Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electricity Network Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Evaluating Energy Efficiency Opportunities from Connected and Automated Vehicle Deployments Coupled with Shared Mobility in California

Connected and Automated Vehicles (CAVs) can be considered to be a disruptive transportation technology, with the potential to significantly improve overall transportation system efficiency; however, CAVs may increase induce vehicle miles traveled (VMT) and bring on greater energy consumption. Further, shared mobility is another disruptive transportation event that is reshaping our travel patterns. The primary goal of this project was to extensively collect data from vehicles and associated infrastructure equipped with CAV technologies from both real-world experiments and simulation studies mainly deployed in California, and develop a comprehensive framework for evaluating energy efficiency opportunities from large-scale (e.g., statewide) introduction of CAVs and a wide deployment of shared mobility systems in a variety of scenarios. To quantify the combined impact of CAV and shared mobility on travel behavior, traffic performance, and energy efficiency, a unique mesoscopic simulation-based model was developed for mobility and energy efficiency evaluation considering these disruptive transportation technologies. As a complement to existing studies on nationwide evaluation of CAVs’ energy impacts, this project was focused on data collection efforts and CAV applications under congested traffic environments that are frequently experienced on a massive scale across the major metropolitan areas in California. Extensive real-world data collection supplemented with simulation studies were conducted to cover a variety of CAV and shared mobility scenarios, particularly on scenarios less-explored in the existing research. Another key component of this project was to consider the interaction between different CAV technologies and shared mobility models, and the compound effect on energy efficiency. A comprehensive modeling suite was developed to quantify the impact of new mobility technologies on travel behavior and traffic performance. The developed modeling framework includes an energy intensity module, mode choice module and activity generation module that are integrated into an agent-based BEAM simulation platform to perform impact analysis based on a variety of scenarios. In addition, the RouteE model has been upgraded to incorporate the impact of CAVs on traffic flow, VMT and energy intensity, using micro-simulation data collected from both freeways and urban arterials. A novel fundamental influencing factor (FIF) mode choice model was developed to link CAV and shared mobility components with travel behaviors, and adapted into the BEAM-centered model framework. A statewide energy inventory was constructed under various CAV technology deployment scenarios by incorporating datasets and models for predicting vehicle market share and vehicle usage, which are tightly associated with the penetration of shared mobility systems. Based applying this modeling suite to a calibrated network in Riverside California, it was found that cooperative automated driving in general will improve mobility, but automated vehicles, even when deployed in a shared autonomous fleet, will likely bring an increase of VMT (up to 36%) due to mode shifts and deadheading. Ride-hailing vehicles typically have better energy efficiency and a higher share of electric vehicles, which helps offset the negative impact from VMT increases when estimating the system-level energy consumption. In general, simulation results show a 6% increase in energy consumption for the scenarios with an increasing shift to ride-hailing modes. The statewide analysis based on the National Household Travel Survey (NHTS) sample data is consistent with the findings from the Riverside network and validate the developed clustering-prediction modeling methodology. The outcomes from this project will help close the knowledge gap on recognizing the potential performance and energy impacts of a broad deployment of CAV and shared mobility technologies across a wide range of roadway infrastructure with varying levels of congestion. Results from this project: 1) will support policymakers in steering CAV development and deployment towards an energy favorable direction; 2) reduce uncertainties in estimating energy saving opportunities from new mobility technologies and services; 3) increase the confidence of CAV technology investors both on the infrastructure side (i.e., transportation agencies) and on the vehicle side (i.e., OEMs); and 4) expedite the deployment of energy-efficient CAV and shared mobility applications.

33 ADVANCED PROPULSION SYSTEMS↗

Synchronization of Lienard-Type Oscillators in Uniform Electrical Networks

This paper presents a condition for global asymptotic synchronization of Lienard-type nonlinear oscillators in uniform LTI electrical networks with series R-L circuits modeling interconnections. By uniform electrical networks, we mean that the per-unit-length impedances are identical for the interconnecting lines. We derive conditions for global asymptotic synchronization for a particular feedback architecture where the derivative of the oscillator output current supplements the innate current feedback induced by simply interconnecting the oscillator to the network. Our proof leverages a coordinate transformation to a set of differential coordinates that emphasizes signal differences and the particular form of feedback permits the formulation of a quadratic Lyapunov function for this class of networks. This approach is particularly interesting since synchronization conditions are difficult to obtain by means of quadratic Lyapunov functions when only current feedback is used and for networks composed of series R-L circuits. Our synchronization condition depends on the algebraic connectivity of the underlying network, and reiterates the conventional wisdom from Lyapunov- and passivity-based arguments that strong coupling is required to ensure synchronization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A LIS Validation Study at the KSC-ER using LDAR and Field Mill Data

The chance of having the TRMM satellite pass over east central Florida when there is lightning over the NASA Kennedy Space Center (KSC) and USAF Eastern Range (ER) is small; however, such a condition did occur on September 21, 1998 (Day 264). Starting at about 20:40 GMT, the Lightning Imaging Sensor (LIS) reported 5 flashes during a 90 second interval that the KSC-ER was within the sensor field of view. Ground-based instrumentation, the Lightning Detection and Ranging (LDAR) system and a network of electric field mills (FM), detected 6 flashes in the same interval. In this paper, we will compare the times and locations of the optical pulses that were detected by LIS with the times and locations of RF sources (LDAR) and the charges that were deposited by the flash (FM network). We will show that LIS responded to all flashes that the LDAR and FM network detected; however, two discharges that were separated by less than 1 second in time and by about 10 km in space were grouped as one flash by the LIS data processing algorithm. In spite of the fact that all flashes occurred near the edge of the LIS field of view, the locations of the LIS events were consistent with both the LDAR and FM locations (the latter are usually within 1-2 kilometers of each other and often are co-located). Two of the 5 flashes reported by LIS were shifted north by about 8 km from the corresponding LDAR and FM locations. The LIS flash times tended to be after the first LDAR pulse was detected and before the last, and the integrated light signal (per LIS event) was surprisingly constant over the 5 flashes that were detected by LIS. In the future, we plan to study more correlated events and will try to determine whether and how the LIS light signal is related to the charge transfer in the flash and/or the number and spatial extent of RF sources.

Koshak, William J.↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Results of the Impact of an Ion Thruster Plasma on Microwave Propagation

Electric thrusters are being considered for a variety of space missions because of the significant propellant savings that result from the use of high performance, electric propulsion technologies. Propellant mass savings reduces spacecraft launch requirements and increases mission lifetime and payload. The impact of electric thruster plasma plumes on microwave signal propagation however is an important spacecraft integration concern. Arcjets were the first electric thrusters to be considered for operational missions. Ling, et al. studied the effect of arcjet plumes on propagation. Arcjets produce a lightly ionized plume and Ling's analysis predicted that the plume would have a negligible effect on communication. Plumes from the higher performance ion thrusters being developed exhibit higher ionization levels, plasma temperatures and particle velocities than arcjets. Therefore, there was a need to assess the impact due to these plumes. To address this need, the authors designed and performed a series of experiments to examine propagation effects of plumes. The challenge with these experiments was that they had to be performed in the operational environment of the thruster. Therefore, the experiments were conducted inside a metal chamber which could be depressurized to simulate a near vacuum condition of space. The metal chamber presents a potential large source of error to the propagation measurements due to the corruption of the desired data by multiple wall reflections within the chamber. This chamber effect was minimized by employing a pulsed-continuous wave transmitter and receiver system. This system based on an HP8510 Network Analyzer, uses external hardware time gating to eliminate the clutter of the spurious reflections. Additionally, high gain antennas were used in the measurements to ensure that minimal amounts of energy were transmitted/received in undesirable directions. The measurements took place in Vacuum Facility 5 of the Electric Propulsion Laboratory at the NASA Glenn Research Center. This facility utilizes a cylindrical, stainless steel, vacuum chamber, which is 18.3 m long and 4.6 m in diameter. For the tests being described here a 30 cm diameter, xenon ion thruster was used. The thruster provided between 500 W and 2.3 kW of operating power. The thruster was mounted on a stand along the axis of the chamber near one of its ends and could be moved axially.

Zaman, Afroz J.↗

Optimal Synthesis of a Pulverized Coal Power Plant with Carbon Capture

Coal constitutes an important source of fuel for the production of power in the United States. For instance, in January 2009, pulverized coal (PC) power plants alone contributed to over 45 percent of the Nation's total electric power production. However, PC power plants also contribute to increased emissions of greenhouse gases principally carbon-dioxide (CO2). Recently, various carbon capture strategies have been under active investigation so as to make these plants compete with the more environmental friendly renewable energy sources. One such technology that has received considerable success is the capture of CO2 by an amine-based solvent extraction process. However, an aqueous absorption/stripping technology when used in a PC power plant can reduce the net power output of the plant by as much as 20-40%. The energy penalty comes from heating up the solvent in the regenerator, balancing the enthalpy of reaction, and water stripping. This energy penalty poses considerable limitations on commercial viability of the solvent extraction process and, as a result, various energy-saving modifications have been proposed in the literature ranging from the use of hybrid solvents to novel stripper configurations. In this paper, we show that the energy penalty can be further reduced by heat integration of various PC plant components with the carbon capture system. In addition to the release of greenhouse gases to the environment, PC plants also consume a large amount of freshwater. It is estimated that subcritical and supercritical PC plants have water losses of 714 gal/MWh and 639 gal/MWh, respectively. Water loss is based on an overall balance of the plant source and exit streams. This includes coal moisture, air humidity, process makeup, cooling tower makeup (equivalent to evaporation plus blowdown), process losses (including losses through reactions, solids entrainment, and process makeup/blowdown) and flue gas losses. The primary source of water used in PC power plants is the closed-loop steam-based (Rankine) power cycles. These plants need to condense large quantities of low-pressure steam back to water so that it can be reused to produce high pressure steam. However, this requires the removal of large quantities of heat from the low pressure steam in the condensation process. This is usually done by transferring the heat to cooling water, which in turn transfers this heat to the environment by evaporation to the atmosphere. Also, the inclusion of a carbon capture process can increase the raw water usage by as much as 95 percent. In this work, we use heat exchanger network synthesis followed by an optimization approach to process synthesis for developing strategies for reducing water use in a supercritical PC power plant with a carbon capture and compression system. Uncertainties associated with dry bulb temperature, relative humidity, and demand will also be considered in this analysis.

01 COAL, LIGNITE, AND PEAT↗

Experimental Results of the Impact of an Ion Thruster Plasma on Microwave Propagation

Electric thrusters are being considered for a variety of space missions because of the significant propellant savings that result from the use of high performance, electric propulsion technologies, Propellant mass savings reduces spacecraft launch requirements and increases mission lifetime and payload. The impact of electric thruster plasma plumes on microwave signal propagation however is an important spacecraft integration concern. Arcjets were the first electric thrusters to be considered for operational missions. Ling, et al., studied the effect of arcjet plumes on propagation. Arcjets produce a lightly ionized plume and Ling's analysis predicted that the plume would have a negligible effect on communication. Plumes from the higher performance ion thrusters being developed exhibit higher ionization levels, plasma temperatures and particle velo@ities than arcjets. Therefore, there was a need to assess the impact due to these plumes. To address this need, the authors designed and performed a series of experiments to examine propagation effects of plumes. The challenge with these experiments was that they had to be performed in the operational environment of the thruster. Therefore, the experiments were conducted inside a metal chamber which could be depressurized to simulate a near vacuum condition of space. The metal chamber presents a potential large source of error to the propagation measurements due to the corruption of the desired data by multiple wall reflections within the chamber. This chamber effect was minimized by employing a pulsed-continuous wave transmitter and receiver system. This system, based on an HP8510 Network Analyzer, uses external hardware time gating to eliminate the clutter of the spurious reflections. Additionally, high gain antennas were used in the measurements to ensure that minimal amounts of energy ",ere transmitted/received in undesirable directions. The measurements took place in Vacuum Facility 5 of the Electric Propulsion Laboratory at the NASA Glenn Research Center. This facility utilizes a cylindrical, stainless steel, vacuum chamber, which is 18.3 m long and 4.6 m in diameter. For the tests being described here a 30 cm diameter, xenon ion thruster was used. The thruster provided between 500 W and 2.3 kW of operating power. The thruster was mounted on a stand along the axis of the chamber near one of its ends.

Zaman, Afroz J.↗

The effect of molecular mobility on electronic transport in carbon nanotube-polymer composites and networks

A multiscale modeling approach to the prediction of electrical conductivity in carbon nanotube (CNT)–polymer composite materials is developed, which takes into account thermally activated molecular mobility of the matrix and the CNTs. On molecular level, a tight-binding density functional theory and non-equilibrium Green's function method are used to calculate the static electron transmission function in the contact between two metallic carbon nanotubes that corresponds to electron transport at 0 K. For higher temperatures, the statistical distribution of effective contact resistances is considered that originates from thermal fluctuations of intermolecular distances caused by molecular mobility of carbon nanotube and the polymer matrix. Based on this distribution and using effective medium theory, the temperature dependence of macroscopic electrical resistivity for CNT-polymer composites and CNT mats is calculated. The predicted data indicate that the electrical conductivity of the CNT-polymer composites increases linearly with temperature above 50 K, which is in a quantitative agreement with the experiments. Our model predicts a slight nonlinearity in temperature dependence of electric conductivity at low temperatures for percolated composites with small CNT loading. The model also explains the effect of glass transition and other molecular relaxation processes in the polymer matrix on the composite electrical conductivity. The developed multiscale approach integrates the atomistic charge transport mechanisms in percolated CNT-polymer composites with the macroscopic response and thus enables direct comparison of the prediction with the measurements of macroscopic material properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Engineering Bioelectronic Signal Transduction Using the Bacterial Type III Secretion Apparatus

Engineering efficient methods for living systems to transfer electrical energy to non-living systems, at relevant size scales, continues to challenge our knowledge of materials and biology. Our goal was to enable signal transduction between cells and inorganic materials, using controlled electron transport as the energy transfer mechanism. We envision using the cell as a living battery, providing a set of environmental signals to trigger synthetic biological networks that divert intracellular electron transport pathways to inorganic extracellular structures. Conversely, changing electron influxes could guide cellular responses. It is challenging, however, to precisely engineer nanostructured materials to achieve controllable catalytic or electronic properties and connect them with biological energy sources. Our approach to this problem is to engineer protein scaffolds, taking advantage of the native recognition, selectivity and self-assembly properties of these nano-scale building blocks as well as their native intracellular localization patterns. We are using a type III secretion system (T3SS) needle protein from Salmonella enterica, PrgI, as a template for metal nanowire synthesis for biosensing and bioenergy applications. We demonstrate that purified PrgI monomers spontaneously self assemble into long filaments, and that high-affinity peptide tags specific for attachment to functionalized particles can be integrated into the N-terminal region of PrgI. The resulting filaments selectively bind to gold, whether the filaments are assembled in vitro, sheared from cells, or remain attached to live S. enterica cell membranes. Chemical reduction of the gold modified PrgI variants results in structures that are several microns in length and which incorporate a contiguous gold surface.

59 BASIC BIOLOGICAL SCIENCES↗

Are coupled renewable-battery power plants more valuable than independently sited installations?

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$$10/MWh across ISOs on average. The highest boost occurs in California ($\$$15/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$$12.5/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$$12.5/MWh coupling penalty is reduced to $\$$1.6/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$$2–$\$$13/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

NASA Tech Briefs, April 2013

Topics covered include: Fully Integrated, Miniature, High-Frequency Flow Probe Utilizing MEMS Leadless SOI Technology; Nanoscale Surface Plasmonics Sensor With Nanofluidic Control; Advanced Dispersed Fringe Sensing Algorithm for Coarse Phasing Segmented Mirror Telescopes; Neural Network Back-Propagation Algorithm for Sensing Hypergols; Bulk Moisture and Salinity Sensor; Change-Based Satellite Monitoring Using Broad Coverage and Targetable Sensing; Circularly Polarized Microwave Antenna Element with Very Low Off-Axis Cross-Polarization; Ultra-Low Heat-Leak, High-Temperature Superconducting Current Leads for Space Applications; Flash Cracking Reactor for Waste Plastic Processing; An Automated Safe-to-Mate (ASTM) Tester; Wireless Chalcogenide Nanoionic-Based Radio-Frequency Switch; Compute Element and Interface Box for the Hazard Detection System; DOT Transmit Module; Composite Aerogel Multifoil Protective Shielding; Li-Ion Electrolytes with Improved Safety and Tolerance to High-Voltage Systems; Polymer-Reinforced, Non-Brittle, Lightweight Cryogenic Insulation; Controlled, Site-Specific Functionalization of Carbon Nanotubes with Diazonium Salts; Regenerable Sorbent for CO2 Removal; Sprayable Aerogel Bead Compositions With High Shear Flow Resistance and High Thermal Insulation Value; Lexan Linear Shaped Charge Holder with Magnets and Backing Plate; Robotic Ankle for Omnidirectional Rock Anchors; Wind, Wave, and Tidal Energy Without Power Conditioning; An Active Heater Control Concept to Meet IXO Type Mirror Module Thermal-Structural Distortion Requirement; Waterless Clothes-Cleaning Machine; Integrated Electrical Wire Insulation Repair System; LVGEMS Time-of-Flight Mass Spectrometry on Satellites; Surface Inspection Tool for Optical Detection of Surface Defects; Per-Pixel, Dual-Counter Scheme for Optical Communications; Certification-Based Process Analysis; Surface Navigation Using Optimized Waypoints and Particle Swarm Optimization; Smart-Divert Powered Descent Guidance to Avoid the Backshell Landing Dispersion Ellipse; Estimating Foreign-Object-Debris Density from Photogrammetry Data; Adaptive Sampling of Spatiotemporal Phenomena with Optimization Criteria; Building a 2.5D Digital Elevation Model From 2D Imagery; Eyes on the Earth 3D; Target Trailing With Safe Navigation for Maritime Autonomous Surface Vehicles; Adams-Based Rover Terramechanics and Mobility Simulator - ARTEMIS; ISTP CDF Skeleton Editor; Uplink Summary Generator (ULSGEN) Version 1.0; Robotics On-Board Trainer (ROBoT); Software Engineering Tools for Scientific Models; Automatic Data Filter Customization Using a Genetic Algorithm; Tracker Toolkit; Towards Efficient Scientific Data Management Using Cloud Storage; On a Formal Tool for Reasoning About Flight Software Cost Analysis; A Nanostructured Composites Thermal Switch Controls Internal and External Short Circuit in Lithium Ion Batteries; Spacecraft Crew Cabin Condensation Control; and Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex.

Source record↗

Risk-informed Hierarchical Control of Behind-the-Meter DERs with AMI Data Integration (Final Technical Report)

This project addresses several key barriers to implement the next generation demand response applications and provides a clear understanding of implementing hierarchical and standalone control using AMI data. Through this program, Eaton has developed and tested a meter-as-a-controller prototype with the help of other partners--- National Renewable Energy Laboratory (NREL), Electric Power Research Institute (EPRI), Pecan St Inc. (PSI), and Delaware Electric Cooperative (DEC). The controller can utilize residential controllable loads such as heating, ventilation, and air conditioner (HVAC), electric water heater and distributed energy resources like solar PV and battery energy storage systems for off-setting the demand that is required from the grid, thus providing reliable grid-services for demand reduction or peak shaving. The controller is also capable of coordinating the resources of the premises for better management and energy efficiency while meeting the comfort bound of the premises owner as quality-of-service. The development has been demonstrated in a three virtual-home setup at system performance lab of NREL with real appliances (HVAC, electric water heater, solar PV, and battery). The technology has also been proved through laboratory and field demonstration with successful interconnectivity (e.g., end-to-end communication and data exchange) between the residential appliances and utility through the RF network at Delaware Electric Co-op (DEC) in Delaware.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Size and shape of grain boundary network components and their atomic structures in polycrystalline nanoscale materials

Microstructure in polycrystalline materials is composed of grain boundary plane, triple junction line, and vertex point. They are the integral parts of the grain boundary network structure and the foundation for the structure-property relations. In polycrystalline, especially nanocrystalline, materials, it becomes increasingly difficult to probe the atomistic structure of the microstructure components directly in experiment due to the size limitation. Here, we present a numerical approach using pair correlation function from atomistic simulation to obtain the detailed information for atomic order and disorder in the grain boundary network in nanocrystalline materials. We show that the atomic structures in the different microstructural components are related closely to their geometric size and shape, leading to unique signatures for atomic structure in microstructural characterization at nanoscales. The dependence varies systematically with the characteristic dimension of the microstructural component: liquid-like disorder is found in vertex points, but a certain order persists in triple junctions and grain boundaries along the extended dimensions of these microstructure components.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Biomethanation to Upgrade Biogas to Pipeline Grade Methane

NREL is working closely with DOE, Electrochaea GmbH, and Southern California Gas Company (SoCalGas) to reduce costs of a biomethanation process capable of megawatt-scale deployment that upgrades organic biogas waste streams to produce pipeline quality renewable natural gas (RNG). Biomethanation is a two-step process using a single-celled methanogenic archaea that converts low-carbon low-cost hydrogen (H2) and waste carbon dioxide (CO2) to produce renewable methane (CH4). The process upgrades the biogenic CO2 - while allowing the CH4 to pass through - from biogas sources like dairies, wastewater treatment plants, and landfills. The CH4 produced is a drop-in direct replacement fuel and producers can participate in the growing number of carbon markets; like California's Low Carbon Fuel Standard and the Federal Renewable Fuel Standard. NREL and Argonne National Laboratory have completed a life cycle analysis using the GREET model to show that the biomethanation process produces RNG that is carbon negative even when H2 production via low-temperature water electrolysis is driven by the existing carbon intensity of California's electricity grid. And of course, even further carbon negative (-233 kg CO2e/kWh) when the electricity is produced from low-carbon sources like wind and solar. Leveraging lessons learned from operating SoCalGas' 700L 18-bar bioreactor system, NREL is designing and building a flexible RD&D platform that will enable field trials at biogas and other CO2 sources. A custom 16' long trailer will house a 20L 18-bar bioreactor, 3 - 25 kW proton exchange membrane electrolyzer, and dosing, thermal, and controls systems to support operations with only power, biogas, and water feedstocks required by the field locations. The end-of-project goal is to demonstrate pipeline quality RNG production (> 95% CH4, < 4% H2, <1% CO2, < 0.2% O2 and < 4 parts per million H2 sulfide) using real biogas feedstocks - thereby recycling both greenhouse gases for injection into the natural gas network or to be used onsite.

biogas upgrading↗

Optimal Gas-Electric Energy System Decarbonization Planning

As energy utilities implement climate change mitigation policies, system planners require strategies for achieving affordable emissions reductions. Coordinated planning of electric power and natural gas systems will allow synergistic investments to address cross-sector operational constraints, competing uses for net-zero emissions fuels, and shifts in energy demands across energy carriers. In this study, we develop a novel optimization program that finds the cost-minimizing mix of infrastructure expansion or reduction across gas and electric systems to satisfy sector-specific emissions constraints. Alongside energy supply resources, our framework allows for central-planning of end-use equipment stocks to allow switching between gas and electric appliances upon failure or premature replacement. The proposed model is used to simulate case study scenarios for a benchmark 24-pipe gas network coupled to a 24-node power system test network. We find that electrification of greater than 80% of core gas demands is a component of the least-cost solution for modeled energy systems. Despite this substitution, the gas system is maintained to service difficult-to-electrify customers and to deliver net-zero emissions gas to electricity generators in times of peak electricity demand. Restricting electrification of gas appliances increases reliance on power- to-gas technologies and increases annual costs by 15% in 2040. Neglecting constraints on pipeline blending of hydrogen can produce a misleading result that relies on hydrogen blend fractions of greater than 50%. In all cases, we find the average costs of delivered gas increase nearly 5-fold across the decarbonization transition, highlighting the importance of future work investigating cost-allocation strategies for ensuring an equitable energy transition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Keep it short: Exploring the impacts of configuration choices on the recent economics of solar-plus-battery and wind-plus-battery hybrid energy plants

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$10$/MWh across ISOs on average. The highest boost occurs in California ($\$15$/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$12.5$/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$12.5$/MWh coupling penalty is reduced to $\$1.6$/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$2$–$\$13$/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

Enhancing the EVI-X National Framework to Address Emerging Questions on Charging Infrastructure Deployment

As national investments in EV charging infrastructure accelerate, this project advances the state-of-the-art in infrastructure analysis to better inform deployment strategies. It enhances NLR's EVI-X Suite, a set of tools supporting national network planning, local site design, and financial evaluation. These capabilities will position VTO to provide timely analysis to the DOT/DOE Joint Office, and to guide the strategic buildout of the national charging network. EVI-X development is closely coordinated with other VTO-funded efforts to ensure consistent, integrated use of key inputs and outputs, including EV adoption scenarios from TEMPO and infrastructure designs developed through EVs@Scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recovery Act: A Measurement -- Management Technology for Improving Energy Efficiency in Data Centers and Telecommunication Facilities (Final Technical Report)

Data center (DC) electricity use is increasing at an annual rate of over 20% and presents a concern for the Information Technology (IT) industry, governments, and the society. A large fraction of the energy use is consumed by the compressor cooling to maintain the recommended operating conditions for IT equipment. The most common way to improve the DC efficiency is achieved by optimally provisioning the cooling power to match the global heat dissipation in the DC. However, at a more granular level, the large range of heat densities of today's IT equipment makes the task of provisioning cooling power optimized to the level of individual computer room air conditioning (CRAC) units much more challenging. Distributed sensing within a DC enables the development of new strategies to improve energy efficiency, such as hot spot elimination through targeted cooling, matching power consumption at rack level with workload schedule, and minimizing power losses. The scope of Measurement and Management Technologies (MMT) is to develop a software tool and the underlying sensing technology to provide critical decision support and control for DC and telecommunication facilities (TF) operations. A key aspect of MMT technology is integration of modeling tools to understand how changes in one operational parameter affect the overall DC response. It is demonstrated that reduced ordered models for DC can generate, in less than 2 seconds computational time, a three dimensional thermal model in a 50 kft 2 DC. This rapid modeling enables real time visualization of the DC conditions and enables "0what if" scenarios simulations to characterize response to "disturbances". One such example is thermal zone modeling that matches the cooling power to the heat generated at a local level by identifying DC zones cooled by a specific CRAC. Turning off a CRAC unit can be simulated to understand how the other CRAC utilization changes and how server temperature responds. Several new sensing technologies were added to the existing MMT platform: (1) air contamination (corrosion) sensors, (2) power monitoring, and (3) a wireless environmental sensing network. All three technologies are built on cost effective sensing solutions that increase the density of sensing points and enable high resolution mapping of DCs. The wireless sensing solution enables Air Conditioning Unit (ACU) control while the corrosion sensor enables air side economization and can quantify the risk of IT equipment failure due to air contamination. Validation data for six test sites demonstrate that leveraging MMT energy efficiency solutions combined with industry best practices results in an average of 20% reduction in cooling energy, without major infrastructure upgrades. As an illustration of the unique MMT capabilities, a data center infrastructure efficiency (DCIE) of 87% (industry best operation) was achieved. The technology is commercialized through IBM System and Technology Lab Services that offers MMT as a solution to improve DC energy efficiency. Estimation indicates that deploying MMT in existing DCs can results in an 8 billion kWh savings and projection indicates that constant adoption of MMT can results in obtainable savings of 44 billion kWh in 2035. Negotiations are under way with business partners to commercialize/license the ACU control technology and the new sensor solutions (corrosion and power sensing) to enable third party vendors and developers to leverage the energy efficiency solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗