Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Laboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions

Concurrent measurements of methane (CH 4 ) and ethane (C 2 H 6 ) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C 2 H 6 , while the water vapor correction dominated the CH 4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH 4 and 0.35–0.37 ppb C 2 H 6 . Laboratory intercomparisons showed network compatibility within 1.2 ppb CH 4 and 0.23 ppb C 2 H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH 4 . Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH 4 and 2 ppb C 2 H 6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.

03 NATURAL GAS↗

Characterization of carbonaceous aerosols during TRACER-CAT

Absorbing aerosols (AA) have an important impact on the global radiation budget and cloud properties. The composition and properties of AA can vary substantially throughout the atmosphere, depending on the particle source and the influence of chemical aging. Uncertainties associated with the radiative effects of AA remain substantial. A key contributor to this uncertainty is understanding the extent to which coatings in general, and water uptake especially, alters absorption by AA particles and how this depends on particle composition. We deployed new and existing experimental tools during the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign in Houston, TX as part of the Carbonaceous Aerosols Thrust (CAT) to provide detailed characterization of aerosol optical, chemical, and physical properties. Our TRACER-CAT measurements complemented and expanded on the planned TRACER instrumentation, allowing for more detailed characterization of aerosol properties of relevance to cloud development (a core focus of TRACER), such as the composition of particles that can act as cloud condensation nuclei, than would otherwise be available. Our measurements have allowed for assessment of the relationship(s) between AA optical properties (with a focus on absorption) and the chemical and physical characteristics (including the mixing state of black carbon (BC) containing particles). These field observations occurred in collaboration with Los Alamos National Laboratory in summer 2022 during the TRACER intensive operating period. The instrumentation we co-deployed provided for measurement of (i) multi-wavelength dry aerosol absorption, scattering, and extinction, (ii) the size-dependent composition and abundance of sub-micron aerosol, differentiating between those particles that do and do not contain BC, (iii) BC-specific concentrations and size distributions, (iv) particle size, and (v) the first field measurements at an ARM site of the influence of RH on multi-wavelength absorption by ambient AA. We have leveraged the natural variability of the atmosphere and of aerosol sources in the Houston region to (i) specifically disentangle contributions to light absorption from BC, absorbing organic carbon (brown carbon), and coatings on BC, (ii) characterize the mixing state of BC and assess the factors that give rise to compositional differences between BC-containing and BC-free aerosol, and (iii) establish how water uptake influences absorption and how any such effect depends on particle composition and BC mixing state. Overall, our study contributed to the mission of the Atmospheric System Research program in multiple ways. Through the deployment of complementary, advanced instrumentation for characterization of a wide range of aerosol properties our work helped to maximize the scientific impact of the TRACER campaign. Our work also allowed for development of new insights into the relationship(s) between aerosol composition, hygroscopicity, and the mixing state of BC with aerosol optical properties. Through this, our work has provided knowledge that can improve understanding and model representation of aerosol processes as they affect the Earth’s radiation budget.

54 ENVIRONMENTAL SCIENCES↗

Precise Measurement of the Neutron Skin Thicknesses of 208Pb and 48Ca

Despite great leaps of development in nuclear physics over the past century, we still do not have a comprehensive understanding of nuclear structure. This is mainly due to the lack of precise knowledge of the neutron distribution inside nucleus. Electromagnetic probes are ineffective in probing neutrons, unlike their charged partners, the protons. Therefore, it is of great importance to constrain the neutron distributions experimentally. Heavy nuclei have more neutrons than protons in order to balance the repulsion between protons. In such neutron-rich nuclei, the extra neutrons are pushed out to the surface by the nuclear symmetry energy, forming the so-called ?neutron skin?. The neutron skin can be probed with a well-established experimental technique ? parity-violating electron scattering (PVES). Using the scattering of longitudinally polarized electrons by an unpolarized target, PREX-II and CREX measure the small parity-violating asymmetry in cross sections. Employing electrons with opposite helicities the weak form factor, the neutron distribution and the neutron skin thickness of the target nucleus are extracted. With excellent beam qualities and dedicated instrumentation at Jefferson Lab, the asymmetry measurements are statistics-limited. We report the results of these two high-precision measurements and their implications on broad topics, from the nuclear structures to the neutron stars.

Zhang, Weibin↗

A new neutron time-of-flight detector for yield and ion-temperature measurements in DT implosions on OMEGA

A new neutron time-of-flight (nTOF) detector for yield and ion-temperature measurements in deuterium–tritium (DT) implosions was designed, installed, and calibrated on the OMEGA Laser System. This detector was installed at θ = 46.8° from the vertical and φ = 84.9°, previously a region without other detectors, in order to decrease the uncertainty of low-mode asymmetry measurements by six other nTOF detectors. The new nTOF detector uses the “PMT only” concept [Glebov et al., Rev. Sci. Instrum. 92, 013509 (2021)] and consists of a Photek photomultiplier tube (PMT)-110 in a thin aluminum housing. There is no lead shielding in front of the PMT to allow measurements of the x-ray instrument response function of the detector. The detector is installed in the OMEGA H2-port line of sight at 9.3 m from the target chamber center in the OMEGA Target Bay and is called the H2 nTOF detector. The H2 nTOF measures DT yields in the 1 × 10 13 to 3 × 10 14 range and ion temperatures from 2 to 12 keV. H2 nTOF reduced the hotspot flow uncertainty in the z-direction from ±10 to ±8 km/s, and the uncertainty in the anisotropic flow axis from σ θ = ±26° to ±13° and σ φ = ±25° to ±21°. Here, the design details, performance, and calibration results of the H2 nTOF detector in DT implosions on OMEGA will be presented.

Laser fusion↗

The construction of large-scale structure catalogs for the Dark Energy Spectroscopic Instrument

We present the technical details on how large-scale structure (LSS) catalogs are constructed from redshifts measured from spectra observed by the Dark Energy Spectroscopic Instrument (DESI). The LSS catalogs provide the information needed to determine the relative number density of DESI tracers as a function of redshift and celestial coordinates and, e.g., determine clustering statistics. We produce catalogs that are weighted subsamples of the observed data, each matched to a weighted `random' catalog that forms an unclustered sampling of the probability density that DESI could have observed those data at each location. Precise knowledge of the DESI observing history and associated hardware performance allows for a determination of the DESI footprint and the number of times DESI has covered it at sub-arcsecond level precision. This enables the completeness of any DESI sample to be modeled at this same resolution. The pipeline developed to create LSS catalogs has been designed to easily allow robustness tests and enable future improvements. We describe how it allows ongoing work improving the match between galaxy and random catalogs, such as including further information when assigning redshifts to randoms, accounting for fluctuations in target density, accounting for variation in the redshift success rate, and accommodating blinding schemes.

79 ASTRONOMY AND ASTROPHYSICS↗

Selected micrometeorological and soil data from the Manaus ZF2 K34 eddy covariance tower for the 2015/16 El Niño event

The K34 tower site (2.609 S, 60.209 W, 130 masl), located within the Tropical Silviculture Experimental Station (EEST, also known as ZF2) research station, in an area of undisturbed tropical forest (Araújo et al. 2002). It features long term measurements using micrometeorological, eddy covariance, and soil instrumentation, among others. This dataset covers January 2012 to December 2017, and includes air temperature (TA, ℃) and air relative humidity (RH, %), measured with thermohygrometers (HC2S3, Campbell Scientific, Logan, UT, USA) deployed above the canopy at the top of the tower (at 51.1 m height), and net radiation (NETRAD, W m-2) using an NR-LITE sensor (Kipp & Zonen, Delft, Netherlands), also at the top of the tower (at 35.0 m above the canopy). The soil moisture data included here is from a soil profile located approximately 12 m from the tower, and covers the period between February 2015 and September 2016. Volumetric soil water content (SWC, m3 m-3) measurements used Water Content Reflectometers (CS655 Campbell Scientific, Logan, UT, USA) at six depths: 10 cm, 20 cm, 30 cm, 40 cm, 60 cm, and 100 cm. Data are included in .csv files, and the text file ZF2-K34_Tower_headers.txt provides descriptions of data file headers.

54 ENVIRONMENTAL SCIENCES↗

AEROICESTUDY-Colorado State University Ice Spectrometer

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0 °C down to -26 to -29 °C) of atmospheric ice nucleating particle (INP) concentrations taken at ARM's Southern Great Plains (SGP) Site Guest Instrument Facility (GIF), in Lamont, Oklahoma, during the Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY). A filter sampler was mounted approximately 6 m above ground level atop the GIF rooftop platform. Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm diameter Nuclepore polycarbonate filters were used. Filters were typically drawn for either a full day period (9AM-5PM CDT) or broken up into morning (9AM-12PM CDT) and afternoon (1PM-5PM CDT) periods. Additionally, 4 overnight filters were taken (6PM-8AM CDT). The volume of air filtered was typically between 3000 and 8000 standard liters for daily samples. After collection, filters were stored at -20 °C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurement of INPs, collected aerosol particles were re-suspended in 8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples were cooled at 0.33 °C per min and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Two-tailed, 95% confidence intervals for binomial sampling were based on Equation 2 from Agresti and Coull (1998). Aliquots of suspensions from selected samples were also heat treated (95 °C for 20 min) to denature and deactiv

54 ENVIRONMENTAL SCIENCES↗

Solar Radiation Research Laboratory (SRRL) Final Report: Fiscal Years 2019-2021

The Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m 2 ) for the United States, which is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two International Organization for Standardization (ISO)/International Electrotechincal Commission (IEC) 17025 calibration facilities that provide unique, high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop: improved methods for the calibration of solar radiometers; new standards through the ISO, the IEC, and ASTM International; models; advanced instrumentation and methods for operating solar measurement stations. The SRRL data sets are also critical for the validation of new models and data sets, such as the National Solar Radiation Database (NSRDB).

14 SOLAR ENERGY↗

Particle Flux Measurements during TRACER (TRACER PFM) (Field Campaign Report)

The purpose of this campaign was to deploy an instrument payload collocated with a suite of in situ and remote-sensing aerosol instruments at the urban site at the La Porte, Texas Municipal Airport during the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) in Houston, Texas. The payload was designed to characterize the physicochemical properties, mixing state, and size-resolved vertical fluxes of aerosols. Deployed aerosol instruments associated with the flux measurements included three condensation particle counters (CPCs) with different lower cutoff diameters ( D > 2.5 nm, D > 10 nm, and D > 40 nm), a single-particle soot photometer (SP2) measuring refractory black carbon, and a portable optical particle spectrometer (POPS) measuring the optical size distribution (~180 nm < D < ~5000 nm). A 10-m flux tower hosted a sonic anemometer (SONIC) for vertical velocity measurements. In addition, a humidified tandem differential mobility analyzer (HTDMA) was deployed to measure the growth factors and hygroscopicity parameter of 15-50 nm-sized particles in order to constrain the composition of compounds responsible for modal aerosol growth during new particle formation/growth events. Finally, a radial differential mobility analyzer (RDMA) was deployed to extend the size distribution measurement to 5 nm.

54 ENVIRONMENTAL SCIENCES↗

Study of Different Piezoelectric Material Stroke Displacement at Different Temperatures Using an SRF Cavity

Piezoelectric actuators are used for resonance control in superconducting linacs. The level of frequency compensation depends on the piezoelectric stroke displacement. In this study, the stroke displacement will be measured with a 1.3 GHz SRF cavity by measuring the frequency shift with respect to the voltage applied. The entire system was submerged in liquid helium. This study characterizes the PZT piezoelectric actuator (P-844K093) and a lithium niobate (P-844B0005) piezoelectric actuator. All these actuators were developed at Physik Instrumente (PI). The piezoelectric displacement was measured at different temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Earth Model Column Collaboratory (EMC 2 ) v1.1: an open-source ground-based lidar and radar instrument simulator and subcolumn generator for large-scale models

Abstract. Climate models are essential for our comprehensive understanding of Earth's atmosphere and can provide critical insights on future changes decades ahead. Because of these critical roles, today's climate models are continuously being developed and evaluated using constraining observations and measurements obtained by satellites, airborne, and ground-based instruments. Instrument simulators can provide a bridge between the measured or retrieved quantities and their sampling in models and field observations while considering instrument sensitivity limitations. Here we present the Earth Model Column Collaboratory (EMC2), an open-source ground-based lidar and radar instrument simulator and subcolumn generator, specifically designed for large-scale models, in particular climate models, but also applicable to high-resolution model output. EMC2 provides a flexible framework enabling direct comparison of model output with ground-based observations, including generation of subcolumns that may statistically represent finer model spatial resolutions. In addition, EMC2 emulates ground-based (and air- or space-borne) measurements while remaining faithful to large-scale models' physical assumptions implemented in their cloud or radiation schemes. The simulator uses either single particle or bulk particle size distribution lookup tables, depending on the selected scheme approach, to perform the forward calculations. To facilitate model evaluation, EMC2 also includes three hydrometeor classification methods, namely, radar- and sounding-based cloud and precipitation detection and classification, lidar-based phase classification, and a Cloud Feedback Model Intercomparison Project Observational Simulator Package (COSP) lidar simulator emulator. The software is written in Python, is easy to use, and can be straightforwardly customized for different models, radars, and lidars. Following the description of the logic, functionality, features, and software structure of EMC2, we present a case study of highly supercooled mixed-phase cloud based on measurements from the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE). We compare observations with the application of EMC2 to outputs from four configurations of the NASA Goddard Institute for Space Studies (GISS) climate model (ModelE3) in single-column model (SCM) mode and from a large-eddy simulation (LES) model. We show that two of the four ModelE3 configurations can form and maintain highly supercooled precipitating cloud for several hours, consistent with observations and LES. While our focus is on one of these ModelE3 configurations, which performed slightly better in this case study, both of these configurations and the LES results post-processed with EMC2 generally provide reasonable agreement with observed lidar and radar variables. As briefly demonstrated here, EMC2 can provide a lightweight and flexible framework for comparing the results of both large-scale and high-resolution models directly with observations, with relatively little overhead and multiple options for achieving consistency with model microphysical or radiation scheme physics.

58 GEOSCIENCES↗

Model-independent measurement of the matter-radiation equality scale in DESI 2024

The peak of the matter power spectrum, known as the turnover (TO) scale, is determined by the horizon size at the time of matter-radiation equality. This scale can serve as a standard ruler, independent of other features in the matter power spectrum, such as baryon acoustic oscillations (BAO). Here, in this work, we present the first detection of the turnover in the galaxy autopower spectrum, utilizing the distribution of quasars and luminous red galaxies (LRG) measured by the Dark Energy Spectroscopic Instrument (DESI) during its first year of survey operations in a model-independent manner. To avoid confirmation bias, we first analyze the data using data blinding methods designed for the DESI baryon acoustic oscillation, redshift space distortion and scale-dependent bias signals. We measure the angle-averaged dilation distance 𝐷 V ⁡(𝑧 = 1.651) = (38.1 ± 2.5)⁢𝑟 H from the quasars and 𝐷 V ⁡(𝑧 = 0.733) = (21.8 ± 1.0)⁢𝑟 H from the LRG sample in units of the horizon 𝑟 H at the matter-radiation-equality epoch. Combining these two constraints and assuming a flat Λ⁢CDM model with three standard neutrino species, we can translate this into a constraint of Ω m ⁢ℎ 2 = 0.13⁢9$^{+0.036}_{−0.046}$. We can break the Ω m −𝐻 0 degeneracy with low-redshift distance measurements from type-Ia supernova (SN) data from Pantheon+, we obtain a sound-horizon free estimate of the Hubble-Lemaître parameter of 𝐻 0 = 65.2$^{+4.9}_{−6.2}$ km/s/Mpc, consistent with sound-horizon dependent DESI measurements. On the other hand, combining the DESI BAO and TO, we find a truly DESI-only measurement of 𝐻 0 = 74.0$^{+7.2}_{−3.5}$ km/s/Mpc, in line with DESI-only full-shape results where the sound-horizon scale is marginalized out. This discrepancy in 𝐻 0 can be reconciled in a 𝑤 0 ⁢𝑤 𝑎 ⁢ CDM cosmology, where the combination of DESI BAO and TO data yields 𝐻 0 = 66.5 ± 7.2 km/s/Mpc.

cosmological parameters↗

Composition and Dynamical Processes of Ions in Giant Magnetospheres: The Importance of In Situ Measurements for Advancing the Current Knowledge [Slides]

In this white paper, we emphasize the importance of in situ ion composition measurements provided by plasma mass spectrometers in planetary magnetospheres (Uranus and Neptune) aimed for future planetary missions. We present our current understanding on magnetospheres of Uranus and Neptune that are largely based on Plasma Science Investigation (PLS, faraday cups) and Low Energy Charged Particle (LECP) instrument on Voyager 2 and what measurements need to be made to improve it. We emphasize that the future missions equipped with plasma mass spectrometers must visit these magnetospheres again to advance our current knowledge. Finally, this white paper summarizes key science questions that needs to be addressed which all of them requires a direct ion composition measurements from a plasma spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A New Method for Aerosol Measurement Using Wide-field Photometry

We present a new method to measure the vertical aerosol optical depth (VAOD) during clear nights using a wide-field imager—a CCD camera with a photographic lens on an equatorial mount. A series of 30 s exposures taken at different altitudes above the horizon can be used to measure the VAOD with a precision better than 0.008 optical depths within a few minutes. Such a measurement does not produce any light and is thus suitable for use at sites where other astronomical instruments are located. The precision of the VAOD measurement depends on the laboratory calibration of spectral properties of the system and of the response of the camera electronics to varying illumination levels, as well as careful considerations of the details of stellar photometry and modeling of the dependence of the measured stellar flux, the star color, and the position within the field of view. The results obtained with robotic setups at the future sites of the Cerenkov Telescope Array show good internal consistency and agreement with simultaneous measurements from a Sun/Moon photometer located at the same sites.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Redshift evolution and covariances for joint lensing and clustering studies with DESI Y1

ABSTRACT Galaxy–galaxy lensing (GGL) and clustering measurements from the Dark Energy Spectroscopic Instrument Year 1 (DESI Y1) data set promise to yield unprecedented combined-probe tests of cosmology and the galaxy–halo connection. In such analyses, it is essential to identify and characterize all relevant statistical and systematic errors. We forecast the covariances of DESI Y1 GGL + clustering measurements and the systematic bias due to redshift evolution in the lens samples. Focusing on the projected clustering and GGL correlations, we compute a Gaussian analytical covariance, using a suite of N-body and lognormal simulations to characterize the effect of the survey footprint. Using the DESI one percent survey data, we measure the evolution of galaxy bias parameters for the DESI luminous red galaxy (LRG) and bright galaxy survey (BGS) samples. We find mild evolution in the LRGs in $0.4 < z < 0.8$, subdominant to the expected statistical errors. For BGS, we find less evolution for brighter absolute magnitude cuts, at the cost of reduced sample size. We find that for a redshift bin width $\Delta z = 0.1$, evolution effects on DESI Y1 GGL is negligible across all scales, all fiducial selection cuts, all fiducial redshift bins. Galaxy clustering is more sensitive to evolution due to the bias squared scaling. Nevertheless the redshift evolution effect is insignificant for clustering above the 1-halo scale of $0.1h^{-1}$ Mpc. For studies that wish to reliably access smaller scales, additional treatment of redshift evolution is likely needed. This study serves as a reference for GGL and clustering studies using the DESI Y1 sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Weather Data from BSEC Weather Stations

This dataset provides hourly measurements of temperature, humidity, rainfall, wind, and sunlight at Ambient Weather and OttHydro stations across Baltimore city. These surface weather stations were deployed by the Baltimore Social-Environmental Collaborative (BSEC) Urban Integrated Field Laboratory (UIFL) project, funded by the Department of Energy (DOE). This dataset will be periodically updated to include more stations and recent observations when available. Data File Information This dataset contains surface weather measurements data in comma-separated value (CSV) format and documents that describe the weather stations, locations, and measured parameters and units. data/BSEC-[STATIONID]_[SENSORTYPE]_hourly_[YEAR].csv Surface weather measurements data in CSV format, where STATIONID indicates the weather station, SENSORTYPE is the type of weather station ('AWS' = Ambient Weather Station and 'OTT' = 'OttHydro Station'), and YEAR indicate the year in which the measurements were made. Example data file name: BSEC-AAC_AWS_hourly_2023.csv. documents/Station_Locations.csv This CSV file provides location information and measurement start date for each surface weather station. documents/Weather_Station_Descriptions.pdf This document provides detailed description of the instruments along with their setup and accuracy of measurement. documents/File_Parameters.pdf This document describes the surface weather parameters and units of measurement.

Ambient Weather Stations↗

Weather Data from BSEC Weather Stations

This dataset provides measurements of temperature, humidity, rainfall, wind, and sunlight at Ambient Weather and OttHydro stations across Baltimore city. These surface weather stations were deployed by the Baltimore Social-Environmental Collaborative (BSEC) Urban Integrated Field Laboratory (UIFL) project, funded by the Department of Energy (DOE). This dataset currently contains measurements from 2023 to June 2026 and will be periodically updated to include more stations and recent observations when available. Data File Information This dataset contains surface weather measurements data in comma-separated value (CSV) format and documents that describe the weather stations, locations, and measured parameters and units. data/[TIMEAVG]/[YEAR]/BSEC-[STATIONID]_[SENSORTYPE]_[TIMEAVG]_[YEAR].csv Surface weather measurements data in CSV format, where STATIONID indicates the weather station, SENSORTYPE is the type of weather station ('AWS' = Ambient Weather Station and 'OTT' = 'OttHydro Station'), TIMEAVG is time period for each entry (= daily, hourly, or 5min), and YEAR indicate the year in which the measurements were made. Example data file name: BSEC-AAC_AWS_hourly_2023.csv. documents/Station_Locations.csv This CSV file provides location information and measurement start date for each surface weather station. documents/Weather_Station_Descriptions.pdf This document provides detailed description of the instruments along with their setup and accuracy of measurement. documents/File_Contents.pdf This document describes the contents on the data files, including time notation, weather parameters and units of measurement. documents/site-metadata/[STATOINID]-metadata.pdf These PDF files provide information on weather station sites, including land cover characteristics, station mounting, and photographs. Each PDF file corresponds to one station, as indicated by STATIONID.

Ambient Weather Stations↗

PV Reference Cells for Outdoor Use: An Investigation of Calibration Factors

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as a low-cost alternative to thermopile radiometers. But reference cell characteristics differ substantially from the latter, therefore measurements made by one category of instrument cannot be substituted for or directly compared with the other. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of 39 units of 10 distinct types made by 6 manufacturers. This report compares the calibration factors provided by manufacturers - which most users rely upon - to those measured at a high level of accuracy by NREL's Cell Lab. It also reports on the application of the Broadband Outdoor Radiometer Calibration (BORCAL) method to reference cells. As a group, the factory calibrations for the crystalline silicon cells showed a small positive bias of +0.7%, with a tight distribution around this value. This is a very good result for the manufacturers. The two World Photovoltaic Scale cells constituted outliers, with a mean deviation of -0.8%, which is still within the reported uncertainty ranges. The data collected during the BORCAL procedures show a strong and systematic fluctuation of the apparent responsivity of the reference cells over the course of a day, which was anticipated. Consequently, the standard BORCAL R@45 calibration factors underestimated the reference cell responsivities by 1%-4%. An alternate responsivity indicator was developed, R'@30, incorporating adjustments for temperature response, spectral response, and directional response. This reduced the mean deviation to -0.4% compared to the Cell Lab. Further, two independent BORCAL sessions were able to produce the same values to within ±0.2%. This could be a viable approach for verifying reference cells using existing BORCAL infrastructure, for example, to evaluate their long-term stability. The daily profiles of responsivity obtained during the BORCAL sessions (provided in Appendix A) show clear patterns of differences between models, which provides evidence that their directional responses differ from each other; thus, two sensors that are calibrated correctly might give the same reading at 30° zenith angle but systematically different readings at 60°. The impact of these inconsistencies in field operation will be quantified using the long-term observations started in 2020.

14 SOLAR ENERGY↗