Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Airside HVAC BESTEST: HVAC Air-Distribution System Model Test Cases for ASHRAE Standard 140

This paper summarizes recent work to develop new airside HVAC equipment model analytical verification test cases for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. The analytical verification test method allows comparison of simulation results from a wide variety of building energy simulation programs with quasi-analytical solutions, further described below. Standard 140 is widely cited for evaluating software for use with performance-path energy efficiency analysis, in conjunction with well-known energy-efficiency standards including ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. Airside HVAC Equipment is a common area of modelling not previously explicitly tested by Standard 140. Integration of the completed test suite into Standard 140 is in progress.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Single Thread to Fortran Coarray Transition Process for the Control Algorithm in the Space Radiation Code HZETRN

Exa-scale computing is the direction by industry and government are going to generate solutions to problems they deem necessary. Computing hardware is being developed to achieve the transition from Peta-scale to Exa-scale with more CPUs (Central Processing Units) that have more cores per CPU and more accelerators (GPGPUs (General Purpose Graphics Processing Units) and MICs (Many Integrated Cores)) per node. To fully utilize the hardware available now and in the future, algorithms must become multi-threaded. There are a few methods to generate multi-threaded software such as MPI (Message Passing Interface) and OpenMP (Multi-Processing) / OpenACC (ACCelerator). This paper concentrates on using Coarray Fortran to convert the Fortran 95 based HZETRN (High Z and Energy TRaNsport) code's control algorithm from a single threaded code to a multithreaded code. The resultant Coarray code was 32.5 times faster (with a theoretical speed-up of 74.5 times) than the single threaded version on the hardware tested, as reliable as the Fortran 95 version, and, as it uses native Fortran, was as maintainable as the Fortran 95 version. The Coarray code can be maintained by the same project engineers and scientists who created the original single threaded code. This transition process can be utilized on a C language based code with a compiler that has the UPC (Universal Parallel C) extensions to C.

Singleterry, Robert C., Jr.↗

Alabama Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Alabama homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Alabama homeowners will save $\$$2,117 over 30 years under the 2009 IECC, with savings still higher at $\$$6,182 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for both the 2009 and 2012 IECC. Average annual energy savings are $\$$168 for the 2009 IECC and $462 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Kansas Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Kansas homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Kansas homeowners will save $\$$2,556 over 30 years under the 2009 IECC, with savings still higher at $\$$8,828 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$155 for the 2009 IECC and $\$$543 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Louisiana Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Louisiana homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Louisiana homeowners will save $\$$1,663 over 30 years under the 2009 IECC, with savings still higher at $\$$4,107 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for both the 2009 and 2012 IECC. Average annual energy savings are $\$$149 for the 2009 IECC and $\$$358 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mississippi Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Mississippi homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Mississippi homeowners will save $\$$2,022 over 30 years under the 2009 IECC, with savings still higher at $\$$5,400 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for both the 2009 and 2012 IECC. Average annual energy savings are $\$$164 for the 2009 IECC and $\$$422 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Missouri Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Missouri homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Missouri homeowners will save $\$$2,229 over 30 years under the 2009 IECC, with savings still higher at $\$$7,826 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$143 for the 2009 IECC and $\$$507 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tennessee Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Tennessee homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Tennessee homeowners will save $\$$1,809 over 30 years under the 2009 IECC, with savings still higher at $\$$6,102 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$123 for the 2009 IECC and $\$$415 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building America Best Practices Series: Volume 7.1 - High-Performance Home Technologies: Guide to Determining Climate Regions by County

This report for DOE's Building America program helps builders identify which Building America climate region they are building in. The guide includes maps comparing the Building America regions with climate designations used in the International Energy Conservation Code for Residential Buildings and lists all U.S. counties by climate zone. A very brief history of the development of the Building America climate map and descriptions of each climate zone are provided. This report is available on the Building America website www.buildingamerica.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Air- and Water-Resistive Barriers -– Technology Verification

Infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning (HVAC) loads in commercial buildings. Air leakage is responsible for about 6% of the total energy used by the commercial building sector. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. These include the 3M 3015 primer-less self-adhered membrane, 3M 3015VP vapor permeable primer-less self-adhered membrane, and 3M 2085VP vapor permeable fluid-applied air barrier membrane. ORNL verified the performance of the 3M 3015, 3015VP and 2085VP air- and water- resistive barriers by conducting two field studies. The first one involved side-by-side evaluations in eight unoccupied test facilities in Cottage Grove, MN, that included the 3M membranes and commonly used air barrier materials such as a self-adhered membrane with primer and a mechanically-fastened membrane with taped joints. The facilities were monitored for 24 months and the collected data were used to calibrate simulation models that in turn were employed to calculate energy consumption and savings because of improvements in airtightness. After two years, results indicate that the test facilities with the new 3M technologies had leakage rates that were slightly lower than the buildings with traditional air barrier materials. The calibrated model for the test facility with the 3M 3015 membrane was used to calculate energy savings due to improved airtightness when compared to a building without an air barrier. Findings suggest that a building in Minneapolis, MN, or Fairbanks, AK, that has a properly installed air barrier system can have annual HVAC electricity use that is about 36% lower than if the building did not have an air barrier. Similarly, decreases in natural gas use can be about 25%. The second field evaluation involved the LifeSource building in Minneapolis, MN, and the Sierra Trading Post building in Woodbury, MN. Both of these were recently completed and use the 3M 3015 and 3015VP membranes as their air- and water- resistive barriers, respectively. Blower door test results show that LifeSource has an average air leakage rate of 0.06 cfm/ft 2 at 75 Pa, or 85% lower than the 0.4 cfm/ft 2 at 75 Pa specified in the 2015 International Energy Conservation Code (IECC). The leakage rate in the Sierra building is 0.15 cfm/ft 2 at 75 Pa or 63% than the IECC value. According to simulation results, LifeSource lowered its annual heating and cooling cost by about $\$$4600 or 10% when compared to a similar building that lacked an air barrier system. In the case of the Sierra building, savings were $5,900 or 41%. These field evaluations serve as examples of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrate the energy and financial savings that building envelopes with low air leakage rates could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

West Virginia Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for West Virginia homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, West Virginia homeowners will save $\$$1,996 over 30 years under the 2009 IECC, with savings still higher at $\$$7,301 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$135 for the 2009 IECC and $\$$480 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Arkansas Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Arkansas homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Arkansas homeowners will save $\$$1,948 over 30 years under the 2009 IECC, with savings still higher at $\$$6,679 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for the 2009 and 1 year for the 2012 IECC. Average annual energy savings are $\$$147 for the 2009 IECC and $\$466 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Arizona Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Arizona homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost-effective over a 30-year life cycle. On average, Arizona homeowners will save $\$$3,245 over 30 years under the 2009 IECC, with savings still higher at $\$$6,550 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2009 and 2 years with the 2012 IECC. Average annual energy savings are $\$$231 for the 2009 IECC and $486 for the 2012 IECC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the Need for a Unified and Collaboratively Developed Residential Building Simulation Platform: Preprint

Residential building energy simulations are becoming ever more pervasive; they form the basis of energy efficient building design, zero energy goals, codes and standards, home certification and ratings industries, utility programs, regional/state planning, and technology assessments. And yet the residential building simulation community is highly fragmented with a patchwork of simulation engines with varying models, inputs, assumptions, and results. This inconsistency degrades confidence in these tools, increases industry-wide development and maintenance costs, and slows the availability of new efficiency technology models. The need for collaboration on an impartial, transparent, and capable residential building simulation platform has never been greater. But to develop and maintain a state-of-the-art simulation platform requires a dedicated and sustained investment. By leveraging existing resources and expertise from multiple entities/regions, a unified and collaboratively developed simulation platform can provide increased levels of energy efficiency at an accelerated pace. This paper presents the advantages and disadvantages of a unified residential building simulation platform in relationship to four real-world examples (RESNET HERS ratings, utility programs, California's Title 24, and DOE). The paper covers recent developments and improved capabilities that may move us closer to an ideal simulation platform and what challenges remain. The hope is to spur a frank and honest dialogue about how to work together towards the vision of achieving deeper and more reliable energy savings in the residential buildings industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the Need for a Unified and Collaboratively Developed Residential Building Simulation Platform

Residential building energy simulations are becoming ever more pervasive; they form the basis of energy efficient building design, zero energy goals, codes and standards, home certification and ratings industries, utility programs, regional/state planning, and technology assessments. And yet the residential building simulation community is highly fragmented with a patchwork of simulation engines with varying models, inputs, assumptions, and results. This inconsistency degrades confidence in these tools, increases industry-wide development and maintenance costs, and slows the availability of new efficiency technology models. The need for collaboration on an impartial, transparent, and capable residential building simulation platform has never been greater. But to develop and maintain a state-of-the-art simulation platform requires a dedicated and sustained investment. By leveraging existing resources and expertise from multiple entities/regions, a unified and collaboratively developed simulation platform can provide increased levels of energy efficiency at an accelerated pace. This paper presents the advantages and disadvantages of a unified residential building simulation platform in relationship to four real-world examples (RESNET HERS ratings, utility programs, California's Title 24, and DOE). The paper covers recent developments and improved capabilities that may move us closer to an ideal simulation platform and what challenges remain. The hope is to spur a frank and honest dialogue about how to work together towards the vision of achieving deeper and more reliable energy savings in the residential buildings industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Storage in Local Zoning Ordinances

Increasing policy support and declining prices for battery energy storage systems (BESS) are driving rapid growth in the installation of these systems in the United States and around the world. Because a BESS is modular in nature and has limited infrastructure requirements, it can be built in close proximity to existing uses, which creates the potential for conflict. As the use of BESS grows, local planning and zoning staff are increasingly being asked to determine where the systems can be built and how their impacts on surrounding uses can be mitigated. While a large-scale BESS offers significant electric grid and societal benefits, it can also pose safety, visual, auditory, and environmental impacts on the community in which it is located. While these are material impacts, current safety codes for energy storage systems and land use frameworks provide planners with the necessary tools and processes to mitigate those impacts and ensure that their communities safely receive the benefits of energy storage systems. This report provides an overview of BESS from a land use perspective and describes their implications for zoning and project permitting. It concludes with an analysis of current energy storage zoning standards adopted by local jurisdictions in the U.S. Its intent is to objectively inform land use decisions for energy storage projects by equipping planning officials with relevant information about these technologies and knowledge of what questions to ask during review processes, so that energy storage projects can move forward in ways that will benefit electric systems while not unduly affecting host communities.

25 ENERGY STORAGE↗