Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Static Measurements on HTS Coils of Fully Superconducting AC Electric Machines for Aircraft Electric Propulsion System

The NASA Glenn Research Center (GRC) has been developing the high efficiency and high-power density superconducting (SC) electric machines in full support of electrified aircraft propulsion (EAP) systems for a future electric aircraft. A SC coil test rig has been designed and built to perform static and AC measurements on BSCCO, (RE)BCO, and YBCO high temperature superconducting (HTS) wire and coils at liquid nitrogen (LN2) temperature. In this paper, DC measurements on five SC coil configurations of various geometry in zero external magnetic field are measured to develop good measurement technique and to determine the critical current (Ic) and the sharpness (n value) of the super-to-normal transition. Also, standard procedures for coil design, fabrication, coil mounting, micro-volt measurement, cryogenic testing, current control, and data acquisition technique were established. Experimentally measured critical currents are compared with theoretical predicted values based on an electric-field criterion (Ec). Data here are essential to quantify the SC electric machine operation limits where the SC begins to exhibit non-zero resistance. All test data will be utilized to assess the feasibility of using HTS coils for the fully superconducting AC electric machine development for an aircraft electric propulsion system.

superconducting motor↗

AC compensation of 3D magnetic diagnostic signals in DIII-D and National Spherical Torus Experiment-Upgrade (NSTX-U) for real-time application

A time domain algorithm has been developed to remove the vacuum pickup generated by both coil current (DC) and induced vessel current (AC) in real time from three dimensional (3D) magnetic diagnostic signals in the National Spherical Torus Experiment-Upgrade (NSTX-U) and DIII-D tokamaks. The possibility of detecting 3D plasma perturbations in real time is essential in modern and future tokamaks to avoid and control MHD instabilities. The presence of vacuum field pickup, due to toroidally asymmetric (3D) coils or to misalignment between sensors and axisymmetric (2D) coils, pollutes the measured plasma 3D field, making the detection of the magnetic field produced by the plasma challenging. Although the DC coupling between coils and sensors can be easily calculated and removed, the AC part is more difficult. Here, an algorithm based on a layered low-pass filter approach for the AC compensation and its application for DIII-D and NSTX-U data is presented, showing that this method reduces the vacuum pickup to the noise level. Comparison of plasma response measurements with and without vacuum compensation shows that accurate mode locking detection and plasma response identification require precise AC and DC compensations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Analyisi of a Self-centered Cold Mass Support for the MICE Coupling Magnet

The Muon Ionization Cooling Experiment (MICE) consists of eighteen superconducting solenoid coils in seven modules, which are magnetically hooked together since there is no iron to shield the coils and the return flux. The RF coupling coil (RFCC) module consists of a superconducting coupling solenoid mounted around four conventional conducting 201.25 MHz closed RF cavities. The coupling coil will produce up to a 2.2 T magnetic field on the centerline to keep the beam within the RF cavities. The peak magnetic force on the coupling magnet from other magnets in MICE is up to 500 kN in longitudinal direction, which will be transferred to the base of the RF coupling coil (RFCC) module through a cold mass support system. A self-centered double-band cold mass support system with intermediate thermal interruption is applied to the coupling magnet, and the design is introduced in detail in this paper. The thermal and structural analysis on the cold mass support assembly has been carried out using ANSYS. The present design of the cold mass support can satisfy with the stringent requirements for the magnet center and axis azimuthal angle at 4.2 K and fully charged.

42 ENGINEERING↗

A New PCB Rotating Coil at NSLS-II

Several R&D projects are underway at NSLS-II towards an upgrade of its storage ring with a new lattice that will use high field magnets with small bores of 16-22 mm. A large fraction of the high field magnets are expected to be of permanent magnet technology that will require precise magnetic measurements and field harmonics corrections. A new magnetic measurement bench has been built based on a printed circuit board (PCB) coil of 12 mm diameter and 270 mm active length. This PCB coil has the capabil-ity of measuring field quality to a level of 10 ppm of the main field up to the 15th harmonic with a sensitivity between 0.01 m2 and 0.02 m2 at the reference radius of 5 mm. This paper will describe the main features of the rotating coil bench and discuss the measurement results of a permanent-magnet Halbach quadrupole of 12.7 mm bore diameter.

43 PARTICLE ACCELERATORS↗

Swinging reciprocating Mach probes for the high field side scrape-off layer in DIII-D

A new pair of in situ reciprocating Mach probes termed swing probes has been deployed on the DIII-D centerpost for the 2012 experimental campaign. When not deployed, the entire assembly is housed in a <5 cm space underneath the centerpost tiles. This design is unique in that the probe swings vertically through the edge plasma, taking measurements along a 180 Degree-Sign arc with a 20 cm radius. The motion is powered by actuator coils that interact with the tokamak's magnetic field. Two electrodes maintain a Mach-pair orientation throughout the swing and provide measurements of saturation current, electron temperature, and parallel flow speeds up to the separatrix.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Lens For Plasma Engine

Low-field electromagnet coils placed downstream of plasma engine, polarized oppositely to higher-field but smaller radius coil in nozzle of engine, reduces divergence of plasma jet, thereby increasing efficiency of engine. Concept tested by computer simulation based on simplified mathematical model of plasma, engine, and coils.

Sercel, Joel C.↗

Implications of grain size variation in magnetic field alignment of block copolymer blends

Recent experiments have highlighted the intrinsic magnetic anisotropy in coil–coil diblock copolymers, specifically in poly(styrene- block -4-vinylpyridine) (PS- b -P4VP), that enables magnetic field alignment at field strengths of a few tesla. We consider here the alignment response of two low molecular weight (MW) lamallae-forming PS- b -P4VP systems. Cooling across the disorder–order transition temperature (T odt ) results in strong alignment for the higher MW sample (5.5K), whereas little alignment is discernible for the lower MW system (3.6K). This disparity under otherwise identical conditions of field strength and cooling rate suggests that different average grain sizes are produced during slow cooling of these materials, with larger grains formed in the higher MW material. Blending the block copolymers results in homogeneous samples which display T odt , d-spacings, and grain sizes that are intermediate between the two neat diblocks. Similarly, the alignment quality displays a smooth variation with the concentration of the higher MW diblock in the blends, and the size of grains likewise interpolates between limits set by the neat diblocks, with a factor of 3.5× difference in the grain size observed in high vs low MW neat diblocks. Finally, these results highlight the importance of grain growth kinetics in dictating the field response in block copolymers and suggests an unconventional route for the manipulation of such kinetics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development and Comparison of Mechanical Structures for FNAL 15 T Nb$_3$Sn Dipole Demonstrator

Main design challenges for 15 T accelerator magnets are large Lorentz forces at this field level. The large Lorentz forces generate high stresses in the coil and mechanical structure and, thus, need stress control to maintain them at the acceptable level for brittle Nb3Sn coils and other elements of magnet mechanical structure. To provide these conditions and achieve the design field in the FNAL 15 T dipole demonstrator, several mechanical structures have been developed and analysed. The possibilities and limitations of these designs are discussed in this paper

43 PARTICLE ACCELERATORS↗

Optimizing the HSX stellarator for microinstability by coil-current adjustments

Abstract The optimization of helically symmetric experiment (HSX) for reduced microinstability has been achieved by examining a large set of configurations within a neighborhood of the standard operating configuration. This entailed generating a database of more than 10 6 magnetic-field configurations for HSX by varying the currents in external coils. Using a set of volume-averaged metrics and gyrokinetic simulations, this database has helped to identify a set of configurations that can be used to regulate trapped-electron-mode stability in HSX. This set of configurations is also found to correlate flux-surface elongation and triangularity with an increase in magnetic-well depth, an increase in rotational transform, and low neoclassical heat-flux relative to the standard quasi-helically-symmetric configuration. These results demonstrate sensitivity of plasma behavior in response to changes in a 3D magnetic field to both neoclassical and gyrokinetic models, and the experimental potential in HSX to explore turbulence optimization. This perturbative optimization approach is not unique to HSX, and can readily be deployed on existing fusion devices to identify novel magnetic-fields to be used in turbulence-optimization experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identification of important error fields in stellarators using the Hessian matrix method

Error fields are predominantly attributed to inevitable coil imperfections. Controlling error fields during coil fabrication and assembly is crucial for stellarators. Excessively tight coil tolerance increases time and cost, and, in part, led to the cancellation of the National Compact Stellarator Experiment and delay of W7-X. In this paper, we improve the recently proposed Hessian matrix method to rapidly identify important coil deviations. Two of the most common figures of merit, magnetic island size and quasi-symmetry, are analytically differentiated over coil parameters. By extracting the eigenvectors of the Hessian matrix, we can directly identify sensitive coil deviations in the order of the eigenvalues. The new method is applied to the upcoming Chinese First Quasi-axisymmetric Stellarator configuration. Important perturbations that enlarge n/m = 4/11 islands and deteriorate quasi-axisymmetry of the magnetic field are successfully determined. The results suggest each modular coil should have separate tolerance and some certain perturbation combinations will produce significant error fields. By relaxing unnecessary coil tolerance, this method will hopefully lead to a substantial reduction in time and cost.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetically Diffused Radial Electric-Arc Air Heater Employing Water-Cooled Copper Electrodes

A magnetically rotated electric-arc air heater has been developed that is novel in that an intense magnetic field of the order of 10,000 to 25,000 gauss is employed. This field is supplied by a coil that is connected in series with the arc. Experimentation with this heater has shown that the presence of an intense magnetic field transverse to the arc results in diffusion of the arc and that the arc has a positive effective resistance. With the field coil in series with the arc, highly stable arc operation is obtained from a battery power supply. External ballast is not required to stabilize the arc when it is operating at maximum power level. The electrode erosion rate is so low that the airstream contamination is no more than 0.07 percent and may be substantially less.

COPPER↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrating novel stellarator single-stage optimization algorithms to design the Columbia stellarator experiment

Abstract The Columbia Stellarator eXperiment (CSX), currently being designed at Columbia University, aims to test theoretical predictions related to QA plasma behavior, and to pioneer the construction of an optimized stellarator using three-dimensional, non-insulated high-temperature superconducting (NI-HTS) coils. The magnetic configuration is generated by a combination of two circular planar poloidal field (PF) coils and two 3D-shaped interlinked (IL) coils, with the possibility to add windowpane coils to enhance shaping and experimental flexibility. The PF coils and vacuum vessel are repurposed from the former Columbia Non-Neutral Torus experiment, while the IL coils will be custom-wound in-house using NI-HTS tapes. To obtain a plasma shape that meets the physics objectives with a limited number of coils, novel single-stage optimization techniques are employed, optimizing both the plasma and coils concurrently, in particular targeting a tight aspect ratio QA plasma and minimized strain on the HTS tape. Despite the increased complexity due to the expanded degrees of freedom, these methods successfully identify optimized plasma geometries that can be realized by coils meeting engineering specifications. This paper discusses the derivation of the constraints and objectives specific to CSX, and describe how two recently developed single-stage optimization methodologies are applied to the design of CSX. A set of selected configurations for CSX is then described in detail.

Baillod, A. (ORCID:0000000303529180)↗

Tokamak DEMO-FNS: Concept of magnet system and vacuum chamber

The level of knowledge accumulated to date in the physics and technologies of controlled thermonuclear fusion (CTF) makes it possible to begin designing fusion—fission hybrid systems that would involve a fusion neutron source (FNS) and which would admit employment for the production of fissile materials and for the transmutation of spent nuclear fuel. Modern Russian strategies for CTF development plan the construction to 2023 of tokamak-based demonstration hybrid FNS for implementing steady-state plasma burning, testing hybrid blankets, and evolving nuclear technologies. Work on designing the DEMO-FNS facility is still in its infancy. The Efremov Institute began designing its magnet system and vacuum chamber, while the Kurchatov Institute developed plasma-physics design aspects and determined basic parameters of the facility. The major radius of the plasma in the DEMO-FNS facility is R = 2.75 m, while its minor radius is a = 1 m; the plasma elongation is k{sub 95} = 2. The fusion power is P{sub FUS} = 40 MW. The toroidal magnetic field on the plasma-filament axis is B{sub t0} = 5 T. The plasma current is I{sub p} = 5 MA. The application of superconductors in the magnet system permits drastically reducing the power consumed by its magnets but requires arranging a thick radiation shield between the plasma and magnet system. The central solenoid, toroidal-field coils, and poloidal-field coils are manufactured from, respectively, Nb{sub 3}Sn, NbTi and Nb{sub 3}Sn, and NbTi. The vacuum chamber is a double-wall vessel. The space between the walls manufactured from 316L austenitic steel is filled with an iron—water radiation shield (70% of stainless steel and 30% of water).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HTS Dipole Magnet Model for the Persistent Current Operation

Recent advances in the fabrication of high-temperature superconducting (HTS) coils allow the design of superconducting accelerator magnets that work in a persistent current mode. Many various, rather low-field magnets in particle accelerators operate in the DC current mode. Fermilab designed, fabricated, and tested an HTS dipole magnet model that has 20-mm air gap and a magnetic field up to 0.5 T. The magnet has a primary copper coil that for a short period pumps the energy in the short-circuited secondary HTS coil. Here, the current paper presents the design, fabrication, and testing of this magnet at liquid-nitrogen temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetized liner inertial fusion platform development to assess performance scaling with drive parameters

Magnetized liner inertial fusion (MagLIF) experiments have demonstrated fusion-relevant ion temperatures up to 3.1 keV and thermonuclear production of up to 1.1 × 1013 deuterium–deuterium neutrons. This performance was enabled through platform development that provided increases in applied magnetic field, coupled preheat energy, and drive current. Advanced coil designs with internal reinforcement enabled an increase from 10 to 20 T. An improved laser pulse shape, beam smoothing, and thinner laser entrance foils increased preheat energy coupling from less than 1 to 2.3 kJ. A redesign of the final transmission line and load region increased peak load current from 16 to 20 MA. The wider range of input parameters was leveraged to study target performance trends with preheat energy, applied magnetic field, and peak load current. Ion temperature and neutron yield generally followed trends in two-dimensional clean Lasnex calculations. Stagnation performance improved with peak load current when other input parameters were also increased such that convergence was maintained. This dataset suggests that reducing convergence to less than 30 would improve predictability of target performance. Lasnex was used to identify a simulation-optimized scaling path, which suggests 10+ kJ of fusion yield is possible on the Z facility with achievable input parameters. This path also indicates >10 MJ could be generated through volume burn on a future facility with a path to high yield (>200 MJ) using cryogenic dense fuel layers. The newly developed MagLIF platform enables exploration of both this simulation optimized scaling path and a recently developed similarity-scaling path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The PIT MkV pulsed inductive thruster

The pulsed inductive thruster (PIT) is an electrodeless, magnetic rocket engine that can operate with any gaseous propellant. A puff of gas injected against the face of a flat (spiral) coil is ionized and ejected by the magnetic field of a fast-rising current pulse from a capacitor bank discharge. Single shot operation on an impulse balance has provided efficiency and I(sub sp) data that characterize operation at any power level (pulse rate). The 1-m diameter MkV thruster concept offers low estimated engine mass at low powers, together with power capability up to more than 1 MW for the 1-m diameter design. A 20 kW design estimate indicates specific mass comparable to Ion Engine specific mass for 10,000 hour operation, while a 100,000 hour design would have a specific mass 1/3 that of the Ion Engine. Performance data are reported for ammonia and hydrazine. With ammonia, at 32 KV coil voltage, efficiency is a little more than 50 percent from 4000 to more than 8000 seconds I(sub sp). Comparison with data at 24 and 28 kV indicates that a wider I(sub sp) range could be achieved at higher coil voltages, if required for deep space missions.

Dailey, C. Lee↗

The Calculated and Measured Resistance for Splices between Conductors in a MICE Superconducting Coil

The resistance of superconducting joints within MICE coils is an important issue particularly for the coupling coils. The MICE tracker solenoids have only two superconducting joints in the three spectrometer set (end coil 1, the center coil and end coil 2). The AFC magnets may have only a single joint within the coil. The coupling coils may have as many as fifteen joints within the coil, due to relatively short piece lengths of the superconductor. LBNL and ICST looked at three types of coil joints. They are: (1) cold fusion butt joints, (2) side-by-side lap joints, and (3) up-down lap joints. A theoretical calculation of the joint resistance was done at LBNL and checked by ICST. After looking at the theoretical resistance of the three types of joints, it was decided that the cold welded butt joint was not an attractive alternative for joints within a MICE superconducting magnet coil. Side-by-side and up-down lap joints were fabricated at ICST using two types of soft solder between the conductors. These conductor joints were tested at LBNL at liquid helium temperatures over a range of magnetic fields. The joint resistance was compared with the theoretical calculations. Measurements of splice strength were also made at 300 K and 77 K.

42 ENGINEERING↗