Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Interface‐Controlled Redox Chemistry in Aqueous Mn 2 ⁺/MnO₂ Batteries

Manganese dioxide (MnO 2 ) deposition/dissolution (Mn 2+ /MnO 2 ) chemistry, involving a two-electron-transfer process, holds promise for safe and eco-friendly large-scale energy storage. However, challenges like electrode/electrolyte interface environment fluctuations (H + and H 2 O activity), irreversible Mn degradation, and limited understanding of degradation mechanisms hinder the reversibility of the Mn 2+ /MnO 2 conversion. This study demonstrates a vanadyl/pervanadyl (VO 2+ /VO 2 + ) redox-mediated interface designed for high-energy Mn 2+ /MnO 2 batteries. Unlike flow systems, this work uncovers, for the first time, the mechanism of a static redox-mediated interface in regulating interfacial H + and H 2 O activities. Significantly, the VO 2+ /VO 2 + chemical redox mediation targets Mn 3+ intermediates, suppressing their hydrolysis and enabling 100% Mn 2+ /MnO 2 conversion. The redox-mediated interface enhances the Mn redox electron transfer process, achieving a stable ≈95% coulombic efficiency and ultrahigh capacity of 100 mAh cm −2 with an areal energy density of 111 mWh cm −2 , outperforming flow systems. The electrode also exhibits an average specific capacity of 593 mAh g −1 , approaching the theoretical limit of 616 mAh g −1 , and a specific energy density of 721 Wh kg −1 at high MnO 2 loadings (50–150 mg cm −2 ). Furthermore, the findings highlight the critical role of interfacial redox mediation in regulating H + and H 2 O activities and underscore the significance of interface dynamics.

Xue, Xinzhe [University of California, Santa Cruz,↗

X-ray imaging of liquid-liquid Mg cavitation

The coupling of dynamic loading platforms with synchrotron light sources have enabled experiments examining void formation in optically opaque materials. Much like spallation in a solid, cavitation occurs when rarefaction waves collide within a liquid. The resulting deformation leads to a complex flow field with numerous voids. It has been suggested that compaction of such a structure may be a significant source of ejecta (i.e. shallow bubble collapse). Experiments imaging supported and unsupported shocks interacting with a free surface in shock melted Mg with synchrotron radiation are presented. Here, the results are used to examine the structure of a cavitation plane that forms in the unsupported case and provide an estimate of the porosity within this region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Active liquid crystals powered by force-sensing DNA-motor clusters

Significance Single-molecule techniques have elucidated how isolated molecular motors generate piconewton forces with unprecedented detail. However, in diverse biological and synthetic settings, force-generating proteins collectively power nonequilibrium dynamics, including continuous large-scale rearrangements and persistent fluid flows. Characterizing motor-generated forces in these dense and dynamical environments remains a challenge. We assembled a reversible DNA-based force-sensing probe that, by an optical readout, reveals the molecular arrangements and the force loads experienced by kinesin motors. These probes provide insight into motor-generated forces that collectively power the unique dynamics of microtubule-based active nematics, a noteworthy example of an internally driven active matter system. DNA-based force probes can be extended to study forces and stresses in various synthetic systems as well as diverse cellular environments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced Multi-Tube Mixer Combustion for 65% Efficiency (Final Report)

This project targeted advanced low NOx combustion for advanced gas turbines capable of 65%, or greater, efficiency in combined cycle application. This technology advancement has further potential to benefit gas turbines used in coal based IGCC applications with pre-combustion carbon capture and hydrogen as the resulting fuel. The program developed and synthesized the most advanced combustion system capable of achieving low NOX emissions up to turbine inlet temperatures of 3100F while also supporting the load-following needs of a modern grid. The combustion system contributes to the overall gas turbine efficiency goal by setting the maximum cycle temperature achievable for a given NOX level and by minimizing the through-combustor air flow pressure drop. Focus areas for this project targeted maximizing the turbine inlet temperature entitlement, as constrained by emissions considerations. The design also minimized parasitic air flow pressure drop by using advanced cooling techniques and performance materials selections and by minimizing hot surface area. These two technology objectives (maximum, emissions-compliant cycle temperature and minimum air flow pressure drop) were integrated into a prototype design. The primarily analytical project sought to identify the most promising technologies to meet these objectives. Additional critical “jugular” data were obtained from multi-tube mixer tests to realize the potential of leveraging “micro flames” for minimizing overall hot surface area. This data was used, in conjunction with an understanding of advanced material and cooling design technologies, to analytically develop multiple design concepts. Phase I focused on in-depth engineering analysis and design, with minimal supporting laboratory testing to enable a selection of the top three combustion architectures for achieving these overall objectives. Phase II of the program developed the selected design through a combination of sub-scale testing and analytical efforts. Early tests included a cold-flow cascade to establish aerodynamic performance characteristics and a sub-scale fired test at GE Global Research in Niskayuna, NY, to establish cooling and heat transfer characteristics in conjunction with combustion performance. The data from these tests validated the analytical models to ultimately design a full-scale, test article to evaluate at prototypical pressure and temperature conditions at GE Gas Power’s Gas Turbine Technology Laboratory in Greenville, SC. GE Gas Power also developed, tested, and recommended a suitable seal design to be applied to the unique features of the combustor. To assess the technology challenges from prospective future production of the combustor from a ceramic matrix composite material, screening tests of Environmental Barrier Coatings were completed.

20 FOSSIL-FUELED POWER PLANTS↗

Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems

The large thermal gradients and high subsurface temperatures of the western region of the U.S. hold great potential for the implementation of enhanced geothermal systems (EGS). The development of these potential EGS resources requires stimulation of the reservoir to enhance permeability and it has been widely reported that a substantial amount of water will be required should conventional hydraulic stimulation be used. This presents a huge challenge and a high risk to the geothermal development because the water stress1 in these areas is already high or extremely high. The use of foam, a gas/liquid mixture predominantly composed of gas, in fracturing is considered and explored in this project as a potential approach to address water concerns with hydraulic stimulation in the development of EGS. This project, led by Oak Ridge National Laboratory (ORNL) in collaboration with Temple University, was awarded in an open lab call in 2018, and was part of the DOE GTO waterless stimulation initiative. The goal of the project was to demonstrate the feasibility of foam fracturing for EGS development through two primary tasks: Task 1: Laboratory study of the effectiveness of foam fracturing for representative geological materials, including cyclic pressurization using foam (led by ORNL) and Task 2: High temperature foam material selection and characterization (led by Temple University). In FY19, ORNL finished the critical review on serval issues associated with foam fracturing and the implementation of the proposed tasks in a lab study (Wang, et al., 2019), and completed the foam fracturing testing using cement as a model material (Wang, et al, 2020a). The work at ORNL was geared up to develop a brand-new foam testing system in FY20. The purchase of main components for the new system was finished in the first half of the FY20. The assembly of the foam testing system and foam fracturing testing were completed in the second half of the FY20 (Wang, et al., 2021a). Task 1 required the development of a test system which can be used to perform hydraulic fracturing of geological specimens with both water and foamed liquids at pressure up to 6,000 psi (41.4 MPa). The system possesses several capabilities that conventional injection systems lack for hydraulic fracturing. In addition to its ability to generate foam with controlled quality, it is capable of cycling pressure levels between specified values up to frequencies of 50 Hz. The latter capability was developed to evaluate the hypothesis that cyclic loading of samples would produce enhanced fracturing. The system consists of two sections: one for foam generation and another for foam injection. The foam is generated through separate control and pressurization of liquid and gas phases with controlled flow rates. The injection section is equipped with a low-flow Coriolis flow that monitors the density of foam to ensure the injection is in the range of target foam quality2. Experimental results of foam fracturing are reported for cylindrical granite specimens using water and aqueous N2 foam as the fracturing fluids. All experiments were performed for unconfined conditions. The effects of injection mode (i.e., monotonic vs cyclic pressurization) on breakdown pressure and failure response sample were investigated using water alone as a fracturing fluid and foams with a range of compositions. It was found that in the case of monotonic injection, the breakdown pressure of granite specimens tended to be slightly higher when fracturing with foam. Additionally, with a foam quality of 90%, the water use can be reduced by 50 to 84%, depending on hole size. On the other hand, it was observed that the breakdown pressure can be brought down to 70% of the monotonic breakdown pressure by using low cycle fatigue. Finally, discussions are presented regarding injectivity and water use reduction.

15 GEOTHERMAL ENERGY↗

Preparing large area of thermochromic nanocomposite films for smart window application

The challenges posed by high building energy bill necessitate proactive implementation of energy-efficient strategies to minimize the uses of both electricity and heating gas and promote the use of free solar energy sources. "Smart" window films/glass, leveraging thermochromic vanadium dioxide (VO 2 ), offer an adaptive approach to harness solar energy, significantly reducing the thermal load of buildings. This is achieved by reflecting the infrared portion of the solar spectrum through a phase transition in the monoclinic M-phase (M) of VO 2 induced by heating. In this study, a scalable continuous flow synthesis process invented by Argonne was employed to explore a wide parameter space, targeting the controlled synthesis of monoclinic VO 2 (M) nanoparticles with well-controlled sizes and morphologies. Additionally, a doping strategy and surface modifications were utilized for high-throughput tuning of the metal-to-insulator transition temperature. Strategies to enhance the solar modulation properties of VO 2 nanoparticles in polymer films were investigated through (i) morphological transformation from spherical to nanorod structures, (ii) surface modification with low refractive index ligands, and (iii) incorporation of additional thermochromic materials for improved solar energy modulation and aesthetically appealing colors in smart films. Furthermore, the study outlines scaling-up synthesis methods for VO 2 nanoparticles in a continuous flow reactor using hydrazine monohydrate. This comprehensive investigation provides valuable insights into the upscaling synthesis and design of advanced VO 2 /polymer composite smart window films with enhanced functionality, solar energy modulation and visible light transmittance, driving the technology a step close for industrial application.

14 SOLAR ENERGY↗

Gas cooled faraday rotator and method

To enable several orders of magnitude increases in average power and energy handling capability of Faraday rotators, the technology utilizes high speed gas cooling to efficiently remove thermal loading from the Faraday optic faces while minimizing the thermal wavefront and thermal birefringence by creating a longitudinal thermal gradient. A recirculating gas cooling manifold accelerates the gas over the surface of the slab to create a turbulent flow condition which maximizes the surface cooling rate. The technology further provides a spatially uniform thermal profile on the Faraday slabs.

Bayramian, Andrew J.↗

Transmission-distribution long-term volt-var planning considering reactive power support capability of distributed PV

High penetration of grid-edge, inverter-based photovoltaic (PV) can cause significant voltage fluctuations not only at the distribution but also at the sub-transmission levels due to PV output intermittency. Traditional reactive power planning approaches do not consider intermittency, nor the possibility of coordinating the control of existing and future volt-ampere reactive resources. This paper proposes a reactive power planning tool for sub-transmission systems to mitigate voltage violations and fluctuations caused by high PV penetration and intermittency with a minimum investment cost. The planning tool coordinates with an optimization-based volt-var operational tool for: a) modeling the coordination of all existing var assets in both sub-transmission and distribution systems to reduce the need of new equipment, and b)selecting a set of scenarios with voltage violations, derived from PV intermittency c) testing the final investment decision. The tool obtains an investment need for each intermittency scenario with a proposed optimal power-flow framework with efficient techniques to handle a high number of discrete variables. Two options are provided for final planning decision: i) a conservative direct combination of investment need solutions and ii) a machine learning-based selection of representative investment needs at most time steps. The final investment decision options are verified using a realistic large-scale sub-transmission system and 5-minute PV and load data. The results show a significant voltage performance improvement with a lower investment cost for additional var equipment compared to conventional approaches.

14 SOLAR ENERGY↗

A Reinforcement Learning Approach to Parameter Selection for Distributed Optimal Power Flow

With the increasing penetration of distributed energy resources, distributed optimization algorithms have attracted significant attention for power systems applications due to their potential for superior scalability, privacy, and robustness to a single point-of-failure. The Alternating Direction Method of Multipliers (ADMM) is a popular distributed optimization algorithm; however, its convergence performance is highly dependent on the selection of penalty parameters, which are usually chosen heuristically. In this work, we use reinforcement learning (RL) to develop an adaptive penalty parameter selection policy for alternating current optimal power flow (ACOPF) problem solved via ADMM with the goal of minimizing the number of iterations until convergence. We train our RL policy using deep Q-learning and show that this policy can result in significantly accelerated convergence (up to a 59% reduction in the number of iterations compared to existing, curvatureinformed penalty parameter selection methods). Furthermore, we show that our RL policy demonstrates promise for generalizability, performing well under unseen loading schemes as well as under unseen losses of lines and generators (up to a 50% reduction in iterations). This work thus provides a proof-of-concept for using RL for parameter selection in ADMM for power systems applications.

alternating current optimal power flow↗

Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers

We report that to dehumidify a humid air stream, existing air conditioning (AC) systems substantially overcool the outdoor humid air below its dew point, thereby significantly reducing energy efficiency. Directly capturing humidity, membrane-based liquid-desiccant dehumidification systems separate sensible and latent cooling (SSLC) loads and thus offer a promising pathway for a high-performance AC solution. Design of an energy-efficient SSLC-AC system, however, rests largely on detailed understating of the dehumidification process. While some studies have identified the dehumidification process mainly depends on membrane characteristics, other studies have argued that the process is limited by desiccant liquid or alternatively air thermo-hydraulic physics for typical humid climate conditions. The present study examines performance and physics of the membrane-based liquid-desiccant dehumidification process over a wide range of climate conditions through a novel 3D, two-phase, multi-species CFD model. Decoupling the thermodynamic and hydraulic effects, the study reveals that the dehumidification rate is a linear function of the water vapor pressure potential ($J=α ΔP$) summarizing the system's thermodynamic state. The slope of the curve (i.e., α) depends on hydraulic transport characteristics of the membrane pores, air stream, and desiccant solution. More importantly, it was found that the air dehumidification process is mainly limited by the air-side transport physics for thin liquid-desiccant films and commonly used porous superhydrophobic membranes. Additionally, results show that, depending on ambient/desiccant conditions and physical dehumidifier characteristics, energy effectiveness and dehumidification rate vary from 13 to 34% and from 0.13 to 1.4 g m -2 s -1 , respectively. Therefore, the present study allows to efficiently design future SSLC-based AC systems exhibiting high performance energy metrics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Steady-state off-design modeling of the supercritical carbon dioxide recompression cycle for concentrating solar power applications with two-tank sensible-heat storage

Concentrating solar power researchers are evaluating the potential of the supercritical carbon dioxide recompression cycle to improve the thermal efficiency and decrease the capital costs of next-generation systems. This analysis investigates the steady-state off-design performance of a recompression cycle integrated with two-tank sensible-heat thermal energy storage as the ambient temperature and heat-transfer fluid (HTF) inlet conditions to the cycle change. This paper presents off-design component models and then cycle convergence and control models to maximize net cycle power output while constraining the high-side pressure and air-cooler fan power to their respective design values and fixing the cycle HTF outlet temperature to its design value. Results show that inventory control and air-cooler fan power are important control parameters that can be optimized to maximize off-design power output as the ambient temperature and HTF mass flow rate diverge from design. The high-side pressure and fan power constraints cause the cycle net power to degrade when the ambient temperature is warmer than the design value, and this study calculates a maximum mass flow rate for hot days above which the cycle cannot achieve the design HTF outlet temperature. Finally, the analysis shows that optimizing compressor shaft speeds can improve cold-day performance by around 1.5 percentage points and part-load performance by up to 2.5 percentage points versus a baseline case with no active compressor control.

14 SOLAR ENERGY↗

Modelling and assessing the near-wake representation and turbulence behaviour of control-oriented wake models

Due to the interaction between the wake of an upstream turbine on a downstream turbine, power losses and increased fatigue loads occur. By yawing the upstream turbine with regard to the wind direction, one can potentially reduce the power losses of the downstream turbine and reduce the fatigue loads. The evolution of the wake depends on the pressure gradient within the near-wake region and the turbulent kinetic energy and must be incorporated in existing wake steering algorithms to provide an accurate estimation of the wake flow. This paper will show a first approach to implement a near-wake model and a turbulence model in the curled wake model within the controls-oriented framework FLORIS. The near-wake model is based on an analytical expression of the velocity profile to model the pressure gradient. Furthermore, two turbulence models are incorporated within the curled wake model based on a Gaussian-distribution and a mixing length formulation. The adapted curled wake model is then assessed with the measurement data acquired in the wind tunnel at ForWind – University of Oldenburg. The evaluation of the models show good agreement for the velocity deficit and representation of the near-wake region. Furthermore, the turbulent kinetic energy behaved as expected in comparison to other work, showing a ring of high turbulent kinetic energy at non-yawed condition which is deflected to a curled shape at large yaw angles with the turbulence model based on a mixing length formulation.

FLORIS↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Analyzing Mechanical integrity of Microwave resonant Cavity flowmeter

The microwave resonant cavity flow sensor has been proposed to address the difficulties of measuring high-temperature molten salt flow in reactor vessels. The flow sensor consists of a metallic cylindrical cavity coupled to a microwave waveguide. The cylindrical cavity has one of the flat surfaces thin enough to undergo microscopic deflection due to dynamic pressure of the exerted by the flowing fluid. Deflection of the membrane causes a shift in the microwave resonant frequency. Fluid velocity can be estimated from the calibration curve. The objective of this report is to investigate mechanical integrity of the flowmeter’s membrane. The membrane is a thin stainless-steel circular plate with a clamped edge, subjected to uniform load. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. If the maximum stress is greater than the yield strength, the plate will undergo plastic deformation, and the sensor will be disabled. A stress greater than the ultimate tensile strength will cause the plate to fracture. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Stresses in both the analytic model and COMSOL numerical model were calculated for stainless steel 316 thin circular plates under room temperature conditions, where the fluid is water. The diameter of the circular plate is approximately one inch, and thickness is 10mil. Fluid flow velocity is in the range from 0.5m/s to 1m/s. The results from the two models are similar. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Elucidating effects of catalyst loadings and porous transport layer morphologies on operation of proton exchange membrane water electrolyzers

Producing green hydrogen efficiently via proton exchange membrane water electrolysis (PEMWE) is the key for achieving decarbonization targets. Iridium catalyst is expensive, and it is important to minimize its use and to optimize interface between Ir and ionomer or water for higher utilization of catalyst in oxygen evolution reaction. In this work, x-ray computed tomography along with electrochemical and modeling techniques are used to characterize the interface for two different porous transport layers (PTLs) and catalyst layers at various loadings. We show that low porosity sintered PTLs exhibit higher interfacial contact with the catalyst and the membrane that results in improved kinetics. Radiography and modeling results indicate that oxygen taking multiple transport pathways through the PTL results in slug flow through the channels that reduces mass transport overpotential. Based on the results, we suggest design guidelines for high efficiency and durable PEMWE and their components.

08 HYDROGEN↗

Eliminating Signal Bias Caused by Vacuum System Backstreaming in the Diagnostic Residual Gas Analyzer of ITER

In fusion neutral gas analysis, such as with the Diagnostic Residual Gas Analyzer (DRGA) for ITER, the primary measurement range of interest comprises the low-amu species (1 to 6), especially deuterium and helium. The challenge in successfully obtaining accurate measurements is two-fold. First, the sensitivity of the method must be sufficient to resolve trace amounts accurately; typically, one percent or less. Second, the gas signal from the fusion processes must be free of bias caused by the latent presence (from system outgassing and/or vacuum backstreaming) of these gases to enable accurate interpretation of the measured signal. This latter criterion can be problematic for the lightest gases since there is a propensity for some fraction of the pumped gas load to undergo a phenomenon known as backstreaming. This behavior is manifested in pumping systems for gas properties related to relative atomic weight (lightest) and size (smallest). Backstreaming results in a significant amount of the pumped gas undertaking a reverse flow and re-entering the measurement region; thus, contaminating the forward, real-time measurement. To fully eliminate this adverse effect, a conductance-limiting device – or orifice – has been installed in the high-vacuum pumping system of the present ITER DRGA prototype. The system was already equipped with a secondary turbomolecular pump (TMP), but with limited effectiveness against backstreaming in the inter-pump volume (IPV). This orifice is placed within the suction inlet coupling of the secondary TMP, which is downstream of the IPV. Its objective is to eliminate the backstreaming phenomenon by increasing the back pressure in the IPV. However, the orifice sizing must take into consideration other factors, such as the diagnostic measurement objectives. For example, in the ITER DRGA, one of the measurement requirements is a dynamic response time of ~1s. Fortunately, an added benefit of the pumping restriction created by the orifice is that the upstream pressure increase is beneficial for the DRGA’s optical gas analysis (OGA) sensors. These sensors are attached to the IPV in the present design. The glow discharges, when used as an OGA light source, will typically have a brighter light emission with increasing plasma cell pressure. In addition to the fusion machine research sector, there are other potential applications of this pumping technique where the monitoring of lighter gas concentrations is essential, such as the photolithography process for the semiconductor fabrication of integrated circuits. This presentation will describe the vacuum system used to demonstrate a process to eliminate backstreaming as well as show test results to verify the accomplishment of this critical objective.

Marcus, Chris↗

A Compact Cryogenic Environment for In Situ Neutron Diffraction Under Mechanical Loading

Understanding the deformation mechanisms of materials at cryogenic temperatures is crucial for cryogenic engineering applications. In situ neutron diffraction is a powerful technique for probing such mechanisms under cryogenic conditions. In this study, we present the development of a compact cryogenic environment (CCE) designed to facil-itate in situ neutron diffraction experiments under mechanical loading at tempera-tures as low as 77 K. The CCE features a polystyrene foam cryogenic chamber, alumi-num blocks serving as neutron-transparent cold sinks, a liquid nitrogen dosing system for cryogen delivery, a nitrogen gas flow control system for thermal management, a process controller for temperature control, and a pair of thermally isolated grip adapt-ers for mechanical testing. The CCE achieves reliable temperature control with mini-mal neutron attenuation. Utilizing this setup, we conducted three in situ neutron dif-fraction tensile tests on a 316L stainless steel at 77 , 173 , and 298 K, respectively. The results highlight the pronounced effects of cryogenic temperatures on the material's deformation mechanisms, underscoring both the significance of cryogenic deformation studies and the effectiveness of the CCE.

Yu, Dunji [ORNL] (ORCID:0000000189467851)↗

An Orthogonal Recursive Bisection (ORB) Based Time Advancement Algorithm for CFD-DEM Solvers

The time integration of the granular phase in coupled computational fluid dynamics (CFD) – discrete element method (DEM) simulations presents a unique computational challenge brought about by the large variations in particle collisional time scales. Particles in the dilute regions of the computational domain can be advanced with large time steps while dense regions require much smaller time increments. However, the time step size in most solvers is globally set as the limit for accuracy and stability imposed by the collisions and is typically orders of magnitude less than that required away from collisions. This work addresses this precise issue and provides a strategy to avoid the use of a global conservative small time step size for the entire set of particles.A novel time stepping algorithm for CFD-DEM solvers using a partitioning approach using orthogonal recursive bisection (ORB) that allows for variable time steps among particles is described and its computational performance is compared against baseline explicit methods, typically used in several CFD-DEM solvers. ORB has advantages of being relatively quick and easy to update incrementally and has the required heuristic behavior (i.e., it will split the region in half with a cluster on each side) when groups of particles are well separated (clustered). The algorithm presented in this work uses a local time stepping approach to resolve collisional time scales for subsets of particles that are present at the leaves of the ORB, thereby resulting in substantial reduction of computational cost. The parallel implementation of this method where a ``knapsack” algorithm is used in tandem with ORB for effective load-balancing is also presented, where a best possible partitioning is obtained based on number of particles and local time-stepping costs. The algorithm is tested against benchmark problems with varying particle distributions that include fluidized bed and riser flow scenarios. Preliminary results indicate that the approach is 2-3X faster than traditional explicit methods for problems that involve both dense and dilute regions, while maintaining the same level of accuracy.

adaptive timestepping↗