Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FARADAY EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Effective Verdet Constant in a Terbium-Doped-Core Phosphate Fiber

The concept of an effective Verdet constant is proposed and experimentally validated. The effective Verdet constant of light propagation in a fiber includes contributions from the materials in both the core and the cladding. It is measured in a 25 wt.% terbium-doped-core phosphate fiber to be -6.2±0.4 rad/ (Tm) at 1053 nm, which is six times larger than silica fiber. The result agrees well with Faraday rotation theory in optical fiber.

Sun, L↗

Polarization analysis by off-axis digital holography with an improved optical system and an evaluation of its performance by simulation

An optical system of off-axis digital holography for imaging the Jones vector of an object wave is improved, and a Faraday rotator for the reference wave is also newly constructed. To evaluate the accuracy of the polarization analysis, quarter- and half-wave plates are used as the object, and the distribution of the polarization state of the transmitted light is analyzed for various orientations of the wave plates. The polarization analysis is also simulated, and the effect of a finite value of the extinction ratio and the modulation error for the reference wave is investigated numerically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a multi-kW, large-aperture gas-cooled Faraday rotator

We characterize a large-aperture gas-cooled Faraday rotator (FR) designed to mitigate stress-induced depolarization in high-energy, high-power laser systems. The rotator, based on ceramic TGG, was tested using a 150 mW probe beam at 1047 nm and a pump beam at 1070 nm. Compensating for the birefringence induced by the surrogate depolarization plate at 3.3 kW of effective pump power, the rotator reduces the spatially in-homogeneous depolarized light containing linear, circular, and elliptical polarization states to nearly linear with approximately 0.8% (or −21 dB) of residual depolarized energy. The FR demonstrated effective depolarization compensation across its 58×58 mm 2 aperture.

47 OTHER INSTRUMENTATION↗

Effects on the geomagnetic tail at 60 earth radii of the geomagnetic storm of April 9, 1971.

A geomagnetic storm beginning with an sc occurred on Apr. 9, 1971. During the storm the charged particle lunar environment experiment at the Apollo 14 site, the solar wind spectrometer experiment at the Apollo 12 site, and the Ames magnetometers on Explorer 35 took data in the magnetosheath, at the magnetopause, in the plasma sheet, and in the high-latitude geomagnetic tail. The MIT Faraday cup and Ames magnetometers on board Explorer 33 monitored the solar wind. The data show that the storm was caused by a corotating tangential discontinuity in the solar wind, the magnetopause position is strongly dependent on the attack angle of the solar wind, and the tail field strength was indirectly measured to increase from 10 to 14 gamma after the sc. During the main phase the field strength in the tail was observed to increase to between 28 and 34 gamma. This increase is consistent with a thermal and magnetic compression of the tail radius from about 26 to about 16 earth radii.

Burke, W. J.↗

Synergistic Enhancement of Electrocatalytic CO 2 Reduction with Gold Nanoparticles Embedded in Functional Graphene Nanoribbon Composite Electrodes

Regulating the complex environment accounting for the stability, selectivity, and activity of catalytic metal nanoparticle interfaces represents a challenge to heterogeneous catalyst design. Here in this paper, we demonstrate the intrinsic performance enhancement of a composite material composed of gold nanoparticles (AuNPs) embedded in a bottom-up synthesized graphene nanoribbon (GNR) matrix for the electrocatalytic reduction of CO 2 . Electrochemical studies reveal that the structural and electronic properties of the GNR composite matrix increase the AuNP electrochemically active surface area (ECSA), lower the requisite CO 2 reduction overpotential by hundreds of millivolts (catalytic onset > -0.2 V versus reversible hydrogen electrode (RHE)), increase the Faraday efficiency (>90%), markedly improve stability (catalytic performance sustained over >24 h), and increase the total catalytic output (>100-fold improvement over traditional amorphous carbon AuNP supports). The inherent structural and electronic tunability of bottom-up synthesized GNR-AuNP composites affords an unrivaled degree of control over the catalytic environment, providing a means for such profound effects as shifting the rate-determining step in the electrocatalytic reduction of CO 2 to CO, and thereby altering the electrocatalytic mechanism at the nanoparticle surface.

36 MATERIALS SCIENCE↗

Effect of low-frequency ambient magnetic fields on the control unit and RF head of a commercial SQUID magnetometer

The control unit and RF head of the SHE model 330XRFSQUID system are shown to be sensitive to ambient ac magnetic fields below 1 HZ, which cause the appearance of false signals corresponding to a magnetometer signal of 0.000001 phi(0) per gauss of field applied. The control unit shows a sensitivity that is linear with frequency, suggesting that the signal is generated by Faraday induction. In contrast, the RF head response is independent of frequency and shows a strong second-harmonic coversion. This response may be due to the magnetic field sensitivity of the ferrite core inductor in the tuned amplifier of the RF head. These signals induced by ambient fields are a potential source of error in Stanford's Relativity Gyroscope experiment, which uses SQUID's on board a rolling satellite as part of the gyroscope readout system. The extent of the magnetic field sensitivity in these components necessitates the use of additional magnetic shielding aboard the satellite.

Marcus, C. M.↗

ROSAT observations and correlated X-ray, radio, and optical features in cluster cooling flows

Images from the Rosat high resolution imager (HRI) of the central regions of cluster cooling flows are compared to optical continuum and radio continuum images. The radio sources associated with cooling flows show two distinct morphologies. In most sources, the jets appear to be inflating distinct lobes of radio plasma. These sources show strong Faraday rotation, radio pressures in agreement with the X-ray gas pressure, and a radio X-ray spatial anti-correlation. A few cooling sources are seen to have amorphous radio morphologies, Faraday depolarization, low radio pressure and a possible radio-X-ray spatial correlation. These properties suggest that the radio jets are disrupted and that the radio plasma is mixed with the thermal X-ray plasma. Blue continuum lobes are seen in several cooling flow central galaxies. These could be due to star formation induced by the hydrodynamical effects of the radio source or due to the scattered light from beamed emission from the active galactic nucleus.

Sarazin, C. L.↗

On the reversibility of the Meissner effect and the angular momentum puzzle

It is generally believed that the laws of thermodynamics govern superconductivity as an equilibrium state of matter, and hence that the normal-superconductor transition in a magnetic field is reversible under ideal conditions. Because eddy currents are generated during the transition as the magnetic flux changes, the transition has to proceed infinitely slowly to generate no entropy. Experiments showed that to a high degree of accuracy no entropy was generated in these transitions. However, in this paper we point out that for the length of times over which these experiments extended, a much higher degree of irreversibility due to decay of eddy currents should have been detected than was actually observed. We also point out that within the conventional theory of superconductivity no explanation exists for why no Joule heat is generated in the superconductor to normal transition when the supercurrent stops. In addition we point out that within the conventional theory of superconductivity no mechanism exists for the transfer of momentum between the supercurrent and the body as a whole, which is necessary to ensure that the transition in the presence of a magnetic field respects momentum conservation. We propose a solution to all these questions based on the alternative theory of hole superconductivity. The theory proposes that in the normal-superconductor transition there is a flow and backflow of charge in direction perpendicular to the phase boundary when the phase boundary moves. We show that this flow and backflow explains the absence of Joule heat generated by Faraday eddy currents, the absence of Joule heat generated in the process of the supercurrent stopping, and the reversible transfer of momentum between the supercurrent and the body, provided the current carriers in the normal state are holes. - Highlights: • The normal-superconductor phase transition is reversible. • Within the conventional theory, Foucault currents give rise to irreversibility. • To suppress Foucault currents, charge has to flow in direction perpendicular to the phase boundary. • The charge carriers have to be holes. • This solves also the angular momentum puzzle associated with the Meissner effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-dimensional expansion of finite-size barium photoplasma in an electrostatic field

Two-dimensional evolution of finite-size barium photoplasma, produced using multistep-resonant ionization is experimentally investigated in an externally applied electrostatic field. Several processes like bulk motion, ambipolar diffusion, Coulomb repulsion, Child-Langmuir flux, bounded diffusion, etc. that contribute to its expansion, have been identified. They are quantified with the help of signals recorded by Faraday cups, electrodes and plates and by two-dimensional particle-in-cell simulation. These processes are superimposed and their relative magnitudes decide the evolution of the photoions. When external field is dominant, a significant fraction of ions reach the cathode with negligible vertical spread and the plasma motion can be considered as one-dimensional. However, when plasma collective effects are dominant, then the different mechanisms become comparable and the photoplasma expands in two dimensions. The spread of photoions at different locations in parallel plate geometry is determined as a function of plasma density and compared with simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three dimensional potential and current distributions in a Hall generator with assumed velocity profiles

Three-dimensional potential and current distributions in a Faraday segmented MHD generator operating in the Hall mode are computed. Constant conductivity and a Hall parameter of 1.0 is assumed. The electric fields and currents are assumed to be coperiodic with the electrode structure. The flow is assumed to be fully developed and a family of power-law velocity profiles, ranging from parabolic to turbulent, is used to show the effect of the fullness of the velocity profile. Calculation of the square of the current density shows that nonequilibrium heating is not likely to occur along the boundaries. This seems to discount the idea that the generator insulating walls are regions of high conductivity and are therefore responsible for boundary-layer shorting, unless the shorting is a surface phenomenon on the insulating material.

Stankiewicz, N.↗

As a Matter of Force—Systematic Biases in Idealized Turbulence Simulations

Many astrophysical systems encompass very large dynamical ranges in space and time, which are not accessible by direct numerical simulations. Thus, idealized subvolumes are often used to study small-scale effects including the dynamics of turbulence. These turbulent boxes require an artificial driving in order to mimic energy injection from large-scale processes. In this paper, we show and quantify how the autocorrelation time of the driving and its normalization systematically change the properties of an isothermal compressible magnetohydrodynamic flow in the sub- and supersonic regime and affect astrophysical observations such as Faraday rotation. For example, we find that δ-in-time forcing with a constant energy injection leads to a steeper slope in kinetic energy spectrum and less-efficient small-scale dynamo action. In general, we show that shorter autocorrelation times require more power in the acceleration field, which results in more power in compressive modes that weaken the anticorrelation between density and magnetic field strength. Thus, derived observables, such as the line-of-sight (LOS) magnetic field from rotation measures, are systematically biased by the driving mechanism. Finally, we argue that δ-in-time forcing is unrealistic and numerically unresolved, and conclude that special care needs to be taken in interpreting observational results based on the use of idealized simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of ionospheric electron content from the Faraday rotation of geostationary satellite signals.

Observation that calculations of the integrated electron content up to the height of the satellite, using a wide range of model ionospheres (with a peak at 300 km) could be up to four times the value deduced from Faraday rotation measurements. However, using a fixed mean field height of 400 km, the observed Faraday rotation gives the electron content up to a height h sub F of 2000 km with an accuracy of plus or minus 3%. For observations at different magnetic and geographic latitudes, and geostationary satellites at different longitudes, the optimum value of h sub F varies by only plus or minus 200 km. Nighttime increases in the height of the ionosphere have little effect on h sub F, but increase the mean field height to about 470 km. Using a fixed value of 420 km, with h sub F = 2000 km, gives an accuracy of plus or minus 5% under most conditions.

Titheridge, J. E.↗

SU-C-201-03: Ionization Chamber Collection Efficiency in Pulsed Radiation Fields of High Pulse Dose

Purpose: To investigate the reduction of collection efficiency of ionization chambers (IC) by volume recombination and its correction in pulsed fields of very high pulse dose. Methods: Measurements of the collection efficiency of a plane-parallel advanced Markus IC (PTW 34045, 1mm electrode spacing, 300V nominal voltage) were obtained for collection voltages of 100V and 300V by irradiation with a pulsed electron beam (20MeV) of varied pulse dose up to approximately 600mGy (0.8nC liberated charge). A reference measurement was performed with a Faraday cup behind the chamber. It was calibrated for the liberated charge in the IC by a linear fit of IC measurement to reference measurement at low pulse doses. The results were compared to the commonly used two voltage approximation (TVA) and to established theories for volume recombination, with and without considering a fraction of free electrons. In addition, an equation system describing the charge transport and reactions in the chamber was solved numerically. Results: At 100V collection voltage and moderate pulse doses the established theories accurately predict the observed collection efficiency, but at extreme pulse doses a fraction of free electrons needs to be considered. At 300V the observed collection efficiency deviates distinctly from that predicted by any of the established theories, even at low pulse doses. However, the numeric solution of the equation system is able to reproduce the measured collection efficiency across the entire dose range of both voltages with a single set of parameters. Conclusion: At high electric fields (3000V/cm here) the existing theoretical descriptions of collection efficiency, including the TVA, are inadequate to predict pulse dose dependency. Even at low pulse doses they might underestimate collection efficiency. The presented, more accurate numeric solution, which considers additional effects like electric shielding by the charges, might provide a valuable tool for future investigations. This project was funded by the German ministry of research and education (BMBF) under grant number: 03Z1N511 and by the state of Saxony under grant number: B 209.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FRIB Lithium Stripper Thickness and Stability Measurements

This report documents the results of a number of tests of the prototype liquid lithium thin film stripper for FRIB, in which 1) the thickness of a flowing film of liquid lithium was measured in real time, 2) the thickness distribution of the film was measured in real time, and 3) the stability of the films was determined based on both digital video recordings and digital signal recordings of Faraday cup current. The high-pressure liquid lithium system, capable of driving liquid lithium at up to 13.9 MPa (2000 psia) through a nozzle opening as large as 1 mm (40 mil) in diameter, is described. As part of the work reported here, the system was modified to facilitate convenient and efficient testing of design variations in nozzle and deflector geometry so that their effect on film thickness and film stability improvement could be determined. A previously developed electron beam based thickness measuring system was recalibrated for this specific geometry and used to measure the film thickness under a number of different flow conditions and deflector designs. A thin film ~9 mm in width flowing at a velocity of ~60 m/s was formed under several flow conditions and with several deflector designs. A deflector design was found that practically eliminates the puddle issue. The film stability is judged to be excellent; based upon a ~25 minute stable flow run during which time only a single breakup of the film occurred. That breakup event, which lasted only about 0.6 second, was most likely caused by an Ar gas bubble that became trapped in the high-pressure lithium line, during lithium transfer operations. The trapped gas issue will not be a problem for the FRIB stripper system because a pumped, closed loop system will be used, eliminating the need for lithium transfer operations. Based on thickness distribution measurements from the electron beam system, the expected central thickness (at halfway between center spot and bottom spot) is 632 ± 35 μg/cm2 (± 5.5% for 1 mm spot diameter). This corresponds to a physical thickness of the flowing lithium film of 12.3 ± 0.7 μm.

36 MATERIALS SCIENCE↗

Anomalous spin splitting of electrons in type-II InSb quantum dots in InAs

Magnetooptical studies of heterostructures with type-II InSb quantum dots in the InAs matrix grown by molecular beam epitaxy are carried out. Unusual behavior of magnetophotoluminescence from quantum dots measured in the Faraday geometry in the samples with multiple planes of quantum dots is found. Specifically, the peak with {sigma}{sup -} polarization, which corresponds to transitions of electrons with s = +1/2, has a higher energy than the {sigma}{sup +} peak corresponding to s = -1/2, which contradicts the negative value of the electron g factor both in the InAs matrix and in the InSb quantum dot. The effect can be interpreted as the result of competition of two channels of radiative recombination, which differ by the initial states of electrons belonging either to the InSb quantum dots or to shallow-level donors in the InAs matrix.

36 MATERIALS SCIENCE↗

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)↗

Effect of solenoidal magnetic field on drifting laser plasma

An ion source for accelerators requires to provide a stable waveform with a certain pulse length appropriate to the application. The pulse length of laser ion source is easy to control because it is expected to be proportional to plasma drifting distance. However, current density decay is proportional to the cube of the drifting distance, so large current loss will occur under unconfined drift. We investigated the stability and current decay of a Nd:YAG laser generated copper plasma confined by a solenoidal field using a Faraday cup to measure the current waveform. It was found that the plasma was unstable at certain magnetic field strengths, so a baffle was introduced to limit the plasma diameter at injection and improve the stability. Magnetic field, solenoid length, and plasma diameter were varied in order to find the conditions that minimize current decay and maximize stability.

43 PARTICLE ACCELERATORS↗