Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Radioactive Ion Beam Production Capabilities At The Holifield Radioactive Ion Beam Facility

The Holifield Radioactive Ion Beam Facility (HRIBF) is a national user facility for research with radioactive ion beams (RIBs) that has been in routine operation since 1996. It is located at Oak Ridge National Laboratory (ORNL) and operated by the ORNL Physics Division. The principal mission of the HRIBF is the production of high quality beams of shortlived radioactive isotopes to support research in nuclear structure physics and nuclear astrophysics. HRIBF is currently unique worldwide in its ability to provide neutron-rich fission fragment beams post-accelerated to energies above the Coulomb barrier for nuclear reactions. HRIBF produces RIBs by the isotope separator on-line (ISOL) technique using a particle accelerator system that consists of the Oak Ridge Isochronous Cyclotron (ORIC) driver accelerator, one of the two Injectors for Radioactive Ion Species (IRIS1 or IRIS2) production systems, and the 25-MV tandem electrostatic accelerator that is used for RIB post-acceleration. ORIC provides a light ion beam (proton, deuteron, or alpha) which is directed onto a thick target mounted in a target-ion source (TIS) assembly located on IRIS1 or IRIS2. Radioactive atoms that diffuse from the target material are ionized, accelerated, mass selected, and transported to the tandem accelerator where they are further accelerated to energies suitable for nuclear physics research. RIBs are transported through a beam line system to various experimental end stations including the Recoil Mass Spectrometer (RMS) for nuclear structure research, and the Daresbury Recoil Separator (DRS) for nuclear astrophysics research. HRIBF also includes two off-line ion source test facilities, one low-power on-line ISOL test facility (OLTF), and one high-power on-line ISOL test facility (HPTL). This paper provides an overview and status update of HRIBF, describes the recently completed $4.7M IRIS2 addition and incorporation of laser systems for beam production and purification, and discusses a proposed replacement of the ORIC driver accelerator.

43 PARTICLE ACCELERATORS↗

Negative hydrogen ion beam extracted from a Bernas-type ion source

Negative hydrogen (H{sup -}) ion beam was produced without cesium seeding by a Bernas-type ion source with a coaxial hot cathode. The amount of H{sup -} ion beam current extracted from an original Bernas-type ion source using a hairpin shape filament as a hot cathode was 1 {mu}A with the 0.4 A arc current, while that 300 eV beam energy. In the other hand, H{sup -} ion beam current using the Bernas-type ion source with a coaxial hot cathode reached 4 {mu}A under the same condition. Production efficiency was enhanced by the focused plasma produced by a coaxial hot cathode.

43 PARTICLE ACCELERATORS↗

Design of the injection beamline for the Californium Rare Isotope Breeder Upgrade electron beam ion source charge breeder

The design of the ion injection line connecting the electron beam ion source (EBIS) charge breeder and the Californium Rare Isotope Breeder Upgrade radio frequency quadrupole cooler-buncher at the Argonne Tandem Linear Accelerator System was investigated with particle tracking simulations. The injection line was configured to accommodate several differential pumping sections, individual optical components were optimized to minimize emittance growth, and the ion beam parameters were matched with the EBIS electron beam acceptance to minimize losses upon injection.

43 PARTICLE ACCELERATORS↗

{rho}{sup 0} photoproduction in ultraperipheral relativistic heavy ion collisions at {radical}(s{sub NN})=200 GeV

Photoproduction reactions occur when the electromagnetic field of a relativistic heavy ion interacts with another heavy ion. The STAR Collaboration presents a measurement of {rho}{sup 0} and direct {pi}{sup +}{pi}{sup -} photoproduction in ultraperipheral relativistic heavy ion collisions at {radical}(s{sub NN})=200 GeV. We observe both exclusive photoproduction and photoproduction accompanied by mutual Coulomb excitation. We find a coherent cross section of {sigma}(AuAu{yields}Au*Au*{rho}{sup 0})=530{+-}19(stat.){+-}57(syst.) mb, in accord with theoretical calculations based on a Glauber approach, but considerably below the predictions of a color dipole model. The {rho}{sup 0} transverse momentum spectrum (p{sub T}{sup 2}) is fit by a double exponential curve including both coherent and incoherent coupling to the target nucleus; we find {sigma}{sub inc}/{sigma}{sub coh}=0.29{+-}0.03(stat.){+-}0.08(syst.). The ratio of direct {pi}{sup +}{pi}{sup -} to {rho}{sup 0} production is comparable to that observed in {gamma}p collisions at HERA and appears to be independent of photon energy. Finally, the measured {rho}{sup 0} spin helicity matrix elements agree within errors with the expected s-channel helicity conservation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distinguishing enantiomeric amino acids with chiral cyclodextrin adducts and structures for lossless ion manipulations

Enantiomeric molecular evaluations remain an enormous challenge for current analytical techniques. To date, derivatizations strategies and long separation times are generally required in these studies, and the development and implementation of new approaches is greatly desired to increase speed and distinguish currently unresolvable compounds. Herein, we describe a method using chiral cyclodextrin adducts and structures for lossless ion manipulations (SLIM) ion mobility to achieve rapid, high resolution separations of D and L enantiomeric amino acids. In the analyses, chiral cyclodextrin adducts are added to each sample. Two cyclodextrins were found to sandwich each amino acid and form host-guest noncovalent complexes that were distinct for each D and L amino acid pair studied and thus separable with ion mobility (IM) in SLIM devices. The SLIM was also used to accumulate much larger ion populations than previously feasible for evaluation and therefore allow enantiomeric measurements of higher sensitivity and resolution than previously reported by any other IM-based approach.

chiral separations, cyclodextrins, enantiomers, io↗

Structural Studies of Fucosylated N-Glycans by Ion Mobility Mass Spectrometry and Collision-Induced Fragmentation of Negative Ions

There is considerable potential for the use of ion mobility mass spectrometry in structural glycobiology due in large part to the gas-phase separation attributes not typically observed by orthogonal methods. Here, we evaluate the capability of traveling wave ion mobility combined with negative ion collision-induced dissociation to provide structural information on N-linked glycans containing multiple fucose residues forming the Lewis{sup x} and Lewis{sup y} epitopes. These epitopes are involved in processes such as cell-cell recognition and are important as cancer biomarkers. Specific information that could be obtained from the intact N-glycans by negative ion CID included the general topology of the glycan such as the presence or absence of a bisecting GlcNAc residue and the branching pattern of the triantennary glycans. Information on the location of the fucose residues was also readily obtainable from ions specific to each antenna. Some isobaric fragment ions produced prior to ion mobility could subsequently be separated and, in some cases, provided additional valuable structural information that was missing from the CID spectra alone. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synergistically-enhanced ion track formation in pre-damaged strontium titanate by energetic heavy ions

Latent ion tracks created by energetic heavy ions (12 MeV Ti to 946 MeV Au) in single crystal SrTiO 3 are investigated in this paper using Rutherford backscattering spectrometry and scanning transmission electron microscopy. The results demonstrate that pre-existing irradiation damage, introduced via elastic collision processes, interacts synergistically with the electronic energy deposition from energetic heavy ions to enhance formation of latent ion tracks. The average amorphous cross-section increases with the level of pre-damage and is linearly proportional to the electronic energy loss of the ions, with a slope dependent on the pre-damage level. For the highest energy ions (629 MeV Xe and 946 MeV Au), the tracks are continuous over the pre-damaged depth, but become discontinuous beyond the pre-damaged region. Finally, this work provides new understanding and insights on ion-solid interactions that significantly impact the interpretation of latent track formation processes, models of amorphization, and the fabrication of electro-ceramic devices.

36 MATERIALS SCIENCE↗

Interfacial interactions between polymers and selective adsorbents influence ion transport properties of boron scavenging ion-exchange membranes

The recent emergence of adsorptive ion-exchange membranes (IEMs), designed by the synergistic integration of highly selective porous aromatic frameworks (PAFs) with ion-exchange polymers, has enabled simultaneous desalination and targeted removal of specific solutes (e.g., mercury, iron, boron, etc.). While the addition of highly selective PAFs to IEMs yields membranes with entirely new functions, PAF-polymer interactions, and the effects of such interactions on ion transport properties of the membranes, are not well understood. In this study, we developed cross-linked adsorptive cation- and anion-exchange membranes (CEMs and AEMs) for simultaneous desalination and boron removal via in-situ formation of the cross-linked polymer network around the boron selective PAF particles. Here we systematically investigated the influence of PAF loading level on PAF-polymer interactions as well as the equilibrium and transport properties of the adsorptive IEMs. The interactions between the PAF and the ion-exchange polymer matrix differed for the CEMs and AEMs due to differences in the fixed charge group chemistry. Notably, the sulfonate groups of the CEMs can form hydrogen bonds with the hydroxyl groups of the PAF, while the quaternary ammonium groups in the AEMs cannot. These differences in interfacial interactions did not significantly impact counter-ion transport across the adsorptive IEMs but had a significant influence on co-ion transport, which affected the counter-ion/co-ion selectivity of the membranes. The selectivity of the adsorptive CEMs decreased while that of the adsorptive AEMs increased with PAF loading level. The results of this study underscore the importance of controlling interfacial interactions when designing adsorptive IEMs for simultaneous water desalination and solute capture and recovery.

36 MATERIALS SCIENCE↗

Isotopic Effect on Ion Mobility and Separation of Isotopomers by High-Field Ion Mobility Spectrometry

Since early 1900-s, when vacuum techniques and ion detectors first enabled investigations of gas-phase ions, two approaches to their separation and characterization have emerged - mass spectrometry (MS) and ion mobility spectrometry (IMS).1,2 Though both exploit that distinct charged species move in electric fields differently, MS is performed in vacuum and is based only on the ion mass/charge (m/q) ratio while IMS involves sufficiently dense buffer gases and relies on ion transport properties. The first major discovery enabled by MS was the existence of isotopes by Thomson and Aston,3 and isotopic analyses have since been integral to MS. In particular, the preparative separation of U isotopes using Lawrence’s Calutron was the first industrial application of MS,4 and isotopic labeling is key to MS quantification methods. With IMS, the issue of isotopes was largely ignored as the resolving power (R) was generally too low for their separation. Here, we demonstrate that recently developed high-resolution differential IMS can separate isotopic molecular ions, including nominal isobars with different isotopic content and isotopomers. This capability may enable a new method for isotope separation in a small-scale format at ambient pressure and aid localization of labeled sites in various molecules. Perhaps most importantly, the isotopic shifts depend on the labeled atom position and thus may contain the kind of detailed structural information that is available in solution or solid state using tools such as NMR but has not generally been obtainable for gas-phase ions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-Ion Complexes and Competition from Bulky BArF – Anions for Chloride Binding in Ion Pairing Conditions

Cationic charges have long been used to enhance anion binding. Embedding charge introduces strong ion pairing for target anions but also for off-target ions, ultimately generating a mixture of multi-ion species that are hard to identify and quantify. While many sidestep this problem using polar solvents and weakly coordinating ions, these approaches exclude a substantial cross-section of conditions found in applications spanning recognition, assembly, separations, templation, and catalysis. To confront this complexity, we study the binding of an anion to a cationic receptor featuring low shape complementarity in a low-polarity solvent to maximize ionic interactions. We prepared the receptor as a salt of the weakly coordinating tetrakis­[3,5-bis­(trifluoromethyl)­phenyl]­borate (BArF – ) anion and studied the binding of small chloride (Cl – ) and medium-sized iodide (I – ) anions. Surprisingly, the use of the bulky BArF – anion does not suppress ion pairing interactions, with 65% of the receptor being paired at 0.5 mM in dichloromethane. We observe multi-ion receptor-Cl – complexes (2:1, 1:1, 1:2), reinforcing the complexity that emerges when working in low-polarity media. Here, we reveal the dependence of affinity on anion charge density and size and that bulky BArF – counteranions compete for chloride binding. These studies reveal the noninnocence of BArF – anions and strategies to quantify multi-ion species.

Ion pairing↗

In Situ Study of Particle Precipitation in Metal-Doped CeO2 during Thermal Treatment and Ion Irradiation for Emulation of Irradiating Fuels

Metallic particles formed in oxide fuels (e.g., UO 2 ) during neutron irradiation have an adverse impact on fuel performance. A fundamental investigation of particle precipitation is needed to predict the fuel performance and potentially improve fuel designs and operations. In this study, we report on the precipitation of Mo-dominant β-phase particles in polycrystalline CeO 2 (surrogate for UO 2 ) films doped with Mo, Pd, Rh, Ru, and Re (surrogate for Tc). In situ heating scanning transmission electron microscopy indicates that particle precipitation starts at ~1073 K with a limited particle growth to ~10 nm. While particle concentration increases with increasing temperature, particle size remains largely unchanged up to 1273 K. There is a dramatic change in the microstructure following vacuum annealing at 1373 K, probably due to phase transition of reduced cerium oxide. At the high temperature, particles grow up to 75 nm or larger with distinctive facets. The particles are predominantly composed of Mo with a body-centered cubic structure (β phase). An oxide layer was observed after storage at ambient conditions. In situ heating X-ray photoelectron spectroscopy reveals an increasing reduction of Ce charge state from 4+ to 3+ in the doped CeO 2 film at temperatures from 673 to 1273 K. In situ ion irradiation transmission electron microscopy with 2 MeV Al 2+ ions up to a dose of ~20 displacements per atom at nominally room temperature does not lead to precipitation of visible particles. However, irradiation with 1.7 MeV Au 3+ ions to ~10 dpa at 973 K produces ~2 nm sized pure Pd particles; Au 3+ irradiation at 1173 K appears to result in precipitates of ~6 nm in size. Some of the defects produced by ion irradiation could be nucleation sites for precipitation, leading to generation of smaller particles with a higher concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Specific Ion Effects in Lanthanide–Amphiphile Structures at the Air–Water Interface and Their Implications for Selective Separation

The use of surfactants to attract dissolved ions to water surfaces and interfaces is an essential step in both solvent-based and solvent-free separation processes. Here, we have studied the interactions of lanthanide ions in the aqueous subphase with monolayers of dihexadecyl phosphate at air–water interfaces. With heavier lanthanides (atomic number Z ≥ 65) in the subphase, the floating layer can be compressed to an area/molecule of about half the molecular cross section, indicating bilayer formation. X-ray fluorescence and reflectivity data support this conclusion. In the presence of lighter lanthanides (Z < 65), only monolayers are observed. Subphase-concentration-dependent studies using Er 3+ (heavier) and Nd 3+ (lighter) lanthanides show a stepwise progression, with ions attaching to the monolayer only when the solution concentration is >3 × 10 –7 M. Above ~10 –5 M, bilayers form but only in the presence of the heavier lanthanide. Grazing incidence X-ray diffraction shows evidence of lateral ion–ion correlations in the bilayer structure but not in monolayers. Explicit solvent all-atom molecular dynamics simulations confirm the elevated ion–ion correlation in the bilayer system. This bilayer structure isolates heavier lanthanides but not lighter lanthanides from an aqueous solution and is therefore a potential mechanism for the selective separation of heavier lanthanides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Caesium Free Negative Ion Sources for Neutral Beam Injectors: a Study of Negative Ion Production on Graphite Surface in Hydrogen and Deuterium Plasma

Negative ion generation on HOPG graphite surface has been studied in hydrogen and deuterium plasma. We measure Ion Distribution Function (IDF) of negative ions coming from graphite surface bombarded by positive ions in H{sub 2}/D{sub 2} plasmas. We showed that negative ions flux was proportional to positive ion flux and was strongly dependant on impinging energy. IDF study shows two generation mechanisms are involved: sputtering of adsorbed H/D as negative ions and, in a less important way, double electron capture. We compare H{sub 2}/D{sub 2} plasmas, and point out isotopic effect between H{sup -} and D{sup -} production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion spectrometer composed of time-of-flight and Thomson parabola spectrometers for simultaneous characterization of laser-driven ions

An ion spectrometer, composed of a time-of-flight spectrometer (TOFS) and a Thomson parabola spectrometer (TPS), has been developed to measure energy spectra and to analyze species of laser-driven ions. Two spectrometers can be operated simultaneously, thereby facilitate to compare the independently measured data and to combine advantages of each spectrometer. Real-time and shot-to-shot characterizations have been possible with the TOFS, and species of ions can be analyzed with the TPS. The two spectrometers show very good agreement of maximum proton energy even for a single laser shot. The composite ion spectrometer can provide two complementary spectra measured by TOFS with a large solid angle and TPS with a small one for the same ion source, which are useful to estimate precise total ion number and to investigate fine structure of energy spectrum at high energy depending on the detection position and solid angle. Advantage and comparison to other online measurement system, such as the TPS equipped with microchannel plate, are discussed in terms of overlay of ion species, high-repetition rate operation, detection solid angle, and detector characteristics of imaging plate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of helium ion production in constricted direct current plasma ion source with layered-glows

Generation of helium ions is experimentally investigated with a constricted direct current (DC) plasma ion source operated at layered-glow mode, in which electrons could be accelerated through multiple potential structures so as to generate helium ions including He{sup 2+} by successive ionization collisions in front of an extraction aperture. The helium discharge is sustained with the formation of a couple of stable layers and the plasma ball with high density is created near the extraction aperture at the operational pressure down to 0.6 Torr with concave cathodes. The ion beam current extracted with an extraction voltage of 5 kV is observed to be proportional to the discharge current and inversely proportional to the operating pressure, showing high current density of 130 mA/cm{sup 2} and power density of 0.52 mA/cm{sup 2}/W. He{sup 2+} ions, which were predicted to be able to exist due to multiple-layer potential structure, are not observed. Simple calculation on production of He{sup 2+} ions inside the plasma ball reveals that reduced operating pressure and increased cathode area will help to generate He{sup 2+} ions with the layered-glow DC discharge.

74 ATOMIC AND MOLECULAR PHYSICS↗

Improved ion implant fluence uniformity in hydrogen enhanced glow discharge plasma immersion ion implantation into silicon

Enhanced glow discharge plasma immersion ion implantation does not require an external plasma source but ion focusing affects the lateral ion fluence uniformity, thereby hampering its use in high-fluence hydrogen ion implantation for thin film transfer and fabrication of silicon-on-insulator. Insertion of a metal ring between the sample stage and glass chamber improves the ion uniformity and reduces the ion fluence non-uniformity as the cathode voltage is raised. Two-dimensional multiple-grid particle-in-cell simulation confirms that the variation of electric field inside the chamber leads to mitigation of the ion focusing phenomenon and the results are corroborated experimentally by hydrogen forward scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗