Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Magnetization Dependent In-plane Anomalous Hall Effect in a Low-dimensional System

Anomalous Hall Effect (AHE) response in magnetic systems is typically proportional to an out-of-plane magnetization component because of the restriction imposed by system symmetries, which demands that the magnetization, applied electric field, and induced Hall current are mutually orthogonal to each other. Here, we report experimental realization of an unconventional form of AHE in a low-dimensional heterostructure, wherein the Hall response is not only proportional to the out-of-plane magnetization component but also to the in-plane magnetization component. By interfacing a low-symmetry topological semimetal (TaIrTe4) with the ferromagnetic insulator (Cr2Ge2Te6), we create a low-dimensional magnetic system, where only one mirror symmetry is preserved. We show that as long as the magnetization has a finite component in the mirror plane, this last mirror symmetry is broken, allowing the emergence of an AHE signal proportional to in-plane magnetization. Our experiments, conducted on multiple devices, reveal a gate-voltage-dependent AHE response, suggesting that the underlying mechanisms responsible for the Hall effect in our system can be tuned via electrostatic gating. A minimal microscopic model constrained by the symmetry of the heterostructure shows that both interfacial spin-orbit coupling and time-reversal symmetry breaking via the exchange interaction from magnetization are responsible for the emergence of the in-plane AHE. Our work highlights the importance of system symmetries and exchange interaction in low-dimensional heterostructures for designing novel and tunable Hall effects in layered quantum systems.

FOS: Physical sciences↗

Magnetic switching behaviors of orbital states with different magnetic quantum numbers in Au/Fe/MgO multilayer system

A spin specific magnetic hysteresis (SSMH) curve and an orbital specific magnetic hysteresis (OSMH) curve are obtained for Fe/Au/Fe/MgO multilayers by magnetic Compton scattering and SQUID magnetometer measurements. The SSMH curve with each contribution of magnetic quantum number |m| = 0, 1, and 2 states is obtained by decomposition analyses of magnetic Compton profiles. Residual magnetization is observed for the SSMH curve with magnetic quantum number |m| = 0, 2 and the OSMH curve. Although the SQUID magnetometer measurements do not show perpendicular magnetic anisotropy (PMA) in the present Fe/Au/Fe/MgO multilayer film, the SSMH curve with magnetic quantum number |m| = 0, 2 and OSMH curve show switching behaviors of PMA.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Methods and systems for low to ultra-low magnetic field nuclear magnetic resonance for detecting chemical nerve agents

A nuclear magnetic resonance (NMR) system is configured to detect chemical threat material. The system comprises a magnet configured to generate a magnetic field of about 300 millitesla or less; and a probe configured to detect nuclear relaxation of at least two nuclei selected from the group consisting of 1H, 19F, 31P and 14N, and detect the spin density of nuclei selected from the group consisting of 1H, 19F, 31P and 14N, following excitation.

Williams, Robert F.↗

Methods and systems for J-coupled nuclear magnetic resonance

A nuclear magnetic resonance (NMR) system is configured to detect combinatorial signatures stemming from homonuclear and heteronuclear J-couplings. The system comprises a pre-polarization system, a detector, and NMR electronics, wherein the detector includes an NMR magnet with a magnetic field of strength between 300 mT and 10 μT.

Williams, Robert F.↗

Vertical Magnetic Measurements of the First Full-Length Prototype MQXFAP2 Quadrupole for the LHC Hi-Lumi Accelerator Upgrade Project

This paper reports the commissioning of the vertical magnetic measurement system and the room temperature (warm) and cryogenic (cold) magnetic field measurements of the first full-length (4.2 m) quadrupole built by the U.S. Accelerator Upgrade Project (AUP) (formerly the LARP collaboration) for the high luminosity upgrade of the Large Hadron Collider at CERN. The magnet, designated MQXFAP2, is a prototype preceding production for the AUP which will provide ten sets of 8.4-m superconducting insertion region quadrupoles for the Hi-Lumi Upgrade. The quadrupoles will be built by assembling two 4.2-m magnets in a single cryostat. Agreement between Brookhaven National Laboratory's (BNL's) and Lawrence Berkeley National Laboratory's (LBNL's) warm measurement data has indicated that the upgraded vertical magnetic measurement system at Brookhaven National Laboratory is ready for MQXFA magnet production testing. Lastly, the cold magnetic measurement has been performed and preliminary data analysis has been conducted.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploring New Resin Systems for Nb3Sn Accelerator Magnets

Epoxy resins have long been a focus of magnet design. They provide strength and stability to the superconductor, to allow coil fabrication and consistent magnet performance. They are often cited as a main contributor to magnet performance, often as a limiting factor, from epoxy cracking and energy release. New resin systems are being designed to improve magnet quench and training performance through several means. Baseline candidate resin systems are evaluated for neat resin mechanical properties as well as behavior in Nb 3 Sn subscale composites. Furthermore, this data feeds additional resin system tuning to meet the goals stated above.

43 PARTICLE ACCELERATORS↗

Features of obtaining diluted magnetic semiconductors in the system of narrow-gap GaInAsSb alloys

Nanotechnology of obtainment of diluted magnetic semiconductors based on the GaInAsSb compounds is developed using the laser deposition of Mn atoms on the surface of the epitaxial layer of a quaternary alloy obtained by liquid-phase epitaxy. Fabricated heterostructures were studied using high-resolution X-ray diffraction for the Bragg and grazing diffraction geometries, and the layer-by-layer analysis is performed by secondary-ion mass spectrometry. It is established that the near-boundary region of the Ga{sub 0.96}In{sub 0.04}As{sub 0.11}Sb{sub 0.89} layer near the deposition surface of atomic Mn exhibits the presence of a quinary compound with Mn atoms in the lattice and Mn{sub 3}As{sub 2}-type binary inclusions. Saturation of the GaIn(Mn)AsSb multicomponent diluted semiconductor with the Mn compounds makes it possible to specify the concentration of the magnetic impurity in the crystal and control the magnetic properties of the heterostructure.

36 MATERIALS SCIENCE↗

Derivation of low-energy Hamiltonians for heavy-fermion materials

Here, by utilizing a multiorbital periodic Anderson model with parameters obtained from ab initio band structure calculations, combined with degenerate perturbation theory, we derive effective Kondo-Heisenberg and spin Hamiltonians that capture the interaction among the effective magnetic moments. This derivation encompasses fluctuations via both nonmagnetic 4⁢𝑓 0 and magnetic 4⁢𝑓 2 virtual states, and its accuracy is confirmed through comparison with experimental data obtained from CeIn 3 . The significant agreement observed between experimental results and theoretical predictions underscores the potential of deriving minimal models from first-principles calculations for achieving a quantitative description of 4⁢𝑓 materials. Moreover, our microscopic derivation unveils the underlying origin of anisotropy in the exchange interaction between Kramers doublets, shedding light on the conditions under which this anisotropy may be weak compared to the isotropic contribution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Relaxation measurements of an MRI system phantom at low magnetic field strengths

Abstract Objective Temperature controlled T 1 and T 2 relaxation times are measured on NiCl 2 and MnCl 2 solutions from the ISMRM/NIST system phantom at low magnetic field strengths of 6.5 mT, 64 mT and 550 mT. Materials and methods The T 1 and T 2 were measured of five samples with increasing concentrations of NiCl 2 and five samples with increasing concentrations of MnCl 2 . All samples were scanned at 6.5 mT, 64 mT and 550 mT, at sample temperatures ranging from 10 °C to 37 °C. Results The NiCl 2 solutions showed little change in T 1 and T 2 with magnetic field strength, and both relaxation times decreased with increasing temperature. The MnCl 2 solutions showed an increase in T 1 and a decrease in T 2 with increasing magnetic field strength, and both T 1 and T 2 increased with increasing temperature. Discussion The low field relaxation rates of the NiCl 2 and MnCl 2 arrays in the ISMRM/NIST system phantom are investigated and compared to results from clinical field strengths of 1.5 T and 3.0 T. The measurements can be used as a benchmark for MRI system functionality and stability, especially when MRI systems are taken out of the radiology suite or laboratory and into less traditional environments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-energy synchrotron flares powered by strongly radiative relativistic magnetic reconnection: 2D and 3D PIC simulations

ABSTRACT The time evolution of high-energy synchrotron radiation generated in a relativistic pair plasma energized by reconnection of strong magnetic fields is investigated with 2D and 3D particle-in-cell (PIC) simulations. The simulations in this 2D/3D comparison study are conducted with the radiative PIC code OSIRIS, which self-consistently accounts for the synchrotron radiation reaction on the emitting particles, and enables us to explore the effects of synchrotron cooling. Magnetic reconnection causes compression of the plasma and magnetic field deep inside magnetic islands (plasmoids), leading to an enhancement of the flaring emission, which may help explain some astrophysical gamma-ray flare observations. Although radiative cooling weakens the emission from plasmoid cores, it facilitates additional compression there, further amplifying the magnetic field B and plasma density n, and thus partially mitigating this effect. Novel simulation diagnostics utilizing 2D histograms in the n-B space are developed and used to visualize and quantify the effects of compression. The n-B histograms are observed to be bounded by relatively sharp power-law boundaries marking clear limits on compression. Theoretical explanations for some of these compression limits are developed, rooted in radiative resistivity or 3D kinking instabilities. Systematic parameter-space studies with respect to guide magnetic field, system size, and upstream magnetization are conducted and suggest that stronger compression, brighter high-energy radiation, and perhaps significant quantum electrodynamic effects such as pair production, may occur in environments with larger reconnection-region sizes and higher magnetization, particularly when magnetic field strengths approach the critical (Schwinger) field, as found in magnetar magnetospheres.

Schoeffler, K. M. (ORCID:0000000276447381)↗

Visualization of Multi-Dimensional Imaging Data for the DIII-D National Fusion Facility

With funding provided from the Office of Fusion Energy Science’s program on Diagnostic Systems for Magnetic Fusion Energy Sciences, the PI and his team have pioneered the development of microwave imaging systems for magnetic fusion plasma diagnostics. Specifically, electron cyclotron emission (ECE) imaging [1], a passive radiometric technique, measures electron temperature fluctuations; and microwave imaging reflectometry (MIR) [2], an active radar imaging technique, measures electron density fluctuations. These microwave imaging diagnostic instruments developed by UC Davis have made important contributions to fusion science in a relatively short period of time from their original installation on DIII-D. The microwave imaging diagnostic technique has matured considerably since the beginning of a fruitful collaboration with DIII-D and PPPL, and has also been adopted at preeminent tokamak facilities worldwide. As discussed in detail in the following, this has continued with the development of revolutionary microwave diagnostic instruments employing monolithic millimeter wave integrated circuit (MMIC) system-on-chip (SoC) technology. Specifically, “chip” receivers mounted in liquid crystal polymer (LCP) modules have been demonstrated to dramatically improve the performance of the electron cyclotron emission imaging (ECEI) system including: 30x improvement in noise temperature thereby permitting absolute 2-D electron temperature images, outstanding shielding against out-of-band interference including microwave bursting which had plagued previous ELM studies using the old quasi-optical mini-lens ECEI system, and independent modules facilitating flexible repair and replacement. Under the “Visualization of multi-dimensional imaging data for the DIII-D National Fusion Facility” program, funding was provided for a research scientist postdoc and a Ph.D. student to support physics studies at DIII-D employing these instruments. This endeavor is synergistic with our current grant under the DOE Fusion Energy Sciences (FES) program on Diagnostic Systems for Magnetic Fusion Energy Sciences. This support considerably increased the scientific output of the diagnostics. The activities were strongly focused in the areas of pedestal and ELM stability, energetic particle confinement, and the early detection and avoidance of tokamak disruptions employing the microwave imaging diagnostic instruments developed under the advanced diagnostics program where imaging of the ELM crash was made possible by the elimination of the interference from the associated microwave “bursts”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic resonance control of spin-correlated radical pair dynamics in vivo

Magnetic fields can influence reactions involving spin-correlated radical pairs (SCRPs). This provides a mechanism by which both static and time-varying magnetic fields can affect living systems at the biomolecular level. However, an engineered SCRP system conferring magnetic sensitivity to a non-native biochemical process in a multicellular organism has not yet been demonstrated. Here, in this study, we demonstrate control of SCRP dynamics using magnetic resonance in a live transgenic animal. We show that the emission of various red fluorescent proteins (RFPs), in the presence of a flavin cofactor, can be modified by a combination of static and radiofrequency magnetic fields applied near the electron spin resonance frequency. This effect was measured at room temperature both in vitro and in the nematode Caenorhabditis elegans, genetically modified to express the RFP mScarlet. These observations suggest that the magnetic field effects measured in RFP-flavin systems are due to quantum-correlated radical pairs with a coherence time larger than 4 ns. Our experiments demonstrate that radiofrequency magnetic fields can influence dynamics of reactions involving SCRPs in vivo, potentially enabling new methods for remotely controlling biomolecular processes, such as gene expression, and suggest broader potential for quantum tools in biology.

Burd, Shaun C. [Stanford Univ., CA (United States)↗

Low field magnetic resonance imaging

A method and system of magnetic resonance imaging does not need a large homogenous field to truncate a gradient field. Spatial information is encoded into the spin magnetization by allowing the magnetization to evolve in a non-truncated gradient field and inducing a set of 180 degree rotations prior to signal acquisition.

Pines, Alexander↗

Magnetic levitation

A magnetic levitation system is described, including a first cylinder-shaped magnet; a second cylinder-shaped magnet coaxially aligned with the first cylinder-shaped magnet; and a first cavity coaxially aligned with the first cylinder-shaped magnet; wherein the surfaces of the like-poles of the first and second cylinder-shaped magnets are parallel to each other and face each other to result in a linear magnetic field between the first and the second magnets. Methods of using a magnetic levitation system for analyzing a diamagnetic or paramagnetic sample are also described.

Ge, Shencheng↗

Multimodal correlative study of Hall transport and magnetic phases in Fe/Gd multilayer systems

The Fe/Gd multilayer system hosts a number of magnetic phases, such as stripe, mixed stripe and skyrmion, skyrmion lattice, and isolated skyrmions for a wide range of temperature and magnetic field. We report different Hall transport signals in a Fe/Gd system through multimodal correlative resonant soft x-ray scattering (RSXS), Hall effect, magneto-optic Kerr effect, and transmission x-ray microscopy measurements. The simultaneous nature of the RSXS and Hall transport measurements allowed us to accurately connect various features in the transport data with the specific magnetic phases. We found that the topological Hall effect (THE) shows peaks with opposite signs, which we attribute to two different mechanisms. Our multimodal correlative study indicates that the sign reversal in THE occurs when the system transforms to and from a skyrmion lattice and low density isolated skyrmion phases. We propose that the skyrmion lattice contributes to the THE through a Berry phase induced emergent magnetic field mechanism in one case, and a skew scattering mechanism corresponding to the isolated low density skyrmion state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methods and apparatus for making magnetic skyrmions

A system and a method for the deterministic generation of magnetic skyrmions includes a magnetic strip configured to store and transport skyrmions. The magnetic strip includes one or more spatial inhomogeneities configured to generate a skyrmion at known locations when excited by a current pulse. A current pulse generator is used to inject current pulses into the magnetic strip via contact pads electrically coupled to both the current pulse generator and the magnetic strip. The system also includes a magnetic field source to apply an out-of-plane magnetic field across the magnetic strip to facilitate generation of skyrmions. Skyrmions can be generated by applying an out-of-plane magnetic field to the magnetic strip and injecting a current pulse with sufficient current density towards the spatial inhomogeneities. Once a skyrmion is generated, another current pulse with sufficient current density can be injected to move the skyrmion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic microscopic imaging with an optically pumped magnetometer and flux guides

Here, by combining an optically pumped magnetometer (OPM) with flux guides (FGs) and by installing a sample platform on automated translation stages, we have implemented an ultra-sensitive FG-OPM scanning magnetic imaging system that is capable of detecting magnetic fields of ~20 pT with spatial resolution better than 300 μm (expected to reach ~10 pT sensitivity and ~100 μm spatial resolution with optimized FGs). As a demonstration of one possible application of the FG-OPM device, we conducted magnetic imaging of micron-size magnetic particles. Magnetic imaging of such particles, including nano-particles and clusters, is very important for many fields, especially for medical cancer diagnostics and biophysics applications. For rapid, precise magnetic imaging, we constructed an automatic scanning system, which holds and moves a target sample containing magnetic particles at a given stand-off distance from the FG tips. We show that the device was able to produce clear microscopic magnetic images of 10 μm-size magnetic particles. In addition, we also numerically investigated how the magnetic flux from a target sample at a given stand-off distance is transmitted to the OPM vapor cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Nonlinear Dynamics of Intense Charged Particle Beams in the Paul Trap Simulator Experiment

The Paul Trap Simulator Experiment (PTSX) is a compact laboratory device that simulates the nonlinear dynamics of intense charged particle beams propagating over a large distance in an alternating-gradient magnetic transport system. The radial quadrupole electric eld forces on the charged particles in the Paul Trap are analogous to the radial forces on the charged particles in the quadrupole magnetic transport system. The amplitude of oscillating voltage applied to the cylindrical electrodes in PTSX is equivalent to the quadrupole magnetic eld gradient in accelerators. The temporal periodicity in PTSX corresponds to the spatial periodicity in magnetic transport system. This thesis focuses on investigations of envelope instabilities and collective mode excitations, properties of high-intensity beams with significant space-charge effects, random noise-induced beam degradation and a laser-induced-fluorescence diagnostic. To better understand the nonlinear dynamics of the charged particle beams, it is critical to understand the collective processes of the charged particles. Charged particle beams support a variety of collective modes, among which the quadrupole mode and the dipole mode are of the greatest interest. We used quadrupole and dipole perturbations to excite the quadrupole and dipole mode respectively and study the effects of those collective modes on the charge bunch. The experimental and particle-in-cell (PIC) simulation results both show that when the frequency and the spatial structure of the external perturbation are matched with the corresponding collective mode, that mode will be excited to a large amplitude and resonates strongly with the external perturbation, usually causing expansion of the charge bunch and loss of particles. Machine imperfections are inevitable for accelerator systems, and we use random noise to simulate the effects of machine imperfection on the charged particle beams. The random noise can be Fourier decomposed into various frequency components and experimental results show that when the random noise has a large frequency component that matches a certain collective mode, the mode will also be excited and cause heating of the charge bunch. It is also noted that by rearranging the order of the random noise, the adverse effects of the random noise may be eliminated. As a non-destructive diagnostic method, a laser-induced- fluorescence (LIF) diagnostic is developed to study the transverse dynamics of the charged particle beams. The accompanying barium ion source and dye laser system are developed and tested.

LIF↗