Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

A Novel Technique for Inferior Vena Cava Filter Extraction

Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The origin, transport, and evolution of ash in engine particulate filters

Engine particulate filters have been widely applied across the world to control engine exhaust particulate matter (or particulate number) emissions. With increasing vehicle mileage, ash accumulation deteriorates vehicle fuel economy and complicates on-board control. Extending filter service life with ash loading has significant economic and environmental impacts. Many studies have been conducted in characterizing ash accumulation and evaluating its impacts on filter performance. However, comprehensive reviews covering all the key issues in the field are rather rare. This paper reviews the extensive prior research on filter ash, and not only summarizes the experimental observations but also elucidates the fundamental mechanisms. The review covers the areas of ash origin, accumulation, transport, evolution, and artificial acceleration methods. The previously reported data of ash properties is compiled and analyzed. Furthermore, the advantages and disadvantages of ash acceleration approaches are also discussed in detail. Based on the cumulative understanding, a few potential ways to improve ash management are discussed in this paper. In summary, the present work systematically reviews the previous observations and understanding of ash aging in particulate filters and identifies areas that need further research, which can be useful guidance for future studies.

42 ENGINEERING↗

Verification of sub-grid filtered drag models for gas-particle fluidized beds with immersed cylinder arrays

The accuracy of coarse-grid multiphase CFD simulations of fluidized beds may be improved via the inclusion of filtered constitutive models. In our previous study (Sarkar et al., Chem. Eng. Sci., 104, 399-412), we developed such a set of filtered drag relationships for beds with immersed arrays of cooling tubes. Verification of these filtered drag models is addressed in this work. Predictions from coarse-grid simulations with the sub-grid filtered corrections are compared against accurate, highly-resolved simulations of full-scale turbulent and bubbling fluidized beds. The filtered drag models offer a computationally efficient yet accurate alternative for obtaining macroscopic predictions, but the spatial resolution of meso-scale clustering heterogeneities is sacrificed.

42 ENGINEERING↗

Nonlocal Means Denoising of Self-Gated and k-Space Sorted 4-Dimensional Magnetic Resonance Imaging Using Block-Matching and 3-Dimensional Filtering: Implications for Pancreatic Tumor Registration and Segmentation

Purpose: To denoise self-gated k-space sorted 4-dimensional magnetic resonance imaging (SG-KS-4D-MRI) by applying a nonlocal means denoising filter, block-matching and 3-dimensional filtering (BM3D), to test its impact on the accuracy of 4D image deformable registration and automated tumor segmentation for pancreatic cancer patients. Methods and Materials: Nine patients with pancreatic cancer and abdominal SG-KS-4D-MRI were included in the study. Block-matching and 3D filtering was adapted to search in the axial slices/frames adjacent to the reference image patch in the spatial and temporal domains. The patches with high similarity to the reference patch were used to collectively denoise the 4D-MRI image. The pancreas tumor was manually contoured on the first end-of-exhalation phase for both the raw and the denoised 4D-MRI. B-spline deformable registration was applied to the subsequent phases for contour propagation. The consistency of tumor volume defined by the standard deviation of gross tumor volumes from 10 breathing phases (σ-GTV), tumor motion trajectories in 3 cardinal motion planes, 4D-MRI imaging noise, and image contrast-to-noise ratio were compared between the raw and denoised groups. Results: Block-matching and 3D filtering visually and quantitatively reduced image noise by 52% and improved image contrast-to-noise ratio by 56%, without compromising soft tissue edge definitions. Automatic tumor segmentation is statistically more consistent on the denoised 4D-MRI (σ-GTV = 0.6 cm{sup 3}) than on the raw 4D-MRI (σ-GTV = 0.8 cm{sup 3}). Tumor end-of-exhalation location is also more reproducible on the denoised 4D-MRI than on the raw 4D-MRI in all 3 cardinal motion planes. Conclusions: Block-matching and 3D filtering can significantly reduce random image noise while maintaining structural features in the SG-KS-4D-MRI datasets. In this study of pancreatic tumor segmentation, automatic segmentation of GTV in the registered image sets is shown to be more consistent on the denoised 4D-MRI than on the raw 4D-MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impacts of engine lubrication oil-derived ash on soot oxidative reactivity on a catalytic gasoline particulate filter

Characterizing soot oxidation kinetics is crucial for understanding how gasoline particulate filters (GPFs) perform both in terms of filtration efficiency and pressure drop. The most common method for measuring soot oxidative reactivity is thermogravimetric analysis (TGA). Because TGA is an offline method, it may inaccurately predict how soot oxidizes on a GPF, especially if a catalytic washcoat is present that may enhance oxidation rates through surface interactions as the soot loads on the filter. In this work, a novel in-situ soot oxidative reactivity measurement method was developed. The method involved loading a catalytic GPF under high temperature conditions conducive to soot oxidation and measuring the filtration efficiency of 100 nm particles. A correlation was made between filtration efficiency and loaded soot mass on the filter to allow calculation of the soot oxidation rate. The method was evaluated in experiments using a 2.0 L gasoline direct injection (GDI) engine with three oils of varying additive packages, including an oil with a high zinc dialkyldithiophosphate (ZDDP) concentration, a non-additive, pure poly-alpha olefin (PAO) oil, and an oil with a high concentration of calcium sulfonate. Calculated specific soot oxidation rates ranged from ~0.06–0.6 min –1 and showed strong dependence on GPF inlet gas temperature and lubrication oil additive type. The results clearly demonstrated a catalytic effect of calcium-containing ash particles. Reactivity of soot produced by the engine running with the high calcium containing lubrication oil was increased. Similarly, the results indicated that the catalytic washcoat on the filter increased soot oxidation rates on-filter, especially at low soot loading. Conversely, the ZDDP oil additive exhibited a reactivity inhibiting effect, resulting in lower soot oxidation rates. Finally, this work represents the first known in-situ soot oxidative reactivity measurements on a GPF and elucidates the effect of lubrication oil additives and catalytic washcoat on oxidation rate.

42 ENGINEERING↗

A direct filter method for parameter estimation

Parameter estimation is an important research topic in data assimilation. In this paper, a novel parameter estimation method is introduced, where the parameter is considered as the state process in a nonlinear filtering problem and the state model that contains the parameter is used to construct a pseudo-observation. This approach is named the direct filter method since nonlinear filtering algorithms are used to estimate the parameter directly without estimating the state model as part of the solution in the nonlinear filtering problem. Numerical experiments are carried out to examine the effectiveness and accuracy of the direct filter method.

97 MATHEMATICS AND COMPUTING↗

XANES Speciation of P in Environmental Samples: An Assessment of Filter Media for on-Site Wastewater Treatment

X-ray absorption near edge structure (XANES) spectroscopy is a useful technique for characterization of chemical species of phosphorus in complex environmental samples. To develop and evaluate bed filters as sustainable on-site wastewater treatment solutions, our objective in this study was to determine the chemical forms of accumulated phosphorus in a selection of promising filter materials: Filtralite P, Filtra P, Polonite, Absol, blast furnace slag, and wollastonite. Full-scale operational wastewater-treatment systems were sampled and in addition, filter samples collected from laboratory studies provided access to additional media and complementary samples. Phosphorus species were characterized using phosphorus K-edge XANES spectroscopy, complemented by X-ray powder diffraction (XRPD) and attenuated total reflectance Fourier-transform infrared spectroscopy (ATR-FTIR). No systematic differences could be seen in the results between laboratory- and full-scale samples. All six filter media contained significant amounts of crystalline calcium phosphates. Some samples also contained amorphous calcium phosphate (>60% of total P in Absol). In Filtralite P and blast furnace slag, more than 35% of the accumulated phosphorus was associated with Fe or Al. Both the power and shortcomings of XANES analysis for characterizing P species in these filter media are discussed.

36 MATERIALS SCIENCE↗

Experimental study on the role of a resistor in the filter of Hall thrusters

A filter is a mainly component applied to reduce the discharge current low frequency oscillation in the range of 10-100 kHz. The only form of the filter in actual use involves RLC networks, whose design originates from the 1970s, but even now, researchers are unaware of the actual primary motivations for the resistor's presence [S. Barral et al., AIAA Paper 2008-4632, 2008]. Therefore, the role of the resistor in the filter is experimentally studied and discussed through the analysis of control system and electric circuit theory. Experimental results and analysis indicate that the presence of a resistor makes the filter having the phase compensation function. The proper phase-angle and amplitude provided by the filter would increase or decrease the ion mobility and be helpful to balance the ion production in the discharge channel and then to decrease the fluctuation of the plasma density and lower the low frequency oscillation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chalcogenide Photonic Crystal Filters For Optical Communication

A proper arrangement of photonic crystal waveguide and a point defect cavity gives an important application of photonic filter device in optical communications. We have studied a narrow band filter and a channel drop filter device using 2-D photonic crystal with square lattice structure. A narrow band filter is applied to select a narrow frequency band signal from incoming light, while a channel drop filter is used to drop a particular frequency signal from incoming light. Chalcogenide As{sub 2}S{sub 3} is compared with conventional Si material regarding applications as feasible material for optical devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Soft x-ray array system with variable filters for the DIII-D tokamak

Recent upgrades to the soft x-ray (SXR) array system on the DIII-D tokamak are described. The system consists of two 32-channel arrays at one toroidal location and three toroidally distributed 12-channel arrays. The 32-channel arrays have been completely rebuilt to allow the switching of SXR filters without breaking vacuum. The 12-channel arrays have had upgrades performed to detectors, view slits, and data acquisition. Absolute extreme ultraviolet (AXUV) photodiodes are used as detectors in all arrays, allowing detection of photons ranging in energy from 2 eV to 10 keV. In the fixed-filter arrays, 127 {mu}m Be filters are used. In the variable-filter arrays, filter wheels are used to switch between five different possible pinhole/filter combinations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of sheath characteristics in a double plasma device with a negatively biased separating grid and a magnetic filter field

A double plasma device has two regions: Source region and target region. These two regions are divided by a magnetic filter field. A grid is placed coplanar to the magnetic filter. To study the sheath structure in the target region, a metallic plate is placed at the center, which can be biased with respect to the chamber (ground) potential. Plasma is created in the source region by filament discharge technique. Plasma diffusing from the source region to the target region is subjected to the magnetic filter field and also an electric field applied on the grid. Plasma thus obtained in the target region forms a sheath on the biased plate. The influence of both the magnetic filter field and the electric field, applied between the grid and the chamber wall, on the sheath structure formed on the biased plate is studied. It is found that the magnetic filter field and the electric field change the sheath structure in different ways.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A MEMS disk resonator-based band pass filter electrical equivalent circuit simulation

In this paper, coupled beam bandpass Disk filter is designed for 1 MHz bandwidth. Filter electrical equivalent circuit simulation is performed using circuit simulators. Important filter parameters such as insertion loss, shape factor and Q factor aresetimated using coventorware simulation. Disk resonator based radial contour mode filter provides 1.5 MHz bandwidth and unloaded quality factor of resonator and filter as 233480, 21797 respectively. From the simulation result it’s found that insertion loss minimum is 151.49 dB, insertion loss maximum is 213.94 dB, and 40 dB shape factor is 4.17.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A digital matched filter for reverse time chaos

The use of reverse time chaos allows the realization of hardware chaotic systems that can operate at speeds equivalent to existing state of the art while requiring significantly less complex circuitry. Matched filter decoding is possible for the reverse time system since it exhibits a closed form solution formed partially by a linear basis pulse. Coefficients have been calculated and are used to realize the matched filter digitally as a finite impulse response filter. Numerical simulations confirm that this correctly implements a matched filter that can be used for detection of the chaotic signal. In addition, the direct form of the filter has been implemented in hardware description language and demonstrates performance in agreement with numerical results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thin-film X-ray filters on microstructured substrates and their thermophysical properties

It is shown that structured substrates having micron- or submicron-sized through holes and coated with an ultrathin organic film can be used for the fabrication of thin-film X-ray filters via direct growth of functional layers on a substrate by sputter deposition, without additional complex processing steps. An optimised process is considered for the fabrication of X-ray filters on support structures in the form of electroplated fine nickel grids and on track-etched polymer membranes with micron- and submicron-diameter through pores. ‘Optimisation’ is here taken to mean matching the sputter deposition conditions with the properties of substrates so as to avoid overheating. The filters in question are intended for both imaging and single-channel detectors operating in the soft X-ray and vacuum UV spectral regions, at wavelengths from 10 to 60 nm. Thermal calculations are presented for the heating of ultrathin layers of organic films and thin-film support substrates during the sputter deposition of aluminium or other functional materials. The paper discusses approaches for cooling thin-film composites during the sputter deposition process and the service of the filters in experiments and gives a brief overview of the works that utilised filters produced by the described technique on microstructured substrates, including orbital solar X-ray research in the framework of the CORONAS programme and laboratory laser plasma experiments. (invited paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Comprehensive Approach towards Multi-Objective EMI Filter Design Optimization in High-Frequency SiC-Based Motor Drives

With rapid penetration of high-frequency, highdensity power electronics into the industry, controlling the system generated EMI becomes one of the major design challenges. Designing practical optimized EMI filters require simultaneous consideration of multiple aspects - including electromagnetic couplings, magnetic materials, practical component parasitics and their impacts at high-frequencies, and also the overall manufacturing costs. The multi-dimensional nature of the problem often results in overcompensated designs that hurt the system efficiency and power density. This paper focuses on a comprehensive design platform (developed in MATLAB) towards designing high-density, optimized, highly efficient EMI filters by analyzing the generated noise spectrum and evaluating a vast array of potential solutions before outputting an optimized filter solution. The proposed tool includes database-based component selection, optimal topology selection, multistage filter design, overall optimization for volume, mass, cost and total loss. The proposed filter has been thoroughly evaluated in a PSIM simulation environment emulating the hardware in CRD300DA12EXM3, a 300kW three-phase inverter from Wolfspeed with an RL load representing a motor drive application. Furthermore, a 20kHz switching frequency is chosen and impacts of the motor high-frequency characteristics on the generated EMI noise spectrum of the overall system have been analyzed.

42 ENGINEERING↗

Novel Coaxial High Pass Filter Design for RF Applications

The complete design of a novel coaxial high pass filter is given analytically and numerically for high power RF applications. The coaxial structure consists of two hollow concentric cylinders with a septum located between them at a single azimuthal angle. This septum provides a good high pass filter characteristics and mechanically holds two hollow cylinders together. The attenuation slope in the stop band with this structure is much sharper than the existing filter configurations. This gives faster transition time from stop band to pass band One end of the coaxial structure is closed and the other end is used as an output port. Excitation port is placed on the side walls of the outside cylinder. The design procedure proposed in this paper has been implemented to obtain a filter configuration at the lower end of the UHF range. The new filter is simulated using 3D electromagnetic simulator, HFSS. It is then constructed and measured. Simulation results are compared with the measured results. Good agreement between simulated and measured results has been observed

42 ENGINEERING↗

Adaptive Extremum Seeking Control Based LCL Filter Resonant Frequency Online Estimation

The LCL filter has been widely used in the grid-tied inverter systems. However, the resonance of the LCL filter can reduce the system stability margin and the control performance. Moreover, the grid impedance variations can lead to the drift of the resonant frequency, which can further worsen the system robustness. Thus, it is important to know the actual resonant frequency of the LCL filter. In this letter, an adaptive extremum seeking control (AESC) based estimation scheme is proposed to estimate the resonant frequency of the LCL filter online. Further by injecting a high-frequency (HF) signal into the inverter output voltage, the AESC scheme can identify the extremum of the LCL filter amplitude response, i.e., resonant peak. The amplitude of injection signal is adaptive based on the inverter HF response, which can address the tradeoff between the dynamic response and inverter output current quality. Most importantly, compare to other method, the proposed scheme has very low computational complexity, which minimizes the burden to the normal inverter controller operation. Stability analysis is given in this letter, and experimental studies are conducted to validate the effectiveness of the proposed scheme.

42 ENGINEERING↗

Development of an irradiation method with lateral modulation of SOBP width using a cone-type filter for carbon ion beams

Passive irradiation methods deliver an extra dose to normal tissues upstream of the target tumor, while in dynamic irradiation methods, interplay effects between dynamic beam delivery and target motion induced by breathing or respiration distort the dose distributions. To solve the problems of those two irradiation methods, the authors have developed a new method that laterally modulates the spread-out Bragg peak (SOBP) width. By reducing scanning in the depth direction, they expect to reduce the interplay effects. They have examined this new irradiation method experimentally. In this system, they used a cone-type filter that consisted of 400 cones in a grid of 20 cones by 20 cones. There were five kinds of cones with different SOBP widths arranged on the frame two dimensionally to realize lateral SOBP modulation. To reduce the number of steps of cones, they used a wheel-type filter to make minipeaks. The scanning intensity was modulated for each SOBP width with a pair of scanning magnets. In this experiment, a stepwise dose distribution and spherical dose distribution of 60 mm in diameter were formed. The nonflatness of the stepwise dose distribution was 5.7% and that of the spherical dose distribution was 3.8%. A 2 mm misalignment of the cone-type filter resulted in a nonflatness of more than 5%. Lateral SOBP modulation with a cone-type filter and a scanned carbon ion beam successfully formed conformal dose distribution with nonflatness of 3.8% for the spherical case. The cone-type filter had to be set to within 1 mm accuracy to maintain nonflatness within 5%. This method will be useful to treat targets moving during breathing and targets in proximity to important organs.

61 RADIATION PROTECTION AND DOSIMETRY↗