Radically Irradiated Lung Cancer Patients

Purpose/Objective: In patients with locally advanced lung cancer, planning target volume margins for mediastinal lymph nodes and tumor after a correction protocol based on bony anatomy registration typically range from 1 to 1.5 cm. Detailed information about lymph node motion variability and differential motion with the primary tumor, however, is lacking from large series. In this study, lymph node and tumor position variability were analyzed in detail and correlated to the main carina to evaluate possible margin reduction. Methods and Materials: Small gold fiducial markers (0.35 × 5 mm) were placed in the mediastinal lymph nodes of 51 patients with non-small cell lung cancer during routine diagnostic esophageal or bronchial endoscopic ultrasonography. Four-dimensional (4D) planning computed tomographic (CT) and daily 4D cone beam (CB) CT scans were acquired before and during radical radiation therapy (66 Gy in 24 fractions). Each CBCT was registered in 3-dimensions (bony anatomy) and 4D (tumor, marker, and carina) to the planning CT scan. Subsequently, systematic and random residual misalignments of the time-averaged lymph node and tumor position relative to the bony anatomy and carina were determined. Additionally, tumor and lymph node respiratory amplitude variability was quantified. Finally, required margins were quantified by use of a recipe for dual targets. Results: Relative to the bony anatomy, systematic and random errors ranged from 0.16 to 0.32 cm for the markers and from 0.15 to 0.33 cm for the tumor, but despite similar ranges there was limited correlation (0.17-0.71) owing to differential motion. A large variability in lymph node amplitude between patients was observed, with an average motion of 0.56 cm in the cranial-caudal direction. Margins could be reduced by 10% (left-right), 27% (cranial-caudal), and 10% (anteroposterior) for the lymph nodes and −2%, 15%, and 7% for the tumor if an online carina registration protocol replaced a protocol based on bony anatomy registration. Conclusions: Detailed analysis revealed considerable lymph node position variability, differential motion, and respiratory motion. Planning target volume margins can be reduced up to 27% in lung cancer patients when the carina registration replaces bony anatomy registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection Limits and Near‐Field Ground Motions of Fast and Slow Earthquakes

Abstract We investigate theoretical limits to detection of fast and slow seismic events, and spatial variations of ground motion expected from M 6 earthquakes at short epicentral distances. The analyses are based on synthetic velocity seismograms calculated with the discrete wavenumber method assuming seismic velocities and attenuation properties of the crust in Southern California. The examined source properties include different magnitudes ( M −1.0 to M 6.0), static stress drops (0.1–10 MPa), and slow and fast ruptures (0.1–0.9 of shear wave velocity). For the M 6 events we also consider variations in rise times producing crack‐ and pulse‐type events and different rupture directivities. Slow events produce ground motion with considerably lower amplitude than corresponding regular fast earthquakes with the same magnitude, and hence are significantly more difficult to detect. The static stress drop and slip rise time also affect the maximum radiated seismic motion, and hence event detectability. Apart from geometrical factors, the saturation and depletion of seismic ground motion at short epicentral distances stem from radiation pattern, earthquake size (magnitude, stress drop), and rupture directivity. The rupture velocity, rise time, and directivity affect significantly the spatial pattern of the ground motions. The results can help optimizing detection of slow and fast small earthquakes and understand the spatial distribution of ground motion generated by large events.

58 GEOSCIENCES↗

Fast antibody fragment motion: flexible linkers act as entropic spring

A flexible linker region between three fragments allows antibodies to adjust their binding sites to an antigen or receptor. Using Neutron Spin Echo Spectroscopy we observed fragment motion on a timescale of 7 ns with motional amplitudes of about 1 nm relative to each other. The mechanistic complexity of the linker region can be described by a spring model with Brownian motion of the fragments in a harmonic potential. Displacements, timescale, friction and force constant of the underlying dynamics are accessed. The force constant exhibits a similar strength to an entropic spring, with friction of the fragment matching the unbound state. The observed fast motions are fluctuations in pre-existing equilibrium configurations. In conclusion, the Brownian motion of domains in a harmonic potential is the appropriate model to examine functional hinge motions dependent on the structural topology and highlights the role of internal forces and friction to function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and Compensation of BPM Chamber Motion in HLS

Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20{mu}m without the compensation of BPM chamber motion in the runtime.

43 PARTICLE ACCELERATORS↗

Chaotic motion of charged particles in toroidal magnetic configurations

We study the motion of a charged particle in a tokamak magnetic field and discuss its chaotic nature. Contrary to most of recent studies, we do not make any assumption on any constant of the motion and solve numerically the cyclotron gyration using Hamiltonian formalism. We take advantage of a symplectic integrator allowing us to make long-time simulations. First considering an idealized magnetic configuration, we add a nongeneric perturbation corresponding to a magnetic ripple, breaking one of the invariant of the motion. Chaotic motion is then observed and opens questions about the link between chaos of magnetic field lines and chaos of particle trajectories. Second, we return to an axisymmetric configuration and tune the safety factor (magnetic configuration) in order to recover chaotic motion. In this last setting with two constants of the motion, the presence of chaos implies that no third global constant exists, we highlight this fact by looking at variations of the first order of the magnetic moment in this chaotic setting. We are facing a mixed phase space with both regular and chaotic regions and point out the difficulties in performing a global reduction such as gyrokinetics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MAGNETIC HELICITY TRANSPORTED BY FLUX EMERGENCE AND SHUFFLING MOTIONS IN SOLAR ACTIVE REGION NOAA 10930

We present a new methodology which can determine magnetic helicity transport by the passage of helical magnetic field lines from the sub-photosphere and the shuffling motions of footpoints of preexisting coronal field lines separately. It is well known that only the velocity component, which is perpendicular to the magnetic field ({upsilon}{sub B}), has contributed to the helicity accumulation. Here, we demonstrate that {upsilon}{sub B} can be deduced from a horizontal motion and vector magnetograms under a simple relation of {upsilon}{sub t} = {mu}{sub t} + ({upsilon}{sub n}/B{sub n} ) B{sub t}, as suggested by Demoulin and Berger. Then after dividing {upsilon}{sub B} into two components, as one is tangential and the other is normal to the solar surface, we can determine both terms of helicity transport. Active region (AR) NOAA 10930 is analyzed as an example during its solar disk center passage by using data obtained by the Spectropolarimeter and the Narrowband Filter Imager of Solar Optical Telescope on board Hinode. We find that in our calculation the helicity injection by flux emergence and shuffling motions have the same sign. During the period we studied, the main contribution of helicity accumulation comes from the flux emergence effect, while the dynamic transient evolution comes from the shuffling motions effect. Our observational results further indicate that for this AR the apparent rotational motion in the following sunspot is the real shuffling motions on the solar surface.

79 ASTRONOMY AND ASTROPHYSICS↗

Near-field non-radial motion generation from underground chemical explosions in jointed granite

Here, this paper describes analysis of non-radial ground motion generated by chemical explosions in a jointed rock formation during the Source Physics Experiment (SPE). Such motion makes it difficult to discriminate between various subsurface events such as explosions, implosions (i.e. mine collapse) and earthquakes. We apply 3-D numerical simulations to understand experimental data collected during the SPEs. The joints are modelled explicitly as compliant thin inclusions embedded into the rock mass. Mechanical properties of the rock and the joints as well as the joint spacing and orientation are inferred from experimental test data, and geophysical and geological characterization of the SPE site which is dominantly Climax Stock granitic outcrop. The role of various factors characterizing the joints such as joint spacing, frictional properties, orientation and persistence in generation of non-radial motion is addressed. The joints in granite at the SPE site are oriented in nearly orthogonal directions with two vertical sets dipping at 70–80 degrees with the same strike angle, one vertical set almost orthogonal to the first two and one shallow angle joint set dipping 15 degrees. In this study we establish the relationship between the joint orientation and azimuthal variations in the polarity of the observed shear motion. The majority of the shear motion is generated due to the effects of non-elastic sliding on the joints near the source, where the wave can create significant shear stress to overcome the cohesive forces at the joints. Near the surface the joints are less confined and are subject to sliding when the pressure waves are reflected. In the far field, where the cohesive forces on the joints cannot be overcome, additional shear motion can be generated due to elastic anisotropy of the rock mass given by preferred spatial orientations of compliant joints.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A patient-specific respiratory model of anatomical motion for radiation treatment planning

The modeling of respiratory motion is important for a more accurate understanding and accounting of its effect on dose to cancers in the thorax and abdomen by radiotherapy. We have developed a model of respiration-induced organ motion in the thorax without the commonly adopted assumption of repeatable breath cycles. The model describes the motion of a volume of interest within the patient based on a reference three-dimensional (3D) image (at end expiration) and the diaphragm positions at different time points. The input data are respiration-correlated CT (RCCT) images of patients treated for non-small- cell lung cancer, consisting of 3D images, including the diaphragm positions, at ten phases of the respiratory cycle. A deformable image registration algorithm calculates the deformation field that maps each 3D image to the reference 3D image. A principal component analysis is performed to parameterize the 3D deformation field in terms of the diaphragm motion. We show that the first two principal components are adequate to accurately and completely describe the organ motion in the data of four patients. Artifacts in the RCCT images that commonly occur at the mid-respiration states are reduced in the model-generated images. Further validation of the model is demonstrated in the successful application of the parameterized 3D deformation field to RCCT data of the same patient but acquired several days later. We have developed a method for predicting respiration-induced organ motion in patients that has potential for improving the accuracy of dose calculation in radiotherapy. Possible limitations of the model are cases where the correlation between lung tumor and diaphragm position is less reliable such as superiorly situated tumors and interfraction changes in tumor-diaphragm correlation. The limited number of clinical cases examined suggests, but does not confirm, the model's applicability to a wide range of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Target motion tracking with a scanned particle beam

Treatment of moving targets with scanned particle beams results in local over- and under-dosage due to interplay of beam and target motion. To mitigate the impact of respiratory motion, a motion tracking system has been developed and integrated in the therapy control system at Gesellschaft fuer Schwerionenforschung. The system adapts pencil beam positions as well as the beam energy according to target motion to irradiate the planned position. Motion compensation performance of the tracking system was assessed by measurements with radiographic films and a 3D array of 24 ionization chambers. Measurements were performed for stationary detectors and moving detectors using the tracking system. Film measurements showed comparable homogeneity inside the target area. Relative differences of 3D dose distributions within the target volume were 1{+-}2% with a maximum of 4%. Dose gradients and dose to surrounding areas were in good agreement. The motion tracking system successfully preserved dose distributions delivered to moving targets and maintained target conformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Management of three-dimensional intrafraction motion through real-time DMLC tracking

Tumor tracking using a dynamic multileaf collimator (DMLC) represents a promising approach for intrafraction motion management in thoracic and abdominal cancer radiotherapy. In this work, we develop, empirically demonstrate, and characterize a novel 3D tracking algorithm for real-time, conformal, intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT)-based radiation delivery to targets moving in three dimensions. The algorithm obtains real-time information of target location from an independent position monitoring system and dynamically calculates MLC leaf positions to account for changes in target position. Initial studies were performed to evaluate the geometric accuracy of DMLC tracking of 3D target motion. In addition, dosimetric studies were performed on a clinical linac to evaluate the impact of real-time DMLC tracking for conformal, step-and-shoot (S-IMRT), dynamic (D-IMRT), and VMAT deliveries to a moving target. The efficiency of conformal and IMRT delivery in the presence of tracking was determined. Results show that submillimeter geometric accuracy in all three dimensions is achievable with DMLC tracking. Significant dosimetric improvements were observed in the presence of tracking for conformal and IMRT deliveries to moving targets. A gamma index evaluation with a 3%-3 mm criterion showed that deliveries without DMLC tracking exhibit between 1.7 (S-IMRT) and 4.8 (D-IMRT) times more dose points that fail the evaluation compared to corresponding deliveries with tracking. The efficiency of IMRT delivery, as measured in the lab, was observed to be significantly lower in case of tracking target motion perpendicular to MLC leaf travel compared to motion parallel to leaf travel. Nevertheless, these early results indicate that accurate, real-time DMLC tracking of 3D tumor motion is feasible and can potentially result in significant geometric and dosimetric advantages leading to more effective management of intrafraction motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography

Since coronary heart disease is one of the main causes of death all over the world, cardiac computed tomography (CT) imaging is an application of very high interest in order to verify indications timely. Due to the cardiac motion, electrocardiogram (ECG) gating has to be implemented into the reconstruction of the measured projection data. However, the temporal and spatial resolution is limited due to the mechanical movement of the gantry and due to the fact that a finite angular span of projections has to be acquired for the reconstruction of each voxel. In this article, a motion-compensated reconstruction method for cardiac CT is described, which can be used to increase the signal-to-noise ratio or to suppress motion blurring. Alternatively, it can be translated into an improvement of the temporal and spatial resolution. It can be applied to the entire heart in common and to high contrast objects moving with the heart in particular, such as calcified plaques or devices like stents. The method is based on three subsequent steps: As a first step, the projection data acquired in low pitch helical acquisition mode together with the ECG are reconstructed at multiple phase points. As a second step, the motion-vector field is calculated from the reconstructed images in relation to the image in a reference phase. Finally, a motion-compensated reconstruction is carried out for the reference phase using those projections, which cover the cardiac phases for which the motion-vector field has been determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analyzing the impact of intrafraction motion: Correlation of different dose metrics with changes in target D{sub 95%}

Purpose: A number of techniques are available to determine the dosimetric impact of intrafraction motion during intensity modulated radiation therapy (IMRT). Motion-induced dose perturbations can be determined both computationally and experimentally using a number of different dosimetric metrics. However, these measures may lead to different conclusions regarding the clinical impact of motion. This study compares the analysis of identical dose perturbations using different dosimetric metrics. Calculated changes in target D{sub 95%} are used as a reference. Methods: A total of 3768 motion-encoded dose distributions were calculated for nine lung tumor patients. The motion-encoded dose distributions were compared to static dose distributions using three dosimetric metrics: 2D {gamma}, 3D {gamma}, and histogram analysis. Each of these metrics was used to analyze dose perturbations both globally and within the target structure. Furthermore, the failing voxels were analyzed separately according to failure mode, i.e., under vs. over-dosed voxels. Metrics were evaluated based on their agreement with changes in target D{sub 95%}. Evaluations included the metrics' maximum average sensitivity and specificity (MASS) in detecting unacceptable deliveries, a coefficient correlated to ranking ({tau}), and the linear correlation coefficient, r. Results: Of the evaluated metrics, the histogram metric restricted to the under-dosed voxels within the target agreed best with changes in target D{sub 95%}. This metric achieved a MASS of 0.93, a {tau} of 0.69, and an r-value of 0.85. In comparison, the unrestricted 2D {gamma} metric achieved MASS = 0.77, {tau} = 0.40, and r = 0.67. Restricting the 2D {gamma} test both geographically and in failure mode increased the MASS to 0.85, {tau} to 0.70, and the r-value to 0.80. Conclusions: This study suggests that any clinical decisions based solely on an unrestricted 2D {gamma} metric are suboptimal. A geographic and failure mode restriction can improve results. The remaining uncertainties with non-DVH (dose volume histogram) based metrics should be kept in mind when they are used to evaluate the dosimetric impact of target motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Joint surface reconstruction and 4D deformation estimation from sparse data and prior knowledge for marker-less Respiratory motion tracking

Purpose: The intraprocedural tracking of respiratory motion has the potential to substantially improve image-guided diagnosis and interventions. The authors have developed a sparse-to-dense registration approach that is capable of recovering the patient's external 3D body surface and estimating a 4D (3D + time) surface motion field from sparse sampling data and patient-specific prior shape knowledge.Methods: The system utilizes an emerging marker-less and laser-based active triangulation (AT) sensor that delivers sparse but highly accurate 3D measurements in real-time. These sparse position measurements are registered with a dense reference surface extracted from planning data. Thereby a dense displacement field is recovered, which describes the spatio-temporal 4D deformation of the complete patient body surface, depending on the type and state of respiration. It yields both a reconstruction of the instantaneous patient shape and a high-dimensional respiratory surrogate for respiratory motion tracking. The method is validated on a 4D CT respiration phantom and evaluated on both real data from an AT prototype and synthetic data sampled from dense surface scans acquired with a structured-light scanner.Results: In the experiments, the authors estimated surface motion fields with the proposed algorithm on 256 datasets from 16 subjects and in different respiration states, achieving a mean surface reconstruction accuracy of ±0.23 mm with respect to ground truth data—down from a mean initial surface mismatch of 5.66 mm. The 95th percentile of the local residual mesh-to-mesh distance after registration did not exceed 1.17 mm for any subject. On average, the total runtime of our proof of concept CPU implementation is 2.3 s per frame, outperforming related work substantially.Conclusions: In external beam radiation therapy, the approach holds potential for patient monitoring during treatment using the reconstructed surface, and for motion-compensated dose delivery using the estimated 4D surface motion field in combination with external-internal correlation models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗