Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FRAMING CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Precision of FLEET Velocimetry Using High-Speed CMOS Camera Systems

Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 microseconds, precisions of 0.5 meters per second in air and 0.2 meters per second in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision HighSpeed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

Peters, Christopher J.↗

Optimised Post-Exposure Image Sharpening Code for L3-CCD Detectors

As light from celestial bodies traverses Earth's atmosphere, the wavefronts are distorted by atmospheric turbulence, thereby lowering the angular resolution of ground-based imaging. Rapid time-series imaging enables Post-Exposure Image Sharpening (PEIS) techniques, which employ shift-and-add frame registration to remove the tip-tilt component of the wavefront error--as well as telescope wobble, thus benefiting all observations. Further resolution gains are possible by selecting only frames with the best instantaneous seeing--a technique sometimes calling 'Lucky Imaging'. We implemented these techniques in the 1990s, with the TRIFFID imaging photon-counting camera, and its associated data reduction software. The software was originally written for time-tagged photon-list data formats, recorded by detectors such as the MAMA. This paper describes our deep re-structuring of the software to handle the 2-d FITS images produced by Low Light Level CCD (L3-CCD) cameras, which have sufficient time-series resolution (>30 Hz) for PEIS. As before, our code can perform straight frame co-addition, use composite reference stars, perform PEIS under several different algorithms to determine the tip/tilt shifts, store 'quality' and shift information for each frame, perform frame selection, and generate exposure-maps for photometric correction. In addition, new code modules apply all 'static' calibrations (bias subtraction, dark subtraction and flat-fielding) to the frames immediately prior to the other algorithms. A unique feature of our PEIS/Lucky Imaging code is the use of bidirectional wiener-filtering. Coupled with the far higher sensitivity of the L3-CCD over the previous TRIFFID detectors, much fainter reference stars and much narrower time windows can be used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced orbital gyrocompassing by the optical flow sensed by an Earth-pointing camera

A new method for improving the orbital gyrocompassing process involving the attitude angle estimation of an earth-pointing satellite in low-Earth orbit uses an electro-optical sensor for direct measurement of the satellite azimuth angle. Simulations have shown that this additional measurement drastically reduces the estimator convergence time, especially when the sun sensor is rendered ineffective, e.g., by high solar elevations. The azimuth-sensing method is based on estimation of the image shift between successive picture frames of an on-board, Earth-pointing, charge-coupled device (CCD) full-matrix camera. The shift-estimation algorithm is based on minimizing a cost function which expresses mean-squared differences in brightness patterns of selected areas of the two frames. An extensive evaluation program with a computer-controlled 2-axis light table and actual satellite images has demonstrated high robustness for a wide range of variation of parameters including image texture content; camera focal length; sampling rate; and number of pixels processed. It was shown to be possible to estimate the azimuth angle within 0.1-0.2 degrees, for a suitably chosen parameter set.

Topaz, Leora↗

Speaking Volumes About 3-D

In 1999, Genex submitted a proposal to Stennis Space Center for a volumetric 3-D display technique that would provide multiple users with a 360-degree perspective to simultaneously view and analyze 3-D data. The futuristic capabilities of the VolumeViewer(R) have offered tremendous benefits to commercial users in the fields of medicine and surgery, air traffic control, pilot training and education, computer-aided design/computer-aided manufacturing, and military/battlefield management. The technology has also helped NASA to better analyze and assess the various data collected by its satellite and spacecraft sensors. Genex capitalized on its success with Stennis by introducing two separate products to the commercial market that incorporate key elements of the 3-D display technology designed under an SBIR contract. The company Rainbow 3D(R) imaging camera is a novel, three-dimensional surface profile measurement system that can obtain a full-frame 3-D image in less than 1 second. The third product is the 360-degree OmniEye(R) video system. Ideal for intrusion detection, surveillance, and situation management, this unique camera system offers a continuous, panoramic view of a scene in real time.

Source record↗

High-Speed Edge-Detecting Line Scan Smart Camera

A high-speed edge-detecting line scan smart camera was developed. The camera is designed to operate as a component in a NASA Glenn Research Center developed inlet shock detection system. The inlet shock is detected by projecting a laser sheet through the airflow. The shock within the airflow is the densest part and refracts the laser sheet the most in its vicinity, leaving a dark spot or shadowgraph. These spots show up as a dip or negative peak within the pixel intensity profile of an image of the projected laser sheet. The smart camera acquires and processes in real-time the linear image containing the shock shadowgraph and outputting the shock location. Previously a high-speed camera and personal computer would perform the image capture and processing to determine the shock location. This innovation consists of a linear image sensor, analog signal processing circuit, and a digital circuit that provides a numerical digital output of the shock or negative edge location. The smart camera is capable of capturing and processing linear images at over 1,000 frames per second. The edges are identified as numeric pixel values within the linear array of pixels, and the edge location information can be sent out from the circuit in a variety of ways, such as by using a microcontroller and onboard or external digital interface to include serial data such as RS-232/485, USB, Ethernet, or CAN BUS; parallel digital data; or an analog signal. The smart camera system can be integrated into a small package with a relatively small number of parts, reducing size and increasing reliability over the previous imaging system..

Prokop, Norman F.↗

Aerial Videography From Locally Launched Rockets

A method of quickly collecting digital imagery of ground areas from video cameras carried aboard locally launched rockets has been developed. The method can be used, for example, to record rare or episodic events or to gather image data to guide decisions regarding treatment of agricultural fields or fighting wildfires. The method involves acquisition and digitization of a video frame at a known time along with information on the position and orientation of the rocket and camera at that time. The position and orientation data are obtained by use of a Global Positioning System receiver and a digital magnetic compass carried aboard the rocket. These data are radioed to a ground station, where they are processed, by a real-time algorithm, into georeferenced position and orientation data. The algorithm also generates a file of transformation parameters that account for the variation of image magnification and distortion associated with the position and orientation of the camera relative to the ground scene depicted in the image. As the altitude, horizontal position, and orientation of the rocket change between image frames, the algorithm calculates the corresponding new georeferenced position and orientation data and the associated transformation parameters. The output imagery can be rendered in any of a variety of formats. The figure presents an example of one such format.

Lyle, Stacey D.↗

Interaction Between Liquid Silver and Graphene-Coated SiC Substrate

Wettability between liquid Ag and graphene-coated SiC single crystal has been investigated by dispensed drop method at T = 970 °C under vacuum accompanied with subsecond recording of the drop/substrate images (100 frames per second) by high-speed high-resolution CCD camera. Non-contact heating method coupled with capillary purification of the Ag drop procedure has been applied. Scanning electron microscopy combined with EDS analysis and scanning probe microscopy combined with Raman spectroscopy techniques has been utilized for microstructure and surface characterization of samples before and after high-temperature wetting tests. Immediately after its detachment from the capillary, the Ag drop showed non-wetting behavior (θ > 90°) forming a high contact angle of θ = 114°. Surface characterization of the drop surface after wettability tests evidenced the presence of graphene and Si transferred from the substrate to the top of Ag drop. These findings suggest chemical interaction phenomena occurring at the interface. Locally, an intimate contact between liquid Ag and SiC substrate was allowed by the appearance of discontinuities in the graphene layer basically produced by thermomechanical stress. Local dissolution of carbon into liquid Ag and its reorganization (by segregation, nucleation and growth) as secondary graphene layer at the Ag surface was also observed.

36 MATERIALS SCIENCE↗

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A RESOLVED MAP OF THE INFRARED EXCESS IN A LYMAN BREAK GALAXY AT z = 3

We have observed the dust continuum of 10 z = 3.1 Lyman break galaxies with the Atacama Large Millimeter/submillimeter Array at ∼450 mas resolution in Band 7. We detect and resolve the 870 μ m emission in one of the targets with a flux density of S {sub 870} = 192 ± 57 μ Jy, and measure a stacked 3 σ signal of S {sub 870} = 67 ± 23 μ Jy for the remaining nine. The total infrared luminosities are L {sub 8–1000} = (8.4 ± 2.3) × 10{sup 10} L {sub ⊙} for the detection and L {sub 8–1000} = (2.9 ± 0.9) × 10{sup 10} L {sub ⊙} for the stack. With Hubble Space Telescope Advanced Camera for Surveys I -band imaging we map the rest-frame UV emission on the same scale as the dust, effectively resolving the “infrared excess” (IRX = L {sub FIR}/ L {sub UV}) in a normal galaxy at z = 3. Integrated over the galaxy we measure IRX = 0.56 ± 0.15, and the galaxy-averaged UV slope is β = −1.25 ± 0.03. This puts the galaxy a factor of ∼10 below the IRX– β relation for local starburst nuclei of Meurer et al. However, IRX varies by more than a factor of 3 across the galaxy, and we conclude that the complex relative morphology of the dust relative to UV emission is largely responsible for the scatter in the IRX– β relation at high- z . A naive application of a Meurer-like dust correction based on the UV slope would dramatically overestimate the total star formation rate, and our results support growing evidence that when integrated over the galaxy, the typical conditions in high- z star-forming galaxies are not analogous to those in the local starburst nuclei used to establish the Meurer relation.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensory, Decision and Control Systems: April to July 1966

The quarter reported here for the NASA contract, and the longer period reported for the Air Force contract, saw the development of two system concepts for the transmission of video data from a remote location to Earth. In the simpler system, a stereoscopic outline together with other data such as reflectance and possibly the texture of objects will be transmitted to Earth. The objects considered are those larger than a predetermined size and within a predetermined range. From the stereoscopic outlines presented to the operator on Earth he will decide what objects he would like pictured in full TV frames and order these transmitted. In the more elaborate system, TV cameras will be carried on a vehicle and the direction in which the vehicle moves will be chosen by an onboard decision computer. Perceptual decisions may also be made to identify objects whose characteristics have been reported to Earth and whose value to the Earth observer has been communicated back to the perceptual computer. The assembly of cameras, perceptual computer, decision computer and vehicle is called a robot. Photosensors for this robot are television cameras, the first models of which have been tested under computer control. A model of both the perceptual computer and the decision computer has been simulated. It consists of 12 modules, each of which makes an initial guess as to what the response to incoming data should be. Each takes the data from all other modules and combines it in a nonlinear fashion with the data coming directly into it to arrive at a mixed guess as to what act should be performed. When 60% of the modules vote 0. 5 probability for one act, that act is performed. Convergence to a satisfactory decision took from 5 to 25 time steps. The model of the frog's retina previously reported is here extended to that part of the brain, called the tectum, where the frog begins to respond to objects detected by the retina.

Control system↗

Real-time video-image analysis

Digitizer and storage system allow rapid random access to video data by computer. RAPID (random-access picture digitizer) uses two commercially-available, charge-injection, solid-state TV cameras as sensors. It can continuously update its memory with each frame of video signal, or it can hold given frame in memory. In either mode, it generates composite video output signal representing digitized image in memory.

Eskenazi, R.↗

High-Speed PLIF Imaging of Hypersonic Transition over Discrete Cylindrical Roughness

In two separate test entries, advanced laser-based instrumentation has been developed and applied to visualize the hypersonic flow over cylindrical protrusions on a flat plate. Upstream of these trips, trace quantities of nitric oxide (NO) were seeded into the boundary layer. The protuberances were sized to force laminar-to-turbulent boundary layer transition. In the first test, a 10-Hz nitric oxide planar laser-induced fluorescence (NO PLIF) flow visualization system was used to provide wide-field-of-view, high-resolution images of the flowfield. The images had sub-microsecond time resolution. However these images, obtained with a time separation of 0.1 sec, were uncorrelated with each other. Fluorescent oil-flow visualizations were also obtained during this test. In the second experiment, a laser and camera system capable of acquiring NO PLIF measurements at 1 million frames per second (1 MHz) was used. This system had lower spatial resolution, and a smaller field of view, but the images were time correlated so that the development of the flow structures could be observed in time.

Danehy, P. M.↗

Autonomous Exploration for Gathering Increased Science

The Autonomous Exploration for Gathering Increased Science System (AEGIS) provides automated targeting for remote sensing instruments on the Mars Exploration Rover (MER) mission, which at the time of this reporting has had two rovers exploring the surface of Mars (see figure). Currently, targets for rover remote-sensing instruments must be selected manually based on imagery already on the ground with the operations team. AEGIS enables the rover flight software to analyze imagery onboard in order to autonomously select and sequence targeted remote-sensing observations in an opportunistic fashion. In particular, this technology will be used to automatically acquire sub-framed, high-resolution, targeted images taken with the MER panoramic cameras. This software provides: 1) Automatic detection of terrain features in rover camera images, 2) Feature extraction for detected terrain targets, 3) Prioritization of terrain targets based on a scientist target feature set, and 4) Automated re-targeting of rover remote-sensing instruments at the highest priority target.

Bornstein, Benjamin J.↗

Considerations on ODR beam-size monitoring for gamma = 1000 beams

We discuss the feasibility of monitoring the beam size of {gamma} = 1000 beams with 3000 times more charge in a video frame time and with a more sensitive 12- to 16-bit camera than were used in the previous electron beam studies at 7 GeV at the Advanced Photon Source. Such a beam would be generated at Fermilab in a new facility in the coming years. Numerical integrations of our base model show beam size sensitivity for {+-} 20% level changes at 200- and 400-{micro}m base beam sizes. We also evaluated impact parameters of 5 {sigma}{sub y} and 12 {sigma}{sub y} for both 800-nm and 10-{micro}m observation wavelengths. The latter examples are related to a proposal to apply the technique to an {approx}0.98 TeV proton beam, and this study shows there are trades on photon intensity and beam size sensitivity to be considered at such gammas. In addition, we report on first results at {gamma} = 1800 on a superconducting rf linac.

43 PARTICLE ACCELERATORS↗

ACTIVE AND PASSIVE GALAXIES AT z {approx} 2: REST-FRAME OPTICAL MORPHOLOGIES WITH WFC3

We use the high angular resolution in the near-infrared of the Wide Field Camera 3 (WFC3) on the Hubble Space Telescope to determine YHVz color-color-selection criteria to identify and characterize 1.5 < z < 3.5 galaxies in the Hubble Ultra Deep Field 2009 (HUDF09) and Early Release Science (GOODS-South) fields. The WFC3 NIR images reveal galaxies at these redshifts that were undetected in the rest-frame UV HUDF/GOODS images, as well as true centers and regular disks in galaxies classified as highly irregular in rest-frame UV light. Across the 1.5 < z < 2.15 redshift range, regular disks are unveiled in the WFC3 images of {approx}25% of both intermediate and high mass galaxies, i.e., above 10{sup 10} M{sub Sun }. Meanwhile, galaxies maintaining diffuse and/or irregular morphologies in the rest-frame optical light-i.e., not yet dynamically settled-at these epochs are almost entirely restricted to masses below 10{sup 11} M{sub Sun }. In contrast at 2.25 < z < 3.5 these diffuse and/or irregular structures overwhelmingly dominate the morphological mix in both the intermediate and high mass regimes, while no regular disks, and only a small fraction ({approx}25%) of smooth spheroids, are evident above 10{sup 11} M{sub Sun }. Strikingly, by 1.5 < z < 2.25 roughly two out of every three galaxies at the highest masses are spheroids. In our small sample, the fraction of star-forming galaxies at these mass scales decreases concurrently from {approx}60% to {approx}5%. If confirmed, this indicates that z {approx} 2 is the epoch of both the morphological transformation and quenching of star formation which assemble the first substantial population of massive ellipticals.

79 ASTRONOMY AND ASTROPHYSICS↗

Summary Report on Liquid-Liquid Contactor Scoping Experiments and Validation Test Case Definition

This report presents an overview of a set of wide ranging experiments that was conducted during the first half of FY12 using the capability of the Contactor Electrical Resistance Tomography (CERT) Facility. This facility includes the capability for multiphase measurements of flow in liquid–liquid contactors using ERT as well as high-speed imaging with the current test focus on an instrumented engineering-scale annular centrifugal contactor having a 5 inch rotor (CINC-V5). The purpose of the efforts during this current FY are to explore a range of flow conditions for multiphase operation to gain broad insight into observable trends and quantities after which detailed measurements will be made for specific controlled test conditions to provide data for validation of advanced computational fluid dynamics models which are being developed under a separate work package (FT-12AN030901). In addition to the Redlake X5plus camera, a Redlake MotionPro Y7 camera was also available on loan from another research group at Argonne. The Y7 is capable of grayscale imaging at 7500 frames per second at full resolution (1920×1080) and has excellent light sensitivity (can be used for time-resolved particle image velocimetry (PIV)). This camera was used for the bubble imaging described in Section 2.3. Imaging at the bubble scale was done using a Infinity K1 CentriMax lens with an MX-4 objective attachment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A 5-18 micron array camera for high-background astronomical imaging

A new infrared array camera system using a Hughes/SBRC 58 x 62 pixel hybrid Si:Ga array detector has been successfully applied to high-background 5-18-micron astronomical imaging observations. The off-axis reflective optical system minimizes thermal background loading and produces diffraction-limited images with negligible spatial distortion. The noise equivalent flux density (NEFD) of the camera at 10 microns on the 3.0-m NASA/Infrared Telescope Facility with broadband interference filters and 0.26 arcsec pixel is NEFD = 0.01 Jy/sq rt min per pixel (1sigma), and it operates at a frame rate of 30 Hz with no compromise in observational efficiency. The electronic and optical design of the camera, its photometric characteristics, examples of observational results, and techniques for successful array imaging in a high- background astronomical application are discussed.

Gezari, Daniel Y.↗

Measurement of inkjet first-drop behavior using a high-speed camera

Drop-on-demand inkjet printing has been used as a manufacturing tool for printed electronics, and it has several advantages since a droplet of an exact amount can be deposited on an exact location. Such technology requires positioning the inkjet head on the printing location without jetting, so a jetting pause (non-jetting) idle time is required. Nevertheless, the behavior of the first few drops after the non-jetting pause time is well known to be possibly different from that which occurs in the steady state. The abnormal behavior of the first few drops may result in serious problems regarding printing quality. Therefore, a proper evaluation of a first-droplet failure has become important for the inkjet industry. To this end, in this study, we propose the use of a high-speed camera to evaluate first-drop dissimilarity. For this purpose, the image acquisition frame rate was determined to be an integer multiple of the jetting frequency, and in this manner, we can directly compare the droplet locations of each drop in order to characterize the first-drop behavior. Finally, we evaluate the effect of a sub-driving voltage during the non-jetting pause time to effectively suppress the first-drop dissimilarity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗