Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLANDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

The functions of caspase in whitefly Bemisia tabaci apoptosis in response to ultraviolet irradiation

Abstract Whiteflies ( Bemisia tabaci ) are phloem feeders, and some invasive species are composed of cryptic species complexes that cause extensive crop damage, particularly via the direct transmission of plant viruses. Apoptosis is a type of programmed cell death essential for organismal development and tissue homeostasis. The caspases belong to a family of cysteine proteases that play a central role in the initiation of apoptosis in many organisms. Here, we employed a comprehensive genomics approach to identity caspases in B. tabaci Middle East Asia Minor 1 (MEAM1), an invasive whitefly that carries a cryptic species complex that is devastating to crops. Four caspase genes were identified, and their motif compositions were predicted. Structures were relatively conserved in both putative effector and initiator caspases. Expression patterns of caspase genes differed across insect developmental stages. Three caspase genes were induced immediately after ultraviolet (UV) treatment. Expression levels of Bt‐caspase‐1 and Bt‐caspase‐3b increased in the midgut and salivary glands during apoptosis induced by UV treatments, whereas silencing of both genes reduced UV‐triggered apoptosis. Our study demonstrates that Bt‐caspase‐1 and Bt‐caspase‐3b, respectively, act as putative initiator and effector apoptotic caspases in the MEAM1 whitefly.

Wang, X. ‐R.↗

Realtime light dosimetry software tools for interstitial photodynamic therapy of the human prostate

Photodynamic therapy (PDT) for the treatment of prostate cancer has been demonstrated to be a safe treatment option capable of inducing tissue destruction and decreasing prostate specific antigen (PSA) levels. However, prostate-PDT results in large intra- and interpatient variations in treatment response, possibly due to biological variations in tissue composition and short-term response to the therapeutic irradiation. Within our group, an instrument for interstitial PDT on prostate tissue has been developed that combines therapeutic light delivery and monitoring of light transmission via numerous bare-ended optical fibers. Here, we present algorithms that utilize data on the light distribution within the target tissue to provide realtime treatment feedback based on a light dose threshold model for PDT. This realtime dosimetry module is implemented to individualize the light dose and compensate for any treatment-induced variations in light attenuation. More specifically, based on the light transmission signals between treatment fibers, spatially resolved spectroscopy is utilized to assess the effective attenuation coefficient of the tissue. These data constitute input to a block-Cimmino optimization algorithm, employed to calculate individual fiber irradiation times provided the requirement to deliver a predetermined light dose to the target tissue while sparing surrounding sensitive organs. By repeatedly monitoring the light transmission signals during the entire treatment session, optical properties and individual fiber irradiation times are updated in realtime. The functionality of the algorithms is tested on diffuse light distribution data simulated by means of the finite element method (FEM). The feasibility of utilizing spatially resolved spectroscopy within heterogeneous media such as the prostate gland is discussed. Furthermore, we demonstrate the ability of the block-Cimmino algorithm to discriminate between target tissue and organs at risk (OAR). Finally, the realtime dosimetry module is evaluated for treatment scenarios displaying spatially and temporally varying light attenuation levels within the target tissue. We conclude that the realtime dosimetry module makes it possible to deliver a certain light dose to the target tissue despite spatial and temporal variations of the target tissue optical properties at the therapeutic wavelength.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An algorithm for shifting MLC shapes to adjust for daily prostate movement during concurrent treatment with pelvic lymph nodes

Concurrent treatment of the prostate and the pelvic lymph nodes encounters the problem of the prostate gland moving independently from the pelvic lymph nodes on a daily basis. The purpose of this study is to develop a leaf-tracking algorithm for adjustment of IMRT portals without requirement of online dose calculation to account for daily prostate position during concurrent treatment with pelvic lymph nodes. A leaf-shifting algorithm was developed and programmed to adjust the positions of selected MLC leaf pairs according to prostate movement in the plane perpendicular to each beam angle. IMRT plans from five patients with concurrent treatment of the prostate and pelvic lymph nodes were selected to test the feasibility of this algorithm by comparison with isocenter-shifted plans, using defined dose endpoints. When the prostate moved 0.5, 1.0, and 1.5 cm along the anterior/posterior direction, the average doses to 95% of the prostate (D{sub 95%}) for the iso-shift plans were similar to the MLC-shift plans, (54.7, 54.4, and 54.1 Gy versus 54.5, 54.3, and 53.9 Gy, respectively). The corresponding D{sub 95%} averages to the pelvic lymph nodes were reduced from the prescription dose of 45 Gy to 42.7, 38.3, and 34.0 Gy for iso-shift plans (p=0.04 for each comparison), while the D{sub 95%} averages for the MLC-shift plans did not significantly differ from the prescription dose, at 45.0, 44.8, and 44.5 Gy. Compensation for prostate movement along the superior/inferior direction was more complicated due to a limiting MLC leaf width of 1.0 cm. In order to concurrently treat the prostate and pelvic lymph nodes with the prostate moving independently, shifting selected MLC leaf pairs may be a more practical adaptive solution than shifting the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate intrafraction motion evaluation using kV fluoroscopy during treatment delivery: A feasibility and accuracy study

Margin reduction for prostate radiotherapy is limited by uncertainty in prostate localization during treatment. We investigated the feasibility and accuracy of measuring prostate intrafraction motion using kV fluoroscopy performed simultaneously with radiotherapy. Three gold coils used for target localization were implanted into the patient's prostate gland before undergoing hypofractionated online image-guided step-and-shoot intensity modulated radiation therapy (IMRT) on an Elekta Synergy linear accelerator. At each fraction, the patient was aligned using a cone-beam computed tomography (CBCT), after which the IMRT treatment delivery and fluoroscopy were performed simultaneously. In addition, a post-treatment CBCT was acquired with the patient still on the table. To measure the intrafraction motion, we developed an algorithm to register the fluoroscopy images to a reference image derived from the post-treatment CBCT, and we estimated coil motion in three-dimensional (3D) space by combining information from registrations at different gantry angles. We also detected the MV beam turning on and off using MV scatter incident in the same fluoroscopy images, and used this information to synchronize our intrafraction evaluation with the treatment delivery. In addition, we assessed the following: the method to synchronize with treatment delivery, the dose from kV imaging, the accuracy of the localization, and the error propagated into the 3D localization from motion between fluoroscopy acquisitions. With 0.16 mAs/frame and a bowtie filter implemented, the coils could be localized with the gantry at both 0 deg. and 270 deg. with the MV beam off, and at 270 deg. with the MV beam on when multiple fluoroscopy frames were averaged. The localization in two-dimensions for phantom and patient measurements was performed with submillimeter accuracy. After backprojection into 3D the patient localization error was (-0.04{+-}0.30) mm, (0.09{+-}0.36) mm, and (0.03{+-}0.68) mm in the right-left (RL), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. Simulations showed that while oscillating (stationary) motion cannot be effectively represented in 3D, linearly drifting (nonstationary) motion is detectable with good accuracy. These results show that measuring prostate intrafraction motion using a single kV imager during radiotherapy is feasible and can be performed with acceptable accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A NTCP approach for estimating the outcome in radioiodine treatment of hyperthyroidism

Radioiodine has been in use for over 60 years as a treatment for hyperthyroidism. Major changes in clinical practice have led to accurate dosimetry capable of avoiding the risks of adverse effects and the optimization of the treatment. The aim of this study was to test the capability of a radiobiological model, based on normal tissue complication probability (NTCP), to predict the outcome after oral therapeutic {sup 131}I administration. Following dosimetric study, 79 patients underwent treatment for hyperthyroidism using radioiodine and then 67 had at least a one-year follow up. The delivered dose was calculated using the MIRD formula, taking into account the measured maximum uptake of administered iodine transferred to the thyroid, U0, and the effective clearance rate, T{sub eff} and target mass. The dose was converted to normalized total dose delivered at 2 Gy per fraction (NTD{sub 2}). Furthermore, the method to take into account the reduction of the mass of the gland during radioiodine therapy was also applied. The clinical outcome and dosimetric parameters were analyzed in order to study the dose-response relationship for hypothyroidism. The TD{sub 50} and m parameters of the NTCP model approach were then estimated using the likelihood method. The TD{sub 50}, expressed as NTD{sub 2}, resulted in 60 Gy (95% C.I.: 45-75 Gy) and 96 Gy (95% C.I.: 86-109 Gy) for patients affected by Graves or autonomous/multinodular disease, respectively. This supports the clinical evidence that Graves' disease should be characterized by more radiosensitive cells compared to autonomous nodules. The m parameter for all patients was 0.27 (95% C.I.: 0.22-0.36). These parameters were compared with those reported in the literature for hypothyroidism induced after external beam radiotherapy. The NTCP model correctly predicted the clinical outcome after the therapeutic administration of radioiodine in our series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant

A Monte Carlo (MC) study was carried out to evaluate the effects of the interseed attenuation and the tissue composition for two models of {sup 125}I low dose rate (LDR) brachytherapy seeds (Medi-Physics 6711, IBt InterSource) in a permanent breast implant. The effect of the tissue composition was investigated because the breast localization presents heterogeneities such as glandular and adipose tissue surrounded by air, lungs, and ribs. The absolute MC dose calculations were benchmarked by comparison to the absolute dose obtained from experimental results. Before modeling a clinical case of an implant in heterogeneous breast, the effects of the tissue composition and the interseed attenuation were studied in homogeneous phantoms. To investigate the tissue composition effect, the dose along the transverse axis of the two seed models were calculated and compared in different materials. For each seed model, three seeds sharing the same transverse axis were simulated to evaluate the interseed effect in water as a function of the distance from the seed. A clinical study of a permanent breast {sup 125}I implant for a single patient was carried out using four dose calculation techniques: (1) A TG-43 based calculation, (2) a full MC simulation with realistic tissues and seed models, (3) a MC simulation in water and modeled seeds, and (4) a MC simulation without modeling the seed geometry but with realistic tissues. In the latter, a phase space file corresponding to the particles emitted from the external surface of the seed is used at each seed location. The results were compared by calculating the relevant clinical metrics V{sub 85}, V{sub 100}, and V{sub 200} for this kind of treatment in the target. D{sub 90} and D{sub 50} were also determined to evaluate the differences in dose and compare the results to the studies published for permanent prostate seed implants in literature. The experimental results are in agreement with the MC absolute doses (within 5% for EBT Gafchromic film and within 7% for TLD-100). Important differences between the dose along the transverse axis of the seed in water and in adipose tissue are obtained (10% at 3.5 cm). The comparisons between the full MC and the TG-43 calculations show that there are no significantdifferences for V{sub 85} and V{sub 100}. For V{sub 200}, 8.4% difference is found coming mainly from the tissue composition effect. Larger differences (about 10.5% for the model 6711 seed and about 13% for the InterSource{sup 125}) are determined for D{sub 90} and D{sub 50}. These differences depend on the composition of the breast tissue modeled in the simulation. A variation in percentage by mass of the mammary gland and adipose tissue can cause important differences in the clinical dose metrics V{sub 200}, D{sub 90}, and D{sub 50}. Even if the authors can conclude that clinically, the differences in V{sub 85}, V{sub 100}, and V{sub 200} are acceptable in comparison to the large variation in dose in the treated volume, this work demonstrates that the development of a MC treatment planning system for LDR brachytherapy will improve the dose determination in the treated region and consequently the dose-outcome relationship, especially for the skin toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT

Purpose: High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based ''demons'' algorithm. Methods: Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintain the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a displacement map was generated. Segmented volumes in the CT images deformed using the displacement field were compared against the manual segmentations in the CBCT images to quantitatively measure the convergence of the shape and the volume. Other image features were also used to evaluate the overall performance of the registration. Results: The algorithm was able to complete the segmentation and registration process within 1 min, and the superimposed clinical objects achieved a volumetric similarity measure of over 90% between the reference and the registered data. Validation results also showed that the proposed registration could accurately trace the deformation inside the target volume with average errors of less than 1 mm. The method had a solid performance in registering the simulated images with up to 20 Hounsfield unit white noise added. Also, the side by side comparison with the original demons algorithm demonstrated its improved registration performance over the local pixel-based registration approaches. Conclusions: Given the strength and efficiency of the algorithm, the proposed method has significant clinical potential to accelerate and to improve the CBCT delineation and targets tracking in online IGRT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biological consequences of MLC calibration errors in IMRT delivery and QA

Purpose: The purpose of this work is threefold: (1) to explore biological consequences of the multileaf collimator (MLC) calibration errors in intensity modulated radiotherapy (IMRT) of prostate and head and neck cancers, (2) to determine levels of planning target volume (PTV) and normal tissue under- or overdose flagged with clinically used QA action limits, and (3) to provide biologically based input for MLC QA and IMRT QA action limits. Methods: Ten consecutive prostate IMRT cases and ten consecutive head and neck IMRT cases were used. Systematic MLC offsets (i.e., calibration error) were introduced for each control point of the plan separately for X1 and X2 leaf banks. Offsets were from - 2 to 2 mm with a 0.5 mm increment. The modified files were imported into the planning system for forward dose recalculation. The original plan served as the reference. The generalized equivalent uniform dose (gEUD) was used as the biological index for the targets, rectum, parotid glands, brainstem, and spinal cord. Each plan was recalculated on a CT scan of a 27 cm diameter cylindrical phantom with a contoured 0.6 cc ion chamber. Dose to ion chamber and 3D gamma analysis were compared to the reference plan. QA pass criteria: (1) at least 95% of voxels with a dose cutoff of 50% of maximum dose have to pass at 3 mm/3% and (2) dose to chamber within 2% of the reference dose. Results: For prostate cases, differences in PTV and rectum gEUD greater than 2% were identified. However, a larger proportion of plans leading to greater than 2% difference in prostate PTV gEUD passed the ion chamber QA but not 3D gamma QA. A similar trend was found for the rectum gEUD. For head and neck IMRT, the QA pass criteria flagged plans leading to greater than 4% differences in PTV gEUD and greater than 5% differences in the maximum dose to brainstem. If pass criteria were relaxed to 90% for gamma and 3% for ion chamber QA, plans leading to a 5% difference in PTV gEUD and a 5%-8% difference in brainstem maximum dose would likely pass IMRT QA. A larger proportion of head and neck plans with greater than 2% PTV gEUD difference passed 3D gamma QA compared to ion chamber QA. Conclusions: For low modulation plans, there is a better chance to catch MLC calibration errors with 3D gamma QA rather than ion chamber QA. Conversely, for high modulation plans, there is a better chance to catch MLC calibration errors with ion chamber QA rather than with 3D gamma QA. Ion chamber and 3D gamma analysis IMRT QA can detect greater than 2% change in gEUD for PTVs and critical structures for low modulation treatment plans. For high modulation treatment plans, ion chamber and 3D gamma analysis can detect greater than 2% change in gEUD for PTVs and a 5% change in critical structure gEUD since either QA methods passes the QA criteria. For gEUD changes less than those listed above, either QA method has the same proportion of passing rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed variation in the shape and volume of the segmented prostate in diagnostic and intraprocedural images. The probabilistic method allowed us to convey registration results in terms of posterior distributions, with the dispersion providing a patient-specific estimate of the registration uncertainty. The median of the predictive distance distribution between the deformed prostate boundary and the segmented boundary was Less-Than-Or-Slanted-Equal-To 3 mm (95th percentiles within {+-}4 mm) for all ten patients. The accuracy and precision of the internal deformation was evaluated by comparing the posterior predictive distance distribution for the CZ-PZ interface for each patient, with the median distance ranging from -0.6 to 2.4 mm. Posterior predictive distances between naturally occurring landmarks showed registration errors of Less-Than-Or-Slanted-Equal-To 5 mm in any direction. The uncertainty was not a global measure, but instead was local and varied throughout the registration region. Registration uncertainties were largest in the apical region of the prostate. Conclusions: Using a Bayesian nonrigid registration method, the authors determined the posterior distribution on deformations between diagnostic and intraprocedural MR images and quantified the uncertainty in the registration results. The feasibility of this approach was tested and results were positive. The probabilistic framework allows us to evaluate both patient-specific and location-specific estimates of the uncertainty in the registration result. Although the framework was tested on MR-guided procedures, the preliminary results suggest that it may be applied to TRUS-guided procedures as well, where the addition of diagnostic MR information may have a larger impact on target definition and clinical guidance.

60 APPLIED LIFE SCIENCES↗

Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor control probability (TCP) and normal tissue complication probability (NTCP). To assess potential local RBE variations, LET distributions were calculated with Monte Carlo, and compared for different plans. The results were assessed in terms of their sensitivity to uncertainties in model parameters and delivery. Results: IFD courses included equal number of fractions boosting either hemisphere, thus, the combined physical dose was close to uniform throughout the prostate. However, for the entire course, the prostate EUD in IFD was higher than in conventional FTP by up to 14%, corresponding to the estimated increase in TCP to 96% from 88%. The extent of gain depended on the mixing factor, i.e., relative weights used to combine FTP and STP spot weights. Increased weighting of STP typically yielded a higher target EUD, but also led to increased sensitivity of dose to variations in the proton's range. Rectal and bladder EUD were same or lower (per normalization), and the NTCP for both remained below 1%. The LET distributions in IFD also depended strongly on the mixing weights: plans using higher weight of STP spots yielded higher LET, indicating a potentially higher local RBE. Conclusions: In proton therapy delivered by pencil beam scanning, improved therapeutic outcome can potentially be expected with delivery of IFD distributions, while administering the prescribed quasi-uniform dose to the target over the entire course. The biological effectiveness of IFD may be further enhanced by optimizing the LET distributions. IFD distributions are characterized by a dose gradient located in proximity of the prostate's midplane, thus, the fidelity of delivery would depend crucially on the precision with which the proton range could be controlled.

60 APPLIED LIFE SCIENCES↗

Dose-shaping using targeted sparse optimization

Purpose: Dose volume histograms (DVHs) are common tools in radiation therapy treatment planning to characterize plan quality. As statistical metrics, DVHs provide a compact summary of the underlying plan at the cost of losing spatial information: the same or similar dose-volume histograms can arise from substantially different spatial dose maps. This is exactly the reason why physicians and physicists scrutinize dose maps even after they satisfy all DVH endpoints numerically. However, up to this point, little has been done to control spatial phenomena, such as the spatial distribution of hot spots, which has significant clinical implications. To this end, the authors propose a novel objective function that enables a more direct tradeoff between target coverage, organ-sparing, and planning target volume (PTV) homogeneity, and presents our findings from four prostate cases, a pancreas case, and a head-and-neck case to illustrate the advantages and general applicability of our method.Methods: In designing the energy minimization objective (E{sub tot}{sup sparse}), the authors utilized the following robust cost functions: (1) an asymmetric linear well function to allow differential penalties for underdose, relaxation of prescription dose, and overdose in the PTV; (2) a two-piece linear function to heavily penalize high dose and mildly penalize low and intermediate dose in organs-at risk (OARs); and (3) a total variation energy, i.e., the L{sub 1} norm applied to the first-order approximation of the dose gradient in the PTV. By minimizing a weighted sum of these robust costs, general conformity to dose prescription and dose-gradient prescription is achieved while encouraging prescription violations to follow a Laplace distribution. In contrast, conventional quadratic objectives are associated with a Gaussian distribution of violations, which is less forgiving to large violations of prescription than the Laplace distribution. As a result, the proposed objective E{sub tot}{sup sparse} improves tradeoff between planning goals by 'sacrificing' voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E{sub tot}{sup sparse} occurs as a result. For example, large violations to dose prescription in the PTV in E{sub tot}{sup sparse}-optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since E{sub tot}{sup sparse}-optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index.Results: The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1-4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH plots and dose maps. After developing intuition by planning the four prostate cases, which had relatively few tradeoffs, the authors applied our method to a 7-field 6 MV pancreas case and a 9-field 6MV head-and-neck case to test the potential impact of our method on more challenging cases. The authors found that our formulation: (1) provided excellent flexibility for balancing OAR-sparing with PTV homogeneity; and (2) permitted the dose planner more control over the evolution of the PTV's spatial dose distribution than conventional objective functions. In particular, E{sub tot}{sup sparse}-optimized plans for the pancreas case and head-and-neck case exhibited substantially improved sparing of the spinal cord and parotid glands, respectively, while maintaining or improving sparing for other OARs and markedly improving PTV homogeneity. Plan deliverability for E{sub tot}{sup sparse}-optimized plans was shown to be better than their associated clinical plans, according to the two-dimensional modulation index.Conclusions: These results suggest that our formulation may be used to improve dose-shaping and OAR-sparing for complicated disease sites, such as the pancreas or head and neck. Furthermore, our objective function and constraints are linear and constitute a linear program, which converges to the global minimum quickly, and can be easily implemented in treatment planning software. Thus, the authors expect fast translation of our method to the clinic where it may have a positive impact on plan quality for challenging disease sites.

61 RADIATION PROTECTION AND DOSIMETRY↗

Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using spherical tumor shapes as opposed to no shape assumption. However, an assumption of spherical tumor shape for RMSE = 3.5 mm led to a mean overestimation of tumor sampling probabilities of 3%, implying that assuming spherical tumor shape may be reasonable for many prostate tumors. The authors also determined that a biopsy system would need to have a RMS needle delivery error of no more than 1.6 mm in order to sample 95% of tumors with one core. The authors’ experiments also indicated that the effect of axial-direction error on the measured tumor burden was mitigated by the 18 mm core length at 3.5 mm RMSE. Conclusions: For biopsy systems with RMSE ≥ 3.5 mm, more than one biopsy core must be taken from the majority of tumors to achieveP ≥ 95%. These observations support the authors’ perspective that some tumors of clinically significant sizes may require more than one biopsy attempt in order to be sampled during the first biopsy session. This motivates the authors’ ongoing development of an approach to optimize biopsy plans with the aim of achieving a desired probability of obtaining a sample from each tumor, while minimizing the number of biopsies. Optimized planning of within-tumor targets for MRI-3D TRUS fusion biopsy could support earlier diagnosis of prostate cancer while it remains localized to the gland and curable.

60 APPLIED LIFE SCIENCES↗

SU-E-I-58: Detecting Tumors with Extremely Low Contrast in CT Images

Purpose: Tumors such as the prostate focal lesions and the brain metastases have extremely low CT contrast and MRI is usually used for target delineation. The target contours are propagated to the CT for treatment planning and patient positioning. We have employed an advanced denoising method eliminating the noise and allow magnification of subtle contrast of these focal lesions on CT. Methods: Five prostate and two brain metastasis patients with MRI T2, diffusion or dynamic contrast enhanced (DCE) images confirmed focal lesions were included. One brain patients had 5 metastases. A block matching 3D (BM3D) algorithm was adapted to reduce the noise of kVCT images used for treatment planning. The gray-level range of the resultant images was narrowed to magnify the tumor-normal tissue contrast. Results: For the prostate patients, denoised kVCT images showed focal regions at 5, 8,11-1, 2, and 8–10 oclock for the 5 patients, this is highly consistent to the radiologist confirmed focal lesions based on MRI at 5, 7, 11-1, 2 and 8–10 oclock in the axial plane. These CT focal regions matched well with the MRI focal lesions in the cranio-caudal position. The average increase in density compared to background prostate glands was 0.86%, which corresponds to ∼50% increase in cellularity and is lower than the average CT noise level of 2.4%. For the brain patients, denoised kVCT showed 5/6 metastases. The high CT-density region of a metastasis is 2-mm off from its corresponding elevated MRI perfusion center. Overall the detecting sensitivity was 91%. Conclusion: It has been preliminarily demonstrated that the higher tumor cellularity can be detected using kVCT. The low contrast-to-noise information requires advanced denoising to reveal. The finding is significant to radiotherapy by providing an additional tool to locate focal lesions for confirming MRI-CT registration and providing a highly accessible outcome assessment tool.

60 APPLIED LIFE SCIENCES↗

SU-E-T-109: Development of An End-To-End Test for the Varian TrueBeamtm with a Novel Multiple-Dosimetric Modality H and N Phantom

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Methods: The initial end-to-end test and custom H and N phantom were designed to yield maximum information in anatomical regions significant to H and N plans with respect to: i) geometric accuracy, ii) dosimetric accuracy, and iii) treatment reproducibility. The phantom was designed in collaboration with Integrated Medical Technologies. A CT image was taken with a 1mm slice thickness. The CT was imported into Varian's Eclipse treatment planning system, where OARs and the PTV were contoured. A clinical template was used to create an eight field static gantry angle IMRT plan. After optimization, dose was calculated using the Analytic Anisotropic Algorithm with inhomogeneity correction. Plans were delivered with a TrueBeam equipped with a high definition MLC. Preliminary end-to-end results were measured using film and ion chambers. Ion chamber dose measurements were compared to the TPS. Films were analyzed with FilmQAPro using composite gamma index. Results: Film analysis for the initial end-to-end plan with a geometrically simple PTV showed average gamma pass rates >99% with a passing criterion of 3% / 3mm. Film analysis of a plan with a more realistic, ie. complex, PTV yielded pass rates >99% in clinically important regions containing the PTV, spinal cord and parotid glands. Ion chamber measurements were on average within 1.21% of calculated dose for both plans. Conclusion: trials have demonstrated that our end-to-end testing methods provide baseline values for the dosimetric and geometric accuracy of Varian's TrueBeam system.

60 APPLIED LIFE SCIENCES↗

SU-E-T-289: Scintillating Fiber Based In-Vivo Dose Monitoring System to the Rectum in Proton Therapy of Prostate Cancer: A Geant4 Monte Carlo Simulation

Purpose: To construct a dose monitoring system based on an endorectal balloon coupled to thin scintillating fibers to study the dose delivered to the rectum during prostate cancer proton therapy Methods: The Geant4 Monte Carlo toolkit version 9.6p02 was used to simulate prostate cancer proton therapy treatments of an endorectal balloon (for immobilization of a 2.9 cm diameter prostate gland) and a set of 34 scintillating fibers symmetrically placed around the balloon and perpendicular to the proton beam direction (for dosimetry measurements) Results: A linear response of the fibers to the dose delivered was observed within <2%, a property that makes them good candidates for real time dosimetry. Results obtained show that the closest fiber recorded about 1/3 of the dose to the target with a 1/r{sup 2} decrease in the dose distribution as one goes toward the frontal and distal top fibers. Very low dose was recorded by the bottom fibers (about 45 times comparatively), which is a clear indication that the overall volume of the rectal wall that is exposed to a higher dose is relatively minimized. Further analysis indicated a simple scaling relationship between the dose to the prostate and the dose to the top fibers (a linear fit gave a slope of −0.07±0.07 MeV per treatment Gy) Conclusion: Thin (1 mm × 1 mm × 100 cm) long scintillating fibers were found to be ideal for real time in-vivo dose measurement to the rectum for prostate cancer proton therapy. The linear response of the fibers to the dose delivered makes them good candidates of dosimeters. With thorough calibration and the ability to define a good correlation between the dose to the target and the dose to the fibers, such dosimeters can be used for real time dose verification to the target.

60 APPLIED LIFE SCIENCES↗

SU-E-T-295: Simultaneous Beam Sampling and Aperture Shape Optimization for Station Parameter Optimized Radiation Therapy (SPORT)

Purpose: Station Parameter Optimized Radiation Therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital LINACs, in which the station parameters of a delivery system, (such as aperture shape and weight, couch position/angle, gantry/collimator angle) are optimized altogether. SPORT promises to deliver unprecedented radiation dose distributions efficiently, yet there does not exist any optimization algorithm to implement it. The purpose of this work is to propose an optimization algorithm to simultaneously optimize the beam sampling and aperture shapes. Methods: We build a mathematical model whose variables are beam angles (including non-coplanar and/or even nonisocentric beams) and aperture shapes. To solve the resulting large scale optimization problem, we devise an exact, convergent and fast optimization algorithm by integrating three advanced optimization techniques named column generation, gradient method, and pattern search. Column generation is used to find a good set of aperture shapes as an initial solution by adding apertures sequentially. Then we apply the gradient method to iteratively improve the current solution by reshaping the aperture shapes and updating the beam angles toward the gradient. Algorithm continues by pattern search method to explore the part of the search space that cannot be reached by the gradient method. Results: The proposed technique is applied to a series of patient cases and significantly improves the plan quality. In a head-and-neck case, for example, the left parotid gland mean-dose, brainstem max-dose, spinal cord max-dose, and mandible mean-dose are reduced by 10%, 7%, 24% and 12% respectively, compared to the conventional VMAT plan while maintaining the same PTV coverage. Conclusion: Combined use of column generation, gradient search and pattern search algorithms provide an effective way to optimize simultaneously the large collection of station parameters and significantly improves quality of resultant treatment plans as compared with conventional VMAT or IMRT treatments.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a PET/Cerenkov-light hybrid imaging system

Purpose: Cerenkov-light imaging is a new molecular imaging technology that detects visible photons from high-speed electrons using a high sensitivity optical camera. However, the merit of Cerenkov-light imaging remains unclear. If a PET/Cerenkov-light hybrid imaging system were developed, the merit of Cerenkov-light imaging would be clarified by directly comparing these two imaging modalities. Methods: The authors developed and tested a PET/Cerenkov-light hybrid imaging system that consists of a dual-head PET system, a reflection mirror located above the subject, and a high sensitivity charge coupled device (CCD) camera. The authors installed these systems inside a black box for imaging the Cerenkov-light. The dual-head PET system employed a 1.2 × 1.2 × 10 mm{sup 3} GSO arranged in a 33 × 33 matrix that was optically coupled to a position sensitive photomultiplier tube to form a GSO block detector. The authors arranged two GSO block detectors 10 cm apart and positioned the subject between them. The Cerenkov-light above the subject is reflected by the mirror and changes its direction to the side of the PET system and is imaged by the high sensitivity CCD camera. Results: The dual-head PET system had a spatial resolution of ∼1.2 mm FWHM and sensitivity of ∼0.31% at the center of the FOV. The Cerenkov-light imaging system's spatial resolution was ∼275μm for a {sup 22}Na point source. Using the combined PET/Cerenkov-light hybrid imaging system, the authors successfully obtained fused images from simultaneously acquired images. The image distributions are sometimes different due to the light transmission and absorption in the body of the subject in the Cerenkov-light images. In simultaneous imaging of rat, the authors found that {sup 18}F-FDG accumulation was observed mainly in the Harderian gland on the PET image, while the distribution of Cerenkov-light was observed in the eyes. Conclusions: The authors conclude that their developed PET/Cerenkov-light hybrid imaging system is useful to evaluate the merits and the limitations of Cerenkov-light imaging in molecular imaging research.

60 APPLIED LIFE SCIENCES↗

Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0.86%, and the prostate volume Dice overlap coefficient was 91.89% ± 1.19%. Conclusions: The authors have developed a novel approach to improve prostate contour utilizing intraoperative TRUS-based prostate volume in the CT-based prostate HDR treatment planning, demonstrated its clinical feasibility, and validated its accuracy with MRIs. The proposed segmentation method would improve prostate delineations, enable accurate dose planning and treatment delivery, and potentially enhance the treatment outcome of prostate HDR brachytherapy.

60 APPLIED LIFE SCIENCES↗