Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Helium cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Cryogenic monocrystalline silicon Fabry-Perot cavity for the stabilization of laser frequency

A 1.6 kg silicon monocrystal was used to make a Fabry-Perot optical cavity operated at cryogenic temperatures. High-resolution thermal expansion measurements were made as the silicon cooled to 4.2 K, in order to characterize the cavity as a length reference standard. A helium-neon laser was then locked to a transmission resonance at liquid-helium temperatures, and the laser frequency tracked the cavity resonance with error fluctuations at the level of 10 Hz/sq rt Hz in the bandwidth dc to 1 Hz. Implications of the combined set of data, thermal expansion plus frequency-tracking fluctuations, for using such a system as a frequency standard are discussed.

Richard, J.-P.↗

Optical Fiber Distributed Sensing Structural Health Monitoring (SHM) Strain Measurements Taken During Cryotank Y-Joint Test Article Load Cycling at Liquid Helium Temperatures

This paper outlines cryogenic Y-joint testing at Langley Research Center (LaRC) to validate the performance of optical fiber Bragg grating strain sensors for measuring strain at liquid helium temperature (-240 C). This testing also verified survivability of fiber sensors after experiencing 10 thermal cool-down, warm-up cycles and 400 limit load cycles. Graphite composite skins bonded to a honeycomb substrate in a sandwich configuration comprised the Y-joint specimens. To enable SHM of composite cryotanks for consideration to future spacecraft, a light-weight, durable monitoring technology is needed. The fiber optic distributed Bragg grating strain sensing system developed at LaRC is a viable substitute for conventional strain gauges which are not practical for SHM. This distributed sensing technology uses an Optical Frequency Domain Reflectometer (OFDR). This measurement approach has the advantage that it can measure hundreds of Bragg grating sensors per fiber and the sensors are all written at one frequency, greatly simplifying fiber manufacturing. Fiber optic strain measurements compared well to conventional strain gauge measurements obtained during these tests. These results demonstrated a high potential for a successful implementation of a SHM system incorporating LaRC's fiber optic sensing system on the composite cryotank and other future cryogenic applications.

Allison, Sidney G.↗

A balloon-borne cryogenically cooled filter radiometer

The development of a cryogenically cooled filter radiometer for use with high altitude balloons is discussed. The radiometer has features which include the options for remote operation of two filter wheels each containing six filters at helium temperature and a cryogenic rotary chopper which may be run at 200 cycles per second or positioned open or closed, and a remotely operable chopped blackbody calibration source. The radiometer contains a ten inch diameter liquid nitrogen cooled Cassegrain telescope with nine individually filtered field stops in the focal plane. The telescope is mounted on a two-axis servo operated gimbal which is used to make sky scans under the control of an onboard programmer.

Debell, A. G.↗

Progress Toward a Compact 0.05 K Magnet Refrigerator Operating from 10 K

Much of the most interesting information regarding our universe is hidden in the sub-millimeter, infrared, and x-rays bands of the spectrum, to which our atmosphere is largely opaque. Thus, missions exploring these bands are a very important part of NASA s Space Science program. Coincidentally, the most sensitive detectors in these spectral regions operate at extremely low temperatures, typically 0.05 - 0.10 K. Generally these temperatures will be achieved using magnetic refrigerators, also know as Adiabatic Demagnetization Refrigerators, or ADRs. Current ADRs, such as the one used in the XRS-II instrument on the Astro-E2 satellite, use a single-stage to cool detectors from 1.3 K to 0.06 K. The ADR is designed so that it can absorb the heat on the detector stage for at least 24 hours before it must stop, warm up to the helium bath temperature (1.3 K), and dump the accumulated heat. Future detector arrays will be much larger and will have higher heat dissipation. Furthermore, future missions will use mechanical cryocoolers to provide upper stage cooling, but they can only reach 4 - 10 K. Trying to scale heavy (-15 kg) single stage ADRs up to the higher heat loads and higher heat rejection temperatures required leads to unacceptably large systems. The GSFC Cryogenics Branch has developed the Continuous ADR (CADR) to solve this problem. The CADR consists of a series of ADR stages that sequentially pass heat from the load up to the high temperature heat sink. The stage connected to the load remains at a constant temperature. The continuous stage effectively decouples detector operation from ADR operation, allowing the ADR stages to be cycled much more rapidly. Rapid cycling leads to higher cooling power density. The cascading, multistage arrangement allows the magnetic refrigerant of each stage to be optimized for its own temperature swing. In the past year, we have made good progress toward a 0.05 to 10K system. A four-stage system that operates from 4.2 K was demonstrated. Magnetic shielding was added to eliminate inter-stage coupling. Improvements were made to superconducting and passive gas-gap heat switches. A second type of passive gas gap switch, one meant for use at higher temperature, was demonstrated. The presentation will focus primarily on these recent design improvements, and on the challenges that remain on the progress toward a system that will operate from 10 K or higher.

Canavan, Edgar↗

Spectroscopy on the A 1 Π←X 1 Σ + Transition of Buffer-Gas Cooled AlCl

Aluminum monochloride (AlCl) has been proposed as an excellent candidate for laser cooling. Here we present absorption spectroscopy measurements on the A 1 Π←X 1 Σ + transition in AlCl inside a cryogenic helium buffer-gas beam cell. The high resolution absorption data enables a rigorous, quantitative comparison with our high-level ab initio calculations of the electronic and rovibronic energies, providing a comprehensive picture of the AlCl quantum structure. Further, the combination of high resolution spectral data and theory permits the evaluation of spectroscopic constants and associated properties, like equilibrium bond length, with an order of magnitude higher precision. Based on the measured molecular equilibrium constants of the A 1 Π state, we estimate a Franck-Condon factor of the A 1 Π←X 1 Σ + of 99.88%, which confirms that AlCl is amenable to laser cooling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared telescope on Spacelab 2

The infrared telescope (IRT) on Spacelab 2 which will be the first cryogenically cooled telescope operated from the Orbiter is discussed. Its objectives are to measure the induced environment about the Orbiter and to demonstrate the ability to manage a large volume of superfluid helium in space. The prime astrophysical objectives are to map extended sources of low surface brightness infrared emission, including the zodiacal light, the galactic plane, and extragalactic regions. The IRT design is described, including the f/4 15.2 cm highly baffled Herschelian telescope cooled to 8 K which may scan to within 35 deg of the sun. The focal plane cooled to 3 K consists of nine discrete photoconductors covering the wavelength of 4.5-120 microns in five bands, with a single stellar detector used for aspect determination. Overlapping scans, contiguous orbits, and a six degree per second scan rate permit rapid redundant coverage of 60 % of the sky.

Koch, D.↗

Niobium-tin as a transformative technology for low-beta linacs

Niobium-tin has been identified as the most promising next-generation superconducting material for accelerator cavities. This is due to the higher critical temperature (Tc = 18 K) of Nb3Sn compared to niobium (TC = 9.2 K), which leads to greatly reduced RF losses in the cavity during 4.5 K operation. This allows two important changes during cavity and cryomodule design. First, the higher Tc leads to negligible BCS losses when operated at 4.5 K, which allows for a higher frequency to be used, translating to significantly smaller cavities and cryomodules. Second, the reduced dissipated power lowers the required cryogenic cooling capacity, meaning that cavities can feasibly be operated on 5-10 W cryocoolers instead of a centralized helium refrigeration plant. These plants and distribution systems are costly and complex, requiring skilled technicians for operation and maintenance. These fundamental changes present an opportunity for a paradigm shift in how low-beta linacs are designed and operated. Fabrication challenges and first coated cavity test results are discussed.

43 PARTICLE ACCELERATORS↗

Power Generation Cycle with RELAP-7

Balance of plant of a High-Temperature gas-cooled Reactor – Pebble bed Module (HTR-PM) is modeled using RELAP-7. The model includes the primary helium loop where the heat produced by the core is transferred to a helical-coil steam generator and the secondary loop where super-heated steam is fed to a turbine to extract power. The steam is then condensed to subcooled water and pumped back into the steam generator. Results demonstrate that RELAP-7 has the capability to model different regimes encountered in two-phase flow with wall boiling, superheated steam, subcooled liquid and condensation. RELAP-7 also has the capability of modeling different fluids with their own specific models in a very flexible way, without any code change. This also demonstrates the capability of modeling the transfer of fission power into electrical power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flow visualization of film cooling with spanwise injection from a small array of holes and compound-angle injection from a large array

Film injection from discrete holes in a smooth, flat plate was studied for two configurations: (1) spanwise injection through a four hole staggered array; and (2) compound angle injection through a 49 hole staggered array. The ratio of boundary layer thicknesses to hole diameter and the Reynolds number were typical of gas turbine film cooling applications. Streaklines showing the motion of the injected air were obtained by photographing small, neutrally buoyant, helium-filled soap bubbles that followed the flow field.

Russell, L. M.↗

The chemical composition of the cool white dwarf LP 701-29

New observations and a new synthetic spectrum of the cool white dwarf LP 701-29 are presented. The analysis suggests that the atmosphere of this star is helium dominated, with enhanced metal abundances compared to the usual abundances of white dwarfs. The best fit is achieved with an effective temperature of 4500 K and an abundance of heavy elements (especially Ca) of the order 0.01 of the solar ratio of metals to helium.

Kapranidis, S.↗

Direct-Circulation Stirling-Cycle Refrigerator

In proposed cryogenic system, cold working fluid (helium) circulated directly from Stirling-cycle refrigerator machinery through loop of tubing to provide 15 W of cooling power at temperature of 80 K to scientific instruments or other devices located at some distance from machinery. (Separation of cooled devices from machinery may be dictated by engineering requirements including, need to isolate cooled devices from vibrations of machinery.) Advantages include less complexity, smaller size, lighter weight, and lower power consumption.

Ellison, Woody↗

Orbital Gravity Gradiometry Beyond GOCE: Mission Concepts

Significant advances in the technologies needed for space-based cryogenic instruments have been made in the last decade, including cryocoolers, spacecraft architectures and cryogenic amplifiers. These enable considerably more complex instruments to be put into orbit for long-duration missions. One such instrument is the Superconducting Gravity Gradiometer (SGG) developed by Paik, et al. A magnetically levitated version is under consideration for a follow-on mission to GRACE (Gravity Recovery and Climate Experiment) and GOCE (Gravity field and steady-state Ocean Circulation Explorer). With its inherently greater rejection of common mode accelerations and ability to cancel the coupling of angular accelerations into the gradient signal, the SGG can achieve [an accuracy of] 0.01 milli-Eotvos (gravitational gradient of the Earth) divided by the square root of frequency in hertz, with requirements for attitude control that can be met with existing spacecraft. In addition, the use of a cryocooler for cooling the instrument will alleviate the previously severe constraint on mission lifetime imposed by the use of superfluid helium,. enabling mission durations in the 5-10 year range. Studies are underway to determine requirements for orbit (polar versus sun-synchronous), altitude (which affects spacecraft drag), instrument temperature and stability, cryocooler vibration control, and control and readout electronics. These will be used to determine the SGG's sensitivity and ultimate resolution for gravity recovery. This paper will discuss preliminary instrument and spacecraft design, and toplevel mission requirements.

Shirron, Peter J.↗

Nb3Sn Superconducting Cavity Developments for Heavy-ion Beams

Nb3Sn has been identified as the most promising next-generation superconducting material for accelerator cavities. This is due to the higher critical temperature (Tc = 18 K) of Nb3Sn compared to niobium (Tc = 9.2 K), which leads to greatly reduced RF losses in the cavity during 4.5 K operation. This allows two important changes during cavity and cryomodule design. First, the higher Tc leads to negligible BCS losses when operated at 4.5 K, which allows for a higher frequency to be used, translating to significantly smaller cavities and cryomodules. Second, the reduced dissipated power lowers the required cryogenic cooling capacity, meaning that cavities can feasibly be operated on 5-10 W cryocoolers instead of a centralized helium refrigeration plant. These plants and distribution systems are costly and complex, requiring skilled technicians for operation and maintenance. These fundamental changes present an opportunity for a paradigm shift in how low-beta linacs are designed and operated. Fabrication and testing results of first prototypes are discussed.

Petersen, T. [Argonne]↗

The broadening of the calcium resonance line in a high-temperature helium atmosphere

The paper describes experimental measurements of the shape of the Ca I resonance line at 4227 A in a high-temperature helium atmosphere. A ballistic piston compressor was used to produce hot helium in the temperature range from 3000 to 7000 K and the number-density range from 2 to 4 by 10 to the 20th power per cu cm, which conditions approximate those postulated for the atmospheres of certain cool white-dwarf stars. The Boltzmann temperature of the calcium atoms was measured by the brightness-emissivity method, the absorption line shape was measured with a twelve-channel polychromator, and the helium kinetic temperature was calculated from the equation of an ideal gas. The observed deviation from thermodynamic equilibrium is illustrated. The value of the ratio of the damping constant to the helium number density at 5000 K is found to be 45 (+ or - 4) by 10 to the -22nd power A cu cm, or 4.7 (+ or - 0.4) by 10 to the -9th power rad/s cu cm. It is noted that no existing line-broadening calculation for the calcium-helium system is consistent with the present results. Recent studies of the 4227-A line in spectra of the sun and the white dwarf van Maanen 2 are discussed.

Driver, R. D.↗

Analysis of Flow Area in the Axial Cross-Vessel Annular Duct Following a Breach of the Primary Helium Boundary of an HTGR

The lock-exchange flow phenomenon has been heavily studied for decades, including the lock-exchange phenomenon that takes place during an air ingress accident in a High-Temperature Gas-cooled Reactor (HTGR) during a break on the axial cross-vessel duct. The present study aims to characterize the gas dynamics in the cavity region of an HTGR, particularly the axial cross-vessel outer duct region. This study computes the velocity and flow area of the heavy and light currents when a break on the primary helium boundary occurs. This analysis is supported using experimental data from experiments conducted in a 1/20th length-scale HTGR. The following study summarizes the conditions of the experiment, the approach adopted to predict the flow area, and future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of multi-stage telescopic control rods in a pebble bed reactor. Part II: corrosion and wear performance

To support High-Temperature Gas-Cooled Reactor designs, the effects of corrosion and wear on a SS316L telescopic control rod prototype were investigated in helium at 775 °C with up to 5 ppm oxygen for durations up to 500 h. Three deployment conditions were tested to assess their impact on wear and oxide formation: severe cycles, daily cycles, and gravity-driven deployments. Here, a chromium-rich oxide layer developed on regions exposed to the helium flow, reaching up to 2 µm in the most affected areas. No carburization or decarburization was observed. Oxide breakthrough occurred mainly at grooves and contact points during severe cycling of the telescopic rod, while in the other tests it was limited to contact points. Friction forces increased due to oxide growth and thermal expansion, the latter being the dominant factor, but never enough to hinder rod deployment significantly. Coaxial misalignment of stages was identified as the main potential risk to reliable operation under normal conditions.

Control rod↗

Elevated temperature contact creep and friction of nickel-based superalloys using machine learning assisted finite element analysis

Nickel-based superalloys with superior thermochemical, mechanical, and tribological properties are highly utilized for critical components in several high temperature applications such as gas turbines and nuclear reactors. Inconel 617, in particular, is considered as one of the main candidate superalloys for tribo-components in very-high-temperature gas-cooled nuclear reactors. Recent findings indicate that this alloy grows unique surface oxide especially in a high-temperature helium environment with distinctive wear, friction, and contact properties. Here, this study investigates the high temperature contact area evolution and frictional behavior of Inconel 617 using finite element simulation and provides predictive models for the contact and friction performance at different normal loads, dwell times, and temperatures. High temperature helium-aged Inconel 617 top surface properties (up to 600 °C) are utilized along with a single asperity-based deformable elastic-plastic contact model under combined normal and tangential loading. Machine learning is used to assist the finite element results and to predict friction coefficient as well as contact area evolution. While a small difference is observed in the instantaneous friction coefficient (no dwell time) for all temperatures, friction coefficient increases considerably with dwell time. This shows that the effect of contact creep for longer dwell times significantly dominants the effect of high temperature variation in basic mechanical parameters such as modulus and yield strength. It is found that increasing temperature and dwell times lead to the friction coefficient increase, yet the dominance of dwell time effects decreases at higher temperatures and loads. While the analysis is presented for Inconel 617, the methodology is easy to be generalized and can be applied to other HT alloys.

36 MATERIALS SCIENCE↗