At least 631 records · Page 35

Air-sparged hydrocyclone for cryogenic gas vapor separation

An air-sparged hydrocyclone for separating a vapor from a carrier gas is disclosed. The cyclone comprises a porous sparger covered by an outer gas plenum. A cryogenic liquid is injected to a tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the air-sparged hydrocyclone. The carrier gas is injected into the cyclone through the porous sparger. The vapor dissolves, condenses, desublimates, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted carrier gas is drawn through a vortex finder and the vapor-enriched cryogenic liquid is drawn through an apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

Baxter, Larry↗

Testing and Performance Validation of a Sensitive Gamma Ray Camera Designed for Radiation Detection and Decommissioning Measurements in Nuclear Facilities-13044

This paper describes the measurements, testing and performance validation of a sensitive gamma ray camera designed for radiation detection and quantification in the environment and decommissioning and hold-up measurements in nuclear facilities. The instrument, which is known as RadSearch, combines a sensitive and highly collimated LaBr{sub 3} scintillation detector with an optical (video) camera with controllable zoom and focus and a laser range finder in one detector head. The LaBr{sub 3} detector has a typical energy resolution of between 2.5% and 3% at the 662 keV energy of Cs-137 compared to that of NaI detectors with a resolution of typically 7% to 8% at the same energy. At this energy the tungsten shielding of the detector provides a shielding ratio of greater than 900:1 in the forward direction and 100:1 on the sides and from the rear. The detector head is mounted on a pan/tile mechanism with a range of motion of ±180 degrees (pan) and ±90 degrees (tilt) equivalent to 4 π steradians. The detector head with pan/tilt is normally mounted on a tripod or wheeled cart. It can also be mounted on vehicles or a mobile robot for access to high dose-rate areas and areas with high levels of contamination. Ethernet connects RadSearch to a ruggedized notebook computer from which it is operated and controlled. Power can be supplied either as 24-volts DC from a battery or as 50 volts DC supplied by a small mains (110 or 230 VAC) power supply unit that is co-located with the controlling notebook computer. In this latter case both power and Ethernet are supplied through a single cable that can be up to 80 metres in length. If a local battery supplies power, the unit can be controlled through wireless Ethernet. Both manual operation and automatic scanning of surfaces and objects is available through the software interface on the notebook computer. For each scan element making up a part of an overall scanned area, the unit measures a gamma ray spectrum. Multiple radionuclides may be selected by the operator and will be identified if present. In scanning operation the unit scans a designated region and superimposes over a video image the distribution of measured radioactivity. For the total scanned area or object RadSearch determines the total activity of operator selected radionuclides present and the gamma dose-rate measured at the detector head. Results of hold-up measurements made in a nuclear facility are presented, as are test measurements of point sources distributed arbitrarily on surfaces. These latter results are compared with the results of benchmarked MCNP Monte Carlo calculations. The use of the device for hold-up and decommissioning measurements is validated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DAMSA Experiment Conceptual Design White Paper

DAMSA (DArk Messenger Searches at an Accelerator) is a novel short-baseline accelerator experiment aimed at probing short-lived physics processes, including searches for evidence of a dark sector of particle physics and well-motivated Standard Model signals. Motivated by open questions in neutrino physics and the absence of conclusive evidence for conventional weakly interacting massive particles, DAMSA targets MeV-to-sub-GeV dark-sector messengers with feeble couplings that can be produced in abundance at the PIP-II LINAC. By employing an ultra-short baseline of order one meter, DAMSA is uniquely positioned to overcome the beam-dump "ceiling" that limits sensitivity to promptly decaying particles in longer-baseline experiments. The conceptual design emphasizes a beam-dump production scheme combined with a compact detector optimized for rare decays while mitigating intense neutron-induced backgrounds inherent to high-power proton beams. To validate the experimental strategy and detector technologies, the Little DAMSA Path-Finder (LDPF) proof-of-concept experiment is proposed, focusing on axion-like particles decaying to two photons and operating with 300 MeV electron beams at FAST. Successful realization of LDPF will establish the feasibility of the DAMSA approach, enabling a broad and powerful program to explore short-lived new physics and precision Standard Model processes in a previously inaccessible regime. This conceptual design document outlines the technical details of DAMSA's physics goals, the beam facility proposals, key experimental challenges and how to overcome them, and the proposed experimental staging campaigns.

Bhattarai, Prithak [Texas U., Arlington]↗

LCLS Undulator Commissioning, Alignment, and Performance

The LCLS x-ray FEL has recently achieved its 1.5-Angstrom lasing and saturation goals upon first trial. This was achieved as a result of a thorough pre-beam checkout, both traditional and beam-based component alignment techniques, and high electron beam brightness. The x-ray FEL process demands very tight tolerances on the straightness of the electron beam trajectory (<5 {micro}m) through the LCLS undulator system. Tight, but less stringent tolerances of {approx}100 {micro}m rms were met for the transverse placement of the individual undulator segments with respect to the beam axis. The tolerances for electron beam straightness can only be met through a beam-based alignment (BBA) method, which is implemented using large electron energy variations and sub-micron resolution cavity beam position monitors (BPM), with precise conventional alignment used to set the starting conditions. Precision-fiducialization of components mounted on remotely adjustable girders, and special beam-finder wires (BFW) at each girder have been used to meet these challenging alignment tolerances. Longer-term girder movement due to ground motion and temperature changes are being monitored, continuously, by a unique stretched wire and hydrostatic level Alignment Diagnostics System (ADS).

43 PARTICLE ACCELERATORS↗

Next Generation Fast RF Interlock Module and ATCA Adapter for ILC High Availability RF Test Station Demonstration

High availability interlocks and controls are required for the ILC (International Linear Collider) L-Band high power RF stations. A new F3 (Fast Fault Finder) VME module has been developed to process both fast and slow interlocks using FPGA logic to detect the interlock trip excursions. This combination eliminates the need for separate PLC (Programmable Logic Controller) control of slow interlocks. Modules are chained together to accommodate as many inputs as needed. In the next phase of development the F3's will be ported to the new industry standard ATCA (Advanced Telecom Computing Architecture) crate (shelf) via a specially designed VME adapter module with IPMI (Intelligent Platform Management Interface). The goal is to demonstrate auto-failover and hot-swap for future partially redundant systems.

43 PARTICLE ACCELERATORS↗

An instrument design for the accurate determination of the electron beam location in the linac coherant light source undulator.

The linac coherent light source (LCLS), currently under design, requires accurate alignment between the electron beam and each undulator's magnetic centerline. A beam finder wire (BFW) instrument has been developed to provide beam location information that is used to move the undulators to their appropriate positions. A BFW instrument is mounted at each of the 33 magnets in the undulator section. Beam detection is achieved by electrons impacting two carbon fiber wires and then sensing the downstream radiation. The wires are mounted vertically and horizontally on a wire card similar to that of a traditional wire scanner instrument. The development of the BFW presents several design challenges due to the need for high accuracy of the wires locations and the need for removal of the wires during actual operation of the LCLS (30 microns repeatability is required for the wire locations). In this paper, we present the technical specification, design criteria, mechanical design, and results from prototype tests for the BFW.

43 PARTICLE ACCELERATORS↗

Isotopic Fractionation and Kinetic Isotope Effects of a Purified Bacterial Nitric Oxide Reductase (NOR)

Nitrous oxide (N 2 O) is a serious concern due to its role in global warming and ozone destruction. Agricultural practices account for ~80% of all anthropogenic N 2 O produced in the US, due in large part to the stimulation of microbial denitrification. Stable isotopes are uniquely suited to examine both microbial N 2 O sources and the mechanism of N 2 O biosynthesis through the use of 2 Site Preference (δ 15 N SP ; the difference in δ 15 N between the central and outer N atoms in N 2 O) and kinetic isotope effects (KIEs), respectively. Using trace gas isotope ratio mass spectrometry (TG-IRMS), we determined the δ 15 N, δ 15 N α , δ 15 N β , and δ 18 O of N 2 O produced by a purified cytochrome c nitric oxide reductase (cNOR) from Paracoccus denitrificans. We also calculated δ 15 N SP , the KIEs, and associated isotopic enrichment factors (ε) for N bulk , N α , and N β . A normal isotope effect was observed for bulk 15 N, with a KIE value of 1.0086 ± 0.0009 (ε = -8.6 ± 0.9‰). The isotope effects for both 15 N α and 15 N β were also normal, with position-specific KIEs of 1.0072 ± 0.0010 (ε = -7.2 ± 1.0‰) and 1.0100 ± 0.0010 (ε = -9.9 ± 1.0‰), respectively, and δ 15 N SP values ranged from 0.5 to 8.7‰ with no significant trend as the reaction proceeded. Values of δ 18 O increased with N 2 O production (slope of δ 18 O against [-flnf/(1-f)] = -19.9 ± 1.9‰). We present implications for the mechanism of N 2 O production from cNOR based on our data.

Rivett, Elise D. [Michigan State Univ., East Lansi↗

Monte-Carlo Analysis of the Accuracy of a Novel Thomson Scattering Lidar Approach for Determination of the Electron Temperature in Fusion Plasmas

The accuracy of a novel Thomson scattering lidar approach for determination of the electron temperature in fusion plasmas is investigated by statistical Monte-Carlo modeling of the measurement process. The approach is based on the unambiguous temperature dependence of the ratio of the signal powers of two wide Thomson scattering spectral regions. It is shown that the accuracy of the novel approach is comparable with those of the center-of-mass wavelength approach we have developed recently and the commonly used fitting approach. Thus, such an approach would be advantageous by the possibility of using essentially simpler hardware consisting of only two receiving spectral channels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Software Tool for Processing the Displacement Time Series Extracted from Raw Radar Data

The application of high-resolution radar waveform and interferometric principles recently led to the development of a microwave interferometer, suitable to simultaneously measuring the (static or dynamic) deflection of several points on a large structure. From the technical standpoint, the sensor is a Stepped Frequency Continuous Wave (SF-CW), coherent radar, operating in the K{sub u} frequency band.In the paper, the main procedures adopted to extract the deflection time series from raw radar data and to assess the quality of data are addressed, and the MATLAB toolbox developed is described. Subsequently, other functions implemented in the software tool (e.g. evaluation of the spectral matrix of the deflection time-histories, identification of natural frequencies and operational mode shapes evaluation) are described and the application to data recorded on full-scale bridges is exemplified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements.Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken.This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Innovative Transponder-Based Interferometric Radar for Vibration Measurements

Ground-based radar interferometry has recently emerged as an innovative technology of remote sensing, able to accurately measure the static or dynamic displacement of several points of a structure. This technique in the last couple of years has been applied to different types of structures, such as bridges, towers and chimneys. This paper presents a prototype system developed by IDS, originally aimed at measuring the structural vibrations of helicopter rotor blades, based on an interferometric technique and constituted by combination of a radar sensor and a series of transponders installed on the target structure. The main advantages of this solution with respect to conventional interferometric radars, are related to the increased spatial resolution of the system, provided by the possibility to discriminate different transponders installed within the same resolution cell of the radar sensor, and to the reduction of the ambient noise (e.g. multi-path) on the radar measurement. The first feature allows the use of the microwave technology even on target areas with limited dimensions, such as industrial facilities, while the second aspect may extend the use of radar interferometric systems to complex scenarios, where multi-reflections are expected due to the presence of natural targets with high reflectivity to the radar signal. In the paper, the system and its major characteristics are first described; subsequently, application to the measurement of ambient vibration response of a lab set-up is summarized. Then the data acquired on a rotating mock-up are reported and analyzed to identify natural frequencies and mode shapes of the investigated structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of rapid, continuous calibration techniques and implementation as a prototype system for civil engineering materials evaluation

Until recently, civil engineering material calibration data could only be obtained from material sample cores or via time consuming, stationary calibration measurements in a limited number of locations. Calibration data are used to determine material propagation velocities of electromagnetic waves in test materials for use in layer thickness measurements and subsurface imaging. Limitations these calibration methods impose have been a significant impediment to broader use of nondestructive evaluation methods such as ground-penetrating radar (GPR). In 2006, a new rapid, continuous calibration approach was designed using simulation software to address these measurement limitations during a Federal Highway Administration (FHWA) research and development effort. This continuous calibration method combines a digitally-synthesized step-frequency (SF)-GPR array and a data collection protocol sequence for the common midpoint (CMP) method. Modeling and laboratory test results for various data collection protocols and materials are presented in this paper. The continuous-CMP concept was finally implemented for FHWA in a prototype demonstration system called the Advanced Pavement Evaluation (APE) system in 2009. Data from the continuous-CMP protocol is processed using a semblance/coherency analysis to determine material propagation velocities. Continuously calibrated pavement thicknesses measured with the APE system in 2009 are presented. This method is efficient, accurate, and cost-effective.

42 ENGINEERING↗

Overall View of the JEM-EUSO Instruments

JEM-EUSO mission with a large and wide-angle telescope mounted on ISS has been planned to open up 'particle astronomy' through the investigation of extreme-energy cosmic rays by detecting fluorescent and Cherenkov photons by air showers developed in the earth's atmosphere. The JEM-EUSO telescope consists of optical Fresnel lenses with a diameter of about 2.5 m, 300 k channels of MAPMT, frontend readout electronics, trigger electronics, and system electronics. An infrared camera and a LIDAR system will be used to monitor the earth's atmosphere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light scattering under conditions of nonstationary electromagnetically induced transparency

The propagation of probe radiation pulses in ultracold atomic ensembles is studied theoretically under conditions of electromagnetically induced transparency. The pulse 'stopping' process is considered which takes place upon nonadiabatic switching off and subsequent switching on the control field. We analysed the formation of an inverted recovered probe radiation pulse, i.e. the pulse propagating in the direction opposite to the propagation direction before the pulse stopping. Based on this analysis, a scheme is proposed for lidar probing atomic or molecular clouds in which the probe pulse penetrates into a cloud over the specified depth, while information on the cloud state is obtained from the parameters of the inverted pulse. Calculations are performed for an ensemble of {sup 87}Rb atoms. (fifth seminar in memory of d.n. klyshko)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the possibility of using aerosol backscattering in the adaptive loop of atmospheric optical systems

The mean received power of partially coherent cw laser radiation scattered in the atmosphere is calculated depending on the spatial coherence of the initial field and the angular divergence of a laser beam formed by a circular output aperture. It is shown that due to diffraction on the circular aperture, the dependence of the mean radiation power on the divergence angle is nonmonotonic and has a maximum. The divergence angle corresponding to this maximum is determined by the spatial coherence of the initial field. The possibility of controlling the adaptive loop of the laser system by means of signals backscattered in the atmosphere is discussed. (lidars)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of the wind velocity profile by the intensity fluctuations of a scattered wave in a receiving telescope

The problem of the wind velocity profile reconstruction from random intensity fluctuations of a laser beam diffusely scattered by a screen and received by a telescope is considered. Expressions for a spatiotemporal correlation function and spectrum of weak intensity fluctuations of the reflected beam are presented. An algorithm is proposed for the reconstruction of the profile and direction of the wind velocity from the intensity fluctuation spectra of reflected radiation received by the telescope. The efficiency of the algorithm is confirmed by the results of numerical experiments. (lidars)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Remote laser detection of natural gas leakages from pipelines

A differential absorption lidar based on a tunable TEA CO{sub 2} laser emitting at 42 lines of the 'hot' 01{sup 1}1 - 11{sup 1}0 band in the range from 10.9 to 11.4 {mu}m is developed for detecting natural gas leakages from oil pipelines by measuring the ethane content in the atmosphere. The ethane detection sensitivity is 0.9 ppm km. The presence of methane does not distort the measurement results. The developed lidar can detect the natural gas leakage from kilometre heights at the flying velocities up to 200 km h{sup -1} and a probe pulse repetition rate of 5 Hz. (laser applications and other topics in quantum electronics)