Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Measurement-induced deterministic and probabilistic entanglement with strong and weak interactions

A scheme is proposed to transform spatial coherence of a single particle into entanglement. Two quantum systems can be entangled by having them interact in parallel with an ancillary particle in a Mach–Zehnder interferometer, then making a suitable post-selection of the particle followed by a conditional feedforward on one of the systems to be entangled. For a strong interaction between each system and the ancilla, the process works deterministically. For a weaker interaction only the probability of success is reduced, but the output continues to be a maximally entangled state. It is demonstrated that the process is optimal when the two interactions are symmetric, systems with continuous variables are considered, and the effects of the environment are taken into account. - Highlights: • Presents a scheme for deterministic entanglement based on feedforward, if a strong interaction is available. • Presents a scheme for probabilistic entanglement, if only a weak interaction is available. • Specifies the importance of an equal interaction strength in both arms. • Includes the effects of the environment and of the internal degrees of freedom of the ancilla.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of errors in the electron density measurements of a tangential interferometer/polarimeter system during a tokamak discharge

A new method for the comparative verification of electron density measurements obtained with a tangential interferometer and a polarimeter during a discharge is proposed. The possible errors associated with the interferometer and polarimeter are classified by the time required for their identification. Based on the characteristics of the errors, the fringe shift error of the interferometer and the low-frequency noise of the polarimeter were identified and corrected for the JT-60U tangential interferometer/polarimeter system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A PRACTICAL THEOREM ON USING INTERFEROMETRY TO MEASURE THE GLOBAL 21 cm SIGNAL

The sky-averaged, or global, background of redshifted 21 cm radiation is expected to be a rich source of information on cosmological reheating and reionization. However, measuring the signal is technically challenging: one must extract a small, frequency-dependent signal from under much brighter spectrally smooth foregrounds. Traditional approaches to study the global signal have used single antennas, which require one to calibrate out the frequency-dependent structure in the overall system gain (due to internal reflections, for example) as well as remove the noise bias from auto-correlating a single amplifier output. This has motivated proposals to measure the signal using cross-correlations in interferometric setups, where additional calibration techniques are available. In this paper we focus on the general principles driving the sensitivity of the interferometric setups to the global signal. We prove that this sensitivity is directly related to two characteristics of the setup: the cross-talk between readout channels (i.e., the signal picked up at one antenna when the other one is driven) and the correlated noise due to thermal fluctuations of lossy elements (e.g., absorbers or the ground) radiating into both channels. Thus in an interferometric setup, one cannot suppress cross-talk and correlated thermal noise without reducing sensitivity to the global signal by the same factor—instead, the challenge is to characterize these effects and their frequency dependence. We illustrate our general theorem by explicit calculations within toy setups consisting of two short-dipole antennas in free space and above a perfectly reflecting ground surface, as well as two well-separated identical lossless antennas arranged to achieve zero cross-talk.

79 ASTRONOMY AND ASTROPHYSICS↗

The Space Infrared Interferometric Telescope (SPIRIT): Optical System Design Considerations

SPIRIT is a candidate NASA Origins Probe mission. It is a spatial and spectral interferometer operating at 4 K with an operating wavelength range 25 - 400 microns. This paper describes the various components of the candidate optical system, including telescopes, pointing and tracking optics, along with their functions. Some of the tradeoffs involved in selecting various components, with their particular characteristics, are described.

Wilson, Mark E.↗

DOUBLE COMPACT OBJECTS AS LOW-FREQUENCY GRAVITATIONAL WAVE SOURCES

We study the Galactic field population of double compact objects (DCOs; NS-NS, BH-NS, BH-BH binaries) to investigate the number (if any) of these systems that can potentially be detected with the Laser Interferometer Space Antenna (LISA) at low gravitational wave frequencies. We calculate the Galactic numbers and physical properties of these binaries and show their relative contributions from the disk, bulge, and halo. Although the Galaxy hosts {approx}10{sup 5} DCO binaries emitting low-frequency gravitational waves, only a handful of these objects in the disk will be detectable with LISA, but none from the halo or bulge. This is because the bulk of these binaries are NS-NS systems with high eccentricities and long orbital periods (weeks/months) causing inefficient signal accumulation (a small number of signal bursts at periastron passage in one year of LISA observations) and rendering them undetectable in the majority of these cases. We adopt two evolutionary models that differ in their treatment of the common envelope (CE) phase that is a major (and still mostly unknown) process in the formation of close DCOs. Depending on the evolutionary model adopted, our calculations indicate the likely detection of about four NS-NS binaries and two BH-BH systems (model A; likely survival of progenitors through CE) or only a couple of NS-NS binaries (model B; suppression of the DCO formation due to CE mergers).

79 ASTRONOMY AND ASTROPHYSICS↗

Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices

Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.

Instruments & Instrumentation↗

Formations of Tethered Spacecraft as Stable Platforms for Far IR and Sub-mm Astronomy

In this paper we describe current research in tethered formations for interferometry, and a roadmap to demonstrating the required key technologies via on-ground and in-orbit testing. We propose an integrated kilometer-size tethered spacecraft formation flying concept which enables Far IR and Sub-mm astronomy observations from space. A rather general model is used to predict the dynamics, control, and estimation performance of formations of spacecraft connected by tethers in LEO and deep space. These models include the orbital and tethered formation dynamics, environmental models, and models of the formation estimator/controller/commander. Both centralized and decentralized control/sensing/estimation schemes are possible, and dynamic ranges of interest for sensing/control are described. Key component/subsystem technologies are described which need both ground-based and in-orbit demonstration prior to their utilization in precision space interferometry missions using tethered formations. Defining an orbiting formation as an ensemble of orbiting spacecraft performing a cooperative task, recent work has demonstrated the validity of the tethering the spacecraft to provide both the required formation rigidity and satisfy the formation reconfiguration needs such as interferometer baseline control. In our concept, several vehicles are connected and move along the tether, so that to reposition them the connecting tether links must vary in length. This feature enables variable and precise baseline control while the system spins around the boresight. The control architecture features an interferometer configuration composed of one central combiner spacecraft and two aligned collector spacecraft. The combiner spacecraft acts as the formation leader and is also where the centralized sensing and estimation functions reside. Some of the issues analyzed with the model are: dynamic modes of deformation of the distributed structure, architecture of the formation sensor, and sources of dynamical perturbation that need to be mitigated for precision operation in space. Examples from numerical simulation of an envisioned scenario in heliocentric orbit demonstrate the potential of the concept for space interferometry.

Quadrelli, Marco B.↗

Stitching interferometry for ellipsoidal x-ray mirrors

Ellipsoidal mirrors, which can efficiently produce a two-dimensional focusing beam with a single mirror, are superior x-ray focusing optics, especially when compared to elliptical-cylinder mirrors in the Kirkpatrick–Baez geometry. However, nano-focusing ellipsoidal mirrors are not commonly used for x-ray optics because achieving the accuracy required for the surface metrology of nano-focusing ellipsoidal mirrors is difficult due to their small radius of curvature along the short ellipsoidal axis. Here, we developed a surface metrology system for nano-focusing ellipsoidal mirrors using stitching interferometric techniques. The developed system simultaneously measures sub-aperture shapes with a microscopic interferometer and the tilt angles of the sub-aperture shapes with a large Fizeau interferometer. After correcting the systematic errors included in the sub-aperture shapes, the entire mirror shape is calculated by stitching the sub-aperture shapes based on the obtained relative angles between partially overlapped sub-apertures. In this study, we developed correction methods for systematic errors in sub-aperture shapes that originated from off-axis aberrations produced in the optics of the microscopic interferometer. The systematic errors on an ellipsoidal mirror were estimated by measuring a series of tilted plane substrates and the ellipsoidal substrate. From measurements of an ellipsoidal mirror with a 3.6-mm radius of curvature at the mirror center, we obtained a measurement repeatability of 0.51 nm (root-mean-square) in an assessment area of 0.5 mm × 99.18 mm. This value satisfies the requirements for surface metrology of nano-focusing x-ray mirrors. Thus, the developed metrology system should be applicable for fabricating nano-focusing ellipsoidal mirrors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Sensitivities of Gravitational Wave Detectors Based on Atom Interferometers and Light Interferometers

We consider a class of proposed gravitational wave detectors based on multiple atomic interferometers separated by large baselines and referenced by common laser systems. We compute the sensitivity limits of these detectors due to intrinsic phase noise of the light sources, non-inertial motion of the light sources, and atomic shot noise and compare them to sensitivity limits for traditional light interferometers. We find that atom interferometers and light interferometers are limited in a nearly identical way by intrinsic phase noise and that both require similar mitigation strategies (e.g. multiple arm instruments) to reach interesting sensitivities. The sensitivity limit from motion of the light sources is slightly different and favors the atom interferometers in the low-frequency limit, although the limit in both cases is severe. Whether this potential advantage outweighs the additional complexity associated with including atom interferometers will require further study.

Baker, John G.↗

Comparison of Atom Interferometers and Light Interferometers as Space-Based Gravitational Wave Detectors

We consider a class of proposed gravitational wave detectors based on multiple atomic interferometers separated by large baselines and referenced by common laser systems. We compute the sensitivity limits of these detectors due to intrinsic phase noise of the light sources, non-inertial motion of the light sources, and atomic shot noise and compare them to sensitivity limits for traditional light interferometers. We find that atom interferometers and light interferometers are limited in a nearly identical way by intrinsic phase noise and that both require similar mitigation strategies (e.g. multiple arm instruments) to reach interesting sensitivities. The sensitivity limit from motion of the light sources is slightly different and favors the atom interferometers in the low-frequency limit, although the limit in both cases is severe.

Baker, John G.↗

Interferometers adaptations to lidars

To perform daytime measurements of the density and temperature by Rayleigh lidar, it is necessary to select the wavelength with a very narrow spectral system. This filter is composed by an interference filter and a Fabry Perot etalon. The Fabry Perot etalon is the more performent compound, and it is necessary to build a specific optic around it. The image of the entrance pupil or the field diaphragm is at the infinite and the other diaphragm is on the etalon. The optical quality of the optical system is linked to the spectral resolution of the system to optimize the reduction of the field of view. The resolution is given by the formula: R = 8(xD/Fd)exp 2 where R = lambda/delta(lambda), x = diameter of the field diaphragm, D = diameter of the reception mirror, F = focal length of the telescope, and d = useful diameter of the etalon. In the Doppler Rayleigh lidars, the PF interferometer is the main part of the experiment and the exact spectral adaptation is the most critical problem. In the spectral adaptation of interferometers, the transmittance of the system will be acceptable if the etalon is exactly adjusted to the wavelength of the laser. It is necessary to work with a monomode laser, and adjust the shift to the bandpass of the interferometer. We are working with an interferometer built with molecular optical contact. This interferometer is put in a special pressure closed chamber.

Porteneuve, J.↗

Entanglement estimation in non-optimal qubit states

Highlights: • Quantum Fisher Information. • Entanglement Estimation. • Squeezed States. • Husimi Function. - Abstract: In the last years, a relationship has been established between the quantum Fisher information (QFI) and quantum entanglement. In the case of two-qubit systems, all pure entangled states can be made useful for sub-shot-noise interferometry while their QFI meets a necessary and sufficient condition (Hyllus et al., 2010). In M-qubit systems, the QFI provides just a sufficient condition in the task of detecting the degree of entanglement of a generic state (Pezzé and Smerzi, 2009). In our work, we show analytically that, for a large class of one-parameter non-optimal two-qubit states, the maximally entangled states are associated with stationary points of the QFI, as a function of such parameter. We show, via numerical simulations, that this scenario is maintained for the generalisation of this class of states to a generic M-qubit system. Furthermore, we suggest a scheme for an interferometer able to detect the entanglement in a large class of two-spin states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A laser interferometer for measuring straightness and its position based on heterodyne interferometry

Not only the magnitude but also the position of straightness errors are of concern to users. However, current laser interferometers used for measuring straightness seldom give the relative position of the straightness error. To solve this problem, a laser interferometer for measuring straightness and its position based on heterodyne interferometry is proposed. The optical configuration of the interferometer is designed and the measurement principle is analyzed theoretically. Two experiments were carried out. The first experiment verifies the validity and repeatability of the interferometer by measuring a linear stage. Also, the second one for measuring a flexure-hinge stage demonstrates that the interferometer is capable of nanometer measurement accuracy. These results show that this interferometer has advantages of simultaneously measuring straightness error and the relative position with high precision, and a compact structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Area-selected Ion Milling for Reflection Wavefront Error Correction of Soft X-ray Multilayer Mirrors

For accurate reflection wavefront error correction of imaging soft X-ray multilayer mirrors, a period-by-period ion milling system was developed. A stable and homogenized radial distribution of ion beam was realized for an ion milling over a whole area of 100 mm-wide multilayer. To demonstrate the wavefront error correction principle, a dielectric multilayer mirror for visible light was locally milled by our system. Wavefront as measured by a phase shifting interferometer showed the reflection phase of local milling multilayer advanced. Area-selected ion millings with mask templates made of Mo and Si, and by photoresist contact masks were carried out. Although striped patterns generated by the difference of spectroscopic reflectance between Mo and Si were observed at peripherals of milling area when templates were used, a clear and sharp edge pattern was obtained with contact mask. Soft X-ray reflectance of a Mo/Si multilayer milled with photoresist contact mask showed good feasibility of precise wavefront error correction of multilayers. These results proved our phase correction method is promising and practical for the 0.1 nm-period correction of soft X-ray multilayer mirror.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: Digital laser frequency auto-locking for inter-satellite laser ranging

We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A very high frequency radio interferometer for investigating ionospheric disturbances using geostationary satellites. Determination of changes in exospheric electron content by a comparison of group delay and Faraday rotation

The theory and development of a VHF correlation radio interferometer for investigating ionospheric disturbances are discussed. The system was developed to receive signals from the geostationary Applications Technology Satellites. Amplitude and phase variations of the signal passing through the ionosphere can be detected by this instrument. The system consists of two superheterodyne receivers separated by a distance known as the baseline of the system. Since the system is a phase sensitive instrument, the local oscillators of the two receivers must be phase coherent. This is accomplished by using phase-locked loops for generating the local oscillators. The two signals from the separate receivers are cross-correlated by multiplying the two signals together and then time averaging the result. The sensitivity of the instrument is increased by off-setting one of the local oscillators by a small amount.

Terry, R.↗

The Nimbus 4 data catalog. Volume 8: Data orbits 5206-10,120, 1 May 1971 - 30 April 1972

Data from various instruments onboard the Nimbus 4 are presented, including the image dissector camera system, the temperature-humidity infrared radiometer, infrared interferometer spectrometer, and monitor of ultraviolet solar energy experiments. This data was collected from 1 May 1971 to 30 Apr. 1972. Orbital elements and daily sensor data are presented in tabular form.

Source record↗