Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Indoor and Outdoor Test Results for 'DUSST', a Low-Cost, Low-Maintenance PV Soiling Sensor

Soiling can cause significant losses to photovoltaic systems, and therefore it is often measured for the purposes of predicting long-term energy forecasts or for monitoring real time performance and triggering maintenance events as needed. Currently, the most common soiling monitoring technologies are soiling stations that use the electrical outputs of a regularly cleaned PV device and of a naturally soiled PV device to quantify soiling. As part of a new class of low-cost and low-maintenance soiling stations NREL has previously presented 'DUSST'. DUSST projects a collimated monochromatic light source through a glass surface (exposed similarly to the PV modules that need to be monitored) and on to a light detector to measure the intensity of the transmitted light. As the glass surface naturally soils, the losses are quantified by comparing this soiled reading with a calibrated reading under baseline clean condition. This work presents the ongoing improvement of DUSST and the ongoing indoor and outdoor validation of this new soiling sensor.

14 SOLAR ENERGY↗

From Deposition to Encapsulation: Roll-to-roll manufacturing of organic light emitting devices for lighting (Final Report)

Organic light emitting devices (OLEDs) are promising solid state light sources due to their high efficiency, high color quality and flexible form factors. The key to enable low cost OLED lighting, is to rapidly fabricate thin film organic layers on a continuous flexible roll, called R2R processing. This project aims to investigate the feasibility of mass production of OLED lighting using the R2R process, from deposition to encapsulation. A high efficiency white OLED is fabricated on 10 cm-wide substrate rolls in a pilot R2R tool comprising of two different organic deposition: vacuum thermal evaporation (VTE) and organic vapor phase deposition (OVPD). A high quality encapsulation process to package OLEDs is demonstrated using an atomic layer deposition tool integrated to the R2R system without air exposure. The method to achieve ultrahigh deposition rates required by R2R processing is demonstrated by OVPD. Uniform organic semiconductor thin films grown by OVPD at rates as high as 50 Å/s are achieved. A comprehensive numerical model that is capable of simulating complex, multilayer WOLED structures is developed to provide an alternative to experimental iterations of OLED design and tests. A cost estimate on the R2R production of WOLEDs for lighting is developed. Assuming a WOLED luminance of 10 klm/m 2 , the cost of a WOLED light engine is anticipated to be $\$ 12.5$ /klm. With incremental reduction in material and driver costs and improved luminance, the cost of WOLED lighting can be reduced to $\$ 6.3$ /klm in the near term. These findings suggest OLED lighting can be volume manufactured by R2R vapor deposition methods with much reduced costs compared to current batch processing methods, potentially positioning WOLEDs for use in numerous premium lighting applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proximity sensor technology for manipulator end effectors

Optical proximity sensing devices suitable for hand mounting on a manipulator are described, which use near IR LED light sources operating at 0.94 micron and silicon detectors, with appropriate signal processing so that the data are unaffected by ambient light. Laboratory tests with simple proximity sensors are described. Extension of the same techniques to yield multipoint or digital sensors is also discussed. A cooperative proximity sensor concept is described, which employs a composite mirror attached to the work piece to generate an unambiguous set of position and orientation signals. A very rudimentary experiment in local control of a manipulator with a pair of hand mounted proximity sensors is also described.

Johnston, A. R.↗

Atomic Resonance Radiation Energetics Investigation as a Diagnostic Method for Non-Equilibrium Hypervelocity Flows

Absorption measurements with a tunable vacuum ultraviolet light source have been proposed as a concentration diagnostic for atomic oxygen, and the viability of this technique is assessed in light of recent measurements. The instrumentation, as well as initial calibration measurements, have been reported previously. We report here additional calibration measurements performed to study the resonance broadening line shape for atomic oxygen. The application of this diagnostic is evaluated by considering the range of suitable test conditions and requirements, and by identifying issues that remain to be addressed.

Meyer, Scott A.↗

Intercalibration of airglow observatories with the Atmosphere Explorer satellite

The visible airglow photometer on the Atmosphere Explorer C satellite has been used to compare the calibrations of a number of ground-based airglow observatories. Discrepancies between different ground stations as large as a factor of six have been revealed. Efforts to account for these discrepancies have resulted in the discovery of differences as large as a factor of two in the standard light sources in use at different observatories. The participation of additional observatories in the intercomparison of standard sources is solicited. The project has also led to the discovery of a source of error that can amount to another factor of two in the procedure used to calibrate many airglow instruments. In the course of the project, detailed maps based on satellite data have been made of the galactic and zodiacal-light background at a number of wavelengths, and a substantial source of contaminating emission has been discovered in the satellite data. The contamination appears to result from interaction of the spacecraft and the atmosphere at altitudes below 170 km.

Torr, M. R.↗

Mutual Diffusion Coefficients and Refractive Index Increments of K 2 SO 4 (aq) at 298.15 K from Rayleigh Interferometry

Here, isothermal mutual diffusion coefficients (interdiffusion coefficients) were measured for K 2 SO 4 (aq) at 298.15 ± 0.005 K, at numerous concentrations ranging from dilute solutions to near saturation (0.59648 mol∙dm -3 ; 0.61349 mol∙kg -1 ) under free diffusion boundary conditions, using high precision Rayleigh interferometry. Under the experimental conditions these diffusion coefficients are on the volume-fixed reference frame D v . Two series of experiments were performed, the first using the traditional experimental approach with a mercury lamp source and with the interference patterns being recorded on glass photographic plates, and the second with a He-Ne laser light source and computerized data acquisition using a photodiode array. The results from both series of experiments are in excellent agreement, and generally yield diffusion coefficients precise to at least 0.002 x 10 -9 m 2 ∙s 1 (0.15% to 0.19%) and in most cases to 0.001 x 10 -9 m 2 ∙s -1 (0.07% to 0.1%). These experiments also yield accurate values of the refractive index differences for the solution pairs used in the diffusion experiments. The new diffusion coefficients are compared to two sets of published values of diffusion coefficients for K 2 SO 4 (aq) which are somewhat discrepant from each other. This study extends and complements our earlier work on the diffusion coefficients of the most common brine salts: NaCl(aq), KCl(aq), MgCl 2 (aq), CaCl 2 (aq), Na 2 SO 4 (aq), ] MgSO 4 (aq), NaHCO 3 (aq), and KHCO 3 (aq) at 298.15 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temporal laser pulse manipulation using multiple optical ring-cavities

An optical pulse stretcher and a mathematical algorithm for the detailed calculation of its design and performance is disclosed. The optical pulse stretcher has a plurality of optical cavities, having multiple optical reflectors such that an optical path length in each of the optical cavities is different. The optical pulse stretcher also has a plurality of beam splitters, each of which intercepts a portion of an input optical beam and diverts the portion into one of the plurality of optical cavities. The input optical beam is stretched and a power of an output beam is reduced after passing through the optical pulse stretcher and the placement of the plurality of optical cavities and beam splitters is optimized through a model that takes into account optical beam divergence and alignment in the pluralities of the optical cavities. The optical pulse stretcher system can also function as a high-repetition-rate (MHz) laser pulse generator, making it suitable for use as a stroboscopic light source for high speed ballistic projectile imaging studies, or it can be used for high speed flow diagnostics using a laser light sheet with digital particle imaging velocimetry. The optical pulse stretcher system can also be implemented using fiber optic components to realize a rugged and compact optical system that is alignment free and easy to use.

Nguyen, Quang-Viet↗

Vacuum-Compatible Wideband White Light and Laser Combiner Source System

For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

Azizi, Alineza↗

Long Island Steatite Sourcing from Rhode Island Quarries During the Late Holocene Era

This study aimed to investigate the possible sourcing of Long Island steatite artifacts from quarries in Rhode Island. Seven steatite samples from archeological sites on Long Island including Nassau County, Suffolk County (North Fork and South Fork) and Shelter Island were compared to two Rhode Island quarry sample putative sources using X-ray fluorescence (XRF) microscopy at the Submicron Resolution X-ray spectroscopy (SRX) beamline of the National Synchrotron Light Source II at Brookhaven National Laboratory. The site-derived steatite samples displayed numerous similarities in elemental composition compared to the two Rhode Island quarries, Oaklawn and Ochee Springs. This study provides new evidence to support the possible sourcing of Long Island steatite from Rhode Island during the late Holocene era.

54 ENVIRONMENTAL SCIENCES↗

Long Island Steatite Sourcing from Rhode Island Quarries During the Late Holocene Era

This study aimed to investigate the possible sourcing of Long Island steatite artifacts from quarries in Rhode Island. Seven steatite samples from archeological sites on Long Island including Nassau County, Suffolk County (North Fork and South Fork) and Shelter Island were compared to two Rhode Island quarry sample putative sources using X-ray fluorescence (XRF) microscopy at the Submicron Resolution X-ray spectroscopy (SRX) beamline of the National Synchrotron Light Source II at Brookhaven National Laboratory. The site-derived steatite samples displayed numerous similarities in elemental composition compared to the two Rhode Island quarries, Oaklawn and Ochee Springs. This study provides new evidence to support the possible sourcing of Long Island steatite from Rhode Island during the late Holocene era.

54 ENVIRONMENTAL SCIENCES↗

System measures response time of photomultiplier tubes

Calibration system enables precise determination of rise time of photosensitive detectors. To perform a calibration, the time-voltage curve of the excitation voltage for a light source is compared with the time-voltage curve of the voltage output from a photosensitive detector which is responding to the light.

Lauver, M. R.↗

Lineaments that are artifacts of lighting, part G

Apollo 15 orbital photographs, particularly those taken at low sun elevation angles, are examined revealing grid patterns of lineaments. Preliminary results of experiments demonstrate that spurious lineaments and grid patterns can be produced and that the directions are dependent in part upon the position of the light source. The experiments were designed to duplicate the effect of bright sunlight reflecting from a hummocky surface with little or no diffuse light in the shadowed areas.

Howard, K. A.↗

Resonator-based ion-selective sensor

The present disclosure relates to systems and methods suitable to measure trace amounts of specific ions in fluid samples. An example system includes a resonator having an input coupler and an output coupler. The example system also includes an ion-selective membrane (ISM) optically coupled to at least a portion of the resonator. The system additionally includes a light source configured to illuminate the resonator by way of the input coupler. Furthermore, the system includes a detector configured to receive output light by way of the output coupler and provide information indicative a concentration of a specific ion proximate to tire ISM.

Zhang, Xufeng↗

A transportable hemispherical illumination system for making reflectance factor measurements

An artificial source of stable, hemispherical illumination has been developed to facilitate the collection of reflectance factor measurements of targets of interest in a laboratory environment. The light source consists of a 76 cm (30 in.) aluminum hemisphere which has been coated internally with barium sulfate paint. Illumination is provided by two banks of lamps, each consisting of eight 62-W quartz halogen bulbs which have tungsten filaments. An internal baffle precludes the viewing of any direct beam of light. A simple metal structure has been developed to hold the hemisphere and all peripheral equipment, such as spectrometers, radiometers, and cameras, in place during data collection. The entire setup can be easily disassembled and packed in airline approved shipping cases to facilitate transportation to remote laboratory facilities. This illumination system has been used during the past three years to collect spectral reflectance factor data of tree branch samples and seedlings in support of an on-going study to investigate the effect of acidic deposition on forest vegetation.

Williams, Darrel L.↗

Quantum defects in carbon nanotubes as single-photon sources

Single-photon emitters are essential components of emerging quantum technologies, including secure communication and quantum computing. Single-walled carbon nanotubes (SWCNTs) have emerged as a promising platform for quantum light sources due to their quasi-one-dimensional excitonic host structure and compatibility with telecom photonic systems. Recent advances in deterministic defect engineering—most notably the development of organic color centers (OCCs)—have enabled stable, chemically controllable, and spectrally tunable single-photon emission. OCC-based emitters have demonstrated single-photon purity exceeding 99% and, more recently, room-temperature photon indistinguishability, placing them among the few solid-state systems with quantum-grade performance under ambient conditions. This review surveys progress in the field from three complementary perspectives: chemical synthesis and quantum defect engineering, computational studies of structure-property relationships and excitonic behavior, and experimental investigations of quantum optical properties. We also discuss alternative approaches, including air-suspended SWCNTs and hybrid van der Waals heterostructures, highlighting opportunities and open challenges for scalable integration into quantum photonic platforms.

36 MATERIALS SCIENCE↗

Quantum Fluctuations and Lineshape Anomaly in a High‐ β Silver‐Coated InP‐Based Metallic Nanolaser

Abstract Metallic nanocavity lasers provide important technological advancement toward even smaller integrable light sources. They give access to widely unexplored lasing physics in which the distinction between different operational regimes, like those of thermal or coherent light emission, becomes increasingly challenging upon approaching a device with a near‐perfect spontaneous‐emission coupling factor . In fact, quantum‐optical studies have to be employed to reveal a transition to coherent emission in the intensity fluctuation behavior of nanolasers when the input–output characteristic appears thresholdless for nanolasers. Here, a new indicator for lasing operation in high‐ lasers is identified by showing that stimulated emission can give rise to a lineshape anomaly manifested as a transition from a Lorentzian to a Gaussian component in the emission linewidth that dominates the spectrum above the lasing threshold.

Koulas‐Simos, Aris↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Gas Bremsstrahlung sources at the Electron-Ion Collider

This report estimates the potential impact of Gas Bremsstrahlung, generated as the electron beam traverses the straight sections of the storage ring and impinges onto selected locations of the Electron-Ion Collider. The source terms were calculated for routine operation scenarios at three different energies: 5, 10 and 18 GeV, using the FLUKA Monte Carlo particle transport and interaction code. The source term’s power distributions were validated and compared with the Gas Bremsstrahlung produced in the long straight sections of the National Synchrotron Light Source II storage ring.

43 PARTICLE ACCELERATORS↗