Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

AI-optimized detector design for the future Electron-Ion Collider: the dual-radiator RICH case

Advanced detector R&D requires performing computationally intensive and detailed simulations as part of the detector-design optimization process. Here, we propose a general approach to this process based on Bayesian optimization and machine learning that encodes detector requirements. As a case study, we focus on the design of the dual-radiator Ring Imaging Cherenkov (dRICH) detector under development as a potential component of the particle-identification system at the future Electron-Ion Collider (EIC). The EIC is a US-led frontier accelerator project for nuclear physics, which has been proposed to further explore the structure and interactions of nuclear matter at the scale of sea quarks and gluons. We show that the detector design obtained with our automated and highly parallelized framework outperforms the baseline dRICH design within the assumptions of the current model. Our technique can be applied to any detector R&D, provided that realistic simulations are available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade to Fixed and Translating Scintillation-based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating detectors collected under varying beam conditions validate the utility of the upgrade.

Chen, E. V. [Fermilab]↗

Survey of Neutron Flux Sensors for Monitoring Advanced Reactor Concepts Operating with Low Neutron Fluence Rate and Extended Uninterrupted Lifespans

The purpose of this report is to provide a survey of neutron sensors applicable to the low power levels (low neutron fluence rate) for reactor monitoring and controls. A survey of detectors for reactor power monitoring and controls from various commercial vendors—Reuter Stokes, Framatome, Exosens, and Mirion—is presented in the following sections based on application of reactor power ranges. Detector specifications are provided where available per each of the vendor’s catalogues and specification sheets found on their websites. While this is not an all encompassing list, it provides an example of detector options. Fission chambers and self powered neutron detectors (SPNDs) for in-core application with changes to the neutron-sensitive materials—fissile depots for fission chambers and emitters for SPNDs—for regenerative capabilities will be discussed in the latter sections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full-Array Noise Performance of Deployment-Grade SuperSpec mm-Wave On-Chip Spectrometers

SuperSpec is an on-chip filter bank spectrometer designed for wideband moderate-resolution spectroscopy at millimeter wavelengths, employing TiN kinetic inductance detectors. SuperSpec technology will enable large-format spectroscopic integral field units suitable for high-redshift line intensity mapping and multi-object spectrographs. In previous results, we have demonstrated noise performance in individual detectors suitable for photon noise-limited ground-based observations at excellent mm-wave sites. Here, we present the noise performance of a full R similar to 275 spectrometer measured using deployment-ready RF hardware and software. We report typical noise equivalent powers through the full device of similar to 3x10 -16 W Hz -1/2 at expected sky loadings, which are photon noise dominated. Based on these results, we plan to deploy a six-spectrometer demonstration instrument to the Large Millimeter Telescope in early 2020.

47 OTHER INSTRUMENTATION↗

Neutron Response of the EJ-254 Boron-Loaded Plastic Scintillator

Organic scintillators doped with capture agents provide a detectable signal for neutrons over a broad energy range. This work characterizes the fast and slow neutron response of EJ-254, an organic plastic scintillator with 5 loading by weight. For fast neutrons, the primary mechanism for light generation in organic scintillators is n-p elastic scattering. To study the fast neutron response, the proton light yield of EJ-254 was measured at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a broad-spectrum neutron source and a double time-of-flight technique, the EJ-254 proton light yield was obtained over the energy range of approximately 270 keV to 4.5 MeV and determined to be in agreement with other plastic scintillators comprised of the same polymer base. To isolate the slow neutron response, an AmBe source with polyethylene moderator was made incident on the EJ-254 scintillator surrounded by an array of EJ-309 observation detectors. Events in the EJ-254 target coincident with the signature 477.6 keV γ ray (resulting from de-excitation of the residual 7Li nucleus following boron neutron capture) were identified. Pulse shape discrimination was used to evaluate the temporal differences in the response of EJ-254 scintillation signals arising from γ-ray and fast/slow neutron interactions. Clear separation between γ-ray and fast neutrons signals was not achieved and the neutron capture feature was observed to overlap both the γ-ray and fast neutron bands. Taking into account the electron light nonproportionality, the neutron capture light yield in EJ-254 was determined to be 89.4±1.1 keVee.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RD53A: A large-scale prototype chip for the phase II upgrade in the serially powered HL-LHC pixel detectors

The phase II upgrade of the HL-LHC experiments within the LHC intends to deepen the studies of the Higgs boson and to allow the discovery of further particles by adding an integrated luminosity of about 4000 fb -1 over 10 years of operation. This upgrade would overwhelm the installed pixel detector readout chips with higher hit rates and radiation levels than ever before. To match these extreme requirements the RD53 collaboration, a joint effort between ATLAS and CMS, developed RD53A, a new generation pixel detector readout chip prototype manufactured in a 65 nm CMOS technology. It is half the size of the final pixel chips and designed to meet requirements in the face of 3 GHz/cm 2 hit rate after irradiation to 500 Mrad. The detector is able to use 50×50 μm 2 or 25×100 μm 2 pixels with high readout speed of up to 4 links per chip with 1.28 Gbit/s each. Shunt–LDO regulators integrated on the bottom of the chip provide the required voltages to the two power domains, analog and digital. These regulators enable serial powering of the pixel modules, which is the only feasible, radiation hard scheme to ensure acceptable power cable losses and to stay within the material budget for the future pixel detectors. Finally, an overview of the status and challenges of serial powering and the Shunt–LDO regulator development will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Performance of an InAs Quantum Dot Scintillator with Integrated Photodetector

A new scintillation material composed of InAs quantum dots (QDs) hosted within a GaAs matrix was developed, and its performance with different types of radiation is evaluated. A methodology for designing an integrated photodetector (PD) with a low defect density and that is optically matched to the QD’s emission spectrum is introduced, utilizing an engineered epitaxial InAlGaAs metamorphic buffer layer. The photoluminescence (PL) collection efficiency of the integrated PD is examined using two-dimensional scanning laser excitation. The detector response to 5.5 MeV α-particles and 122 keV photons is presented. Yields of 13 electrons/keV for α-particles and 30–60 electrons/keV for photons were observed. The energy resolution of 12% observed with α-particles was mainly limited by noise- and geometry-related optical losses. The radiation hardness of an InAs QDs hosted within GaAs and a wider band gap AlGaAs ternary alloy was studied under a 1 MeV proton implantation up to a 10 14 cm –2 dose. The integrated PL responses were compared to evaluate PL quenching due to non-radiative defects. The QDs embedded in the AlGaAs demonstrated improved radiation hardness compared to QDs in the GaAs matrix and in the InGaAs quantum wells.

36 MATERIALS SCIENCE↗

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20ps respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CENTAUR - The small- and wide-angle neutron scattering diffractometer/spectrometer for the Second Target Station of the Spallation Neutron Source

CENTAUR has been selected as one of the eight initial instruments to be built at the Second Target Station (STS) of the Spallation Neutron Source at Oak Ridge National Laboratory. It is a small-angle neutron scattering (SANS) and wide-angle neutron scattering (WANS) instrument with diffraction and spectroscopic capabilities. This instrument will maximally leverage the high brightness of the STS source, the state-of-the-art neutron optics, and a suite of detectors to deliver unprecedented capabilities that enable measurements over a wide range of length scales with excellent resolution, measurements on smaller samples, and time-resolved investigations of evolving structures. Notably, the simultaneous WANS and diffraction capability will be unique among neutron scattering instruments in the United States. This instrument will provide much needed capabilities for soft matter and polymer sciences, geology, biology, quantum condensed matter, and other materials sciences that need in situ and operando experiments for kinetic and/or out-of-equilibrium studies. Beam polarization and a high-resolution chopper will enable detailed structural and dynamical investigations of magnetic and quantum materials. CENTAUR’s excellent resolution makes it ideal for low-angle diffraction studies of highly ordered large-scale structures, such as skyrmions, shear-induced ordering in colloids, and biomembranes. Additionally, the spectroscopic mode of this instrument extends to lower momentum transfers than are currently possible with existing spectrometers, thereby providing a unique capability for inelastic SANS studies.

47 OTHER INSTRUMENTATION↗

BeyondPlanck: V. Minimal ADC Corrections for Planck LFI

We describe the correction procedure for Analog-to-Digital Converter (ADC) differential non-linearities (DNL) adopted in the Bayesian end-to-end BEYONDPLANCK analysis framework. This method is nearly identical to that developed for the official Planck Low Frequency Instrument (LFI) Data Processing Center (DPC) analysis, and relies on the binned rms noise profile of each detector data stream. However, rather than building the correction profile directly from the raw rms profile, we first fit a Gaussian to each significant ADC-induced rms decrement, and then derive the corresponding correction model from this smooth model. The main advantage of this approach is that only samples which are significantly affected by ADC DNLs are corrected, as opposed to the DPC approach in which the correction is applied to all samples, filtering out signals not associated with ADC DNLs. The new corrections are only applied to data for which there is a clear detection of the non-linearities, and for which they perform at least comparably with the DPC corrections. Out of a total of 88 LFI data streams (sky and reference load for each of the 44 detectors) we apply the new minimal ADC corrections in 25 cases, and maintain the DPC corrections in 8 cases. All these corrections are applied to 44 or 70 GHz channels, while, as in previous analyses, none of the 30 GHz ADCs show significant evidence of non-linearity. By comparing the BEYONDPLANCK and DPC ADC correction methods, we estimate that the residual ADC uncertainty is about two orders of magnitude below the total noise of both the 44 and 70 GHz channels, and their impact on current cosmological parameter estimation is small. However, we also show that non-idealities in the ADC corrections can generate sharp stripes in the final frequency maps, and these could be important for future joint analyses with the Planck High Frequency Instrument (HFI), Wilkinson Microwave Anisotropy Probe (WMAP), or other datasets. We therefore conclude that, although the existing corrections are adequate for LFI-based cosmological parameter analysis, further work on LFI ADC corrections is still warranted.

79 ASTRONOMY AND ASTROPHYSICS↗

A concept for polarized 3 He targets for high luminosity scattering experiments in high magnetic field environments

In this work, we present the conceptual design of a polarized 3 He target to be used for high luminosity scattering experiments within high magnetic field environments. This two-cell target will take advantage of advancements in optical pumping techniques at high magnetic field to create 60% longitudinally polarized 3 He gas in a pumping cell within a uniform magnetic field above 1 T. By transferring the polarized gas to a cryogenic target cell, the gas density is increased to create a target thickness suitable for high luminosity applications. We discuss the general design of this scheme, and plans for its application in Jefferson Lab’s CLAS12 detector.

3He polarization↗

Development of 17 N as a time-tagged neutron source for calibration of large antineutrino detectors

Large antineutrino detectors hold the potential for remote nuclear reactor monitoring and discovery, which is of great interest for nonproliferation and treaty verification applications. Correlated-particle calibration sources are especially useful for large-volume designs based on detection of inverse beta-decay events, as the timing information of the coincident particles improves background rejection and event reconstruction. 17 N is a promising calibration source since it emits beta-correlated delayed neutrons and can be produced relatively easily using high-energy neutrons. In this work, we examine the feasibility of 17 N as a time-tagged calibration source for large antineutrino detectors. 17 N was produced using a DT neutron generator from a water sample enriched in 17 O, and the observed production rates were found to be consistent with previous measurements of the 17 O(n,p) 17 N reaction cross-section. As a result, time-tagging of 17 N delayed neutrons is demonstrated via beta-neutron coincidence measurements conducted using a specialized beta detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction, installation and operation of ProtoDUNE-SP

The single-phase liquid argon TPC at CERN (ProtoDUNE-SP) is an engineering prototype for the first module of the DUNE far detector. This prototype, which has dimensions of a cube of about 10 m edge, provides full validation of the use of the membrane tank technology for large dimension cryostats. Furthermore, the very high performance of the protoDUNE-SP TPC with more than 500 days of continuous and stable operation, demonstrated the reliability of the LAr detection technology at a scale never tested before. In this talk we will review the main characteristics and milestones of the construction and installation of protoDUNE-SP which provide a series of benchmarks for DUNE. The performance for several different detector working points will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAND - System for on-Axis Neutrino Detection - in the DUNE Near Detector Complex

The DUNE experiment aims to precisely measure the long baseline neutrino oscillation parameters. The DUNE Far Detector consists of four liquid argon time-projection chambers (total LAr mass of 17 kton for each cryostat), that will be installed at the Sanford Underground Research Facility (SURF) in South Dakota, 1300 km from the proton beam target. The Near Detector complex, located at Fermilab, is fundamental for limiting the systematic uncertainties, due to the neutrino/antineutrino flux and to the cross-section. It comprises three complementary detectors: ND-Lar, ND-Gar and SAND (System for on-Axis Neutrino Detection). ND-Lar and ND-Gar can move off-axis, while SAND is the only detector permanently on-axis, whose primary goal is to monitor the beam and to measure the flux. In this talk, the SAND design and the expected performances will be described together with its role within the Near Detector complex for the DUNE physics program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial-velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial-velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm s{sup −1}, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial-velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser fRequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on the radial-velocity precision due to pixel-position nonuniformities and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter–McLaughlin effect.

79 ASTRONOMY AND ASTROPHYSICS↗

A Measurement of Atmospheric Circular Polarization with POLARBEAR

At millimeter wavelengths, the atmospheric emission is circularly polarized owing to the Zeeman splitting of molecular oxygen by the Earth's magnetic field. We report a measurement of the signal in the 150 GHz band using 3 yr of observational data with the POLARBEAR project. Nonidealities of a continuously rotating half-wave plate (HWP) partially convert circularly polarized light to linearly polarized light. While POLARBEAR detectors are sensitive to linear polarization, this effect makes them sensitive to circular polarization. Although this was not the intended use, we utilized this conversion to measure circular polarization. We reconstruct the azimuthal gradient of the circular polarization signal and measure its dependency from the scanning direction and the detector bandpass. We compare the signal with a simulation based on atmospheric emission theory, the detector bandpass, and the HWP leakage spectrum model. We find the ratio of the observed azimuthal slope to the simulated slope is 0.92 ± 0.01(stat) ± 0.07(sys). This ratio corresponds to a brightness temperature of 3.8 mK at the effective band center of 121.8 GHz and bandwidth of 3.5 GHz estimated from representative detector bandpass and the spectrum of Zeeman emission. This result validates our understanding of the instrument and reinforces the feasibility of measuring the circular polarization using the imperfection of continuously rotating HWP. Continuously rotating HWP is popular in ongoing and future cosmic microwave background experiments to modulate the polarized signal. This work shows a method for signal extraction and leakage subtraction that can help measure circular polarization in such experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray Spectroscopy in Low-Power Nuclear Research Reactors

Gamma-ray spectroscopy is an effective technique for radioactive material characterization, routine inventory verification, nuclear safeguards, health physics, and source search scenarios. Gamma-ray spectrometers typically cannot be operated in the immediate vicinity of nuclear reactors due to their high flux fields and their resulting inability to resolve individual pulses. Low-power reactor facilities offer the possibility to study reactor gamma-ray fields, a domain of experiments hitherto poorly explored. In this work, we present gamma-ray spectroscopy experiments performed with various detectors in two reactors: The EPFL zero-power research reactor CROCUS, and the neutron beam facility at the Ohio State University Research Reactor (OSURR). We employed inorganic scintillators (CeBr3), organic scintillators (trans-stilbene and organic glass), and high-purity germanium semiconductors (HPGe) to cover a range of typical—and new—instruments used in gamma-ray spectroscopy. The aim of this study is to provide a guideline for reactor users regarding detector performance, observed responses, and therefore available information in the reactor photon fields up to 2 MeV. The results indicate several future prospects, such as the online (at criticality) monitoring of fission products (like Xe, I, and La), dual-particle sensitive experiments, and code validation opportunities.

Pakari, Oskari V. (ORCID:0000000337048190)↗