Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FELs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Roadmap of ultrafast x-ray atomic and molecular physics

X-ray free-electron lasers (XFELs) and table-top sources of x-rays based upon high harmonic generation (HHG) have revolutionized the field of ultrafast x-ray atomic and molecular physics, largely due to an explosive growth in capabilities in the past decade. XFELs now provide unprecedented intensity (10 20 W cm -2 ) of x-rays at wavelengths down to ~1 Ångstrom, and HHG provides unprecedented time resolution (~50 attoseconds) and a correspondingly large coherent bandwidth at longer wavelengths. For context, timescales can be referenced to the Bohr orbital period in hydrogen atom of 150 attoseconds and the hydrogen-molecule vibrational period of 8 femtoseconds; wavelength scales can be referenced to the chemically significant carbon K-edge at a photon energy of ~280 eV (44 Ångstroms) and the bond length in methane of ~1 Ångstrom. With these modern x-ray sources one now has the ability to focus on individual atoms, even when embedded in a complex molecule, and view electronic and nuclear motion on their intrinsic scales (attoseconds and Ångstroms). These sources have enabled coherent diffractive imaging, where one can image non-crystalline objects in three dimensions on ultrafast timescales, potentially with atomic resolution. The unprecedented intensity available with XFELs has opened new fields of multiphoton and nonlinear x-ray physics where behavior of matter under extreme conditions can be explored. The unprecedented time resolution and pulse synchronization provided by HHG sources has kindled fundamental investigations of time delays in photoionization, charge migration in molecules, and dynamics near conical intersections that are foundational to AMO physics and chemistry. This roadmap coincides with the year when three new XFEL facilities, operating at Ångstrom wavelengths, opened for users (European XFEL, Swiss-FEL and PAL-FEL in Korea) almost doubling the present worldwide number of XFELs, and documents the remarkable progress in HHG capabilities since its discovery roughly 30 years ago, showcasing experiments in AMO physics and other applications. Here in this paper, we capture the perspectives of 17 leading groups and organize the contributions into four categories: ultrafast molecular dynamics, multidimensional x-ray spectroscopies; high-intensity x-ray phenomena; attosecond x-ray science.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cadmium zinc telluride pixel detectors for high-intensity x-ray imaging at free electron lasers

Here, this paper reports the first demonstration of high-intensity x-ray imaging using cadmium zinc telluride (CdZnTe) pixel detectors at a free electron laser (FEL). Prototype detectors were produced using the STFC large pixel detector (LPD) ASIC and sensors fabricated from a novel high-intensity-capable CdZnTe material produced by Redlen Technologies. Characterisation of the performance of this sensor material was completed at the Linac Coherent Light Source (LCLS) FEL. The detectors were operated at a frame rate of 1 MHz with 9.5 keV x-ray pulses delivered at a rate of 120 Hz. Measurements successfully demonstrated the linear response of the CdZnTe material to increasing numbers of x-rays up to a fluence of 8 GeV mm –2 per pulse, the limit of the dynamic range of the LPD ASIC.

47 OTHER INSTRUMENTATION↗

An x-ray regenerative amplifier free-electron laser using diamond pinhole mirrors

Abstract X-ray free-electron lasers (FELs) rely on SASE due to the lack of seed lasers and the difficulty in obtaining mirrors. Progress in diamond crystal Bragg mirrors enables the design of x-ray FEL oscillators. Regenerative amplifiers (RAFELs) are high gain/low- Q oscillators that out-couple most of the optical power. An x-ray RAFEL based on the LCLS-II at SLAC using a six-mirror resonator out-coupling 90% or more through a pinhole in the first downstream mirror is analyzed using the MINERVA simulation in the undulator and OPC for the resonator. Results show substantial powers at the fundamental (3.05 keV) and 3rd harmonic (9.15 keV).

47 OTHER INSTRUMENTATION↗

Analysis of the microbunching instability in a mid-energy electron linac

Microbunching instability usually exists in the linear accelerator (linac) of a free electron laser (FEL) facility. If it is not controlled effectively, the beam quality will be damaged seriously and the machine will not operate properly. In the electron linac of a soft X-ray FEL device, because the electron energy is not very high, the problem can become even more serious. As a typical example, the microbunching instability in the linac of the proposed Shanghai Soft X-ray Free Electron Laser facility (SXFEL) is investigated in detail by means of both analytical formulae and simulation tools. In the study, a new mechanism introducing random noise into the beam current profile as the beam passes through a chicane-type bunch compressor is proposed. The higher-order modes that appear in the simulations suggest that further improvement of the current theoretical model of the instability is needed.

43 PARTICLE ACCELERATORS↗

Operation of an Energy Recovery Linac with an Internal Target

Because an Energy Recovery Linac (ERL) decelerates and dumps the beam after at most a few passes, beam degradation in the interaction region that is orders of magnitude larger than in a storage ring is tolerable in such a device. As a consequence, some new types of Nuclear Physics experiments can be carried out. In 2016, an experiment (the DarkLight experiment) was installed in the Jefferson Lab FEL Driver ERL to test out this idea. The ERL had previously been used for FEL applications where high peak current and a large growth in energy spread was present. For the internal target, the machine setup required very small energy spread, and had to deal with large transverse emittance growth in the target. Additionally, the addition of a strong solenoid in the transport complicated the details of energy recovery. This presentation will describe how these new machine physics challenges were addressed.

Benson, S. V.↗

The Jefferson Lab free electron laser program

The development of superconducting radio frequency (SRF) accelerator technology for CEBAF's nuclear physics program set the stage for its application to a number of other efforts. We describe below the development of the a major advance in Free Electron Laser (FEL) Technology based on SRF linacs. The Jefferson Lab efforts achieved three orders of magnitude increase in the power delivered by FELs and firmly established the viability of energy recovering linac technology. We describe the details of the physics and engineering challenges addressed to accomplish this effort and then discuss some of the applications performed using the light source. We conclude with a look at the planned directions for the program in the future.

43 PARTICLE ACCELERATORS↗

Design of ePixM, a fully-depleted monolithic CMOS active pixel sensor for soft X-ray experiments at LCLS-II

The LCLS-II Free Electron Laser (FEL) will produce X-ray pulses with a repetition rate of up to 1 MHz and energies between 250 eV and 5 keV. Experiments conducted at LCLS-II will require 2D imaging detectors with a unique set of features, such as high-spatial resolution, low-noise performance, high-dynamic range and high-frame rates up to 1 MHz. We present the design of ePixM, a fully-depleted monolithic CMOS detector tailored for soft X-rays applications at high-repetition rates FEL. It consists of an array of 384×192 active pixel sensors, with a pixel size of 50×50 μm 2 and a total sensitive area of 2×1 cm 2 . ePixM has been designed in a 150 nm CMOS technology on high-resistivity substrate to achieve full depletion of the substrate. Each pixel includes a Charge Sensitive Amplifier (CSA) with gain auto-ranging capability and a noise-shaper performing Correlated Double Sampling (CDS). A novel technique named correlated pre-charging removes the excess noise introduced by the gain-switching mechanism. The performance of the design has been evaluated through post-layout simulations. The Equivalent Noise Charge (ENC) of 11.3 electrons enables single-photon detection at X-ray energies down to 250 eV, and the dynamic range exceeds 10 3 photons at 500 eV thanks to the auto-ranging circuitry.

47 OTHER INSTRUMENTATION↗

High harmonic generation in mixed XUV and NIR fields at a free-electron laser

Abstract We present the results of an experiment investigating the generation of high-order harmonics by a femtosecond near-infrared (NIR) laser pulse in the presence of an extreme ultraviolet (XUV) field provided by a free-electron laser (FEL), a process referred to as XUV-assisted high-order harmonic generation (HHG). Our experimental findings show that the XUV field can lead to a small enhancement in the harmonic yield when the XUV and NIR pulses overlap in time, while a strong decrease of the HHG yield and a red shift of the HHG spectrum is observed when the XUV precedes the NIR pulse. The latter observations are in qualitative agreement with model calculations that consider the effect of a decreased number of neutral emitters but are at odds with the predicted effect of the correspondingly increased ionization fraction on the phase matching. Our study demonstrates the technical feasibility of XUV-assisted HHG experiments at FELs, which may provide new avenues to investigate correlation-driven electron dynamics as well as novel ways to study and control propagation effects and phase matching in HHG.

47 OTHER INSTRUMENTATION↗

Energy density driven ultrafast electronic excitations in a cuprate superconductor

Controlling nonequilibrium dynamics in quantum materials requires ultrafast probes with spectral selectivity. We report femtosecond reflectivity measurements on the cuprate superconductor Bi 2⁢ Sr 2⁢ CaCu 2 ⁢O 8+𝛿 using free-electron laser extreme-ultraviolet (23.5–177 eV) and near-infrared (1.5 eV) pump pulses. EUV pulses access deep electronic states, while NIR light excites valence-band transitions. Despite these distinct channels, both schemes produce nearly identical dynamics: above 𝑇 𝑐 , excitations relax through fast (100–300 fs) and slower (1–5 ps) channels; below 𝑇 𝑐 , a delayed component signals quasiparticle recombination and condensate recovery. We find that when electronic excitations are involved, the ultrafast response is governed mainly by absorbed energy rather than by the microscopic nature of the excitation. In contrast, bosonic driving in the THz or midinfrared produces qualitatively different dynamics. By demonstrating that EUV excitation of a correlated superconductor yields macroscopic dynamics converging with those from optical pumping, this work defines a new experimental paradigm: FEL pulses at core-level energies provide a powerful means to probe and control nonequilibrium electronic states in quantum materials on their intrinsic femtosecond timescales. This establishes FEL-based EUV pumping as a new capability for ultrafast materials science, opening routes toward soft x-ray and attosecond studies of correlated dynamics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Equivalence between free-electron-laser oscillators and actively-mode-locked lasers: Detailed studies of temporal, spatiotemporal, and spectrotemporal dynamics

We show experimentally and numerically that free-electron-laser (FEL) oscillators behave in a very similar way to conventional actively-mode-locked lasers. This stems from the similar structures of their underlying Haus equations. A comparative study of the temporal evolutions of the pulse train shapes and spatiotemporal regimes is performed on a Nd:YVO{sub 4} laser and a storage-ring free-electron laser. Furthermore, since direct observations of time-resolved pulse shapes and spectra are more accessible on free-electron lasers, the analogy also potentially enables one to investigate mode-locked laser dynamics using existing FEL facilities.

43 PARTICLE ACCELERATORS↗

Resonant magnetic scattering with soft x-ray pulses from a free-electron laser operating at 1.59 nm

We report on a resonant magnetic scattering experiment using soft x-ray pulses generated from a free-electron laser (FEL). The free-electron laser was operated at a fundamental wavelength of 7.97 nm and radiation at the fifth harmonic originating from self-amplified stimulated emission at 1.59 nm with an average energy of 4 nJ per pulse was detected. We demonstrate the feasibility of resonant magnetic scattering at FEL sources by using a Co/Pd multilayer as prototype sample that was illuminated with 20-fs-long soft x-ray pulses tuned to the Co L{sub 3} absorption edge at 778.1 eV (1.59 nm)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Contrasting behavior of covalent and molecular carbon allotropes exposed to extreme ultraviolet and soft x-ray free-electron laser radiation

All carbon materials, e.g., amorphous carbon (a-C) coatings and C 60 fullerene thin films, play an important role in short-wavelength free-electron laser (FEL) research motivated by FEL optics development and prospective nanotechnology applications. We investigate responses of a-C and C 60 layers to the extreme ultraviolet (SPring-8 Compact SASE Source in Japan) and soft x-ray (free-electron laser in Hamburg) free-electron laser radiation by Raman spectroscopy, differential interference contrast, and atomic force microscopy. A remarkable difference in the behavior of covalent (a-C) and molecular ( C 60 ) carbonaceous solids is demonstrated under these irradiation conditions. Low thresholds for ablation of a fullerene crystal (estimated to be around 0.15 eV/atom for C 60 vs 0.9 eV/atom for a-C in terms of the absorbed dose) are caused by a low cohesive energy of fullerene crystals. An efficient mechanism of the removal of intact C 60 molecules from the irradiated crystal due to Coulomb repulsion of fullerene-cage cation radicals formed by the ionizing radiation is revealed by a detailed modeling.

36 MATERIALS SCIENCE↗

Three-Dimensional Wigner-Function Description of the Quantum Free-Electron Laser

A free-electron laser (FEL) operating in the quantum regime can provide a compact and monochromatic x-ray source. Here we present the complete quantum model for a FEL with a laser wiggler in three spatial dimensions, based on a discrete Wigner-function formalism taking into account the longitudinal momentum quantization. The model describes the complete spatial and temporal evolution of the electron and radiation beams, including diffraction, propagation, laser wiggler profile and emittance effects. The transverse motion is described in a suitable classical limit, since the typical beam emittance values are much larger than the Compton wavelength quantum limit. In this approximation we derive an equation for the Wigner function which reduces to the three-dimensional Vlasov equation in the complete classical limit. Preliminary numerical results are presented together with parameters for a possible experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent Electron Cooling

Cooling intense high-energy hadron beams poses a major challenge for modern accelerator physics. The synchrotron radiation emitted from such beams is feeble; even in the Large Hadron Collider (LHC) operating with 7 TeV protons, the longitudinal damping time is about 13 hours. None of the traditional cooling methods seem able to cool LHC-class protons beams. In this Letter, we present a novel method of coherent electron cooling based on a high-gain free-electron laser (FEL). This technique could be critical for reaching high luminosities in hadron and electron-hadron colliders.

43 PARTICLE ACCELERATORS↗

Time-Dependent, Three-Dimensional Simulation of Free-Electron-Laser Oscillators

We describe a procedure for the simulation of free-electron-laser (FEL) oscillators. The simulation uses a combination of the MEDUSA simulation code for the FEL interaction and the OPC code to model the resonator. The simulations are compared with recent observations of the oscillator at the Thomas Jefferson National Accelerator Facility and are in substantial agreement with the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suppression of Exponential Electronic Decay in a Charged Environment

Inner-shell ionization of atoms and molecules leads to the creation of highly excited ionic states that often decay by electron emission. The dynamics of the decay is usually assumed to be exponential and the process is characterized by a decay rate. Here we show that in a multiply ionized cluster created by interaction with a high-intensity free-electron laser (FEL) radiation, trapping of the emitted electron by the neighboring ions changes the character of the decay dynamics qualitatively to the extent that it can become oscillatory instead of exponential. Implications of the predicted effect on Coster-Kronig and interatomic Coulombic decay processes induced by FELs are investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generating Optical Orbital Angular Momentum in a High-Gain Free-Electron Laser at the First Harmonic

A scheme to generate intense coherent light that carries orbital angular momentum (OAM) at the fundamental wavelength of an x-ray free-electron laser (FEL) is described. The OAM light is emitted as the dominant mode of the system until saturation provided that the helical microbunching imposed on the electron beam is larger than the shot-noise bunching that leads to self-amplified emission. Operating at the fundamental, this scheme is more efficient than alternate schemes that rely on harmonic emission, and can be applied to x-ray FELs without using external optical mode conversion elements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗