Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Thermal Protection System P50 Cork Environments and Response due to Radiative Heating

Space Launch System (SLS) experienced deflagration of the acreage of the Core Stage base heat shield during the Green Run hot-fire test campaigns and Artemis I flight. The burning products from the base heat shield during Green Run hot-fire test operation led to concerns in aerothermal environments and thermal protection system (TPS) performance prior to Artemis I flight. This work documents a highly controlled ground test within the NASA Marshall Space Flight Center’s Nonmetallic Materials Branch thermal vacuum chamber (TVC) and investigates the P50 cork heat transfer environments and thermal protection system (TPS) response due to sensitivity changes in radiative heat rates, ambient pressure, air entrainment mass flow rates, test gas and TPS sample types. An SLS ascent ambient pressure profile was also simulated within the TVC facility. This test data enabled the efforts toward the Artemis I SLS post-flight reconstruction and initial assessment of flight TPS performance. A ground test program was developed to gain an in-depth understanding of the cork combustion dynamics and TPS response due to the SLS launch vehicle flight ascent environments.

thermal protection system↗

C II forbidden line emission from spiral galaxies

Measurements of 158-micron forbidden emission taken from a sample of 13 gas-rich galaxies are analyzed. The new data are combined with the previous sample of six infrared-bright galaxies. The 158-micron line emission line is bright in all of the galaxies detected, amounting to between 0.1 and 0.2 percent of the total nuclear far-infrared luminosity, and is therefore one of the primary gas coolants in these regions. A close association between 158-micron line emission and CO line emission is noted, with the integrated 158-micron/CO line intensity ratio being substantially less in galaxies than in Galactic star-formation regions. However, for the starburst galaxies the integrated line intensity ratio is the same as that for star-formation regions in the Galaxy.

Stacey, G. J.↗

Gas analysis of Apollo 12, 14, and 15 samples by laser-probe mass spectrometry

Solar wind gases, cosmogenic gases from high energy spallation reactions from soxmic rays, and radiogenic gases from decay of radioactive potassium and from uranium and thorium isotopes were analyzed in lunar materials. Details are presented on two aspects of the studies: (1) The spatial distribution of Ar-40/Ar-38 ages in lunar breccia 14301 was determined. The ages of clasts within this breccia are 3.68 + or - 0.09 and 2.9 + or - 0.3 x 10 to the 9th power years. Parentless radiogenic Ar-40 exists within the fine-grained matrix. (2) The distribution of helium, neon, and argon isotopes within Apollo 15 samples results primarily from fractionated solar wind gases, accompanied by small quantities of cosmogenic gases. Comparison of this Apollo 15 data with Kapoeta and Fayetteville meteorite and Apollo 12 and 14 data indicates that solar wind implantation followed by fractionation of the gases was primarily responsible for incorporation of original gas phase within solid bodies of the solar system.

Imegrue, G. H.↗

The Trash Compaction Processing Systems (TCPS) Ground Unit Control Sample Testing

The Trash Compaction Processing System (TCPS) is being developed by NASA and Sierra Space to process crew trash for long-duration missions. The system compacts and thermally processes mixed spacecraft waste to reduce volume and stabilize the material while managing gas and liquid effluents. A Ground Unit (GU) located at Sierra Space in Madison, Wisconsin was used to run a series of tests using standardized control samples representing different trash conditions, including nominal, high liquid, high cloth, benign, and foam. Gas grab samples were collected during processing and analyzed to identify the compounds present in the effluent stream and compare the concentrations to the NASA spacecraft maximum allowable concentrations (SMACs). Additional testing included odor testing at White Sands Test Facility, aerosol measurements, microbiology, and tile characterization. Overall, the compounds detected in the gas samples were well below the SMAC limits for all trash models tested. The results from this testing are being used to help guide the verification approach and test planning for the TCPS Flight Unit that is planned for on-orbit testing on the International Space Station.

Control Samples↗

Study of carbon compounds in Apollo 12 and 14 lunar samples.

The results of gas-chromatography and high-resolution mass spectroscopy studies of gases released on deuterium fluoride dissolution of Apollo 12 and 14 lunar samples are reported. The results confirm previous observations that CH4 and C2H6 are released as well as CD4, C2D4, C2D6, and higher deuterated hydrocarbons. The yields correlate with the total carbon content of the samples, and the CH4 and C2H6 released may be regarded as indigenous, while the deuterated products result from hydrolysis of carbide material. The results provide the first experimental confirmation of the hypothesis that the CH4 derives from solar wind interactions.

Holland, P. T.↗

X-Ray Computed Tomography During Preliminary Examination of Apollo Drive Tube 73001

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This began with unsealed core tube 73002 [1,2] that is the upper part of a station 3 double drive tube. More recently the pro-gram extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dis-section [5] of 73001, the lower half of the station 3 double drive tube, that was sealed under vacuum on the Moon. In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) Core Sample Vacuum Container (CSVC). XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube, to ensure it was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into In-Ag alloy). Both scans will provide constraints on future work of this type, particularly for samples collected during the Artemis mission. Another finding from these "engineering" scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection; and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. So far, 92 of the 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition. Because of the dust adhering to particle exteriors it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and basalts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

Surface film effects on drop tube undercooling studies

The effects of various gaseous atmospheric constituents on drop-tube solidified samples of elemental metals were examined from a microstructural standpoint. All specimens were prepared from the purest available elements, so effects of impurities should not account for the observed effects. The drop-tube gas has a definite effect on the sample microstructure. Most dramatically, the sample cooling rate is effected. Some samples receive sufficient cooling to solidify in free fall while others do not, splating at the end of the drop tube in the sample catcher. Gases are selectively absorbed into the sample. Upon solidification gas can become less soluble and as a result forms voids within the sample. The general oxidation/reduction characteristics of the gas also affect sample microstructures. In general, under the more favorable experimental conditions including reducing atmospheric conditions and superheatings, examination of sample microstructures indicates that nucleation has been suppressed. This is indicated by underlying uniform dendrite spacings throughout the sample and with a single dendrite orientation through most of the sample. The samples were annealed yielding a few large grains and single or bi-crystal samples were commonly formed. This was especially true of samples that were inadvertently greatly superheated. This is in contrast with results from a previous study in which surface oxides were stable and contained numerous sites of nucleation. The number of nucleation events depends upon the surface state of the specimen as determined by the atmosphere and is consistent with theoretical expectations based upon the thermodynamic stability of surface oxide films. Oxide-free specimens are characterized by shiny surfaces, with no observable features under the scanning electron microscope at 5000X.

Ethridge, E. C.↗

malbacR: A Package for Standardized Implementation of Batch Correction Methods for Omics Data

Mass spectrometry is a powerful tool for identifying and analyzing small molecules, such as metabolites and lipids, in com-plex biological samples. Liquid chromatography and gas chromatography mass spectrometry studies quite commonly in-volve large numbers of samples, which can require significant time for sample preparation and analyses. To accommodate such studies, the samples are commonly split into batches. Inevitably, variations in sample handling, temperature fluctua-tion, imprecise timing, column degradation and other factors result in systematic errors or biases of the measured abundances between the batches. Numerous methods are available via R packages to assist with batch correction for small molecule om-ics data; however, since these methods were developed by different research teams, the algorithms are available in separate R packages, each with different data input and output formats. We introduce the malbacR package which consolidates eleven common batch effect correction methods for small molecule omics data into one place so users can easily implement and compare: pareto scaling, power scaling, range scaling, ComBat, EigenMS, NOMIS, RUV-random, QC-RLSC, WaveI-CA2.0, TIGER, and SERRF. The malbacR package standardizes data input and output formats across these batch correction methods. The package works in conjunction with the pmartR package, allowing users to seamlessly include batch effect cor-rection in a pmartR workflow without needing any additional data manipulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nucleation Behavior of Oxygen-Acetylene Torch-Produced Diamond Films

A mechanism is presented for the nucleation of diamond in the combustion flame environment. A series of six experiments and two associated simulations provide results from which the mechanism was derived. A substantial portion of the prior literature was reviewed and the data and conclusions from the previous experimenters were found to support the proposed mechanism. The nucleation mechanism builds on the work of previous researchers but presents an approach to nucleation in a detail and direction not fully presented heretofore. This work identifies the gas phase as the controlling environment for the initial formation steps leading to nucleation. The developed mechanism explains some of the difficulty which has been found in producing single crystal epitaxial films. An experiment which modified the initial gas phase precursor using methane and carbon monoxide is presented. Addition of methane into the precursor gases was found to be responsible for pillaring of the films. Atomic force microscopy surface roughness data provides a reasonable look at suppression of nucleation by carbon monoxide. Surface finish data was taken on crystals which were open to the nucleation environment and generally parallel to the substrate surface. The test surfaces were measured as an independent measure of the instantaneous nucleation environent. A gas flow and substrate experiment changed the conditions on the surface of the sample by increasing the gas flow rate while remaining on a consistent point of the atomic constituent diagram, and by changing the carbide potential of the substrate. Two tip modification experiments looked at the behavior of gas phase nucleation by modifying the shape and behavior of the flame plasma in which the diamond nucleation is suspected to occur. Diamond nucleation and growth was additionally examined using a high-velocity oxygen fuel gun and C3H6 as the fuel gas phase precursor with addition of carbon monoxide gas 01 addition of liquid toluene.

Roberts, F. E.↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

Providing adequate carbon dioxide (CO2) washout is essential to the reduction of risk in performing suited operations. Long term CO2 exposure can lead to symptoms such as headache, lethargy, dizziness, and in severe cases can lead to unconsciousness and death. Thus maintaining adequate CO2 washout in both ground testing and during in flight EVAs is a requirement of current and future suit designs. It is necessary to understand the inspired CO2 of suit wearers such that future requirements for space suits appropriately address the risk of inadequate washout. Testing conducted by the EVA Physiology Laboratory at the NASA Johnson Space Center aimed to characterize a method for noninvasively measuring inspired oronasal CO2 under pressurized suited conditions in order to better inform requirements definition and verification techniques for future CO2 washout limits in space suits. Prior work conducted by the EPL examined several different wearable, respirator style, masks that could be used to sample air from the vicinity surround the nose and mouth of a suited test subject. Previously published studies utilized these masks, some being commercial products and some novel designs, to monitor CO2 under various exercise and flow conditions with mixed results for repeatability and/or consistency between subjects. Based on a meta-analysis of those studies it was decided to test a nasal cannula as it is a commercially available device that is placed directly in the flow path of the user as they breathe. A nasal cannula was used to sample air inhaled by the test subjects during both rest and exercise conditions. Eight subjects were tasked with walking on a treadmill or operating an arm ergometer to reach target metabolic rates of 1000, 2000, and 3000 BTU/hr. Suit pressure was maintained at 4.3 psid for all tests, with supply flow rates of 6, 4, and 2 actual cubic feet per minute depending on the test condition. Each test configuration was conducted twice with subjects breathing either through their nose only, or however they felt comfortable. By restricting breathing through a single orifice, we are able to more accurately define exactly what flow stream the sampled CO2 is taken from. Oronasal CO2 was monitored using real time infrared gas analyzers fed via sample tubes connected to the nasal cannula within the suit. Two additional sampling tubes were placed at the head and chin of the test subject, in an effort to capture CO2 concentrations across the entire flow stream of the Mark-III vent system (flow path is head to neck). Metabolic rate was calculated via the exhaust CO2 concentration and used to adjust subject workload on either the treadmill or arm ergometer until the target was reached. Forward work will aim to characterize the historically accepted minimum ppCO2 in suit during EVA by repeating this study in the Extravehicular Mobility Unit (EMU) space suit. This will help to define washout requirements for future suits, be they NASA (e.g. Z-2) or Commercial Crew designed. Additionally it is important to determine the functional consequences of CO2 exposure during EVA. Severe CO2 symptoms are a result of very high concentration, acute exposures. While long term, low concentration exposures have been shown to result in slight cognitive decline, symptoms resolve upon quickly returning to nominal concentrations and it remains unknown the impact that minor deficits in cognitive performance can have on EVA performance.

Norcross, J.↗

Spacelab Charcoal Analyses

This report describes analytical methods and results obtained from chemical analysis of 31 charcoal samples in five sets. Each set was obtained from a single scrubber used to filter ambient air on board a Spacelab mission. Analysis of the charcoal samples was conducted by thermal desorption followed by gas chromatography/mass spectrometry (GC/MS). All samples were analyzed using identical methods. The method used for these analyses was able to detect compounds independent of their polarity or volatility. In addition to the charcoal samples, analyses of three Environmental Control and Life Support System (ECLSS) water samples were conducted specifically for trimethylamine.

Slivon, L. E.↗

BOREAS TGB-6 Soil Methane Oxidation and Production from NSA BP and Fen Sites

The BOReal Ecosystem-Atmosphere Study Trace Gas Biogeochemistry (BOREAS TGB-6) team collected soil methane measurements at several sites in the Southern Study Area (SSA) and Northern Study Area (NSA). This data set contains soil methane consumption (bacterial CH4 oxidation) and associated C-13 fractionation effects in samples that were collected at various sites in 1994 and 1996 from enclosures (chambers). Methane C-13 data in soil gas samples from the NSA Young Jack Pine (YJP) and Old Jack Pine (OJP) sites for 1994 and 1996 are also given. Additional data on the isotopic composition of methane (carbon and hydrogen isotopes) produced in the NSA beaver ponds and fen bog in 1993 and 1994 are given as well. The data are stored in tabular ASCII files.

Deck, Bruce↗

Evolved Gas Analysis and X-Ray Diffraction of Carbonate Samples from the 2009 Arctic Mars Analog Svalbard Expedition: Implications for Mineralogical Inferences from the Mars Science Laboratory

The 2009 Arctic Mars Analog Svalbard Expedition (AMASE) investigated several geologic settings using methodologies and techniques being developed or considered for future Mars missions, such as the Mars Science Laboratory (MSL), ExoMars, and Mars Sample Return (MSR). AMASE-related research comprises both analyses conducted during the expedition and further analyses of collected samples using laboratory facilities at a variety of institutions. The Sample Analysis at Mars (SAM) instrument suite, which will be part of the Analytical Laboratory on MSL, consists of a quadrupole mass spectrometer (QMS), a gas chromatograph (GC), and a tunable laser spectrometer (TLS). An Evolved Gas Analysis Mass Spectrometer (EGA-MS) was used during AMASE to represent part of the capabilities of SAM. The other instrument included in the MSL Analytical Laboratory is CheMin, which uses X-Ray Diffraction (XRD) and X-Ray Fluorescence (XRF) to perform quantitative mineralogical characterization of samples. Field-portable versions of CheMin were used during the AMASE 2009. Here, we discuss the preliminary interpretation of EGA and XRD analyses of selected AMASE carbonate samples and implications for mineralogical interpretations from MSL. Though CheMin will be the primary mineralogical tool on MSL, SAM EGA could be used to support XRD identifications or indicate the presence of volatile-bearing minerals which may be near or below XRD detection limits. Data collected with instruments in the field and in comparable laboratory setups (e.g., the SAM breadboard) will be discussed.

McAdam, A. C.↗

A simplified method for determining heat of combustion of natural gas

A simplified technique for determination of the heat of combustion of natural gas has been developed. It is a variation of the previously developed technique wherein the carrier air, in which the test sample was burnt, was oxygen enriched to adjust the mole fraction of oxygen in the combustion product gases up to that in the carrier air. The new technique eliminates the need for oxygen enrichment of the experimental mixtures and natural gas samples and has been found to predict their heats of combustion to an uncertainty of the order of 1 percent.

Singh, Jag J.↗

The OSIRIS-REx Spacecraft and the Touch-and-Go Sample Acquisition Mechanism (TAGSAM)

The Origins, Spectral-Interpretation, Resource-Identification, Security and Regolith- Explorer (OSIRIS-REx) spacecraft supports all aspects of the mission science objectives, from extensive remote sensing at the asteroid Bennu, to sample collection and return to Earth. In general, the success of planetary missions requires the collection, return, and analysis of data, which in turn depends on the successful operation of instruments and the host spacecraft. In the case of OSIRIS-REx, a sample-return mission, the spacecraft must also support the acquisition, safe stowage, and return of the sample. The target asteroid is Bennu, a B-class near-Earth asteroid roughly 500 m diameter. The Lockheed Martin-designed and developed OSIRIS-REx spacecraft draws significant heritage from previous missions and features the Touch-and-Go-Sample-Acquisition-Mechanism, or TAGSAM, to collect sample from the surface of Bennu. Lockheed Martin developed TAGSAM as a novel, simple way to collect samples on planetary bodies. During short contact with the asteroid surface, TAGSAM releases curation-grade nitrogen gas, mobilizing the surface regolith into a collection chamber. The contact surface of TAGSAM includes "contact pads", which are present to collect surface grains that have been subject to space weathering. Extensive 1-g laboratory testing, "reduced-gravity" testing (via parabolic flights on an airplane), and analysis demonstrate that TAGSAM will collect asteroid material in nominal conditions, and a variety of off-nominal conditions, such as the presence of large obstacles under the TAGSAM sampling head, or failure in the sampling gas firing. TAGSAM, and the spacecraft support of the instruments, are central to the success of the mission.

Spacecraft↗

Continuous analysis of nitrogen dioxide in gas streams of plants

Analyzer and sampling system continuously monitors nitrogen dioxide concentrations in the feed and tail gas streams of a facility recovering nitric acid. The system, using a direct calorimetric approach, makes use of readily available equipment and is flexible and reliable in operation.

Durkin, W. T.↗

Gas chromatograph injection port protective device

To prevent samples containing foreign matter from poisoning the gas chromatographic columns, a pre-filter insertion is placed in the injection port. The packing becomes a variable reactant, for example, acids are removed by using an alkaline liquid.

Robertson, M. D.↗

MSR Science Planning Group 2 (MSPG2): Science & Curation Considerations for Time Sensitive Measurements That Should be Performed in Containment

The Perseverance rover is currently collecting samples on the martian surface for potential return to Earth and planning is underway to develop facilities to study these samples. Perseverance will collect up to 38 samples that will be sealed in TiN tubes. As long as the tubes remain sealed the samples will be metastable. However, as soon as a tube is opened, or headspace gas is extracted these samples will begin to re-equilibrate with their new surroundings. The MSPG2 time-sensitive science sub-group attempted to quantify the rates at which alteration is likely to occur assuming the samples are opened and stored in a nitrogen atmosphere at room temperature. The group also recommended ~20 instruments for inclusion in a sample receiving facility to allow the time sensitive properties of these samples to be measured before they are irreversibly altered.

Aaron B Regberg↗