At least 631 records · Page 35

Mapping the combustion modes of a dual-fuel compression ignition engine

Compression-ignition (CI) engines can produce higher thermal efficiency (TE) and thus lower carbon dioxide (CO 2 ) emissions than spark-ignition (SI) engines. Unfortunately, the overall fuel economy of CI engine vehicles is limited by their emissions of nitrogen oxides (NO x ) and soot, which must be mitigated with costly, resource- and energy-intensive aftertreatment. NO x and soot could also be mitigated by adding premixed gasoline to complement the conventional, non-premixed direct injection (DI) of diesel fuel in CI engines. Several such “dual-fuel” combustion modes have been introduced in recent years, but these modes are usually studied individually at discrete conditions. This paper introduces a mapping system for dual-fuel CI modes that links together several previously studied modes across a continuous two-dimensional diagram. This system includes the conventional diesel combustion (CDC) and conventional dual-fuel (CDF) modes; the well-explored advanced combustion modes of HCCI, RCCI, PCCI, and PPCI; and a previously discovered but relatively unexplored combustion mode that is herein titled “Piston-split Dual-Fuel Combustion” or PDFC. Tests show that dual-fuel CI engines can simultaneously increase TE and lower NO x and/or soot emissions at high loads through the use of Partial HCCI (PHCCI). At low loads, PHCCI is not possible, but either PDFC or RCCI can be used to further improve NO x and/or soot emissions, albeit at slightly lower TE. These results lead to a “partial dual-fuel” multi-mode strategy of PHCCI at high loads and CDC at low loads, linked together by PDFC. Drive cycle simulations show that this strategy, when tuned to balance NO x and soot reductions, can reduce engine-out CO 2 emissions by about 1% while reducing NO x and soot by about 20% each with respect to CDC. This increases emissions of unburnt hydrocarbons (UHC), still in a treatable range (2.0 g/kWh) but five times as high as CDC, requiring changes in aftertreatment strategy.

Engineering↗

Experimental investigation on the coolability of nuclear reactor debris beds using seawater

During the Fukushima nuclear reactor accident, seawater was injected into the reactor core to cool the decay heat from the heat generating porous debris bed. However, the impact of dissolved salts in water on the coolability of a debris bed is not well understood. This paper is one of the first works to investigate the cooling mechanisms for debris bed using seawater. An experimental system was built where the packed bed test section was volumetrically heated via a high frequency induction heater. The temperature along the axis of the test section was measured using a high resolution temperature sensor based on Optical Frequency Domain Reflectometry. Experimental results show that the dryout heat flux increases with an increase in concentration, with pure water having a dryout volumetric heat flux of 1.8 MW/m and salt water of concentration 7% having a dryout volumetric heat flux of 2.8 MW/m. However, this enhanced coolability using salt water is short term, as the crystallization fouling mechanism becomes significant over time and leads to gradual temperature excursion in the bed. The fouling mechanism eventually leads to a cross section of the debris bed to plug with the deposited salts, and this leads to a pressure build up in the lower regions of the debris bed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical evaluation of photosensitive tracers as a strategy for separating surface and subsurface transient storage in streams

For this work, we numerically evaluated photosensitive tracers as a potential strategy for separating the effects of surface and hyporheic storage zones (SSZs and HSZs, respectively) on stream corridor transport. Correctly separating HSZ and SSZ effects is critical to estimating the hydro-biogeochemical function of a stream because HSZs and SSZs expose solutes to significantly different biogeochemical conditions, like sunlight exposure, microbial processes, and oxygen availability. Our numerical experiments used a multiscale river-corridor transport model implemented in the ATS code, which accommodates multiple storage zones with distinct travel time distributions and biogeochemical reactions. For parameter inferences, we used Bayesian inverse modeling. We found that breakthrough curves for photo-decaying tracers from day and night injection can delineate surface and hyporheic transient storage contributions, but only when interpreted jointly through a two-storage zone model. Numerical experiments that used only daytime injection or interpreted breakthrough curves with a single storage zone model yielded good fit to breakthrough curves, but parameter estimates were biased and controlling processes misattributed, examples of good model fits for the wrong reasons. Using those biased parameter estimates in reactive transport simulations resulted in significantly different projections of denitrification, which underscores the potential for stream function to be mischaracterized if tracer tests are interpreted through an inappropriately simplified model for transient storage. More generally, this study highlights the role of modeling in evaluating the experimental design and identifying the potential of system mischaracterization and its implications.

54 ENVIRONMENTAL SCIENCES↗

Joint Estimation of Topology and Injection Statistics in Distribution Grids with Missing Nodes

Optimal operation of distribution grid resources relies on accurate estimation of its state and topology. Practical estimation of such quantities is complicated by the limited presence of real-time meters. This article discusses a theoretical framework to jointly estimate the operational topology and statistics of injections in radial distribution grids under limited availability of nodal voltage measurements. In particular, we show that our proposed algorithms are able to provably learn the exact grid topology and injection statistics at all unobserved nodes as long as they are not adjacent. The algorithm design is based on novel ordered trends in voltage magnitude fluctuations at node groups, that are independently of interest for radial physical flow networks. The complexity of the designed algorithms is theoretically analyzed and their performance is validated using both linearized and nonlinear ac power flow samples in test distribution grids.

97 MATHEMATICS AND COMPUTING↗

Real-time Intrusion Detection for High-bandwidth Research Networks using Unsupervised Deep Learning

Nowadays, data generated by large-scale scientific experiments are on the scale of petabytes per month. These data are transferred through dedicated high-bandwidth networks across distributed collaboration sites for processing, storage, and analysis. Like general purpose networks, research networks experience attacks. However, monitoring traffic in such high-bandwidth network environments is challenging with conventional deep packet inspection (DPI)- based network intrusion detection systems (NIDS). Recently, machine learning (ML) algorithms have shown potential in detecting anomalous patterns with better generalizability and faster speed. Compared to the general purpose networks, traffic movement in research network is less volatile and more likely to benefit from the ML-based anomaly analysis. We present ThunderSecure, an efficient AI-powered system for detecting anomalies in 100G research networks. ThunderSecure implements a high-throughput packet processing infrastructure using multi-cores and GPUs. It takes time-series statistics from a variety of network measurements and uses 2D Convolutional Neural Network (CNN) to explore both spatial and temporal dependencies in network data stream. Patterns of science data traffic are learned with a one-class neural network, which blends an Adversarial Autoencoder (AAE) with Gaussian mixture density estimation. Testing traffic flows exhibiting significant deviations from the learned baseline of normality are marked as anomalies. We trained ThunderSecure on hundreds of billions of science data packets recorded from a 100G research network at Fermi National Accelerator Laboratory. The detection performance was evaluated on traffic captured from the same research network days and weeks after the training with different types of attack flows injected. To the best of our knowledge, this is the first ML work in the area of network anomaly detection that has been validated on such extreme scale datasets. Results show that ThunderSecure can recognize science data traffic that are captured long after the training and make nearly certain detection on those with anomalous flows injected, even in the case when the anomaly-to-normal mixing ratio is 0.1%.

Gong, Qian↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ducted Fuel Injection vs. Conventional Diesel Combustion: Extending the Load Range in an Optical Engine with a Four-Orifice Fuel Injector

Ducted fuel injection (DFI) is a technique to attenuate soot formation in compression ignition engines relative to conventional diesel combustion (CDC). The concept is to inject fuel through a small tube inside the combustion chamber to reduce equivalence ratios in the autoignition zone relative to CDC. DFI has been studied at loads as high as 8.5 bar gross indicated mean effective pressure (IMEP g ) and as low as 2.5 bar IMEP g using a four-orifice fuel injector. Across previous studies, DFI has been shown to attenuate soot emissions, increase NO x emissions (at constant charge dilution), and slightly decrease fuel conversion efficiencies for most tested points. This study expands on the previous work by testing 1.1 bar IMEPg (low-load/idle) conditions and 10 bar IMEPg (higher-load) conditions with the same four-orifice fuel injector, as well as examining potential causes of the degradations in NO x emissions and fuel conversion efficiencies. DFI and CDC are directly compared at each operating point in the study. At the low-load condition, the intake charge dilution was swept to elucidate the soot and NO x performance of DFI. The low-load range is important because it is the target of impending, more-stringent emissions regulations, and DFI is shown to be a potentially effective approach for helping to meet these regulations. The results also indicate that DFI likely has slightly decreased fuel conversion efficiencies relative to CDC. We find that the increase in NO x emissions with DFI is likely due to longer charge gas residence times at higher temperatures, which arise from shorter combustion durations and advanced combustion phasing relative to CDC.

42 ENGINEERING↗

DECOVALEX-2023: Task A Final Report

Task A, also known as HGFrac, examines the fracturing processes that may occur in the Callovo-Oxfordian claystone (COx) in the context of the high-level (HLW) and intermediate-level long-lived (ILW-LL) radioactive waste repository in France. Understanding these processes and improving numerical models to reproduce them will aid in the design, optimization, and safety of the repository. Heat and gas fracturing are studied in two independent subtasks following a stepwise approach: laboratory tests/benchmark exercises, in-situ experiment, and finally, an application case. The in-situ heater experiment aimed to thermally induce a hydraulic fracture; temperature and pore pressure were monitored to detect any evidence of fracturing. The in-situ gas injection experiment aimed to study the effect of the stress orientation and gas injection kinetics on the gas fracturing process. The occurrence of fracturing was monitored by gas pressure measured in the injection interval. In both experiments, the excavation-induced fracture network around the heater/injection boreholes played an important role in the reduction of the compressive stress state, leading to both a tensile and shear failure response of the COx. During the first two years of the project, the research teams working on each task developed and/or proposed numerical approaches for reproducing the occurrence of fracturing in the in-situ experiments. The failure criteria were defined by reproducing the measurements from laboratory extension tests for the heat fracturing subtask. In the gas fracturing subtask, their approaches were used for simulating several benchmark exercises, and an inter-comparison between models was carried out. In both tasks, the developed approaches were compared with a simplified approach considering poro-elasticity for the mechanical behaviour of the COx. Most of the developed approaches are based on a continuous medium that takes into account variations in hydraulic properties due to mechanical degradation, such as plastic deformation or damage. Other approaches implicitly modelled weak planes or embedded discontinuities to reproduce fracture propagation. The potential for fracture initiation was also studied through of a discrete approach. In the second half of the project, the research teams mainly focused on interpretative modelling of two in-situ experiments and a blind prediction exercise to test their respective approaches. The models developed by the research teams were also applied at the repository scale to evaluate fracture initiation in a case study under vi unfavourable conditions, particularly in terms of spacing between High-Level Waste cells. The results showed that the poro-elasticity approach could be an efficient tool for understanding the main processes occurring in the COx. One example is the explicit representation of the excavation-induced fracture network around the boreholes, which yielded acceptable results compared to the measurement data. However, advanced approaches were needed to evaluate the potential increase of the excavation-induced fracture network extend and better understand fracture initiation. The stress analyses carried out by the teams revealed that hydraulic boundary conditions had a strong impact on fracture initiation in the heater experiment. Furthermore, in most cases, the results required higher pore pressure increments to reach fracturing than those measured in the experiment. This implies that the measurements may have been biased by the packer’s capacity to fully isolate the piezometric chambers, leading to lower pressures. On the contrary, there was no agreement on the fracturing mode, as some reported either shear or tensile fracturing, while others reported a combination of the two modes. In the case of gas fracturing, the research teams were limited to the comparison of a single point, which complicated their task. Nonetheless, the numerical results were able to reproduce the measurements and capture processes such as longitudinal gas flow through the excavation-induced fracture network, as suggested by some evidence in the observation piezometric chambers. The numerical models also agreed with the measurements in the sense of higher probability of developing along the injection borehole than radially towards the sound rock. The approaches developed by the research teams showed that they are capable of analysing and reproducing fracture initiation in the COx. However, areas of future work should focus on the fracture propagation and fracture aperture, which were out of the scope of this task. To this end, additional data must be gathered for the parameter characterisation and validation of the numerical models. Nonetheless, various approaches showed promising results as they were able to reproduce fracture development under certain conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predictive Modeling of NOx Emissions from Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blends Using Flame Imaging and Machine Learning

This research paper explores the use of machine learning to relate images of flame structure and luminosity to measured NOx emissions. Images of reactions produced by 16 aero-engine derived injectors for a ground-based turbine operated on a range of fuel compositions, air pressure drops, preheat temperatures and adiabatic flame temperatures were captured and postprocessed. The experimental investigations were conducted under atmospheric conditions, capturing CO, NO and NOx emissions data and OH* chemiluminescence images from 27 test conditions. The injector geometry and test conditions were based on a statistically designed test plan. These results were first analyzed using the traditional analysis approach of analysis of variance (ANOVA). The statistically based test plan yielded 432 data points, leading to a correlation for NOx emissions as a function of injector geometry, test conditions and imaging responses, with 70.2% accuracy. As an alternative approach to predicting emissions using imaging diagnostics as well as injector geometry and test conditions, a random forest machine learning algorithm was also applied to the data and was able to achieve an accuracy of 82.6%. This study offers insights into the factors influencing emissions in ground-based turbines while emphasizing the potential of machine learning algorithms in constructing predictive models for complex systems.

08 HYDROGEN↗

Subtask 1.5 – CO2 Injection Monitoring with an Optimized Scalable, Automated, Semipermanent Seismic Array

The scalable, automated, semipermanent seismic array (SASSA) method is a flexible and relatively cost-effective surface geophysical method for regular time-lapse monitoring of the movement of injected carbon dioxide (CO2) in a reservoir for CO2 enhanced oil recovery (EOR) or geologic CO2 storage operations. It has the advantages of a low-environmental-footprint while monitoring regions of a reservoir from the surface without the need for a regular grid distribution of receivers. Automated data collection is possible. As only time-lapse amplitude changes at the reservoir level due to CO2 movement within the reservoir are monitored, the turnaround time to deliver results from the SASSA method can be short, without the need for long, time-consuming data-processing workflows. As data is collected and processed, incremental information can be provided to the field operator. The Energy & Environmental Research Center (EERC) conducted a SASSA field test from September 2018 to November 2020 in a portion of the Bell Creek Field in Montana, which implemented new CO2 EOR field activities during the study period. Lessons learned from a proof-of-concept study were incorporated to improve the data quality of the SASSA method and demonstrate the viability of the technology. The EERC implemented several enhancements to improve data quality, including 1) an iterative survey design, which allowed placing the receivers in strategic locations where the movement of the CO2 in the reservoir could be tracked with minimum interference by the cultural noise in the study area; 2) the use of powerful seismic sources in the form of surface orbital vibrators, and 3) data acquisition during optimal periods. History-matched reservoir simulation was performed to predict gas saturation and pressure response induced by CO2 injection in the study area. The results were compared with the SASSA-measured responses to CO2 injection as a partial validation technique. A match between the two methods was observed for most of the SASSA points predicted to have intersected a CO2 saturation change. The validated results provide confidence that the SASSA method can be used independently as a CO2 saturation monitoring technique. As data are collected and processed, incremental information can be provided to the field operator. The critical components of the SASSA workflow for a successful application of the method are the following: Iterative survey design with information about CO2 injection activities from the oilfield operator. A detailed CO2 injection plan is the key driver to select the strategic monitoring location of the SASSA sensors. After this information is incorporated in the initial distribution of sources and receivers in the study area, high-resolution satellite images are used to identify ground locations not affected by cultural noise sources, such as power lines, pipelines/flow lines, or roadways. In the next iteration of the survey design, a scouting trip to the study area is needed to understand more details of the noise sources identified in the previous step and the intensity of the field activities that can also generate noise during the monitoring. Integrating the information from the scouting trip into the survey design to select the optimum source and receiver locations is the final step. Noise attenuation. The variety of noise types during seismic monitoring of an oil field is enormous. Tailored noise characterization and processing at a node-by-node level can enhance the performance and sensitivity of the SASSA technique. Future advancements that could improve the efficiency and application of the SASSA technology include: Gaining a better understanding of the noise field produced by the seismic source to aid the choice of receiver location. Surface noise from the source can overwhelm the small signal changes due to CO2 that the SASSA method measures. Improved data-processing workflow to automatically analyze and adapt to dynamic noise conditions associated with industrial settings. This subtask was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE- FE0024233.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Probabilistic Voltage Sensitivity Analysis to Quantify Impact of High PV Penetration on Unbalanced Distribution System

From an operational and planning perspective, it is important to quantify the impact of increasing penetration of photovoltaics on the distribution system. Most existing impact assessment studies are scenario-based where derived results are scenario specific and not generalizable. Moreover, stochasticity in the temporal behavior of spatially distributed PVs requires a large number of scenarios that increase with the size of the network and the level of penetration. Therefore, we propose a new computationally efficient analytical framework of voltage sensitivity analysis that allows for stochastic analysis of voltage change due to random changes in PV generation. We first derive an analytical approximation for voltage change at any node of the network due to change in power at other nodes in an unbalanced distribution network. The quality of this approximation is reinforced via bounds on the approximation error. Then, we derive the probability distribution of voltage change at a certain node due to random changes in power injections/consumptions at multiple locations of the network. The accuracy of the proposed PVSA is illustrated using a modified version of the IEEE 37 bus test system. As a result, the proposed PVSA can serve as a powerful tool for proactive monitoring/control and ease the computational burden associated with perturbation based cybersecurity mechanisms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Oxygenated Fuel Blending Effects in a Mixing-Controlled Compression-Ignition Engine Equipped with Ducted Fuel Injection [Slides]

Continued creation of harmful emissions such as NO x and soot from compression-ignition engines utilizing mixing-controlled combustion systems (i.e., diesel engines) remains a problem and is the subject of on-going research. The inherently high efficiency, relatively low cost, and numerous other desirable attributes of such engines, coupled with a widely supported infrastructure, motivates their continued advancement. Recently, a scientifically distinct and mechanically simple technology called ducted fuel injection (DFI) has shown a robust ability to allow such engines to operate with simultaneously low engine-out soot and NO x emissions when it is employed with simulated exhaust-gas recirculation. To better understand the property ranges of sustainable, oxygenated-fuel blending stocks that will most improve engine performance, two oxygenated blendstocks were separately blended with a commercial diesel base fuel and tested within a heavy-duty diesel optical engine equipped with a four-duct DFI configuration. Conventional and crank-angle-resolved optical diagnostics were used to elucidate the effects of fuel ignition quality, oxygenate molecular structure, and overall oxygen content on engine performance.

33 ADVANCED PROPULSION SYSTEMS↗

Supersaturating Water with CO 2 via Nanobubble Formation

The subsurface storage of CO 2 is limited by the solubility of CO 2 in brine. One proposed solution to increase the volume fraction of CO 2 in a reservoir is by injecting the CO 2 at high pressure in nanobubble form. These nanobubbles, diameter <50 nm, would be small enough that they would only undergo Brownian motion, preventing them rising under buoyancy and escaping the formation. There has also been some experimental work that suggests the present of these nanobubbles significantly (~2x) increase the solubility of gaseous CO 2 in the aqueous phase. NETL and ExxonMobil will test the viability of this strategy to increase the volume fraction of CO 2 in a subsurface reservoir, determine the stability of these nanobubble systems, and understand the ultimate limits of increasing the CO 2 volume fraction.

54 ENVIRONMENTAL SCIENCES↗

Influence of sequential stimulation practices on geochemical alteration of shale

Water-based hydraulic fracturing fluids (HFFs) can chemically interact with formation shale, resulting in altered porosity and permeability of the host rock. Experimental investigations of spatial and temporal shale-HFF interactions are helpful in interpreting chemical compositions of the injectate, as well as predicting alteration of hydraulic properties in the reservoir due to mineral dissolution and precipitation. Most bench-top experiments designed to study shale-HFF chemical interactions, either using batch reactors or flow-through setups, are carried out assuming that the acid spearhead has already become mixed with neutral HFFs. During operations, however, HFFs are typically injected according to a sequenced pumping schedule, starting with a concentrated acid spearhead, followed by multiple additions of near-neutral pH HFFs containing chemical amendments and proppant. In this study, we use geochemical modeling to consider whether this pre-mixed experimental protocol provides results directly comparable to a sequential discrete fluid-shale interaction protocol. Our results show that for the batch system, the transient evolution in major ion concentrations is faster with the sequential procedure. After 2 h of reaction time, the two protocols converge to the same aqueous concentrations. In a flow-through geometry, the pre-mixed model predicts extensive chemical alteration close to the injection point but negligible alteration downstream. In contrast, the sequential model predicts mineral reactions over hundreds of meters along the flow path. The extent of shale alteration in the sequential model at a given location depends on shale mineralogy and where the acid spearhead resides during the shut-in period. The predictive model developed in this study can help experimentalists to design bench-top tests and operators to better translate the results of laboratory experiments into practical applications.

Li, Qingyun↗

Oil Recovery Prediction for Polymer Flood Field Test of Heavy Oil on Alaska North Slope Via Machine Assisted Reservoir Simulation

The first ever polymer flood field pilot to enhance the recovery of heavy oils on the Alaska North Slope is ongoing. This study constructs and calibrates a reservoir simulation model to predict the oil recovery performance of the pilot through machine-assisted reservoir simulation techniques. To replicate the early water breakthrough observed during waterflooding, transmissibility contrasts are introduced into the simulation model, forcing viscous fingering effects. In the ensuing polymer flood, these transmissibility contrasts are reduced to replicate the restoration of injection conformance during polymer flooding, as indicated by a significant decrease in water cut. Later, transmissibility contrasts are reinstated to replicate a water surge event observed in one of the producing wells during polymer flooding. This event may represent decreased injection conformance from fracture overextension; its anticipated occurrence in the other production well is included in the final forecast. The definition of polymer retention in the simulator incorporates the tailing effect reported in laboratory studies; this tailing effect is useful to the simultaneous history match of producing water cut and produced polymer concentration. The top 24 best-matched simulation models produced at each stage of the history matching process are used to forecast oil recovery. The final forecast clearly demonstrates that polymer flooding significantly increases the heavy oil production for this field pilot compared to waterflooding alone. This exercise displays that a simulation model is only valid for prediction if flow behavior in the reservoir remains consistent with that observed during the history matched period. Critically, this means that a simulation model calibrated for waterflooding may not fully capture the benefits of an enhanced oil recovery process such as polymer flooding. Therefore, caution is recommended in using basic waterflood simulation models to scope potential enhanced oil recovery projects.

Keith, Cody Douglas↗

A Model-Reference Adaptive Direct-Power Control Scheme for Grid-Interactive Inverters

This paper develops an adaptive direct power control scheme for grid-interactive inverters while the control parameters are adaptively adjusted as the grid and filter parameters vary under different conditions. To demonstrate the efficacy and robustness of the adaptive operation, the performance of the adaptive controller is compared with a typical direct power controller by estimating the filter and grid impedances using a model reference parameter estimation technique with small signal injection. The simulation results verify that the developed methodology can track the reference power setpoints under output circuit parameter uncertainties while the typical design leads to instability. To improve the performance of the adaptive technique and eliminate the need for filter parameter estimation, a Lyapunov stability criterion-based model-reference adaptive direct power controller is designed to track the filter impedance. The developed method was tested using MATLAB/Simulink software to demonstrate the effectiveness of the proposed method. The results verify that adaptively tuning the control parameter can still maintain stable operation if the control gains are poorly selected while applying the classical method leads to abnormal operation or instability.

Gursoy, Mehmetcan↗

Utah FORGE: Reports on Northwestern Nevada Well Doublet Drilling and Testing by Fervo Energy

These reports review Fervo Energy's construction of a commercial enhanced geothermal system (EGS). Fervo has qualified full functionality of the system through production testing at commercially relevant operating conditions. The project site is located in a nearfield setting adjacent to an operating geothermal power station in north-central Nevada and is designed to deliver an uplift in high-temperature geothermal flow rates to increase the power capacity at the facility. The project involved drilling a first-of-a-kind EGS horizontal doublet well system consisting of an injection and production well pair within a high-temperature hard-rock geothermal formation. The lithology of the target reservoir is characterized as a mixed metasedimentary and igneous formation, comprised of phyllite, quartzite, diorite, and granodiorite, representative of the geology across the most prospective geothermal areas throughout the western US. This work included a 16-stage plug-and-perforate stimulation treatment which was the first of its kind in a high-temperature mixed metasedimentary and granitic formation in a fully horizontal doublet geothermal well.

15 GEOTHERMAL ENERGY↗

Impact of the Exciter and Governor Parameters on Forced Oscillations

In recent years, the frequency of forced oscillation events due to control system malfunctions or improper parameter settings has increased. Tuning the parameters of exciters and governor models is crucial for maintaining power system stability. Traditional simulation studies typically involve small transient disturbances or step changes to find optimal parameter sets, but existing optimization algorithms often fall short in fine-tuning for forced oscillations. Identifying the sensitive parameters within these control models is essential for ensuring stability during large, sustained disturbances. This study focuses on identifying these critical exciter and governor model parameters by analyzing their influence on sustained forced oscillations. Using Kundur’s two-area system, we analyze common exciter models such as SCRX, ESST1A, and AC7B, along with governor models like GAST, HYGOV, and GGOV1, utilizing PSS®E software version 34. Sustained forced oscillations are injected at generator-1 of area-1, with individual parameter changes dynamically simulated. By considering a local oscillation frequency of 1.4 Hz and an inter-area oscillation mode of 0.25 Hz, we analyze the impact of each parameter change on the magnitude and frequency of forced oscillations as well as on active and reactive power outputs. This novel approach highlights the most influential parameters of each tested model—such as exciter, governor, and turbine gains, as well as time constant parameters—on the impact of forced oscillations. Based on our findings, the sensitive parameters of each tested model are ranked. These would provide valuable insights for industry operators to fine-tune control settings during oscillation events, ultimately enhancing system stability.