Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPACT LOAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Empirical Analysis of the Variability of Wind Generation in India: Implications for Grid Integration

We analyze variability in load and wind generation in India to assess its implications for grid integration of large scale wind projects using actual wind generation and load data from two states in India, Karnataka and Tamil Nadu. We compare the largest variations in load and net load (load -wind, i.e., load after integrating wind) that the generation fleet has to meet. In Tamil Nadu, where wind capacity is about 53% of the peak demand, we find that the additional variation added due to wind over the current variation in load is modest; if wind penetration reaches 15% and 30% by energy, the additional hourly variation is less than 0.5% and 4.5% of the peak demand respectively for 99percent of the time. For wind penetration of 15% by energy, Tamil Nadu system is found to be capable of meeting the additional ramping requirement for 98.8percent of the time. Potential higher uncertainty in net load compared to load is found to have limited impact on ramping capability requirements of the system if coal plants can me ramped down to 50percent of their capacity. Load and wind aggregation in Tamil Nadu and Karnataka is found to lower the variation by at least 20% indicating the benefits geographic diversification. These findings suggest modest additional flexible capacity requirements and costs for absorbing variation in wind power and indicate that the potential capacity support (if wind does not generate enough during peak periods) may be the issue that has more bearing on the economics of integrating wind

17 WIND ENERGY↗

Dual-Bed Radioiodine Capture from Complex Gas Streams with Zeolites: Regeneration and Reuse of Primary Sorbent Beds for Sustainable Waste Management

Dual-sorbent systems are proposed for radioiodine management with a regenerated primary bed for multiple cycles of use in complex conditions and a secondary bed for disposal with higher waste loadings. Sorbent approaches for the effective capture of gaseous radioiodine (isotopes 129 I and 131 I) produced from a range of nuclear processes have been studied for over half a century. (1−5) Whether or not a sorbent (e.g., molecular sieve) is required to physically screen/trap or chemically bind a radionuclide of interest through chemisorption, the complexity of the gas stream has a large impact on the performance (e.g., loading capacity, selectivity) and active life of a sorbent bed. (3) Silver mordenite (AgZ), the U.S. Department of Energy baseline sorbent for radioiodine capture from nuclear processes, performs well within acidic conditions and at elevated temperatures (6) and can be consolidated into a chemically durable waste form for long-term disposal. (7,8) However, new sorbents are being sought because optimal capture performance of AgZ significantly decreases in dynamic oxidizing environments with competing species, and it is expensive and it contains Ag (a toxic metal). (9) Until a new sorbent is found to replace AgZ, the regeneration and reuse of AgZ is an attractive alternative to a single-use primary sorbent bed. In this regard, a primary sorbent could be designed for enhanced capture in complex gas streams and the ability to be regenerated for reuse. Here, a secondary sorbent could then be tailored for maximum iodine loading in the gas stream and chemical durability within a disposal facility.

chemisorption↗

Diesel Particulate Filter Durability Performance Comparison Using Metals Doped B20 vs. Conventional Diesel Part I: Accelerated Ash Loading and DPF Performance Evaluation

The project objective was to generate experimental data to evaluate the impact of metals doped B20 on DPF ash loading and performance compared to that of conventional petrodiesel. Accelerated ash loading was conducted on two DPFs - one exposed to regular diesel fuel and the other to B20 containing metal dopants equivalent to 4 ppm B100 total metals (currently total metals are limited to 10 ppm in ASTM D6751, the standard for B100). Periodic performance evaluations were conducted on the DPFs at 10 g/L ash loading intervals. After the evaluations at 30 g/L, the DPF was cleaned with a commercial DPF cleaning machine and another round of DPF evaluations were conducted. A comparison of the effect of ash loading with the two fuels and DPF cleaning is presented. The metals doped B20 fuel resulted in ash that was similar to that deposited when exposed to ULSD (lube oil ash) and exhibited similar ash cleaning removal efficiency. Metals doped B20 resulted in faster ash accumulation within the DPF, as expected, but did not appear to have a negative effect on DPF pressure drop or regeneration rates (up to 30 g/L of ash) or exhibit deleterious physical effects on the DPF substrate.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Assessing Impact of Reactor Scaling on Carbohydrate and Lipid Yields from Saline and Fresh Water Algae

Effective deconstruction of algal biomass is a major challenge associated with algal biofuels/bioproduct production. Improving biomass conversion requires understanding how reaction parameters affect the scale-up of bench scale processes to move to cost-effective conversion. Pretreatment of both aquatic and terrestrial feedstocks, using similar reaction conditions, identical feedstock and pretreatment chemistries have reported wide ranges in total sugar yields. This has been attributed to differences in reactor size or scale, type of operation (batch vs continuous), method of heating, reactor geometry and solids loading (w/w). These factors can impact both mass and heat transfer affecting both yield and reaction kinetics. To understand how total sugar yields in algal biomass are affected by different dilute acid pretreatment configurations we evaluated total sugar and lipid release at three reactor scales ranging from 4 ml to 300 ml, operated under mixed and non-mixed regimes.

09 BIOMASS FUELS↗

Data for Natural Deep Eutectic Solvents (NADES) Assisted Deconstruction of Oilcane Bagasse for High Lipid and Sugar Recovery

In a novel approach, metabolically engineered sugarcane “Oilcane” has been investigated for fractionation of lipid and cellulose-rich pulp, using certain Natural deep eutectic solvents (NADES). The exploration of eco-friendly solvents are at the forefront of harnessing the biofuel potential of modern bioenergy crops. For this, six combinations of NADES were prepared using choline chloride (ChCl) as HBA and lactic acid (LA), oxalic acid (OA) and glycerol (Gly) as HBD and were further explored for pretreatment of oilcane bagasse in a molar ratio of 1:1 and 1:2. The impact of NADES ratio, biomass loading (10–50%), residence time (1–2 h), and temperature (90–140 °C) were evaluated for delignification, lipid content, sugar release after enzymatic hydrolysis. The finding demonstrated that under the optimal condition of ChCl: LA (1:2 molar ratio), 140 °C with 2 h retention time, the lipid content in the pre-treated substrate was increased to 2.5-fold (∼8% w/w) and > 80% glucose yield was achieved after 72 h of hydrolysis of pre-treated bagasse. High solid loading (∼50%) during pretreatment resulted in a similar glucose yield. Furthermore, recycling studies demonstrated that nearly 95 to 98% NADES could be recycled after each pretreatment for up to five consecutive cycles without any significant loss in chemical structure as confirmed by 1H NMR and FT IR. FT IR and XRD analyses of native and pre-treated biomass were performed to visualize the morphological changes during NADES pretreatment and their impact on sugar yield. The findings of the study may be used to establish NADES-based biorefinery for the valorization of lipids, and carbohydrates for fuels and chemicals production.

Conversion↗

Natural deep eutectic solvents (NADES) assisted deconstruction of oilcane bagasse for high lipid and sugar recovery

In a novel approach, metabolically engineered sugarcane “Oilcane” has been investigated for fractionation of lipid and cellulose-rich pulp, using certain Natural deep eutectic solvents (NADES). The exploration of eco- friendly solvents are at the forefront of harnessing the biofuel potential of modern bioenergy crops. For this, six combinations of NADES were prepared using choline chloride (ChCl) as HBA and lactic acid (LA), oxalic acid (OA) and glycerol (Gly) as HBD and were further explored for pretreatment of oilcane bagasse in a molar ratio of 1:1 and 1:2. The impact of NADES ratio, biomass loading (10–50%), residence time (1–2 h), and temperature (90–140 °C) were evaluated for delignification, lipid content, sugar release after enzymatic hydrolysis. The finding demonstrated that under the optimal condition of ChCl: LA (1:2 molar ratio), 140 °C with 2 h retention time, the lipid content in the pre-treated substrate was increased to 2.5-fold (~8% w/w) and > 80% glucose yield was achieved after 72 h of hydrolysis of pre-treated bagasse. High solid loading (~50%) during pretreatment resulted in a similar glucose yield. Furthermore, recycling studies demonstrated that nearly 95 to 98% NADES could be recycled after each pretreatment for up to five consecutive cycles without any significant loss in chemical structure as confirmed by 1 H NMR and FT IR. FT IR and XRD analyses of native and pre-treated biomass were performed to visualize the morphological changes during NADES pretreatment and their impact on sugar yield. The findings of the study may be used to establish NADES-based biorefinery for the valorization of lipids, and carbohydrates for fuels and chemicals production.

09 BIOMASS FUELS↗

Improved inertial control for permanent magnet synchronous generator wind turbine generators

With increasing integrations of large‐scale systems based on permanent magnet synchronous generator wind turbine generators (PMSG‐WTGs), the overall inertial response of a power system will tend to deteriorate as a result of the decoupling of rotor speed and grid frequency through the power converter as well as the scheduled retirement of conventional synchronous generators. Thus, PMSG‐WTGs can provide value to an electric grid by contributing to the system's inertial response through the inherent kinetic energy stored in their rotating masses and fast power converter control. In this study, an improved inertial control method based on the maximum power point tracking operation curve is introduced to enhance the overall frequency support capability of PMSG‐WTGs in the case of large supply–demand imbalances. Moreover, this method is implemented in the CART2‐PMSG integrated model in MATLAB/Simulink to investigate its impact on the wind turbine's structural loads during the inertial response process. Simulation results indicate that the proposed method can effectively reduce the frequency nadir, arrest the rate of change of frequency, and alleviate the secondary frequency dip while imposing no negative impact on the major mechanical components of the wind turbine.

Wu, Ziping↗

Frequency Support of PMSG-WTG Based on Improved Inertial Control

With increasing integrations of large-scale systems based on permanent magnet synchronous generator wind turbine generators (PMSG-WTGs), the overall inertial response of a power system will tend to deteriorate as a result of the decoupling of rotor speed and grid frequency through the power converter as well as the scheduled retirement of conventional synchronous generators. Thus, PMSG-WTGs can provide value to an electric grid by contributing to the system's inertial response by utilizing the inherent kinetic energy stored in their rotating masses and fast power control. In this work, an improved inertial control method based on the maximum power point tracking operation curve is introduced to enhance the overall frequency support capability of PMSG-WTGs in the case of large supply-demand imbalances. Moreover, this method is implemented in the CART2-PMSG integrated model in MATLAB/Simulink to investigate its impact on the wind turbine's structural loads during the inertial response process. Simulation results indicate that the proposed method can effectively reduce the frequency nadir, arrest the rate of change of frequency, and mitigate the secondary frequency drop while imposing no negative impact on the major mechanical components of the wind turbine.

17 WIND ENERGY↗

Variables Influenced by Thermal Mass and its Impact on Energy Performance in Buildings

There is no question that thermal mass has an impact on the energy performance of buildings, both the peak energy demand and overall consumption. However, there are many variables that contribute to and influence the impact of mass on energy performance. This paper is the result of an analytic study that evaluated thermal mass and associated building envelope energy performance for commercial and residential prototype buildings. Relationships between thermal mass, insulation levels, internal gains, outdoor climate, building usage and user preferences were studied. In this paper, authors analyzed how these variables interact and investigated optimized conditions for utilization of thermal mass. It is also discussed how air conditioning operation, exterior and interior loads, and thermostat set points impact the usefulness of thermal mass in a building to favorably impact peak demand and energy savings. Existing methods and approaches to evaluate the impact of thermal mass are discussed and a preferred design approach is presented to estimate the impact of thermal mass on energy peak demand and overall energy consumption under both heating and cooling conditions.

Pallin, Simon B.↗

On the Impact of Execution Models: A Case Study in Computational Chemistry

Efficient utilization of high-performance computing (HPC) platforms is an important and complex problem. Execution models, abstract descriptions of the dynamic runtime behavior of the execution stack, have significant impact on the utilization of HPC systems. Using a computational chemistry kernel as a case study and a wide variety of execution models combined with load balancing techniques, we explore the impact of execution models on the utilization of an HPC system. We demonstrate a 50 percent improvement in performance by using work stealing relative to a more traditional static scheduling approach. We also use a novel semi-matching technique for load balancing that has comparable performance to a traditional hypergraph-based partitioning implementation, which is computationally expensive. Using this study, we found that execution model design choices and assumptions can limit critical optimizations such as global, dynamic load balancing and finding the correct balance between available work units and different system and runtime overheads. With the emergence of multi- and many-core architectures and the consequent growth in the complexity of HPC platforms, we believe that these lessons will be beneficial to researchers tuning diverse applications on modern HPC platforms, especially on emerging dynamic platforms with energy-induced performance variability.

Execution models, computational chemistry, MPI and↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a plug-and-play anti-noise module for fault diagnosis of rotating machines in nuclear power plants

The health of rotating machines is crucial to the stable operation and safety of nuclear power plants. However, research on machine learning-based fault diagnosis of rotating machines in the nuclear industry is still in its infancy. The signal noise generated in the plant may negatively affect the effectiveness of the analysis. In this paper, a plug-and-play anti-noise machine learning module is proposed to fill the knowledge and capability gap. The modules are loaded into a convolutional neural network called deep residual network (ResNet) to obtain a new model with noise reduction capability. The basic idea is that the module is able to identify noise features and include them in the subsequent analysis, effectively filtering noise at the feature level of the network. Nine variants of the new model are compared with the original ResNet as well as four classical machine learning models to test the effectiveness of the module and to examine the impact of the module's loading modes on the performance of the new model. Finally, this research helps facilitate the application of machine learning in the plant noise environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessing Geospatial and Seasonal Influences on Energy and Cost-Efficiency of Drayage Trucks

The electrification of heavy-duty vehicles is a critical pathway toward improved energy efficiency in the freight sector. The current battery electric truck technology poses several challenges to commercial vehicle operations, such as limited driving range, sensitivity to climate conditions, and long recharging times. Estimating the energy consumption of heavy-duty electric trucks is crucial to assessing the feasibility of fleet electrification and its impact on the electric grid. This article focuses on developing a model-based simulation approach to predict and analyze the energy consumption of electric trucks by considering the impact of weather and geographical conditions on vehicle road load and auxiliary components power consumption, as well as the impact these factors have on driving range. Specifically, drayage trucks employed in logistics around maritime ports are used as a case study, with consideration of seasonal climate variations and geographical characteristics at different locations. The article includes results for three major container ports within the United States, providing region-specific insights into the energy requirements and driving range of the electric drayage trucks in these regions, which will inform decision-makers in integrating electric trucks into the existing drayage operations and plan investments for electric grid development.

Sujan, Vivek [ORNL] (ORCID:0000000269882342)↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

A Technical-Economic Assessment of Brackish Water Treatment for Fossil Power Plant Cooling with Reduced Environmental Impact

The power sector accounts for approximately 40% of freshwater use in the U.S. Reusing non-traditional water resources is critical for alleviating water stress in the western United States. The purpose of this study is to conduct a techno-economic system analysis to evaluate the potential of brackish water treatment for wet cooling towers at existing thermo-electric generating units (EGUs). It aims to address current knowledge gaps in support of non-traditional water resources planning and the electric power industry's water decision- and policy making. An engineering-economic model was developed and combined with DuPont's water application value engine (WAVE) v1.82 to evaluate the viability of retrofitting reverse osmosis-based brackish water treatment systems to individual existing EGUs and then aggregating the unit-level results to the fleet level. In the base case, brackish water treatment can reduce freshwater consumption of electric generation units by 94–100% while increasing the cost of electric generation by approximately 10% and have marginal impacts on the units' parasitic loads. When zero liquid discharge systems are applied to brackish water brine treatment, the cost of electric generation and freshwater consumption savings and energy penalty to the power plant significantly increase. These costs are even higher than dry cooling deployment in lieu of wet cooling towers. The choice of freshwater savings between brackish water desalination and dry cooling deployment depends greatly on how the concentrated brines are managed. Multiple factors must be considered when supporting decision-making in water management and planning in power sectors, which include non-traditional water quantity and quality as well as trade-offs among technical performance, economics, and environmental impacts.

Wu, Zitao↗

Impact Testing of Stainless Steel Material at Cold Temperatures

Stainless steels are used for the construction of numerous spent nuclear fuel or radioactive material containers that may be subjected to high strains and moderate strain rates during accidental drop events. Mechanical characteristics of these base materials and their welds under dynamic loads in the strain rate range of concern are not well documented. However, a previous paper [1] reported on impact testing and analysis results performed at the Idaho National Laboratory using 304/304L and 316/316L stainless steel base material specimens at room and elevated temperatures. The goal of the work presented herein is to add recently completed impact tensile testing results at -20 degrees F conditions for dual-marked 304/304L and 316/316L stainless steel material specimens (hereafter referred to as 304L and 316L, respectively). Recently completed welded material impact testing at -20 degrees F, room, 300 degrees F, and 600 degrees F is also reported. Utilizing a drop-weight impact test machine and 1/4-inch to 1/2-inch thick dog-bone shaped test specimens, the impact tests achieved strain rates in the 4 to 40 per second range, depending upon the material temperature. Elevated true stress-strain curves for these materials reflecting varying strain rates and temperatures are presented herein.

42 ENGINEERING↗

Design and Implementation of a Thermal Load Reduction System for a Hyundai Sonata PHEV for Improved Range

Increased adoption of electric-drive vehicles requires overcoming hurdles including limited vehicle range. Vehicle cabin heating and cooling demand for occupant climate control requires energy from the main battery and has been shown to significantly degrade vehicle range. During peak cooling and heating conditions, climate control can require as much as or more energy than propulsion. As part of an ongoing project, the National Renewable Energy Laboratory and project partners Hyundai America Technical Center, Inc., Gentherm, Pittsburgh Glass Works, PPG Industries, Sekisui, 3 M, and Hanon Systems developed a thermal load reduction system to reduce the range penalty associated with electric vehicle climate control. Solar reflective paint, solar control glass, heated and cooled/ventilated seats, heated surfaces, and a heated windshield with door demisters were integrated into a Hyundai Sonata plug-in hybrid electric vehicle. Cold weather field-testing was conducted in Fairbanks, Alaska, and warm weather testing was conducted in Death Valley, California, to assess the system performance in comparison to the baseline production vehicle. In addition, environmental chamber testing at peak heating and cooling conditions was performed to assess the performance of the system in standardized conditions compared to the baseline. Experimental results are presented in this paper, providing quantitative data to automobile manufacturers on the impact of climate control thermal load reduction technologies to increase the advanced thermal technology adoption and market penetration of electric drive vehicles.

33 ADVANCED PROPULSION SYSTEMS↗