Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Florida”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Effluent monitoring of the December 10, 1974, Titan 3-E launch at Air Force Eastern Test Range, Florida

Surface and airborne field measurements of the cloud behavior and effluent dispersion from a solid rocket motor launch vehicle are presented. The measurements were obtained as part of a continuing launch vehicle effluent monitoring program to obtain experimental field measurements in order to evaluate a model used to predict launch vehicle environmental impact. Results show that the model tends to overpredict effluent levels.

Wornom, D. E.↗

A demonstration of wetland vegetation mapping in Florida from computer-processed satellite and aircraft multispectral scanner data

The author has identified the following significant results. Major vegetative classes identified by the remote sensing technique were cypress swamp, pine, wetland grasses, salt grass, mixed mangrove, black mangrove, Brazilian pepper. Australian pine and melaleuca were not satisfactorily classified from LANDSAT. Aircraft scanners provided better resolution resulting in a classification of finer surface detail. An edge effect, created by the integration of diverse spectral responses within boundary elements of digital data, affected the wetlands classification. Accuracy classification for aircraft was 68% and for LANDSAT was 74%.

Butera, M. K.↗

Solar energy meets 50 pecent of motel hot water needs--Key West, Florida

Final report describes domestic water preheat installed in 148 room motel. Equipment meets 50 percent of needs when motel is 100 percent occupied; equivalently, it supplies 100 percent of hot water when occupancy is 50 percent. System consists of 1,400 square feet of flat plate liquid solar collectors, storage tanks, pump, controller, and hardware.

Source record↗

Economic evaluation of a solar hot-water system--Palm Beach County, Florida

Report projects solar-energy costs and savings for residential hot-water system over 20 year period. Evaluation uses technical and economic models with inputs based on working characteristics of installed system. Primary analysis permits calculation of economic viability for four other U.S. sites.

Source record↗

Motel solar-hot-water system with nonpressurized storage--Jacksonville, Florida

Modular roof-mounted copper-plated arrays collect solar energy; heated water drains from them into 1,000 gallon nonpressurized storage tank which supplies energy to existing pressurized motel hot water lines. System provides 65 percent of hot water demand. Report described systems parts and operation, maintenance, and performance and provides warranty information.

Source record↗

University of Florida nuclear pumped laser program

The mechanism of excitation of laser gases by fast ions (triton, proton, or fission fragments) and especially any role UF6 might play in radiative deexcitation of these gases were investigated. Population densities of excited important for laser action were obtained. Nuclear pumped CW-laser systems, especially He-Ne and CO2, were studied using steady state reactors. It was demonstrated that He-Ne lases in a CW-mode with nuclear pumping at both the red and the infrared transition. The infrared transition was observed to be superradiant.

Richard T. Schneider↗

Solar energy system performance evaluation: Seasonal report for SEMCO, Loxahatchee, Florida

The operational and thermal performance of a variety of solar systems installed in operational test sites are described. The analysis used is based on instrumented system data monitored and collected for at least one full season of operation. The long-term field performance of the installed system and the technical contributions to the definition of techniques and requirements solar energy system design are analyzed. The solar energy system was designed to supply domestic hot water for a family of four, single-family residences. It consists of two liquid flat plate collectors, single tank, controls, and transport lines.

Source record↗

A diffusion climatology for Cape Canaveral, Florida

The problem of toxic effluent released by a space shuttle launch on local plant and animal life is discussed. Based on several successive years of data, nine basic weather patterns were identified, and the probabilities of pattern occurrence, of onshore/alongshore cloud transport, of precipitation accompanying the latter, and of ground-level concentrations of hydrogen chloride were determined. Diurnal variations for the patterns were also investigated. Sketches showing probable movement of launch cloud exhaust and isobaric maps are presented.

Siler, R. K.↗

Solar energy system economic evaluation final report for SEMCO-Loxahatchee, Loxahatchee National Wildlife refuge, Palm Beach County, Florida

Economic analysis of the solar energy system installed at Loxahatchee, was developed for Loxahatchee and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis was accomplished based on the technical and economic models in the f Chart design procedure with inputs based on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system costs over a projected twenty year life, life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables was also investigated. The results demonstrate that the solar energy system is economically viable at all of the five sites for which the analysis was conducted.

Source record↗

A narrow clear zone over Florida and the Atlantic Ocean

A narrow cloud-free zone of large longitudinal extent was observed in visible and infrared satellite imagery on September 21, 1978. An attempt to explain the zone in terms of subsidence induced by a transverse frontal circulation is presented.

Negri, A. J.↗

Solar hot water system installed at Days Inn Motel, Jacksonville, Florida

The solar system was designed to provide 65 percent of the hot water demand. Water in the liquid flat plate collector (900 square feet) system automatically drains into the 1000 gallon lined and vented steel storage tank when the pump is not running. Heat is transferred from storage to Domestic Hot Water (DHW) tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up DHW standby losses. All pumps are controlled by differential temperature.

Source record↗

Acid rain at Kennedy Space Center, Florida - Recent observations

During the period July, 1977 to September, 1979, rainfall was collected in the vicinity of the Kennedy Space Center and subjected to appropriate chemical analysis for purposes of characterization of general composition and acidity. Results obtained form the basis for future comparisons, should significant alteration of the chemical composition of rain occur during the space shuttle era. Acidity extremes calculated on a monthly basis from event samples collected from five sites within a 200 sq km area varied from pH 5.1 in November, 1977, and April, 1978 to pH 4.3 in July, 1978 and July, 1979. Weighted average pH for the entire period was 4.55. Acidity was due to the presence of sulfuric and nitric acids. The mole ratio of excess SO4(-2):NO3(-) was typically greater than one. Monthly weighted average Cl(-) concentrations ranged from 20-240 micromoles/liter. The Cl(-):Na(+) ratio was slightly lower than that present in sea water.

Madsen, B. C.↗

Hydraulics and geology related to beach restoration in Lee County, Florida

The erosion problem on Captiva Island is discussed. It is due to a deficit in the sand budget of the littoral drift system; a system with losses due to attrition of the particles and mass losses into the lagoons, to offshore, and to lateral transport. The effect that reopening Blind Pass would have, and the placement of sediment retaining structures in the surf zone at the northern and southern limits of the Captiva beach system, wave examined. A geological approach was used to study the origin and dynamic changes that have occurred. Through hydraulic modeling, changes that will occur by reopening and stabilizing Blind Pass are predicted. It is concluded that if the island is to be stabilized, beach nourishment with proper amounts and particle size is a necessity and that jetties adequate to restrict lateral and offshore losses are essential. It is shown that the reopening of Blind Pass would have minimal effects on the passes to the north and south, and would improve the environmental conditions in the sound with no adverse effects on the beach system.

Winton, T.↗

Use of thermal inertia determined by HCMM to predict nocturnal cold prone areas in Florida

Surface temperatures derived from HCMM data were compared with to those obtained by GOES satellite and the apparent thermal inertia (ATI) calculated. For two dates, the HCMM temperatures appear to be about 5 C lower than the GOES temperatures. The ATI for excessively-drained to well-drained mineral soils was greater than for drained organic soils possibly because of long periods of low rainfall during late 1980 and early 1981. Organic soils cropped to sugar cane showed lower ATI after a severe killing freeze. With dead leaves, there was less transpiration and more solar radiation probably reached the dark soil surface. This would explain the larger diurnal temperature amplitude observed.

Allen, L. H., Jr.↗