Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

624 records · Page 35

Phase Doppler Interferometry for Efficient Cloud Drop Size Distribution, Number Density, and LWC Measurements

Threats to aviation safety as a result of super-cooled large drops (SLD) has been addressed by the FAA rules change (14 CFR Part 25) with the additional icing certification requirement. SLD clouds often consist of bi-modal drop size spectra leading to significant problems in simulating and characterizing these conditions in situ and in icing wind tunnels. Legacy instrumentation for measuring drop size distributions and liquid water content are challenged under these conditions. The large size range measurement problem is addressed with the development of the Phase Doppler Interferometer, Flight Probe Dual-Range (PDI FPDR). The method is described in this report along with the measurement capabilities including the dynamic measurement range and overall working size range. The PDI instrument bases drop size measurements on the light wavelength as the measurement length scale. The light wavelength is a much more robust scale, especially as compared to the light scattering intensity. Additionally, methods for accurately characterizing the sample volume in situ based on measured drop velocity and transit time are reviewed, given the importance of this parameter for merging results and measuring LWC. Droplet coincidence in the sample volume can be problematic so this condition is treated with an innovative signal parsing approach. Measurement examples acquired in the NASA IRT are provided. Measurements of LWC showed good agreement with the Artium Particle Imaging (PI) instrument but diverged from the tunnel calibration results for larger MVD values.

42 ENGINEERING↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limited Chemotherapy and Shrinking Field Radiotherapy for Osteolymphoma (Primary Bone Lymphoma): Results From the Trans-Tasman Radiation Oncology Group 99.04 and Australasian Leukaemia and Lymphoma Group LY02 Prospective Trial;Bone; Lymphoma; Radiotherapy; Chemotherapy; Clinical trial

Purpose: To establish benchmark outcomes for combined modality treatment to be used in future prospective studies of osteolymphoma (primary bone lymphoma). Methods and Materials: In 1999, the Trans-Tasman Radiation Oncology Group (TROG) invited the Australasian Leukemia and Lymphoma Group (ALLG) to collaborate on a prospective study of limited chemotherapy and radiotherapy for osteolymphoma. The treatment was designed to maintain efficacy but limit the risk of subsequent pathological fractures. Patient assessment included both functional imaging and isotope bone scanning. Treatment included three cycles of CHOP chemotherapy and radiation to a dose of 45 Gy in 25 fractions using a shrinking field technique. Results: The trial closed because of slow accrual after 33 patients had been entered. Accrual was noted to slow down after Rituximab became readily available in Australia. After a median follow-up of 4.3 years, the five-year overall survival and local control rates are estimated at 90% and 72% respectively. Three patients had fractures at presentation that persisted after treatment, one with recurrent lymphoma. Conclusions: Relatively high rates of survival were achieved but the number of local failures suggests that the dose of radiotherapy should remain higher than it is for other types of lymphoma. Disability after treatment due to pathological fracture was not seen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal Stopping Ages for Colorectal Cancer Screening

Importance Prior studies have shown that the benefits, harms, and costs of colorectal cancer (CRC) screening at older ages are associated with a patient’s sex, health, and screening history. However, these studies were hypothetical exercises and not directly informed by data on CRC risk. Objective To identify the optimal stopping ages for CRC screening by sex, comorbidity, and screening history from a cost-effectiveness perspective. Design, Setting, and Participants This economic evaluation first validated the MISCAN-Colon (Microsimulation Screening Analysis–Colon) model against community-based CRC incidence and mortality rates for 2 subcohorts of the PRECISE (Optimizing Colorectal Cancer Screening Precision and Outcomes in Community-Based Populations) cohort. Subsequently, different CRC screening scenarios were simulated in older individuals. Cohorts of US adults aged 76 to 90 years varied by sex and comorbidity status (none, low, moderate, or severe). Statistical and sensitivity analyses were performed from March 2023 to May 2024. Exposures CRC screening histories including fecal immunochemical test (FIT) or colonoscopy, such as a negative colonoscopy result from 10, 15, 20, 25, or 30 years before the index age; 1 to 5 negative FIT results within 5 years of the index age, with different patterns of recency; or a combination of negative colonoscopy and negative FIT results. Main Outcomes and Measures The main outcomes included estimated lifetime clinical outcomes, incremental costs, and quality-adjusted life-years gained (QALYG) associated with 1 additional FIT or colonoscopy. Optimal stopping age for screening, defined as the oldest age for which the incremental cost-effectiveness ratio was still below the willingness-to-pay threshold of $\$$100 000 per QALYG, was evaluated. Results The first of the 2 PRECISE subcohorts used in validating the simulation model included 25 974 adults (15 060 females [58.0%]; 54.7% aged 76 to 80 years) with a negative colonoscopy result 10 years before the index date. The second subcohort consisted of 118 269 adults (67 058 females [56.7%]; 90.5% aged 76 to 80 years) with a negative FIT result 1 year before the index date. Older age, male sex, higher comorbidity levels, and recent CRC screenings were associated with reduced incremental benefit and cost-effectiveness of additional screening. For the reference cohort of 76-year-old females without comorbidities and a negative colonoscopy result 10 years before the index age, 1 additional colonoscopy cost $\$$38 226 per QALYG. For cohorts with otherwise equivalent characteristics, associated costs increased to $\$$1 689 945 per QALYG for females at age 90 years without comorbidities and a negative colonoscopy results 10 years before the index age, $\$$51 604 per QALYG for males at age 76 years without comorbidities and a negative colonoscopy result 10 years before the index age, and $\$$108 480 per QALYG for females at age 76 years with severe comorbidities and a negative colonoscopy result 10 years before the index age and decreased to $\$$16 870 per QALYG for females without comorbidities and a negative colonoscopy result 30 years before the index age. The optimal stopping ages across different cohorts ranged from younger than 76 to 86 years for colonoscopy and younger than 76 to 88 years for FIT. Conclusions and Relevance In this economic evaluation, age, sex, screening history, comorbidity, and future screening modality were associated with the clinical outcomes, cost-effectiveness, and optimal stopping age for CRC screening. These results can inform guideline development and patient-directed informed decision-making.

Harlass, Matthias [Erasmus Erasmus University Medi↗

Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

Development of a multi-modal Monte-Carlo radiation treatment planning system combined with PHITS

A new multi-modal Monte-Carlo radiation treatment planning system is under development at Japan Atomic Energy Agency. This system (developing code: JCDS-FX) builds on fundamental technologies of JCDS. JCDS was developed by JAEA to perform treatment planning of boron neutron capture therapy (BNCT) which is being conducted at JRR-4 in JAEA. JCDS has many advantages based on practical accomplishments for actual clinical trials of BNCT at JRR-4, the advantages have been taken over to JCDS-FX. One of the features of JCDS-FX is that PHITS has been applied to particle transport calculation. PHITS is a multipurpose particle Monte-Carlo transport code, thus application of PHITS enables to evaluate doses for not only BNCT but also several radiotherapies like proton therapy. To verify calculation accuracy of JCDS-FX with PHITS for BNCT, treatment planning of an actual BNCT conducted at JRR-4 was performed retrospectively. The verification results demonstrated the new system was applicable to BNCT clinical trials in practical use. In framework of R and D for laser-driven proton therapy, we begin study for application of JCDS-FX combined with PHITS to proton therapy in addition to BNCT. Several features and performances of the new multimodal Monte-Carlo radiotherapy planning system are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Hypogonadism From Scatter Radiation During Pelvic Radiation in Male Patients With Rectal Cancer

Purpose: Recent studies have reported fluctuations in sex hormones during pelvic irradiation. The objective of this study was to observe the effects of radiation on hormonal profiles for two treatment modalities: conventional external beam radiotherapy (EBRT) and high-dose-rate brachytherapy (HDRBT) given neoadjuvantly for patients with rectal cancer. Methods and Materials: Routine serum follicle stimulating hormone (FSH), luteinizing hormone (LH), and testosterone levels were collected from 119 consecutive male patients receiving either EBRT, using 45.0-50.4 Gy in 25-28 fractions with concurrent 5-fluorouracil chemotherapy or HDRBT using 26 Gy in 4 fractions. Results: Thirty patients with initially abnormal profiles were excluded. Profiles included in this study were collected from 51 patients treated with EBRT and 38 patients treated with HDRBT, all of whom had normal hormonal profiles before treatment. Mean follow-up times were 17 months for the entire patient cohort-14 and 20 months, respectively-for the EBRT and HDRBT arms. Dosimetry results revealed a mean cumulative testicular dose of 1.24 Gy received in EBRT patients compared with 0.27 Gy in the HDRBT group. After treatment, FSH and LH were elevated in all patients but were more pronounced in the EBRT group. The testosterone-to-LH ratio was significantly lower (p = 0.0036) in EBRT patients for tumors in the lower third of the rectum. The 2-year hypogonadism rate observed was 2.6% for HDRBT compared with 17.6% for EBRT (p = 0.09) for tumors in the lower two thirds of the rectum. Conclusion: HDRBT allows better hormonal sparing than EBRT during neoadjuvant treatment of patients with rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis and optimization of seismic monitoring networks with Bayesian optimal experimental design

SUMMARY Monitoring networks increasingly aim to assimilate data from a large number of diverse sensors covering many sensing modalities. Bayesian optimal experimental design (OED) seeks to identify data, sensor configurations or experiments which can optimally reduce uncertainty and hence increase the performance of a monitoring network. Information theory guides OED by formulating the choice of experiment or sensor placement as an optimization problem that maximizes the expected information gain (EIG) about quantities of interest given prior knowledge and models of expected observation data. Therefore, within the context of seismo-acoustic monitoring, we can use Bayesian OED to configure sensor networks by choosing sensor locations, types and fidelity in order to improve our ability to identify and locate seismic sources. In this work, we develop the framework necessary to use Bayesian OED to optimize a sensor network’s ability to locate seismic events from arrival time data of detected seismic phases at the regional-scale. This framework requires five elements: (i) A likelihood function that describes the distribution of detection and traveltime data from the sensor network, (ii) A prior distribution that describes a priori belief about seismic events, (iii) A Bayesian solver that uses a prior and likelihood to identify the posterior distribution of seismic events given the data, (iv) An algorithm to compute EIG about seismic events over a data set of hypothetical prior events, (v) An optimizer that finds a sensor network which maximizes EIG. Once we have developed this framework, we explore many relevant questions to monitoring such as: how to trade off sensor fidelity and earth model uncertainty; how sensor types, number and locations influence uncertainty; and how prior models and constraints influence sensor placement.

58 GEOSCIENCES↗

The Dose That Works: Low Level Laser Treatment of Tendinopathy

Background: Low Level Laser Therapy (LLLT) is used in the treatment of tendon injuries. However, the clinical effectiveness of this modality remains controversial with limited agreement on the most efficacious dosage and parameter choices. Purpose: To assess the clinical effectiveness of LLLT in the treatment of tendinopathy and the validity of current dosage recommendations for treatment. Method: Medical databases were searched from inception to 1st August 2008. Controlled clinical trials evaluating LLLT as a primary intervention for any tendinopathy were included in the review. Methodological quality was classified using the PEDro scale. Appropriateness of treatment parameters were assessed using established guidelines. Results: Twenty five trials met the inclusion criteria. There was conflicting findings from multiple trials: 12 showed positive effects and 13 were inconclusive or showed no effect. Dosages used in the 12 positive studies support the existence of an effective dosage window that closely resembled current guidelines. Where pooling of data was possible, LLLT showed a positive effect size; in high quality studies of lateral epicondylitis, participants' grip strength was 9.59 Kg higher than the control group; for participants with Achilles tendinopathy, the effect was 13.6 mm less pain on a 100 mm visual analogue scale. Conclusion: This study found conflicting evidence as to the effectiveness of LLLT in the treatment of tendinopathy. However, an effective dosage window emerged showing benefit in the treatment of tendinopathy. Strong evidence exists from the 12 positive studies that positive outcomes are associated with the use of current dosage recommendations for the treatment of tendinopathy.

60 APPLIED LIFE SCIENCES↗

Predicted Rates of Secondary Malignancies From Proton Versus Photon Radiation Therapy for Stage I Seminoma

Purpose: Photon radiotherapy has been the standard adjuvant treatment for stage I seminoma. Single-dose carboplatin therapy and observation have emerged as alternative options due to concerns for acute toxicities and secondary malignancies from radiation. In this institutional review board-approved study, we compared photon and proton radiotherapy for stage I seminoma and the predicted rates of excess secondary malignancies for both treatment modalities. Methods and Material: Computed tomography images from 10 consecutive patients with stage I seminoma were used to quantify dosimetric differences between photon and proton therapies. Structures reported to be at increased risk for secondary malignancies and in-field critical structures were contoured. Reported models of organ-specific radiation-induced cancer incidence rates based on organ equivalent dose were used to determine the excess absolute risk of secondary malignancies. Calculated values were compared with tumor registry reports of excess secondary malignancies among testicular cancer survivors. Results: Photon and proton plans provided comparable target volume coverage. Proton plans delivered significantly lower mean doses to all examined normal tissues, except for the kidneys. The greatest absolute reduction in mean dose was observed for the stomach (119 cGy for proton plans vs. 768 cGy for photon plans; p < 0.0001). Significantly more excess secondary cancers per 10,000 patients/year were predicted for photon radiation than for proton radiation to the stomach (4.11; 95% confidence interval [CI], 3.22-5.01), large bowel (0.81; 95% CI, 0.39-1.01), and bladder (0.03; 95% CI, 0.01-0.58), while no difference was demonstrated for radiation to the pancreas (0.02; 95% CI, -0.01-0.06). Conclusions: For patients with stage I seminoma, proton radiation therapy reduced the predicted secondary cancer risk compared with photon therapy. We predict a reduction of one additional secondary cancer for every 50 patients with a life expectancy of 40 years from the time of radiation treatment with protons instead of photons. Proton radiation therapy also allowed significant sparing of most critical structures examined and warrants further study for patients with seminoma, to decrease radiation-induced toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Institutional Phase II Study of Proton Beam Therapy for Organ-Confined Prostate Cancer Focusing on the Incidence of Late Rectal Toxicities

Purpose: Proton beam therapy (PBT) is theoretically an excellent modality for external beam radiotherapy, providing an ideal dose distribution. However, it is not clear whether PBT for prostate cancer can clinically control toxicities. The purpose of the present study was to estimate prospectively the incidence of late rectal toxicities after PBT for organ-confined prostate cancer. Methods and Materials: The major eligibility criteria included clinical Stage T1-T2N0M0; initial prostate-specific antigen level of {<=}20 ng/mL and Gleason score {<=}7; no hormonal therapy or hormonal therapy within 12 months before registration; and written informed consent. The primary endpoint was the incidence of late Grade 2 or greater rectal toxicity at 2 years. Three institutions in Japan participated in the present study after institutional review board approval from each. PBT was delivered to a total dose of 74 GyE in 37 fractions. The patients were prospectively followed up to collect the data on toxicities using the National Cancer Institute-Common Toxicity Criteria, version 2.0. Results: Between 2004 and 2007, 151 patients were enrolled in the present study. Of the 151 patients, 75, 49, 9, 17, and 1 had Stage T1c, T2a, T2b, T2c, and T3a, respectively. The Gleason score was 4, 5, 6, and 7 in 5, 15, 80 and 51 patients, respectively. The initial prostate-specific antigen level was <10 or 10-20 ng/mL in 102 and 49 patients, respectively, and 42 patients had received hormonal therapy and 109 had not. The median follow-up period was 43.4 months. Acute Grade 2 rectal and bladder toxicity temporarily developed in 0.7% and 12%, respectively. Of the 147 patients who had been followed up for >2 years, the incidence of late Grade 2 or greater rectal and bladder toxicity was 2.0% (95% confidence interval, 0-4.3%) and 4.1% (95% confidence interval, 0.9-7.3%) at 2 years, respectively. Conclusion: The results of the present prospective study have revealed a valuable piece of evidence that PBT for localized prostate cancer can achieve a low incidence of late Grade 2 or greater rectal toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗