Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

CHARACTERIZING THE OPTICAL VARIABILITY OF BRIGHT BLAZARS: VARIABILITY-BASED SELECTION OF FERMI ACTIVE GALACTIC NUCLEI

We investigate the use of optical photometric variability to select and identify blazars in large-scale time-domain surveys, in part to aid in the identification of blazar counterparts to the {approx}30% of {gamma}-ray sources in the Fermi 2FGL catalog still lacking reliable associations. Using data from the optical LINEAR asteroid survey, we characterize the optical variability of blazars by fitting a damped random walk model to individual light curves with two main model parameters, the characteristic timescales of variability {tau}, and driving amplitudes on short timescales {sigma}-circumflex. Imposing cuts on minimum {tau} and {sigma}-circumflex allows for blazar selection with high efficiency E and completeness C. To test the efficacy of this approach, we apply this method to optically variable LINEAR objects that fall within the several-arcminute error ellipses of {gamma}-ray sources in the Fermi 2FGL catalog. Despite the extreme stellar contamination at the shallow depth of the LINEAR survey, we are able to recover previously associated optical counterparts to Fermi active galactic nuclei with E {>=} 88% and C = 88% in Fermi 95% confidence error ellipses having semimajor axis r < 8'. We find that the suggested radio counterpart to Fermi source 2FGL J1649.6+5238 has optical variability consistent with other {gamma}-ray blazars and is likely to be the {gamma}-ray source. Our results suggest that the variability of the non-thermal jet emission in blazars is stochastic in nature, with unique variability properties due to the effects of relativistic beaming. After correcting for beaming, we estimate that the characteristic timescale of blazar variability is {approx}3 years in the rest frame of the jet, in contrast with the {approx}320 day disk flux timescale observed in quasars. The variability-based selection method presented will be useful for blazar identification in time-domain optical surveys and is also a probe of jet physics.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-Time Target Position Estimation Using Stereoscopic Kilovoltage/Megavoltage Imaging and External Respiratory Monitoring for Dynamic Multileaf Collimator Tracking

Purpose: To develop a real-time target position estimation method using stereoscopic kilovoltage (kV)/megavoltage (MV) imaging and external respiratory monitoring, and to investigate the performance of a dynamic multileaf collimator tracking system using this method. Methods and Materials: The real-time three-dimensional internal target position estimation was established by creating a time-varying correlation model that connected the external respiratory signals with the internal target motion measured intermittently using kV/MV imaging. The method was integrated into a dynamic multileaf collimator tracking system. Tracking experiments were performed for 10 thoracic/abdominal traces. A three-dimensional motion platform carrying a gold marker and a separate one-dimensional motion platform were used to reproduce the target and external respiratory motion, respectively. The target positions were detected by kV (1 Hz) and MV (5.2 Hz) imaging, and external respiratory motion was captured by an optical system (30 Hz). The beam-target alignment error was quantified as the positional difference between the target and circular beam center on the MV images acquired during tracking. The correlation model error was quantified by comparing a model estimate and measured target positions. Results: The root-mean-square errors in the beam-target alignment that had ranged from 3.1 to 7.6 mm without tracking were reduced to <1.5 mm with tracking, except during the model building period (6 s). The root-mean-square error in the correlation model was submillimeters in all directions. Conclusion: A novel real-time target position estimation method was developed and integrated into a dynamic multileaf collimator tracking system and demonstrated an average submillimeter geometric accuracy after initializing the internal/external correlation model. The method used hardware tools available on linear accelerators and therefore shows promise for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation and Simulation of Slow Crack Growth Parameters from Constant Stress Rate Data

Closed form, approximate functions for estimating the variances and degrees-of-freedom associated with the slow crack growth parameters n, D, B, and A(sup *) as measured using constant stress rate ('dynamic fatigue') testing were derived by using propagation of errors. Estimates made with the resulting functions and slow crack growth data for a sapphire window were compared to the results of Monte Carlo simulations. The functions for estimation of the variances of the parameters were derived both with and without logarithmic transformation of the initial slow crack growth equations. The transformation was performed to make the functions both more linear and more normal. Comparison of the Monte Carlo results and the closed form expressions derived with propagation of errors indicated that linearization is not required for good estimates of the variances of parameters n and D by the propagation of errors method. However, good estimates variances of the parameters B and A(sup *) could only be made when the starting slow crack growth equation was transformed and the coefficients of variation of the input parameters were not too large. This was partially a result of the skewered distributions of B and A(sup *). Parametric variation of the input parameters was used to determine an acceptable range for using closed form approximate equations derived from propagation of errors.

Salem, Jonathan A.↗

OPERATIONAL TOPOLOGY ESTIMATION OF THREE PHASE UNBALANCED POWER DISTRIBUTION SYSTEMS WITH OUTAGES

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allows transition from one radial topology to another. Tie-switches ensure reliability and provide restoration paths when faults (outages) occur. The estimation of the system's current operational topology is a precursor to implementing any optimal control actions (during normal operation) or restorative actions (during outage condition). The existing literature in topology detection suffers with several limitations including: (1) computationally intensive nonlinear formulations that are not scalable for large distribution systems, (2) methods requiring exhaustive search for the correct topology by enumerating the complete topological search space, and (3) approaches requiring large volumes of time-series measurements and are not applicable for estimating continuously changing operational topology. Furthermore, the existing literature on distribution grid topology estimation cannot be extended to estimate the operational topology during outage conditions. For operational topology estimation during outages, our objective is to estimate both energized radial feeder and the outaged sections. Starting with a radial topology, these methods identify outaged feeder sections and hence, are inapplicable when the current radial operational topology is not known. In this work, we present a mathematical programming approach to estimate the operational topology of a three-phase unbalanced power distribution system under both outage and normal operating conditions. The aforementioned limitations of existing literature were countered by modeling the problem as a mixed-integer linear programming (MILP) problem which minimizes the errors in available measurements while satisfying the power flow and structural constraints of the system. Specically, a minimum weighted least absolute value estimator is proposed that uses the instantaneous line flow measurements, historical/ forecasted load data, and ping measurements from a limited set of smart meters and solves an MILP to identify the operational topology based on a linearized three-phase unbalanced power flow model. The proposed approach is tested on IEEE 123-bus feeder and 1069 bus multi-feeder test system and the numerical results prove the applicability of the proposed method to large three phase unbalanced grids with high errors in measurements. It is observed that the approach performs well even at high percentages of measurement errors.

GANDLURU NAGA, ANANDINI↗

Robustness tests utilizing the structure of modelling error

The present investigation is essentially concerned with the extension of results presented by Lehtomaki et al. (1981) on the robustness of multivariable linear time invariant feedback control systems. The work reported by Lehtomaki et al. is based on a multivariable version of Nyquist's theorem from which several robustness theorems were derived. In connection with the current investigation a slightly more general approach based on Nyquist's theorem is given in a fundamental robustness theorem from which various robustness tests may be obtained. A fundamental characterization of robustness is considered, and important tools from matrix theory are introduced. Attention is given to robustness tests and unstructured model error, and a robustness analysis for linear systems with structured model error.

Lehtomaki, N. A.↗

Features of temperature control of fuel element cladding for pressurized water nuclear reactor “WWER-1000” while simulating reactor accidents

During the experiments simulating NPR (nuclear power reactor) accidents with a coolant loss fuel elements behavior in a steam-hydrogen medium was studied at the temperature changed with the rate from 1 to 100K/s within the range of 300÷1500 °C. Indications of the thermocouples fixed on the cladding notably differ from real values of the cladding temperatures in the area of measuring junction due to thermal resistance influence of the transition zones “cladding-junction” and “junction-coolant”. The estimating method of a measurement error was considered which can provide adequate accounting of the influence factors. The method is based on thermal probing of a thermocouple by electric current flashing through thermoelements under the coolant presence or absence, a response time registration and processing, calculation of thermal inertia value for a thermocouple junction. A formula was derived for calculation of methodical error under stationary mode and within the stage of linear increase in temperature, which will determine the conditions for the cladding depressurization. Some variants of the formula application were considered, and the values of methodical errors were established which reached ∼5% of maximum value by the final moment of the stage of linear increase in the temperature.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Non-linear duct acoustics and its application to fan noise

Quite often the scalar Helmholtz equation is assumed to be the fundamental equation of duct acoustics and various relations are derived from it. An investigation is, therefore, conducted regarding the underlying assumptions leading to the Helmholtz equation. It is found that serious errors, even well below 186 dB, are possible if the assumption of linearity were to be made. In duct acoustics these errors are highest near the cutoff points and in the case of ducts with transonic flow. It is pointed out that serious errors could arise if a nonlinear problem is analyzed by linear methods. At times, an entire phenomenon remains unpredictable by linear methods. Attention is given to the characteristics of nonlinear systems, the phenomenon of multiple pure tones in the case of noise from the aircraft engine fans, the limitations of the conventional acoustics equation, duct shape and nonlinearity, and the numerical simulation of a fan with 8 blades.

Vaidya, P. G.↗

A Bayesian approach to real-time 3D tumor localization via monoscopic x-ray imaging during treatment delivery

Purpose: Monoscopic x-ray imaging with on-board kV devices is an attractive approach for real-time image guidance in modern radiation therapy such as VMAT or IMRT, but it falls short in providing reliable information along the direction of imaging x-ray. By effectively taking consideration of projection data at prior times and/or angles through a Bayesian formalism, the authors develop an algorithm for real-time and full 3D tumor localization with a single x-ray imager during treatment delivery. Methods: First, a prior probability density function is constructed using the 2D tumor locations on the projection images acquired during patient setup. Whenever an x-ray image is acquired during the treatment delivery, the corresponding 2D tumor location on the imager is used to update the likelihood function. The unresolved third dimension is obtained by maximizing the posterior probability distribution. The algorithm can also be used in a retrospective fashion when all the projection images during the treatment delivery are used for 3D localization purposes. The algorithm does not involve complex optimization of any model parameter and therefore can be used in a ''plug-and-play'' fashion. The authors validated the algorithm using (1) simulated 3D linear and elliptic motion and (2) 3D tumor motion trajectories of a lung and a pancreas patient reproduced by a physical phantom. Continuous kV images were acquired over a full gantry rotation with the Varian TrueBeam on-board imaging system. Three scenarios were considered: fluoroscopic setup, cone beam CT setup, and retrospective analysis. Results: For the simulation study, the RMS 3D localization error is 1.2 and 2.4 mm for the linear and elliptic motions, respectively. For the phantom experiments, the 3D localization error is < 1 mm on average and < 1.5 mm at 95th percentile in the lung and pancreas cases for all three scenarios. The difference in 3D localization error for different scenarios is small and is not statistically significant. Conclusions: The proposed algorithm eliminates the need for any population based model parameters in monoscopic image guided radiotherapy and allows accurate and real-time 3D tumor localization on current standard LINACs with a single x-ray imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Efficient Silent Data Corruption Detection Method with Error-Feedback Control and Even Sampling for HPC Applications

The silent data corruption (SDC) problem is attracting more and more attentions because it is expected to have a great impact on exascale HPC applications. SDC faults are hazardous in that they pass unnoticed by hardware and can lead to wrong computation results. In this work, we formulate SDC detection as a runtime one-step-ahead prediction method, leveraging multiple linear prediction methods in order to improve the detection results. The contributions are twofold: (1) we propose an error feedback control model that can reduce the prediction errors for different linear prediction methods, and (2) we propose a spatial-data-based even-sampling method to minimize the detection overheads (including memory and computation cost). We implement our algorithms in the fault tolerance interface, a fault tolerance library with multiple checkpoint levels, such that users can conveniently protect their HPC applications against both SDC errors and fail-stop errors. We evaluate our approach by using large-scale traces from well-known, large-scale HPC applications, as well as by running those HPC applications on a real cluster environment. Experiments show that our error feedback control model can improve detection sensitivity by 34-189% for bit-flip memory errors injected with the bit positions in the range [20,30], without any degradation on detection accuracy. Furthermore, memory size can be reduced by 33% with our spatial-data even-sampling method, with only a slight and graceful degradation in the detection sensitivity.

Di, Sheng↗

Absolute flux density calibrations: Receiver saturation effects

The effect of receiver saturation was examined for a total power radiometer which uses an ambient load for calibration. Extension to other calibration schemes is indicated. The analysis shows that a monotonic receiver saturation characteristic could cause either positive or negative measurement errors, with polarity depending upon operating conditions. A realistic model of the receiver was made by using a linear-cubic voltage transfer characteristic. The evaluation of measurement error for this model provided a means for correcting radio source measurements.

Freiley, A. J.↗

On the Synergy Between Numerics and Subgrid Scale Modeling in LES of Stratified Flows: Grid Convergence of a Stratocumulus-Topped Boundary Layer

The effectiveness of a linear upwinding scalar advection scheme to suppress numerical dispersion errors near sharp inversions in large-eddy simulations of a nocturnal stratocumulus-topped boundary layer is assessed. Linear upwinding is a trade-off between non-dissipative and non-linear positive definite advection schemes. It is shown that linear upwinding does not negatively impact the model's grid convergence properties and a sharp inversion free of numerical artifacts is maintained. Even though mean profiles and turbulence fluxes show good grid convergence characteristics the liquid water amount varies significantly with grid resolution. The entrainment rate is identical for all resolutions and independent of the liquid water amount. For the present stratocumulus case, the impact of cloud-top radiative cooling is negligible and turbulence is largely driven by convection emanating from the surface.

Matheou, Georgios↗

Bi-Objective Optimal Control Modification Adaptive Control for Systems with Input Uncertainty

This paper presents a new model-reference adaptive control method based on a bi-objective optimal control formulation for systems with input uncertainty. A parallel predictor model is constructed to relate the predictor error to the estimation error of the control effectiveness matrix. In this work, we develop an optimal control modification adaptive control approach that seeks to minimize a bi-objective linear quadratic cost function of both the tracking error norm and predictor error norm simultaneously. The resulting adaptive laws for the parametric uncertainty and control effectiveness uncertainty are dependent on both the tracking error and predictor error, while the adaptive laws for the feedback gain and command feedforward gain are only dependent on the tracking error. The optimal control modification term provides robustness to the adaptive laws naturally from the optimal control framework. Simulations demonstrate the effectiveness of the proposed adaptive control approach.

Nguyen, Nhan T.↗

MO-FG-202-05: Identifying Treatment Planning System Errors in IROC-H Phantom Irradiations

Purpose: Treatment Planning System (TPS) errors can affect large numbers of cancer patients receiving radiation therapy. Using an independent recalculation system, the Imaging and Radiation Oncology Core-Houston (IROC-H) can identify institutions that have not sufficiently modelled their linear accelerators in their TPS model. Methods: Linear accelerator point measurement data from IROC-H’s site visits was aggregated and analyzed from over 30 linear accelerator models. Dosimetrically similar models were combined to create “classes”. The class data was used to construct customized beam models in an independent treatment dose verification system (TVS). Approximately 200 head and neck phantom plans from 2012 to 2015 were recalculated using this TVS. Comparison of plan accuracy was evaluated by comparing the measured dose to the institution’s TPS dose as well as the TVS dose. In cases where the TVS was more accurate than the institution by an average of >2%, the institution was identified as having a non-negligible TPS error. Results: Of the ∼200 recalculated plans, the average improvement using the TVS was ∼0.1%; i.e. the recalculation, on average, slightly outperformed the institution’s TPS. Of all the recalculated phantoms, 20% were identified as having a non-negligible TPS error. Fourteen plans failed current IROC-H criteria; the average TVS improvement of the failing plans was ∼3% and 57% were found to have non-negligible TPS errors. Conclusion: IROC-H has developed an independent recalculation system to identify institutions that have considerable TPS errors. A large number of institutions were found to have non-negligible TPS errors. Even institutions that passed IROC-H criteria could be identified as having a TPS error. Resolution of such errors would improve dose delivery for a large number of IROC-H phantoms and ultimately, patients.

60 APPLIED LIFE SCIENCES↗

A generalized method for the identification of aircraft stability and control derivatives from flight test data.

This paper discusses the application of a generalized identification method for flight test data analysis. The method is based on the maximum likelihood (ML) criterion and includes output error and equation error methods as special cases. Both the linear and nonlinear models with and without process noise are considered. The flight test data from lateral maneuvers of HL-10 and M2/F3 lifting bodies are processed to determine the lateral stability and control derivatives, instrumentation accuracies and biases. A comparison is made between the results of the output error method and the generalized ML method for M2/F3 data containing gusts. It is shown that better fits to time histories are obtained by using the generalized ML method.

Mehra, R. K.↗

Maximum likelihood identification of aircraft stability and control derivatives

Application of a generalized identification method to flight test data analysis. The method is based on the maximum likelihood (ML) criterion and includes output error and equation error methods as special cases. Both the linear and nonlinear models with and without process noise are considered. The flight test data from lateral maneuvers of HL-10 and M2/F3 lifting bodies are processed to determine the lateral stability and control derivatives, instrumentation accuracies, and biases. A comparison is made between the results of the output error method and the ML method for M2/F3 data containing gusts. It is shown that better fits to time histories are obtained by using the ML method. The nonlinear model considered corresponds to the longitudinal equations of the X-22 VTOL aircraft. The data are obtained from a computer simulation and contain both process and measurement noise. The applicability of the ML method to nonlinear models with both process and measurement noise is demonstrated.

Mehra, R. K.↗

A Hierarchical OPF Algorithm with Improved Gradient Evaluation in Three-Phase Networks

Linear approximation commonly used in solving alternating-current optimal power flow (AC-OPF) simplifies the system models but incurs accumulated voltage errors in large power networks. Such errors will make the primal-dual type gradient algorithms converge to solutions with voltage violation. In this paper, we improve a recent hierarchical OPF algorithm that rested on primal-dual gradients evaluated with a linearized distribution power flow model. Specifically, we propose a more accurate gradient evaluation method based on an unbalanced three-phase nonlinear distribution power flow model to mitigate the errors arising from linearization. The resultant gradients feature a blocked structure that enables our development of an improved hierarchical primal-dual algorithm to solve the OPF problem. Numerical results on the IEEE 123-bus test feeder and a 4,518-node test feeder show that the proposed method can enhance voltage safety at comparable computational efficiency with the linearized algorithm.

approximation algorithms↗

Evaluation of image guided motion management methods in lung cancer radiotherapy

Purpose: To evaluate the accuracy and reliability of three target localization methods for image guided motion management in lung cancer radiotherapy. Methods: Three online image localization methods, including (1) 2D method based on 2D cone beam (CB) projection images, (2) 3D method using 3D cone beam CT (CBCT) imaging, and (3) 4D method using 4D CBCT imaging, have been evaluated using a moving phantom controlled by (a) 1D theoretical breathing motion curves and (b) 3D target motion patterns obtained from daily treatment of 3 lung cancer patients. While all methods are able to provide target mean position (MP), the 2D and 4D methods can also provide target motion standard deviation (SD) and excursion (EX). For each method, the detected MP/SD/EX values are compared to the analytically calculated actual values to calculate the errors. The MP errors are compared among three methods and the SD/EX errors are compared between the 2D and 4D methods. In the theoretical motion study (a), the dependency of MP/SD/EX error on EX is investigated with EX varying from 2.0 cm to 3.0 cm with an increment step of 0.2 cm. In the patient motion study (b), the dependency of MP error on target sizes (2.0 cm and 3.0 cm), motion patterns (four motions per patient) and EX variations is investigated using multivariant linear regression analysis. Results: In the theoretical motion study (a), the MP detection errors are −0.2 ± 0.2, −1.5 ± 1.1, and −0.2 ± 0.2 mm for 2D, 3D, and 4D methods, respectively. Both the 2D and 4D methods could accurately detect motion pattern EX (error < 1.2 mm) and SD (error < 1.0 mm). In the patient motion study (b), MP detection error vector (mm) with the 2D method (0.7 ± 0.4) is found to be significantly less than with the 3D method (1.7 ± 0.8,p < 0.001) and the 4D method (1.4 ± 1.0, p < 0.001) using paired t-test. However, no significant difference is found between the 4D method and the 3D method. Based on multivariant linear regression analysis, the variances of MP error in SI direction explained by target sizes, motion patterns, and EX variations are 9% with the 2D method, 74.4% with the 3D method, and 27% with the 4D method. The EX/SD detection errors are both < 1.0 mm for the 2D method and < 2.0 mm for the 4D method. Conclusions: The 2D method provides the most accurate MP detection regardless of the motion pattern variations, while its performance is limited by the accuracy of target identification in the projection images. The 3D method causes the largest error in MP determination, and its accuracy significantly depends on target sizes, motion patterns, and EX variations. The 4D method provides moderate MP detection results, while its accuracy relies on a regular motion pattern. In addition, the 2D and 4D methods both provide accurate measurement of the motion SD/EX, providing extra information for motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radar sensitivity and antenna scan pattern study for a satellite-based Radar Wind Sounder (RAWS)

Modeling global atmospheric circulations and forecasting the weather would improve greatly if worldwide information on winds aloft were available. Recognition of this led to the inclusion of the LAser Wind Sounder (LAWS) system to measure Doppler shifts from aerosols in the planned for Earth Observation System (EOS). However, gaps will exist in LAWS coverage where heavy clouds are present. The RAdar Wind Sensor (RAWS) is an instrument that could fill these gaps by measuring Doppler shifts from clouds and rain. Previous studies conducted at the University of Kansas show RAWS as a feasible instrument. This thesis pertains to the signal-to-noise ratio (SNR) sensitivity, transmit waveform, and limitations to the antenna scan pattern of the RAWS system. A dop-size distribution model is selected and applied to the radar range equation for the sensitivity analysis. Six frequencies are used in computing the SNR for several cloud types to determine the optimal transmit frequency. the results show the use of two frequencies, one higher (94 GHz) to obtain sensitivity for thinner cloud, and a lower frequency (24 GHz) to obtain sensitivity for thinner cloud, and a lower frequency (24 GHz) for better penetration in rain, provide ample SNR. The waveform design supports covariance estimation processing. This estimator eliminates the Doppler ambiguities compounded by the selection of such high transmit frequencies, while providing an estimate of the mean frequency. the unambiguous range and velocity computation shows them to be within acceptable limits. The design goal for the RAWS system is to limit the wind-speed error to less than 1 ms(exp -1). Due to linear dependence between vectors for a three-vector scan pattern, a reasonable wind-speed error is unattainable. Only the two-vector scan pattern falls within the wind-error limits for azimuth angles between 16 deg to 70 deg. However, this scan only allows two components of the wind to be determined. As a result, a technique is then shown, based on the Z-R-V relationships, that permit the vertical component (i.e., rain) to be computed. Thus the horizontal wind components may be obtained form the covariance estimator and the vertical component from the reflectivity factor. Finally, a new candidate system is introduced which summarizes the parameters taken from previous RAWS studies, or those modified in this thesis.

Stuart, Michael A.↗