Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION EMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Active spectroscopic measurements of the bulk deuterium properties in the DIII-D tokamak (invited)

The neutral-beam induced D{sub {alpha}} emission spectrum contains a wealth of information such as deuterium ion temperature, toroidal rotation, density, beam emission intensity, beam neutral density, and local magnetic field strength magnitude Double-Vertical-Line B Double-Vertical-Line from the Stark-split beam emission spectrum, and fast-ion D{sub {alpha}} emission (FIDA) proportional to the beam-injected fast ion density. A comprehensive spectral fitting routine which accounts for all photoemission processes is employed for the spectral analysis. Interpretation of the measurements to determine physically relevant plasma parameters is assisted by the use of an optimized viewing geometry and forward modeling of the emission spectra using a Monte-Carlo 3D simulation code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular scattering of 1–50 keV ions through graphene and thin carbon foils: Potential applications for space plasma instrumentation

We present experimental results for the angular scattering of ∼1–50 keV H, He, C, O, N, Ne, and Ar ions transiting through graphene foils and compare them with scattering through nominal ∼0.5 μg cm{sup −2} carbon foils. Thin carbon foils play a critical role in time-of-flight ion mass spectrometers and energetic neutral atom sensors in space. These instruments take advantage of the charge exchange and secondary electron emission produced as ions or neutral atoms transit these foils. This interaction also produces angular scattering and energy straggling for the incident ion or neutral atom that acts to decrease the performance of a given instrument. Our results show that the angular scattering of ions through graphene is less pronounced than through the state-of-the-art 0.5 μg cm{sup −2} carbon foils used in space-based particle detectors. At energies less than 50 keV, the scattering angle half width at half maximum, ψ{sub 1/2}, for ∼3–5 atoms thick graphene is up to a factor of 3.5 smaller than for 0.5 μg cm{sup −2} (∼20 atoms thick) carbon foils. Thus, graphene foils have the potential to improve the performance of space-based plasma instruments for energies below ∼50 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of soft X-ray emission from Z-pinches with a complex atomic composition

Results are presented from experimental studies of Z-pinches produced by implosion of aluminum and tungsten cylindrical wire arrays in the Angara-5-1 facility. The electron temperature T{sub e} and density n{sub e} of the high-temperature pinch plasma have been determined by analyzing line emission from multicharged ions. For the same mass and radius of the array and the same number of wires in it, the intensity of line emission of H- and He-like Al ions from an imploded Al + W wire array containing even a small amount of tungsten (7 wt %) is one order of magnitude lower than that from an Al array. As the W content increases, the total soft X-ray (SXR) yield increases, while the duration of the SXR pulse decreases. For the 30% W content in the array, the power and duration of the SXR pulse are nearly the same as those recorded during the implosion of a W array with the same linear mass and radius and the same number of wires. Results are also presented from experiments with nested wire arrays in which the outer and inner shells were made of Al and W wires, respectively. It is found that, in this case, the effect of tungsten on the line emission of aluminum is much weaker than that in experiments with arrays in which tungsten and aluminum wires were placed in the same shell, even if the mass of the inner (tungsten) shell was larger than that of the outer (aluminum) one. At the same time, the inner W shell plays a significant role in the implosion dynamics of a nested wire array, reducing the duration of the SXR pulse and increasing the SXR power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

A Mg2+-Ge4+ substituting strategy for optimizing color rendering index and luminescence of YAG: Ce3+ phosphors for white LEDs

Highlights: • Mg{sup 2+}-Ge{sup 4+} ion pairs can partially substitute the Al{sup 3+} ions of YAG successfully. With the substitution, the garnet crystal structure remains unchanged. • With increasing Mg{sup 2+}-Ge{sup 4+} ions concentrations, the emission spectra show a progressive red-shift, from 528 to 552 nm (about 24 nm). • In white LEDs, with increasing Mg{sup 2+}-Ge{sup 4+} ions concentrations, the CCT decreased gradually from 6798 to 3261 K and the CRI increased from 76.5 to 89.3. - Abstract: Mg{sup 2+}-Ge{sup 4+} ions substituted YAG: Ce{sup 3+} phosphors (Y{sub 3}Al{sub 5-2x}Mg{sub x}Ge{sub x}O{sub 12}: Ce{sup 3+}) were prepared by high temperature solid state reaction method. X-ray diffraction (XRD), Scanning election microscope (SEM), Photoluminescence (PL) spectra and so on were used to characterize the samples. The effects of Mg{sup 2+}-Ge{sup 4+} concentrations on the morphology, structure, luminescence properties, fluorescence lifetime and white LED performance of YAG: Ce{sup 3+} phosphors were studied in detail. The results indicate that Mg{sup 2+}-Ge{sup 4+} ion pairs can partially substitute the Al{sup 3+} ions of YAG successfully. With the substitution, the garnet crystal structure remains unchanged. However the emission spectra show a progressive red-shift, from 528 to 552 nm (about 24 nm). The lifetime decreased rapidly from 84 to 26 ns. In particular, the correlated color temperature (CCT) decreases gradually from 6798 to 3261 K and the color rendering index (CRI) increases from 76.5 to 89.3 with the increasing of the incorporation content of Mg{sup 2+}-Ge{sup 4+} ion pairs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impurity trapped exciton states related to rare earth ions in crystals under high hydrostatic pressure

Emission related to rare earth ions in solids takes place usually due to 4f{sup n} {yields} 4f{sup n} and 4f{sup n-1}5d{sup 1} {yields} 4f{sup n} internal transitions. In the case of band to band excitation the effective energy transfer from the host to optically active impurity is required. Among other processes one of the possibilities is capturing of the electron at excited state and hole at the ground state of impurity. Localization of electron or hole at the dopand site creates a long range Coulomb potential that attracts the second carrier which then occupies the localized Rydberg-like states. Such a system can be considered as impurity trapped exciton. Usually impurity trapped exciton is a short living phenomenon which decays non-radiatively leaving the impurity ion in the excited state. However, in several compounds doped with Eu{sup 2+} the impurity trapped exciton states become stable and contribute to the radiative processes though anomalous luminescence that appears apart of the 4f{sup 7} {yields} 4f{sup 7} and 4f{sup 7}5d{sup 1} {yields} 5f{sup 7} emission. In this contribution pressure effect on energies of the 4f{sup n-1}5d{sup 1}{yields}5f{sup n} transitions in Ln doped oxides and fluorides as well as influence of pressure on the energy of impurity trapped exciton states is discussed. The latest results on high pressure investigations of luminescence related to Pr{sup 3+}, and Eu{sup 2+} in different lattices are reviewed.

36 MATERIALS SCIENCE↗

Surface charging and x-ray emission from insulator surfaces induced by collisions with highly charged ions : relevance to cometary and planetary sp

Characteristic X-ray emission lines are detected from simulants of comet surfaces as they undergo collisions with highly charged ions (HCIs). The HCI projectiles are O+2-O+7. Ion energies are varied in the range (2-7)q keV, where q is the ion charge state. The targets are the insulator minerals olivine, augite, and quartz. It is found that the emission of characteristic K-L, K-M X-rays appears to proceed during positive charging of the surface by the HCI beam. When one uses low-energy, flood-gun electrons to neutralize the surface charge, the X-ray emission is eliminated or greatly reduced, depending on the flood-gun current. Acceleration of background electrons onto the charged surface results in excitation of elemental transitions, including the K-L2 and K-L3 target X-ray emission lines of Mg and Si located spectroscopically at 1253.6 and 1739.4 eV, respectively. Also observed are emission lines from O, Na, Ca, Al, and Fe atoms in the target and charge-exchange lines via surface extraction of electrons by the O+q electric field. Good agreement is found in the ratio of the measured X-ray yields for Mg and Si relative to the ratio of their electron-impact K-shell ionization cross sections. The present study may serve as a guide to astronomers as to specific observing X-ray energies indicative of solar/stellar wind or magnetospheric ion interactions with a comet, planetary surface, or circumstellar dust.

comets↗

Enhanced electron amplifier structure and method of fabricating the enhanced electron amplifier structure

An enhanced electron amplifier structure includes a microporous substrate having a front surface and a rear surface, the microporous substrate including at least one channel extending substantially through the substrate between the front surface and the rear surface, an ion diffusion layer formed on a surface of the channel, the ion diffusion layer comprising a metal oxide, a resistive coating layer formed on the first ion diffusion layer, an emissive coating layer formed on the resistive coating layer, and an optional ion feedback layer formed on the front surface of the structure. The emissive coating produces a secondary electron emission responsive to an interaction with a particle received by the channel. The ion diffusion layer, the resistive coating layer, the emissive coating layer, and the ion feedback layer are independently deposited via chemical vapor deposition or atomic layer deposition.

Mane, Anil U.↗

First simultaneous measurement of the γ-ray and neutron emission probabilities in inverse kinematics at a heavy-ion storage ring

The probabilities for γ-ray and particle emission as a function of the excitation energy of a decaying nucleus are valuable observables for constraining the ingredients of the models that describe the deexcitation of nuclei near the particle emission threshold. These models are essential in nuclear astrophysics and applications. In this paper, we have for the first time simultaneously measured the γ-ray and neutron emission probabilities of 208 Pb. The measurement was performed in inverse kinematics at the Experimental Storage Ring (ESR) of the GSI/FAIR facility, where a 208 Pb beam interacted through the 208 Pb (p,p') reaction with a hydrogen gas jet target. Instead of detecting the γ rays and neutrons emitted by 208 Pb, we detected the heavy beamlike residues produced after γ and neutron emission. These heavy residues were fully separated by a dipole magnet of the ESR and were detected with outstanding efficiencies. The comparison of the measured probabilities with model calculations has allowed us to test and select different descriptions of the γ-ray strength function and the nuclear level density available in the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synthesis, crystal structures, magnetic and luminescent properties of unique 1D p-ferrocenylbenzoate-bridged lanthanide complexes

Treatments of p-ferrocenylbenzoate [p-NaOOCH{sub 4}C{sub 6}Fc, Fc=(eta{sup 5}-C{sub 5}H{sub 5})Fe(eta{sup 5}-C{sub 5}H{sub 4})] with Ln(NO{sub 3}){sub 3}.nH{sub 2}O afford seven p-ferrocenylbenzoate lanthanide complexes {l_brace}[Ln(OOCH{sub 4}C{sub 6}Fc){sub 2}(mu{sub 2}-OOCH{sub 4}C{sub 6}Fc){sub 2}(H{sub 2}O){sub 2}](H{sub 3}O){r_brace}{sub n} [Ln=Ce (1), Pr (2), Sm (3), Eu (4), Gd (5), Tb (6) and Dy (7)]. X-ray crystallographic analysis reveals that the isomorphous complexes {l_brace}[Ce(OOCH{sub 4}C{sub 6}Fc){sub 2}(mu{sub 2}-OOCH{sub 4}C{sub 6}Fc){sub 2}(H{sub 2}O){sub 2}](H{sub 3}O){r_brace}{sub n} (1) and {l_brace}[Pr(OOCH{sub 4}C{sub 6}Fc){sub 2}(mu{sub 2}-OOCH{sub 4}C{sub 6}Fc){sub 2}(H{sub 2}O){sub 2}](H{sub 3}O){r_brace}{sub n} (2) form a unique 1D double-bridged infinite chain structure bridged by mu{sub 2}-OOCH{sub 4}C{sub 6}Fc groups. Each Ln(III) ion adopts a dodecahedron coordination environment with eight coordinated oxygen atoms from two terminal monodentate coordinated FcC{sub 6}H{sub 4}COO{sup -} units, two terminal monodentate coordinated H{sub 2}O molecules and four mu{sub 2}-{sup -}OOCH{sub 4}C{sub 6}Fc units. The luminescent spectra reveal that only 4 and 6 exhibit characteristic emissions of lanthanide ions, Eu(III) and Tb(III) ions, respectively. The variable-temperature magnetic properties of 5 and 7 suggest that a ferromagnetic coupling between spin carriers may exist in 5. - Graphical abstract: Seven p-ferrocenylbenzoate lanthanide coordination polymers were synthesized. Given is the perspective view of a unique 1D double-bridged infinite chain structure of 1, excitation and emission spectra of 6 and plots of chi{sub m}T vs. T and chi{sub m}{sup -1} vs. T of 5.

36 MATERIALS SCIENCE↗

Charge exchange spectroscopy of multiply charged ions of industrial and astrophysical interest

Photon emission spectra have been measured in collisions of multiply charged ions with neutral target gases in keV collision energies. Extreme ultra-violet emission spectra of Xe and Sn ions have contributed to give the atomic data for the understanding of the light source plasmas for the next generation semiconductor lithography. And soft X-ray emission spectra of highly charged O ions have related to the solar wind charge exchange, and the results have been regarded as the useful data for the understanding the collisions of the solar wind ions with the neutral matter within the heliosphere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method of creating structure for particle detection in time projection chambers and photodetectors

Time projection chambers are useful for high energy particle physics, nuclear physics, and astronomy. To enhance the particle detection efficiency and performance of the projection chambers functional bilayer thin film coatings based on the atomic layer deposition method are utilized. Coating material selection is based on Auger neutralization process ion induced electron emission from metallic surfaces (e.g., Mo or W) combined with a high secondary electron emission coefficient. Application of high secondary electron emission materials (e.g., MgO and CaF2) enhances the multiplication of these emitted electrons from ion induction processes. Therefore, using suitable bilayer coatings the overall TPC signal detection efficiency can be increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical emission spectroscopy at the large RF driven negative ion test facility ELISE: Instrumental setup and first results

One of the main topics to be investigated at the recently launched large (A{sub source}= 1.0 × 0.9 m{sup 2}) ITER relevant RF driven negative ion test facility ELISE (Extraction from a Large Ion Source Experiment) is the connection between the homogeneity of the plasma parameters close to the extraction system and the homogeneity of the extracted negative hydrogen ion beam. While several diagnostics techniques are available for measuring the beam homogeneity, the plasma parameters are determined by optical emission spectroscopy (OES) solely. First OES measurements close to the extraction system show that without magnetic filter field the vertical profile of the plasma emission is more or less symmetric, with maxima of the emission representing the projection of the plasma generation volumes, and a distinct minimum in between. The profile changes with the strength of the magnetic filter field but under all circumstances the plasma emission in ELISE is much more homogeneous compared to the smaller IPP prototype sources. Planned after this successful demonstration of the ELISE OES system is to combine OES with tomography in order to determine locally resolved values for the plasma parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron density dependence of intensity ratio for FeXXII extreme ultraviolet emission lines arising from different ground levels in electron beam ion trap and large helical device

Extreme ultraviolet (EUV) spectra of highly charged iron ions in a wavelength range of 100-300 A have been observed from two different plasma sources of the Tokyo Electron Beam Ion Trap (Tokyo-EBIT) with a monoenergetic electron beam and a Large Helical Device (LHD) with Maxwellian electron energy. The excitation process of the spectral lines is compared between the two plasmas, and it is found that the excitation process for Fe XIX - Fe XXII ions is clearly different. Namely, the EUV emission lines from the EBIT plasma are only dominated by electron impact excitation connected to the ground state, but the excitation mechanism is not so simple in the LHD plasma. The difference in the excitation process is studied by measuring the intensity ratio of EUV emission lines (114.412 A [1s{sup 2}2s2p{sup 2} {sup 2}P{sub 3/2}{yields}1s{sup 2}2s{sup 2}2p {sup 2}P{sub 3/2}]/117.144 A [1s{sup 2}2s2p{sup 2} {sup 2}P{sub 1/2}{yields}1s{sup 2}2s{sup 2}2p {sup 2}P{sub 1/2}]) arising from different ground levels in the Fe XXII ions. The line intensity ratio has an extremely small value of 0.2 in the EBIT plasma with a low beam current of 30 mA and a beam energy of 2 keV, while the ratio varies with the electron density n{sub e} in the LHD plasmas, i.e., 0.35 for n{sub e} = 1 x 10{sup 13} cm{sup -3} and 0.65 for n{sub e} = 4 x 10{sup 13} cm{sup -3}. Here, the electron density of the EBIT plasma is estimated to be smaller than 10{sup 12} cm{sup -3} and the electron temperature of the LHD plasmas is 2 keV. The dependence of the line intensity ratio on the observed electron density is analyzed for both the EBIT and the LHD plasmas using several collisional-radiative (CR) models. The present experimental data can easily be reproduced by the analysis when the thermal proton impact excitation is taken into account. The importance of the proton impact excitation is also experimentally verified by injecting an iron pellet into the LHD plasmas and changing the ratio of the proton density to the electron density.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunable upconversion emission of Ho3+/Yb3+-doped single β-NaYF4 microrod

Highlights: • An intense red UC emission of Ho{sup 3+} ions was obtained in single NaYF{sub 4} microrod. • The UC emission of Ho{sup 3+} ions can be precisely turned via changing Ce{sup 3+} ion doped concentrations. • The UC mechanism and conversion efficiency were discussed. • The single NaYF{sub 4} microrod will have great potential applications in the laser. - Abstract: In this work, a series of hexagonal phase NaYF{sub 4}: Yb{sup 3+}/Ho{sup 3+} microrods have been successfully synthesized through hydrothermal methods, and their optical properties studied by a confocal microscope equipment with a 980 nm laser. An intense green and red upconversion emissions with candy-like emission pattern are observed from a single NaYF{sub 4}: Yb{sup 3+}/Ho{sup 3+} microrod. As the codoping Ce{sup 3+} ion concentrations increases from 0% to 12% in the microrods, the interesting phenomenon that fluorescence emission of Ho{sup 3+} ion is tuned green to red emission has been obtained. The red-to-green ratio emission of Ho{sup 3+} ions is enhanced about 11-fold, which is due to the two efficient cross-relaxation processes between Ho{sup 3+} and Ce{sup 3+} ions, which leading to the populations increase of the {sup 5}F{sub 5} state. The possible upconversion emission mechanisms are discussed based on the emission spectra of Ho{sup 3+} ions. The current study suggests that the NaYF{sub 4}: Yb{sup 3+}/Ho{sup 3+} microrods with the strong red upconversion emission may have great potential applications in micro-fiber laser, multicolor display, micro-optoelectronic device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evidence of transient species occurring in the reduction process of trivalent lanthanides under 2.5 MeV electron irradiation by in situ cathodoluminescence and time-resolved photoluminescence

In situ cathodoluminescence and time-resolved photoluminescence measurements were carried out on Sm-doped glasses during a 2.5 MeV electron irradiation. These experiments allow characterizing more precisely the mechanisms operating under irradiation and more specifically the reduction processes of Sm{sup 3+} to Sm{sup 2+} ions. Sm{sup 2+} emission lines appear in the first steps of the irradiation, however, the {sup 5}D{sub 0}->{sup 7}F{sub 0-2} emission lines of Sm{sup 2+} were not observed on the cathodoluminescence spectrum. Moreover, two sites of Sm{sup 2+} have been evidenced in the glasses; the formation of each species is clearly different. Relaxation processes of Sm{sup 3+} and Sm{sup 2+} leads to consider the existence of different transient states of Sm{sup 3+} and Sm{sup 2+} species which are annealed after irradiation. We propose some synthetic schemes of the reduction mechanisms produced during the irradiation.

36 MATERIALS SCIENCE↗

The ITER core imaging x-ray spectrometer: X-ray calorimeter performance

We describe the anticipated performance of an x-ray microcalorimeter instrument on ITER. As part of the core imaging x-ray spectrometer, the instrument will augment the imaging crystal spectrometers by providing a survey of the concentration of heavy ion plasma impurities in the core and possibly ion temperature values from the emission lines of different elemental ions located at various radial positions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗