Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EVAPORATION RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Channel waveguides in glass via silver-sodium field-assisted ion exchange

Multimode channel waveguides have been formed in sodium aluminosilicate glass by field-assisted diffusion of Ag(+) ions from vacuum-evaporated Ag films. The two-dimensional refractive index profiles of the waveguides were controlled by varying the diffusion time, the diffusion temperature, and the electric field strength. Estimates of the diffusion rate through a strip aperture were obtained, assuming the electric field was strong 120-240 V/mm. The maximum change in refractive index in the sodium aluminosilicate glasses was estimated near 65 percent of the change in soda-lime silicate glass. The physical properties of the glasses are given in a table.

Forrest, K.↗

Microheater Array Boiling Experiment

By conducting pool boiling tests in microgravity, the effect of buoyancy on the overall boiling process and the relative magnitude of other phenomena can be assessed. Data from KC-135 and sounding rocket experiments indicate little effect of gravity on boiling heat transfer at wall superheats below 25 C, despite vast differences in bubble behavior between gravity levels. In microgravity, a large primary bubble, surrounded by smaller satellite bubbles, moved over the surface, occasionally causing nucleation. Once formed, the primary bubble size remained constant for a given superheat, indicating evaporation at the bubble base is balanced with condensation on the bubble cap. The primary bubble's size increased with wall superheat. Most heaters under the primary bubble had low heat transfer rates, suggesting liquid dryout. Strong Marangoni convection developed in microgravity, forming a 'jet' into the bulk liquid that forced the bubble onto the heater. An experiment is being designed for the. Microgravity Science Glovebox. This experiment uses two 96 element microheater arrays, 2.7 and 7.0 mm in size. These heaters are individually controlled to operate at a constant temperature, measuring local heat fluxes as a function of time and space. Most boiling experiments operate at constant wall heat flux with larger heaters, allowing only time and space-averaged measurements. Each heater is about the bubble departure size in normal gravity, but significantly smaller than the bubble departure size in reduced gravity.

Kim, Jungho↗

Sensitivity of the Tropical Atmospheric Energy Balance to ENSO-Related SST Changes: Comparison of Climate Model Simulations to Observed Responses

This paper focuses on how fresh water and radiative fluxes over the tropical oceans change during ENSO warm and cold events and how these changes affect the tropical energy balance. At present, ENSO remains the most prominent known mode of natural variability at interannual time scales. While this natural perturbation to climate is quite distinct from possible anthropogenic changes in climate, adjustments in the tropical water and energy budgets during ENSO may give insight into feedback processes involving water vapor and cloud feedbacks. Although great advances have been made in understanding this phenomenon and realizing prediction skill over the past decade, our ability to document the coupled water and energy changes observationally and to represent them in climate models seems far from settled (Soden, 2000 J Climate). In a companion paper we have presented observational analyses, based principally on space-based measurements which document systematic changes in rainfall, evaporation, and surface and top-of-atmosphere (TOA) radiative fluxes. Here we analyze several contemporary climate models run with observed SSTs over recent decades and compare SST-induced changes in radiation, precipitation, evaporation, and energy transport to observational results. Among these are the NASA / NCAR Finite Volume Model, the NCAR Community Climate Model, the NCEP Global Spectral Model, and the NASA NSIPP Model. Key disagreements between model and observational results noted in the recent literature are shown to be due predominantly to observational shortcomings. A reexamination of the Langley 8-Year Surface Radiation Budget data reveals errors in the SST surface longwave emission due to biased SSTs. Subsequent correction allows use of this data set along with ERBE TOA fluxes to infer net atmospheric radiative heating. Further analysis of recent rainfall algorithms provides new estimates for precipitation variability in line with interannual evaporation changes inferred from the da Silva, Young, Levitus COADS analysis. The overall results from our analysis suggest an increase (decrease) of the hydrologic cycle during ENSO warm (cold) events at the rate of about 5 W/sq m per K of SST change. Model results agree reasonably well with this estimate of sensitivity. This rate is slightly less than that which would be expected for constant relative humidity over the tropical oceans. There remain, however, significant quantitative uncertainties in cloud forcing changes in the models as compared to observations. These differences are examined in relationship to model convection and cloud parameterizations Analysis of the possible sampling and measurement errors compared to systematic model errors is also presented.

Robertson, Franklin R.↗

Sensitivity of the Tropical Atmosphere Energy Balance to ENSO-Related SST Changes: How Well Can We Quantify Hydrologic and Radiative Responses?

The continuing debate over feedback mechanisms governing tropical sea surface temperatures (SSTs) and tropical climate in general has highlighted the diversity of potential checks and balances within the climate system. Competing feedbacks due to changes in surface evaporation, water vapor, and cloud long- and shortwave radiative properties each may serve critical roles in stabilizing or destabilizing the climate system. It is also intriguing that even those climate variations having origins internal to the climate system-- changes in ocean heat transport for example, apparently require complementary equilibrating effects by changes in atmospheric energy fluxes. Perhaps the best observational evidence of this is the relatively invariant nature of tropically averaged net radiation exiting the top-of-atmosphere (TOA) as measured by broadband satellite sensors over the past two decades. Thus, analyzing how these feedback mechanisms are operating within the context of current interannual variability may offer considerable insight for anticipating future climate change. In this paper we focus on how fresh water and radiative fluxes over the tropical oceans change during ENSO warm and cold events and how these changes affect the tropical energy balance. At present, ENSO remains the most prominent known mode of natural variability at interannual time scales. Although great advances have been made in understanding this phenomenon and realizing prediction skill over the past decade, our ability to document the coupled water and energy changes observationally and to represent them in climate models seems far from settled (Soden, 2000 J Climate). Our analysis makes use a number of data bases, principally those derived from space-based measurements, to explore systematic changes in rainfall, evaporation, and surface and top-of-atmosphere (TOA) radiative fluxes, A reexamination of the Langley 8-Year Surface Radiation Budget data set reveals errors in the surface longwave emission due to use of biased SSTs. Subsequent correction allows subsequent use of this data set along with ERBE TOA fluxes to infer net atmospheric radiative beating. Further analysis of recent rainfall algorithms provides new estimates for precipitation variability in line with interannual evaporation changes inferred from the da Silva, Young, Levitus COADS analysis. The overall results from our analysis suggest an increase (decrease) of the hydrologic cycle during ENSO warm (cold) events at the rate of about 5 Wm-2 per K of SST change. This rate is slightly less than that which would be expected for constant relative humidity over the tropical oceans. Corresponding radiative fluxes seem systematically smaller resulting in a enhanced (suppressed) export of energy from the tropical ocean regions during warm (cold) SST events. Discussion of likely errors due to sampling and measurement strategies are discussed along with their impacts on our conclusions.

Robertson, Franklin R.↗

Lunar and Planetary Science XXXV: Isotopes in Meteorites

The session"Isotopes in Meteorites" consisted of the following presentations:The Common Property of Isotopic Anomalies in Meteorites; Revised Production Rates for 22Na and 54Mn in Meteorites Using Cross Sections Measured for Neutron-induced Reactions; Modeling of 14C and 10Be Production Rates in Meteorites and Lunar Samples; Investigating Xenon Isotopic Fractionation During Rayleigh-type Distillation; The Mean Life Squared Relationship for Abundances of Extinct Radioactivities; and Magnesium Isotopic Fractionation of Forsterite During Evaporation from Different Crystallographic Surfaces.

Source record↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

The Affect of the Space Environment on the Survival of Halorubrum Chaoviator and Synechococcus (Nageli): Data from the Space Experiment OSMO on EXPOSE-R

We have shown using ESA's Biopan facility flown in Earth orbit that when exposed to the space environment for 2 weeks the survival rate of Synechococcus (Nageli), a halophilic cyanobacterium isolated from the evaporitic gypsum-halite crusts that form along the marine intertidal, and Halorubrum chaoviator a member of the Halobacteriaceae isolated from an evaporitic NaCl crystal obtained from a salt evaporation pond, were higher than all other test organisms except Bacillus spores. These results led to the EXPOSE-R mission to extend and refine these experiments as part of the experimental package for the external platform space exposure facility on the ISS. The experiment was flown in February 2009 and the organisms were exposed to low-Earth orbit for nearly 2 years. Samples were either exposed to solar ultraviolet (UV)-radiation (lambda is greater than 110 nm or lambda is greater than 200 nm, cosmic radiation (dosage range 225-320 mGy), or kept in darkness shielded from solar UV-radiation. Half of each of the UV-radiation exposed samples and dark samples were exposed to space vacuum and half kept at 105 pascals in argon. Duplicate samples were kept in the laboratory to serve as unexposed controls. Ground simulation control experiments were also performed. After retrieval, organism viability was tested using Molecular Probes Live-Dead Bac-Lite stain and by their reproduction capability. Samples kept in the dark, but exposed to space vacuum had a 90 +/- 5% survival rate compared to the ground controls. Samples exposed to full UV-radiation for over a year were bleached and although results from Molecular Probes Live-Dead stain suggested approximately 10% survival, the data indicate that no survival was detected using cell growth and division using the most probable number method. Those samples exposed to attenuated UV-radiation exhibited limited survival. Results from of this study are relevant to understanding adaptation and evolution of life, the future of life beyond earth, the potential for interplanetary transfer of viable microbes via meteorites and dust particles as well as spacecraft, and the physiology of halophiles.

space flight↗

Observation of microwave shielding of ultracold molecules

Harnessing the potential wide-ranging quantum science applications of molecules will require control of their interactions. Here, we used microwave radiation to directly engineer and tune the interaction potentials between ultracold calcium monofluoride (CaF) molecules. By merging two optical tweezers, each containing a single molecule, we probed collisions in three dimensions. The correct combination of microwave frequency and power created an effective repulsive shield, which suppressed the inelastic loss rate by a factor of six, in agreement with theoretical calculations. The demonstrated microwave shielding shows a general route to the creation of long-lived, dense samples of ultracold polar molecules and evaporative cooling.

Anderegg, Loïc↗

Synthesis of observed and simulated rain microphysics to inform a new Bayesian statistical framework for microphysical parameterization in climate models (Final Scientific Report)

This project aimed to investigate a new approach to bulk microphysics schemes. We identified the need to move beyond the fixed structural assumptions and approximation of existing schemes. For example, most schemes assume some functional form for the rain drop size distribution (e.g. a gamma or exponential distribution). Most schemes then evolve some number of statistical moments of that distribution via various processes, such as evaporation, sedimentation, collision-coalescence, and collisional breakup. These microphysical processes, in turn, are typically some fixed functional form derived from either some other (more detailed) model, or using some single-particle rates that are then integrated over the size distribution. While these process rate functions may have some free parameters to adjust, in other cases doing so is impossible (e.g. when the process rates are analytical or piecewise solutions to some target function). Our goal was to build and test a scheme that assumed no size distribution form, and used a series of power laws as the basis for the process rates. Moments of the size distribution would be predicted, but no underlying size distribution would be specified. Any number or choice of size distribution moments could be used, and any number of power laws could be employed to model the process rates. Thus, our approach is flexible, and can seamlessly scale across levels of complexity, as demanded by the data. Bayesian inference then would provide the formalism to estimate the model parameters and structure, allowing for robust uncertainty quantification. We proposed testing this framework in idealized simulations using bin microphysical schemes as a data source. We also proposed using real data to inform our microphysics scheme, and also that we would integrate our scheme into WRF.

58 GEOSCIENCES↗

Hydrogen environment embrittlement of metals

Hydrogen environment embrittlement refers to metals stressed while exposed to a hydrogen atmosphere. Tested in air, even after exposure to hydrogen under pressure, this effect is not observed on similar specimens. Much high purity hydrogen is prepared by evaporation of liquid hydrogen, and thus has low levels for potential impurities which could otherwise inhibit or poison the absorbent reactions that are involved. High strength steels and nickel-base allows are rated as showing extreme embrittlement; aluminum alloys and the austenitic stainless steels, as well as copper, have negligible susceptibility to this phenomenon. The cracking that occurs appears to be a surface phenomenon, is unlike that of internal hydrogen embrittlement.

Jewett, R. P.↗

Effect of vaporization on cryogenic spray dropsize measurement

The fluid mechanics of multi-phase flow breakup of liquid nitrogen, LN2, jets injected into sonic velocity nitrogen gasflow, was experimentally investigated. A scattered-light scanning instrument was used to measure the characteristic dropsize, D(sub v.5), of LN2 sprays and to determine the effect of droplet vaporization on experimental dropsize measurements. Under sonic gas-velocity conditions, liquid-jet breakup occurred in the regime of aerodynamic stripping. As a result, the following correlation of volume-median drop diameter, D(sub v.5), with atomizing gas flowrate, W(sub g), was derived for two-fluid atomizers; with atomizing gas flowrate, W(sub g), was derived for two-fluid atomizers; (D(sub v.5))(exp -1) = k(sub c)(W(sub g))(sup n), where proportionally constant k(sub c) and exponent n are functions of droplet vaporization rate. Partially vaporized sprays were investigated and it was found that n = 1.11, which is considerably less than the value of 1.33 that is predicted by atomization theory. This was attributed to the evaporative loss of very small droplets. As a result, the following expression was obtained experimentally: (D(sub v.5e))(exp -1) = 301(W(sub g))(sup 1.11). Values of D(sub v.5), that existed prior to partial vaporization of the LN2 sprays, were calculated and the following expression was derived for originally unvaporized LN2 sprays: (D(sub v.5))(exp -1) = 285(W(sub g))(sup 1.33). This expression agrees well with atomization theory that predicts n = 1.33, for liquid jet breakup in high-velocity gasflow.

Ingebo, Robert D.↗

Tracking of raindrops in flow over an airfoil

The splashback that occurs when raindrops impact an airfoil results in an 'ejecta fog' of small droplets around the leading edge. Acceleration of these droplets by the air flow field is a momentum sink for the air flow and has been hypothesized to contribute to the degradation of airfoil performance in heavy rain. Presented here is a one-way coupled Eulerian-Lagrangian particle tracking scheme to evaluate droplet number densities and momentum sink terms around a NACA 64-210 airfoil section for three rainfall rates. A laminar air flow field is determined with a standard CFD code and input to the particle tracking algorithm. Raindrops are assumed to be non-interacting, non-deforming, non-evaporating, and non-spinning spheres and are tracked through the curvilinear grid used by the air flow code. A simple model is used to simulate impacts and the resulting splashback on the airfoil surface.

Valentine, James R.↗

Effect of vaporization on cryogenic spray dropsize measurement

The fluid mechanics of multi-phase flow breakup of liquid nitrogen, LN2, jets injected into sonic velocity nitrogen gasflow, was experimentally investigated. A scattered-light scanning instrument was used to measure the characteristic dropsize, D(sub v.5), of LN2 sprays and to determine the effect of droplet vaporization on experimental dropsize measurements. Under sonic gas-velocity conditions, liquid-jet breakup occurred in the regime of aerodynamic stripping. As a result, the following correlation of volume-median drop diameter, D(sub v.5), with atomizing gas flowrate, W(sub g), was derived for two-fluid atomizers: (D(sub v.5)) (exp -1) = k(sub c) (W(sub g)) (sup n), where proportionally constant k(sub c) and exponent n are functions of droplet vaporization rate. Partially vaporized sprays were investigated and it was found that n = 1.11, which is considerably less than the value of 1.33 that is predicted by atomization theory. This was attributed to the evaporative loss of very small droplets. As a result, the following expression was obtained experimentally: (D(sub v.5e)) (exp -1) = 301 (W(sub g)) (sub 1.11). Values of D(sub v.5), that existed prior to partial vaporization of the LN2 sprays, were calculated and the following expression was derived for originally unvaporized LN2 sprays: (D(sub v.5)) (exp -1) = 285 (W(sub g)) (sub 1.33). This expression agrees well with atomization theory that predicts n = 1.33, for liquid jet breakup in high-velocity gasflow.

Ingebo, Robert D.↗

The trend of production rates with heliocentric distance for comet P/Halley

Comet P/Halley was observed spectroscopically in the wavelength range 5200-10,400 A during 10 observing runs, roughly a month apart from 1985 August 28 to 1986 June 6. The observations span a heliocentric distance from 0.73 to 2.52 AU. This data set is analyzed to determine the course of the production rate with heliocentric distance for C2, NH2, CN, and the continuum. The effect of changing the Haser scale lengths and their heliocentric distance dependence is examined. The production rate ratios to water change only in a minor way, but the absolute values of the production rates are more severely affected. Fluorescent efficiencies, or g-factors for the CN red system are calculated, and band intensity ratios for NH2 and CN are presented. Using presently available fluorescence efficiencies and Haser scale lengths, mixing ratios for the parents of C2, CN, and NH2 with respect to water are: 0.34 +/- 0.07%, 0.15 +/- 0.04%, and 0.13 +/- 0.05%. It is found that these mixing ratios are essentially constant over the heliocentric distance range of the observations, implying a rather uniform nucleus and uniform outgassing characteristics, although there are indications of smaller scale day-to-day variations. The results provide strong observational confirmation that water evaporation controls the activity of the comet over the distance range studied. Continuum values Af rho are determined, and their ratios to QH2O are found to have a clear dependence with heliocentric distance approximately r(exp -1.0) with a post-perihelion enhancement. No correlation of the production rate ratios with light curve of P/Halley were found, nor was there any correlation of the C2 or CN production with the dust.

Fink, Uwe↗

Estimate of Gamma Dose Rates from Arrays of Fermi-1 Blanket Elements During the MEDE Process

The Enrico Fermi Atomic Power Plant Unit 1 (Fermi-1) was a sodium-cooled fast breeder reactor located in Monroe County, Michigan. The reactor was powered by a core of enriched uranium metal alloy driver fuel, which was enveloped by an axial and radial blanket material consisting of depleted uranium metal alloyed with 3 wt.% molybdenum. There are 406 axial and 559 radial irradiated sodium-bonded Fermi-1 blanket assemblies in storage at INL, totaling 34 metric tons of heavy metal. Disposal of the Fermi-1 blanket material directly into a geological repository is prohibited due to the reactive characteristic of its bond sodium. A melt drain evaporate (MEDE) process can effectively remove bond sodium from Fermi-1 blanket material. Consequently, planning is underway to apply a MEDE process to treat the 34 metric tons of heavy metal of irradiated Fermi-1 blanket material. Given the irradiated Fermi-1 blanket material’s relatively low power history and 50+ years of decay, it can be treated in a shielded glovebox. To assess the requisite shielding, the dose rates of the Fermi-1 blanket elements in various process configurations are needed. The method to perform the dose rate calculations is to first generate an average source term and associated photon source spectra for the Fermi-1 blanket material in SCALE and then use the associated photon spectra to calculate dose rates using MCNP6.2 in seven representative geometries. Dose rates in rem/h were calculated on contact (1 cm from outer geometry surface), 30 cm away from outer geometry surface, and 1 m from outer geometry surface at axial heights spanning the length of the blanket material within the geometry. The maximum average dose rate for the single Fermi-1 radial blanket element is ~0.60 rem/h, for the Fermi-1 radial blanket assembly ~1.10 rem/h, for the single Fermi-1 axial blanket element ~0.5 rem/h, for the Fermi-1 axial blanket assembly ~1.01 rem/h, for the MEDE can ~ 0.98 rem/h, for the Fermi Storage Canister ~ 0.83 rem/h, and for the MEDE cans in the DOE Standard Canister ~0.51 rem/h. Based on these maximum average values, the bounding dose rates are assumed to be 3× the average dose rates calculated for the axial blanket material and 7.6× the average dose rates calculated for the radial blanket material, based on the distribution of Fermi-1 blanket material assembly burnup.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spray process of multi-component gasoline surrogate fuel under ECN Spray G conditions

As modern gasoline direct injection (GDI) engines utilize sophisticated injection strategies, a detailed understanding of the air-fuel mixing process is crucial to further improvements in engine emission and fuel economy. In this study, a comprehensive evaluation of the spray process of single-component iso-octane (IC8) and multi-component gasoline surrogate E00 (36 % n-pentane, 46 % iso-octane, and 18 % n-undecane, by volume) fuels was conducted using an Engine Combustion Network (ECN) Spray G injector. High-speed extinction, schlieren, and microscopy imaging campaigns were carried out under engine-like ambient conditions in a spray vessel. Experimental results including liquid/vapor penetration, local liquid volume fraction, droplet size, and projected liquid film on the nozzle tip were compared under ECN G1 (573 K, 3.5 kg/m 3 ), G2 (333 K, 0.5 kg/m 3 ), and G3 (333 K, 1.01 kg/m 3 ) conditions. In addition to the experiments, preferential evaporation process of the E00 fuel was elucidated by Large–Eddy Simulations (LES). The three-dimensional liquid volume fraction measurement enabled by the computed tomographic reconstruction showed substantial plume collapse for E00 under the G2 and G3 conditions having wider plume growth and plume-to-plume interaction due to the fuel high vapor pressure. Here, the CFD simulation of E00 showed an inhomogeneity in the way fuel components vaporized, with more volatile components carried downstream in the spray after the end of injection. The high vapor pressure of E00 also results in ~4 μm smaller average droplet diameter than IC8, reflecting a higher rate of initial vaporization even though the final boiling point temperature is higher. Consistent with high vapor pressure, E00 had a wider plume cone angle and enhanced interaction with the wall to cover the entire surface of the nozzle tip in a film. However, the liquid fuel underwent faster evaporation, so the final projected tip wetting area was smaller than the IC8 under the flash-boiling condition.

33 ADVANCED PROPULSION SYSTEMS↗

Impacts of caking on corn stover – An assessment of moisture content and consolidating pressure

Caking or time consolidation of powders is a serious problem which can hinder productivity and overall feasibility of various industrial processes. Here this study focuses on the impacts moisture content and consolidating pressures can have on 2 mm corn stover samples after undergoing a drying treatment at different times. Individually, moisture content and consolidating pressure did not exhibit any significant changes throughout the modified variable flow rate tests using the FT4 powder rheometer. However, applying both variables simultaneously yielded higher-than-usual energy outputs from the corn stover, indicative of biomass agglomeration due to the moisture and its subsequent evaporation while under pressure via the induced consolidating pressure. However, despite the increase in energy usage, time dried did not have a direct effect and demonstrated no trend.

36 MATERIALS SCIENCE↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗