Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Overview of the SPring-8 Diagnostics Beamlines

We present an overview of the two SPring-8 diagnostics beamlines, the beamline I (dipole magnet source) and II (insertion device source). At the beamline I, synchrotron radiation (SR) in both the X-ray and the visible bands is exploited for characterizations of the electron beam. At the beamline II, by observing the spectral, spatial, and temporal characteristics of X-ray SR of the insertion device (ID), new techniques for accelerator diagnostics are investigated. Irradiation experiments with the ID to develop accelerator components such as photon absorbers, and production of intensive 10 MeV {gamma}-rays by backward Compton scattering of external far infrared (FIR) laser photons are being prepared at the beamline II.

43 PARTICLE ACCELERATORS↗

An in-vacuum wiggler for SOLEIL Hard X-rays spectral range

The production of Hard X-rays has become a tricky problem on medium energy storage rings. It requires Insertion Devices (IDs) with high magnetic field and a large number of periods. To cover the 20-50 keV photon energy range at SOLEIL (2.75 GeV), an in-vacuum wiggler (WSV50) has been preferred to a superconducting ID. The wiggler is composed of 38 periods of 50 mm producing a 2.1 T field at a minimum magnetic gap of 5.5 mm. To minimize the magnetic forces acting between magnet arrays (8.5 tons), a compensation system composed of non magnetic springs has been mounted apart from the magnet system to reduce the mechanical deformations. The wiggler has been assembled step by step by means of a genetic algorithm which minimizes the magnetic errors measured with a flipping coil. This paper presents the mechanical and magnetic design of the wiggler as well as the construction and the magnetic measurements.

43 PARTICLE ACCELERATORS↗

Eddy current signal comparison for tube identification

Inspection of nuclear power plant steam generator tubes is required to justify continued safe plant operation. The steam generators consist of thousands of tubes with nominal diameters of 15 to 22mm, approximately 1mm wall thickness, and 20 to 30m in length. The tubes are inspected by passing an eddy current probe through the tubes from tube end to tube end. It is critical to know exactly which tube identification (row and column) is associated with each tube's data. This is controlled by a precision manipulator that provides the tube ID to the eddy current system. Historically there have been some instances where the manipulator incorrectly reported the tube ID. This can have serious consequences including lack of inspection of a tube, or if a pluggable indication is detected, the tube is likely to be mis-plugged thereby risking a primary to secondary leak.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New developments in high pressure x-ray spectroscopy beamline at High Pressure Collaborative Access Team

The 16 ID-D (Insertion Device - D station) beamline of the High Pressure Collaborative Access Team at the Advanced Photon Source is dedicated to high pressure research using X-ray spectroscopy techniques typically integrated with diamond anvil cells. The beamline provides X-rays of 4.5-37 keV, and current available techniques include X-ray emission spectroscopy, inelastic X-ray scattering, and nuclear resonant scattering. Here, the recent developments include a canted undulator upgrade, 17-element analyzer array for inelastic X-ray scattering, and an emission spectrometer using a polycapillary half-lens. Recent development projects and future prospects are also discussed.

47 OTHER INSTRUMENTATION↗

Production of carbon nanotubes: Chemical vapor deposition synthesis from liquefied petroleum gas over Fe-Co-Mo tri-metallic catalyst supported on MgO

Carbon nanotubes were produced by chemical vapor deposition method to meet the specifications for hydrogen storage. So far, the various catalyst had been studied outlining their activities, performances, and efficiencies. In this work, tri-metallic catalyst consist of Fe-Co-Mo supported on MgO was used. The catalyst was prepared by wet-impregnation method. Liquefied Petroleum Gas (LPG) was used as carbon source. The synthesis was conducted in atmospheric fixed bed reactor at reaction temperature range 750 – 850 °C for 30 minutes. The impregnation method applied in this study successfully deposed metal component on the MgO support surface. It found that the deposited metal components might partially replace Mg(OH){sub 2} or MgO molecules in their crystal lattice. Compare to the original MgO powder; it was significant increases in pore volume and surface area has occurred during catalyst preparation stages. The size of obtained carbon nanotubes is ranging from about 10.83 nm OD/4.09 nm ID up to 21.84 nm OD/6.51 nm ID, which means that multiwall carbon nanotubes were formed during the synthesis. Yield as much as 2.35 g.CNT/g.catalyst was obtained during 30 minutes synthesis and correspond to carbon nanotubes growth rate of 0.2 μm/min. The BET surface area of the obtained carbon nanotubes is 181.13 m{sup 2}/g and around 50 % of which is contributed by mesopores. Micropore with half pore width less than 1 nm contribute about 10% volume of total micro and mesopores volume of the carbon nanotubes. The existence of these micropores is very important to increase the hydrogen storage capacity of the carbon nanotubes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development and implementation of a portable grating interferometer system as a standard tool for testing optics at the Advanced Photon Source beamline 1-BM

We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APS beamlines for beam coherence and wavefront characterization or imaging. Herein, the design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.

47 OTHER INSTRUMENTATION↗

Simultaneous, single-pulse, synchrotron x-ray imaging and diffraction under gas gun loading

We develop a mini gas gun system for simultaneous, single-pulse, x-ray diffraction and imaging under high strain-rate loading at the beamline 32-ID of the Advanced Photon Source. In order to increase the reciprocal space covered by a small-area detector, a conventional target chamber is split into two chambers: a narrowed measurement chamber and a relief chamber. The gas gun impact is synchronized with synchrotron x-ray pulses and high-speed cameras. Depending on a camera’s capability, multiframe imaging and diffraction can be achieved. The proof-of-principle experiments are performed on single-crystal sapphire. The diffraction spots and images during impact are analyzed to quantify lattice deformation and fracture; diffraction peak broadening is largely caused by fracture-induced strain inhomogeneity. Finally, our results demonstrate the potential of such multiscale measurements for revealing and understanding high strain-rate phenomena at dynamic extremes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Latest experiences and future plans on NSLS-II insertion devices

National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy at the Brookhaven National Laboratory (BNL). The horizontal emittance of the electron beam with the currently installed six damping wigglers is 0.9 nm.rad, which could be further reduced to 0.5 nm.rad with more insertion devices (IDs). With only one RF cavity the beam current is restricted to 200 mA. Five hundred mA operation is envisaged for next year with an addition of the second cavity. Six (plus two branches) beamlines have been commissioned in the initial phase of the project. In July 2015, three NIH funded beamlines called “Advanced Beamlines for Biological Investigations with X-rays” (ABBIX) will be added for operation. This paper describes the experiences of ID development, installation, and commissioning for the NSLS-II project as well as our future plans to improve the performance of the facility in terms of source development.

43 PARTICLE ACCELERATORS↗

Progress on the development of the next generation x-ray beam position monitors at the advanced photon source

Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source (APS). The next generation XBPMs for high heat load front ends (HHL FEs) have been designed to meet these requirements by utilizing Cu K-edge x-ray fluorescence (XRF) from a pair of copper absorbers and have been installed at the front ends (FEs) of the APS. Commissioning data showed a significant performance improvement over the existing photoemission-based XBPMs. While a similar design concept can be applied for the canted undulator front ends, where two undulator beams are separated by 1.0-mrad, the lower beam power (< 10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from the diamond blades placed edge-on to the x-ray beam. A prototype of the Compton scattering XBPM system was installed at 24-ID-A in May 2015. In this report, the design and test results for XRF-based XBPM and Compton scattering based XBPM are presented. Ongoing research related to the development of the next generation XBPMs on thermal contact resistance of a joint between two solid bodies is also discussed.

43 PARTICLE ACCELERATORS↗

Conceptual design of front ends for the advanced photon source multi-bend achromats upgrade

The proposed Advanced Photon Source (APS) upgrade from a double-bend achromats (DBA) to multi-bend achromats (MBA) lattice with ring energy change from 7 GeV to 6 GeV and beam current from 100 mA to 200 mA poses new challenges for front ends. All front ends must be upgraded to fulfill the following requirements: 1) handle the high heat load from two insertion devices in either inline or canted configuration, 2) include a clearing magnet in the front end to deflect and dump any electrons in case the electrons escape from the storage ring during swap-out injection with the safety shutters open, 3) incorporate the next generation x-ray beam position monitors (XBPMs) into the front end to meet the new stringent beam stability requirements. This paper presents the evaluation of the existing APS front ends and standardizes the insertion device (ID) front ends into two types: one for the single beam and one for the canted beams. The conceptual design of high heat load front end (HHLFE) and canted undulator front end (CUFE) for APS MBA upgrade is presented.

43 PARTICLE ACCELERATORS↗

Design and delivery of the diamond double double bend achromat project

A major project is underway at Diamond Light Source to remove one of the 24 Double Bend Achromat (DBA) Storage Ring cells and replace it with a Double Double Bend Achromat (DDBA). In this way a new Insertion Device (ID) straight can be created and so ID light can be produced and delivered to a beamline previously only capable of receiving Bending Magnet (BM) radiation. This project is in support of the micro-focus Protein Crystallography (MX) beamline VMX-m which is scheduled to take users towards the end of 2017. This paper describes the Engineering Design of the DDBA project in more detail and gives the current status of the project.

43 PARTICLE ACCELERATORS↗

Photon beamline frontends for the PETRA III extension project

The photon beamline frontend design for the new insertion device (ID) beamlines of the PETRA III extension project will be presented. The design is based on the concepts developed for the photon beamline frontends at PETRA III. This generic design approach minimized the number of specialized components for all beamlines. The girder concept with kinematic mounts at each girder allowed a fast and reliable installation phase. The extension beamlines are located in two new additional buildings. There will be 4 sectors with two undulator IDs in each sector with a canting angle of 20 mrad between the insertion devices. Additionally, two straight sections and a bending magnet chamber will be modified: one straight section will be transformed to a side station sector, the straight section with the 40 m long damping wiggler will be used as a hard X-ray source, and the bending magnet will serve as a soft-X-ray source.

43 PARTICLE ACCELERATORS↗

Commissioning of the synchrotron radiation protection system and beamlines frontends at NSLS-II

The first eight insertion devices (IDs) at the NSLS-II were commissioned during the fall run of 2014. In this paper we discuss commissioning of the synchrotron radiation protection (SRP) system and beamline frontends (FE) for the respective IDs. We describe the diagnostics utilized if FE commissioning and a procedure that was used for the alignment of the photon beam from insertion devices in the beamline frontends. Then we discuss the current status of the SRP system and operation of the commissioned frontends.

43 PARTICLE ACCELERATORS↗

Experimental setup combining in situ hard X-ray photoelectron spectroscopy and real-time surface X-ray diffraction for characterizing atomic and electronic structure evolution during complex oxide heterostructure growth

We describe the next-generation system for in situ characterization of a complex oxide thin film and heterostructure growth by pulsed laser deposition (PLD) using synchrotron hard X-rays. The system consists of a PLD chamber mounted on a diffractometer allowing both real-time surface X-ray diffraction (SXRD) and in situ hard X-ray photoelectron spectroscopy (HAXPES). HAXPES is performed in the incident X-ray energy range from 4 to 12 keV using a Scienta EW4000 electron energy analyzer mounted on the PLD chamber fixed parallel with the surface normal. In addition to the standard application mode of HAXPES for disentangling surface from bulk properties, the increased penetration depth of high energy photoelectrons is used for investigation of the electronic structure changes through thin films grown deliberately as variable thickness capping layers. Such heterostructures represent model systems for investigating a variety of critical thickness and dead layer phenomena observed at complex oxide interfaces. In this new mode of operation, in situ HAXPES is used to determine the electronic structure associated with unique structural features identified by real-time SXRD during thin film growth. The system is configured for using both laboratory excitation sources off-line and on-line operation at beamline 33-ID-D at the Advanced Photon Source. We illustrate the performance of the system by preliminary scattering and spectroscopic data on oxygen vacancy ordering induced perovskite-to-brownmillerite reversible phase transformation in La 2/3 Sr 1/3 MnO 3 films capped with oxygen deficient SrTiO 3–δ (100) layers of varying thickness.

47 OTHER INSTRUMENTATION↗

Spatio-temporal ion temperature and velocity measurements in a Z pinch using fast-framing spectroscopy

Ion Doppler spectroscopy (IDS) is a diagnostic technique that measures plasma ion temperature and velocity without perturbing the plasma with a physical probe. The ZaP-HD Flow Z-Pinch Experiment at the University of Washington uses this technique to resolve radial temperature and velocity profiles of a Z-pinch plasma. The pinch lifetime is approximately 100 ms, therefore diagnostics capable of sub-microsecond resolution are required to measure the evolution of temperature and velocity profiles. The previous IDS diagnostic system was only capable of collecting a single measurement during a plasma pulse. Here, an improved system has been developed to measure radially-resolved ion temperature and velocity for the entire Z-pinch lifetime. A Kirana 05M ultra-fast framing camera and SIL ultraviolet intensifier are used to record up to 100 spectra per plasma pulse. The temperature is computed from Doppler broadening of the carbon-III (229.687 nm) impurity ion radiation and the velocity from the Doppler shift of carbon-III. Measurements are able to resolve the evolution of the ion temperature and velocity over the course of a plasma pulse. The diagnostic has significantly reduced the number of pulses required and provides a more coherent measurement of plasma dynamics than the previous system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

Band emission↗

Advanced flip-coil system for magnetic field integral measurements of insertion devices

A novel flip-coil measurement system has been developed for the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory. This paper describes the design, implementation, and commissioning of the new measurement bench, highlighting its key features, including improved mechanical stability, advanced data acquisition, and enhanced reproducibility. The system enables precise characterization of field integrals and multipole components, ensuring the optimal performance of Insertion Devices (IDs) before installation in the NSLS-II storage ring. The flip-coil system incorporates an innovative approach to minimize mechanical and electrical errors, which significantly improves the reproducibility of measurements. In addition, the system features a state-of-the-art data acquisition system that enables real-time monitoring and analysis, further enhancing the efficiency and accuracy of the measurement process. Furthermore, preliminary tests have demonstrated that the new system meets the stringent requirements for magnetic field characterization of advanced insertion devices, making it an essential tool for future ID commissioning and quality assurance at NSLS-II.

36 MATERIALS SCIENCE↗